Preview only show first 10 pages with watermark. For full document please download

4100c114 D 1 2 3

   EMBED


Share

Transcript

HS1 LS 1 3 BL BL 3 3 QHDA 4100C114 D 3 5 4 4101-103 A HS2 LS 1 2 HS1 LS 1 1 6 BK R BR 230/208-60-1 240/220-50-1 PER NAMEPLATE BR L2 T1 T2 T1 T2 HC1 HC2 CB2 L1 L2 L1 L2 BL BL BK BK 6 B 4 L2 BK BR BR EHR A 7 L1 R CB1 R L1 3 GND 9 GND 5 4 3 2 1 COMPONENT CODE IBM 15 14 12 10 9 IBM 6 2 3 1 L1 "X" Thermostat Option Dehumidification Wiring Diagram 6 5 L2 BR BK G BK R Plug #4 E W1/E 6 Blue 5 Red E Red D/YO 4 A O1 Tan G G Orange Yellow G Y Y1 Y W1 Y1 O/B O/B B Yellow Blue Relay Logic Board 1 Black 2 3 4 Red 5 Red E1 Yellow Tan 6 Orange 7 Yellow 8 Blue W1 AUX W2 Brown 9 R R R Red 10 C C C Black 11 L L W2 L Brown 1 8403-058 TH5220D1151 Thermostat 8403-060 Thermostat Red L E1 BK W TWV A1 YO W2 A2 G RAT D Y 12 Red Low Voltage Term. Block Orange G1 RV R Black Tan Orange Yellow 1 BK 2 3 R 4 O 5 6 7 8 Blue Brown Red Purple 9 10 11 12 BR BK R BR BK 2 R 3 O O BR O R Y BL BK BR 1 2 3 P1 (R VENT OPTION ONLY) R BK Red 2 O O 3 TB2 G Y G2 BK BK BL BR BR Y PR C Y BL BR R R B W2 R BK BK C L BK Black 4102-036 B P3 1 Return Air Thermostat B Rc Black L BK CC F L1 L2 BK T1 PK BK "G" Thermostat Option R R BR W2 T2 8403-060 Thermostat Tan 1 2 3 4 5 G Orange 6 G Tan Orange Y1 Yellow 7 Y1 Yellow B Blue 8 W2 Brown 9 R Red 10 C Black 11 W1/E Red D/YO Yellow A L W1/E Red D/YO Yellow 1 2 3 4 5 Y L PK CC LI Y C C 8 W2 9 R R BK C GND Black C 3 10 11 4102-053 E 3 BK Y1 2 LABELED WIRES CONNECT D IF NO OPTIONS USED. B C MOVE RED WIRE TO 208V TAP FOR 208V OPERATION INSTALL JUMPER FOR HIGH SPEED F BLOWER OPER. ON MODELS 36,42, 48, AND 60 1 C 1 H 3 BK 4102-048 R 2 12 12 Y A CIRCUIT BREAKER #1 CIRCUIT BREAKER #2 COMPRESSOR CONTACTOR COMPRESSOR CONTROL RELAY #1 CONTROL RELAY #2 CONTROL RELAY #3 CONTROL RELAY #4 CONTROL RELAY #5 DUAL CAN CAPACITOR DEFROST CONTROL DEFROST SENSOR FUSE BLOCK GROUND HEATER CONTACTOR #1 HEATER CONTACTOR #2 HIGH PRESSURE CONTROL HEAT STRIP #1 HEAT STRIP #2 INDOOR BLOWER MOTOR LOW AMBIENT BYPASS LOW AMBIENT CONTROL LOW PRESSURE BYPASS LOW PRESSURE CONTROL LIMIT SWITCH OUTDOOR FAN MOTOR ERV (HV) ACCESSORY PLUG CLIMATE CONTROL PLUG VENT (LV) ACCESSORY PLUG PRESSURE LOCKOUT INDICATOR PHASE MONITOR RETURN AIR THERMOSTAT REV. VALVE SOLINOID TRANSFORMER #1 TRANSFORMER #2 TERMINAL BLOCK #1 TERMINAL BLOCK #2 TERMINAL BLOCK #3 TERMINAL BLOCK #4 TERMINAL BLOCK #5 TERMINAL BLOCK #6 TERMINAL BLOCK #7 THREE WAY VALVE LPB Red O1 W1 90 60 30 SENJMPSPEEDUP E 240 208 COM Red Red DFC T1 7 Blue L SENSOR 6 Brown BL RV BR BK O/B R B NO COM R Y BK BK Y 8403-060 Thermostat NC LO PLI "E" Thermostat Option UPPER CONTROL PANEL 4 1 LAB (OPT.) 2 BK GND BK BR Terminal Block #1 BK TB3 DCC H C BK BK PR T1 F F1 F2 Composite Wiring Diagram QH Dehum. Series 2 230/208/60-1, Represents Maximum KW Elect. Heat TB4 R Y Y LC LI T2 Y R BL LO BL BL BL BK BR S S C BL BL BK BK O RV TWV TB5 LOWER CONTROL PANEL 3 O PR R BK BL Y REMOVE JUMPER WHEN LAC IS INSTALLED WIRING CODE FACTORY FIELD STD. OPTIONAL HIGH VOLTAGE LOW VOLTAGE ACCESSORY BK H BK BK BR Y R BK Y C LAC (OPT.) OFM CONDENSER SECTION H200 Humidistat CB1 CB2 CC COMP CR1 CR2 CR3 CR4 CR5 DCC DFC DFS FB GND HC1 HC2 HPC HS1 HS2 IBM LAB LAC LPB LPC LS OFM P1 P2 P3 PLI PM RAT RV T1 T2 TB1 TB2 TB3 TB4 TB5 TB6 TB7 TWV S R LPC R BK RV BK R COMP HPC DFS TWV 4100-114 A COLOR CODE BK BL BR G O BLACK BLUE BROWN GREEN ORANGE PK PR R T Y PINK PURPLE RED TAN YELLOW