Preview only show first 10 pages with watermark. For full document please download

4100-224

   EMBED


Share

Transcript

Indoor Blower Motor 23 15 14 12 10 9 6 3 230/208-60-3 1 2 L2 L1 Red L L1 Yellow 48 L2 T1 T2 36 70 Yel/Blk 27 Black/White 37 C Red/White Black Red 40 63 4 29 32 30 R R W2 B L2 RV Y L CC L1 C C COM 64 35 42 44 45 H A LO COM Y B T2 Purple/White C RV TWV Terminal Block #5 11 T3 Compressor Low Pressure Switch Black Black Black Blue Blue Defrost Sensor Reversing Valve 3 Way Valve Gnd Lower Control Panel Tan Blue S Black/White Blue S Condenser Section T1 High Press. Switch Blue 12 Red 12 T2 Outdoor Fan Motor Controller L0 Black Low Ambient Control (Opt.) L1 RV 6 7 9 4 Electric Heat Relay (Opt.) Electric Heat Relay 3 T. Block #2 A Reversing Valve Low Ambient Bypass Heater Contactor #2 Y 1 2 3 B C Term. Block #3 C Heater Contactor #1 C F Plug #2 3 CC W2 5 1 Blue 12 Black LC Red Yellow Red/Black T2 A L. A. Control (Opt.) Compressor Term. Contactor Term. Defrost Control Block Block #5 RV #5 W2 3 T1 1 T. Block #2 D O. Motor Controller L. A. Bypass (Opt.) L Pressure Lockout Indicator 11 28 Blue/Red 9 Terminal Block #4 T3 Blue Low Ambient Bypass (Opt.) T1 Yellow Brown Black H 7 Defrost Sensor NC 7 47 Black Black/White Tan Blk SENSOR L2 B 6 Plug #1 Yellow 69 5 T1 T2 SENSOR R C T. Block #2 9 TERM SPEED TEMP UP 30 60 90 R L1 Low Pressure Term. Block Control #5 L Defrost Control 51 1 D Black 4 Term. Block High Pressure #5 Control Yo C Term. Block #5 Red 6 Y 2 C 3 Way Valve Purple/White 1 2 24VAC T. Block #2 Black/White 3 TWV 7 2 1 3 Term. Block #5 8 42 T1 COM R Phase Monitor NC SEN JMP T2 T1 Transformer 230V L1 Red E COM Ground 57 27 Outdoor Fan Motor Controller L0 SENSOR Blue/Red Blue/Black Black Blk/Whte Yellow Yo Y C 67 230V 208V Black 41 Red Red/White 26 Transformer 60 Black 66 L1 L2 L3 R Terminal Block #3 10 58 T2 LC LO T3 Blk/Whte Yellow Phase Monitor 72 T1 T. Block #2 Pink Yellow/Red L3 38 27 L1 T3 T3 Terminal Block #4 Yellow/Red 34 59 Comp. Contactor 49 T2 68 Yellow/Red C 33 Upper Control Panel Blk/Whte R W2 Pink Blue 43 F Pressure Lockout Indicator 61 Red/Whte Brown B Blk/Whte Blk/Whte Y G2 Brown G Blue Yellow 31 11 Terminal Block #2 L2 L1 L2 L3 10 Black Yellow 1 2 3 Phase Monitor Brown Plug #1 T3 Gnd Green Red/White Yellow Black/White L3 Red 1 2 3 Black 25 Plug #3 Brown/White 3 4 5 6 7 8 9 10 11 12 L1 L3 Orange Orange Red/Yellow Blk/Whte Brown Blk/Whte Blue Black 1 2 Purple Orange 24 Plug #2 Red/Whte L2 Compressor Compressor Contactor L3 T. Block #2 T. Block #2 G G2 1 3 2 9 6 14 12 10 15 Indoor Blower Motor Plug #3 D Labeled wires connect if no options used. E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. ! WARNING Remove jumper when Low Amb. Bypass is USE COPPER CONDUCTORS H installed. ONLY SUITABLE FOR AT LEAST Factory High Voltage Low Voltage Field Optional 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4100-224