Preview only show first 10 pages with watermark. For full document please download

4100-316

   EMBED


Share

Transcript

O1 Y Y1 C 23 Indoor Blower Motor 15 14 12 10 9 6 3 2 460-60-3 1 L1 L2 Purple/White 1 Brown/White 2 Black/White Yellow 3 T3 L2 T2 T2 L1 T1 T1 H 460V Red L1 Phase Monitor 10 F2 Low Amb. Control (Opt.) 1 2 3 4 5 L2 Indoor Blower Motor 3 460 R C 64 Low Ambient Control (Opt.) S Outdoor Fan Motor C S S L1 Tan RV High Pressure Switch Terminal Block #7 73 10 460 Compressor Reversing Valve Gnd L2 Terminal Block #6 Defrost Sensor Low Pressure Switch L1 B2 Black Tan B1 Black Blue Blue/Red LC 11 44 Terminal Block #2 Transformer #2 230 C Defrost Sensor CC Y Y T. Block #2 Compressor Contactor Defrost Control Term. Block RV #5 B RV W2 L L T. Block #2 W2 Pressure Lockout Indicator D 3 6 7 9 4 Electric Heat Relay (Opt.) Electric Heat Relay T. Block #2 11 Plug #1 LO 3 Term. Block #5 Reversing Valve Low Ambient Bypass Heater Contactor #2 D T. Block #1 2 O1 Y F 5 1 Plug #2 A C Heater Contactor #1 C C Red 45 Black 12 R Black H 7 C TWV L0 12 12 Black 42 L2 T. Block #2 79 Red Black T1 T2 42 SENSOR C B 6 1 2 3 83 Fuse Block 76 Black Black Yellow Black/White 13 47 T3 T2 35 Brown 5 Blk Yellow 28 Blue Red Blue 4 T1 39 Blue 6 46 Black 2 Terminal 9 Block #4 Yellow Outdoor Fan Capacitor 17 Black Low Ambient Bypass (Opt.) Red 1 67 Black 27 Yellow Yo C 9 TERM SPEED TEMP UP 30 60 90 57 Black/White 3 SEN JMP 36 Red Y 12 Upper Control Panel C 29 R. Vent Opt. Only L1 Red Ground CC Defrost Control 51 Blue Black/White Red/Black 69 COM C L SENSOR Blue/Black Red/White Y 7 SENSOR R L1 Low Pressure Term. Block Control #5 Phase Monitor 8 Black Red 40 RV COM Blue 37 460V 30 L2 2 1 Lower Control Panel 32 B NC Red 68 26 R Black 66 L1 L2 L3 Transformer 60 Terminal Block #3 10 27 R L2 Condenser Section Yel/Blk Yo Y C Yellow Red/White Black 36 Black Phase Monitor 72 2 70 34 Black 3 41 R W2 L1 L0 LO T3 58 Red 1 TWV R Grn T2 Blk/Whte Blk/Whte Black/White Yellow Outdoor Motor Relay 82 Term. Block High Pressure #5 Control 56 Red T1 78 80 Red 48 L2 38 27 Term. Block #5 50 Black Yellow/Red 49 81 L1 77 Yellow/Red 59 Comp. Contactor Pink L3 Yellow/Red 1 24VAC Transformer T. Block #1 63 L Yellow C Pink Blue R Blk/Whte W2 43 F Pressure Lockout Indicator 61 Blk/Whte Brown B Blk/Whte Y Brown G2 Blue Yellow G 11 Terminal Block #2 2 COM 33 4 T1 Outdoor Fan Motor Out. Fan Capacitor L1 L2 L3 Y Y1 B B 1 T2 Term. Block #7 T. Block #2 31 3 F1 T3 T3 Terminal Block #4 Low Amb. Bypass (Opt.) Term. Block #3 1 Transformer Green Red/White L3 Outdoor Motor Relay Yellow Red Black 25 Plug #3 3 Black Brown Blk/Whte Blue Black Purple Red/Whte Orange B L1 L3 Orange Orange Red/Yellow Blk/Whte Brown 3 4 5 6 7 8 9 10 11 12 B Blk/Whte 1 2 Red/Whte Brn/Whte 24 Plug #2 Red/Whte L2 Compressor Compressor Contactor L3 240V Terminal Block #1 (Opt.) 1 2 3 B C T. Block #2 D Labeled wires connect if no options used. Factory Low Voltage G G2 Indoor Blower Motor Plug #3 Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. Remove jumper when Low Amb. Bypass is H installed. High Voltage T. Block #2 1 3 2 9 6 14 12 10 15 Field Optional ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4100-316