Transcript
Heat Strip #1
Brown
R
Red/White
C L
Black/White
A
L3
Emergency Heat Relay
Black/White Yellow
10
91
98
Blue
Red
55
Yellow
Line 3 Line 2 Line 1
96 63
33
Ground
31
52 Lug
Yellow
89
Red/Yellow
4
Purple/White
5 6
Orange
24
Brown/White
56
Brown
10
5
Red/White
4
3
2
Green
Blue
9
Black
Red
Yellow
8
Red/Yellow
Orange
Orange
7
460-60-3 Per Nameplate
Rotary Disconnect
97
Red
90
93
96
98
Black
11 12
L2 L1 97
Blk/Whte
92
Freeze Protect Tstat Bard Part #8408-038
Red/White
L3
L2 L1
92
94
Dehumidification Wiring
Black/White
59
Grn
3
9
T3 T2 T1
59
3 Plug #4
Plug #4
2
4
T3 T2 T1
B
9
4102-066 B
1
3
Red Black
W2
6
Heater Contactor #2
Red
Orange Yellow Blue
7
Brown
A G Y1 B
Red
Heater Contactor #1
To Power Source
88
Brown 1 2 3 4 5 6 7 8
101 99
102
Brown
Black/White
D/YO
100
Black
Black/White
Red/White
Red/Yellow Purple/White
1
86 95
Brown/White
W1/E
Yellow
87
6 8403-060 4 Thermostat
Limit Switch
Blue
Remove jumper when Low Amb. Bypass is H installed.
1
Black
Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60.
Option
Red/White
CO Controller "I" Thermostat Bard Part #8403-067 HOT 1 2 24 VAC 2 COM 3 Analog Out 4 1 5
Limit Switch
Blue
E Move Red wire to 208V tap for 208V operation. 2
3 1
Red
Labeled wires connect if no options used.
D
Limit Switch
3 Red
C
Optional
Low Voltage
3
1
Black
B
Limit Switch
3
Composite Wiring Diagram QH Series 3 460-60-3, Represents Max. KW Electric Heat A
Yellow
Yellow
Field
High Voltage
Yellow
USE COPPER CONDUCTORS *ELECTRICAL SHOCK HAZARD ONLY SUITABLE FOR AT LEAST *DISCONNECT POWER BEFORE 75° C. SERVICING.
Factory
Heat Strip #2
Red
DANGER
!
Blue
WARNING
!
Red
4100C322
1
G
11
Black/White
12
29
Indoor Blower Motor
15 14 12 10 9
23
6
3
1
2
L1
4102-063
Aux R C 8403-058 L TH5220D1151 Rc Thermostat
W2 R C L 8403-060 Thermostat
Low Ambient Bypass (Opt.)
17
6
4
Blk
13
12
H 7
Low Ambient Control (Opt.)
12
R S Outdoor Fan Motor
C
Compressor
Green 28
LC
L1
L0
11
12
Black Black
Terminal Block #5
T2
35
Black
T1 T2
T3
T1
Yellow
Yellow Black/White Tan
7
Terminal Block #3 10
Terminal
9 Block #4
Brown
5
45
47
Outdoor Fan Capacitor
2
8
Yellow
High Press. Switch
Low Pressure Switch
46 42
42
S
S
Defrost Sensor
44
76
39
C RV TWV
3 Way Valve
Reversing Valve
79
B1
L1
B2
Gnd
L2
Terminal Block #6
Terminal Block #7
73
10
460
230
Transformer #2
Lower Control Panel
1
1 2 3
83 Fuse Block
27
Black/White
3
1 2
69
COM
Upper Control Panel
R. Vent Opt. Only
67
Red
Grn
C
Ground
11 12
Yellow Red Black
57
Black
37
Plug #4
9 10
Black Red
36
11
3 4 5 6
Red
Orange Orange Red/Yellow Blk/Whte Brown
Blue
Brown
64
TERM SPEED TEMP UP 30 60 90
Condenser Section
G Y
A G Y1 W1 O/B
30
29
Red
D/YO
32
SEN JMP
Red
W1/E
Red/White
C
SENSOR
Black
Red 40
C
Defrost Control 51
Black
4 E
Black/White 6 Red/White 5 Red/Yellow E Purple/White 4 Brown/White O1 Orange G Yellow Y Y1 Blue B W1 W2 Brown Red/White R C Black/White L Low Voltage Term. Block
460V
L1
Purple/White
5
10 12
H200 Humidistat
68
26
R
L
CC
Black
Black/White
66
L1 L2 L3
Transformer 60
RV
Y
2 1
COM
Black
C
Black
L2
27
Yo Y C
56
NC
Tan
Red/White
Yel/Blk
41
Phase Monitor 72
2
36
B
Black/White
R
7 8 9
34
Black
3
58
W2
Black
Brown
1
4 5 6
70
R
Black
W2
LO R
Blue
Blue
T3
Blue
O/B
T2
Blue
Yellow
T1
50 78
80
Yellow/Red
Blue
Y1
9 10 4102-064 11 6 12 3
O/B
Factory Installed Jumper
Orange
L3
Blue
R C L 4102-079
"X" Thermostat Option
8
Blue
Brown/White
G
L2
Red/Black
Brown Red/White Black/White
A
Red/Yellow Purple/White
Black/White
W2
W1/E D/YO
2 3
Yellow Outdoor Motor Relay 82
Red/White
Red/Yellow Purple/White Brown/White Orange Yellow
1
48
27
Black
D A SC G Y1 SC B SC
Temp. and Humidity Controller PART #8403-060
Black
W1/E
1 2 3 4 5 6 7
59 Comp. Contactor
L1
77
Yellow/Red Pink
38
"J" "K" Thermostat Option "E" Thermostat Option Plug #4 Plug #4
Black
Purple 49
81
"J" CS9BE-THO" K" CS9BE-THOC
63
L
Black
C
Red
43 F Pressure Lockout Indicator 61
R
Red
W2
Black
4102-067 A
B
Blue/Black
Black/White
Relay Logic Board
Y
G2
Red
C
G
Black
Return Air Thermostat
11 Terminal Block #2
Blue/Red
R
Orange
3
B
Red
2
33
Blue
Red/White
12
Yellow
Pink
L3
31
Black
Y
11
Yellow
D
Red/White
Red
RAT
10
Black
G
9
Brown
2 3
Blk/Whte Blk/Whte
A2
Black/White
Red/White
Yellow
YO
Yellow
Black/White
Yellow/Red
A1
8
Blue
1
Brown/White
Red
TWV
W2
7
Yellow
Purple/White
Pink
Orange
BK
W
6
Blk/Whte
RV
5
Blk/Whte
Brown/White
25 Plug #3
Blk/Whte
E1
3 4 5 6 7 8 9 10 11 12
Red/Whte
Purple/White
G1
4
Brown
L
Brown
3
Red/Yellow
E1
1 2
Blue
L
2
Blue
Black
Yellow
1
Red/Whte
L2 24 Plug #2
Purple/White