4100-216

   EMBED


Share

Transcript

Terminal Block #1 (Opt.) Indoor Blower Motor 23 O1 Y Y1 C 15 14 12 10 9 6 3 2 230/208-60-3 230/208-60-1 1 L1 L2 Red/White 1 2 3 Black 49 Yellow/Red Yellow L1 48 L2 T1 T2 36 70 69 CC L1 C C Y Defrost Control 51 SEN JMP Black Low Ambient Control (Opt.) 12 T2 T1 Outdoor Fan Motor T3 42 42 Compressor S L1 High Pressure Switch Reversing Valve RV Compressor Contactor Defrost Control Term. Block RV #5 B RV W2 W2 3 D 6 7 9 4 Electric Heat Relay (Opt.) Electric Heat Relay T. Block #2 Term. Block #5 Reversing Valve Low Ambient Bypass Heater Contactor #2 D T. Block #1 O1 Y Terminal Block #5 11 Gnd F 5 1 Plug #2 A C Heater Contactor #1 C 44 Tan Blue S Defrost Sensor T. Block #2 Pressure Lockout Indicator 6 Plug #1 CC Y L L 2 45 1 LO T. Block #2 C Lower Control Panel 47 Defrost Sensor Low Pressure Switch C T. Block #2 Tan Blue Blue 12 12 28 SENSOR L2 Y 9 TERM SPEED TEMP UP 30 60 90 SENSOR R C B 12 Condenser Section Black 39 Yo C R L1 Low Pressure Term. Block Control #5 Phase Monitor 11 C TWV L0 LC T2 13 Black H 7 TWV 7 2 24VAC Transformer Term. Block High Pressure #5 Control 8 T3 Black Yellow Black/White Black Blk T1 Yellow Brown T1 T2 46 9 Terminal Block #4 Yellow Outdoor Fan Capacitor 17 Black Low Ambient Bypass (Opt.) R Term. Block #5 27 4 5 L Yellow 2 6 Y Outdoor Fan Motor Out. Fan Capacitor 3 Purple/White E Red 1 RV 2 1 Blue/Red 35 Black/White 3 L2 COM Black Ground 4 Red Red/White COM 64 Y Y1 B 63 NC Red C 30 B Blue 37 32 R Blue 208V 40 Blue Red 230V Black Red B L1 SENSOR Blue/Black 67 57 Yellow 27 Black Red/White Black/White R Black Yel/Blk Blk/Whte Yo Y C L1 L2 L3 26 Transformer 60 Terminal Block #3 10 66 41 Red Phase Monitor 72 58 R T1 COM L0 W2 F2 3 460 L2 LO 1 T2 Low Amb. Control (Opt.) Black T3 3 F1 L1 L2 L3 Pink L3 Blk/Whte Yellow H Black 34 59 Comp. Contactor Low Amb. Bypass (Opt.) Term. Block #3 T. Block #1 Upper Control Panel L Red/Black Blk/Whte C 38 27 10 68 Pink Blue 43 F Pressure Lockout Indicator 61 R W2 Blk/Whte Brown B T1 T. Block #2 31 29 Blk/Whte Y Brown G2 Blue Yellow G T1 1 Phase Monitor 33 11 Terminal Block #2 T2 L1 Terminal Block #4 Gnd Green Red Yellow T2 Outdoor Motor Relay Brown Plug #1 L2 T3 T3 Yellow Brown/White T3 Red 1 2 3 3 L3 Black 25 Plug #3 Black/White 3 4 5 6 7 8 9 10 11 12 L1 L3 Orange Orange Red/Yellow Blk/Whte Brown Blk/Whte Blue Black Purple Red/Whte B Orange B Blk/Whte 1 2 Red/Whte Brn/Whte 24 Plug #2 Red/Whte L2 Compressor Compressor Contactor L3 1 2 3 B C T. Block #2 T. Block #2 G G2 1 3 2 9 6 14 12 10 15 Indoor Blower Motor Plug #3 D Labeled wires connect if no options used. E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. ! WARNING Remove jumper when Low Amb. Bypass is USE COPPER CONDUCTORS H installed. ONLY SUITABLE FOR AT LEAST Factory High Voltage Low Voltage Field Optional 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4100-216