Preview only show first 10 pages with watermark. For full document please download

4107c202

   EMBED


Share

Transcript

WARNING ! DANGER ! USE COPPER CONDUCTORS *ELECTRICAL SHOCK HAZARD ONLY SUITABLE FOR AT LEAST *DISCONNECT POWER BEFORE 75° C. SERVICING. Bard Mfg. Co. Bryan, Ohio 4107C202 Factory Field Optional High Voltage Low Voltage Heat Strip #1 Yellow Yellow Limit Switch 3 Limit Switch 3 3 3 Black/White Pink 10 11 Blue W2 Brown 7 8 9 R Red/White C Black/White 11 12 4102-069 68 4102-070 NC 3 4 5 T2 T1 Blower Interlock Relay L2 NO NC Yellow Blue Red Blue 30 L2 L1 Black Line 2 74 56 Red Line 1 56 Blk/Whte PWR Line 3 L1 74 Blk 79 208/230-60-3 220/240-50-3 Per Nameplate Circuit Breaker 43 C Red Red Black Yellow Heater Contactor #2 53 T2 T1 Black NO 2 Black/White Optional CS2000A Energy Monitor (Use With "A" Thermostat Only) HVAC 1 Heater 53 Contactor #1 10 12 AREA OCCUPIED 67 Blue C 17 Ground Lug 16 Yellow 83 77 78 Orange Blue Brown Black/White Orange L1 L2 L3 Grn 76 3 "X" THERMOSTAT OPTIONS (FIELD WIRED) Black/White 1 Orange Green Y2 Purple A Brown/White G Black/White Brown Red/White Yellow Analog Out Blue 5 3 2 1 2 Brown R Red/White C Black/White 5 6 7 8 C 9 10 11 Plug #2 Temp. and Humidity Controller Part #8403-060 D Labeled wires connect if no options used. Blue Brown Black/White Black Orange Red Orange Yellow Blue Orange Red/Whte Orange Blk/Whte R C L 25 43 Alarm Relay Compressor Contactor ("X" Tstat. Opt. Only) L1 L2 L3 40 2 T1 T2 T3 27 R C 5 29 Pink 49 Pressure Lockout Indicator Red/White 21 25 15 14 44 50 Phase Monitor 208 L1 L2 L3 42 71 64 72 F1 F2 66 Blk Black H Black 62 Black Low Ambient Control (Opt.) ALR 24 Y C 4 5 1 Black/White T1 T2 Yellow 65 T3 65 Terminal Block #4 63 19 LC L1 L0 20 T3 Compressor S S Terminal 34 Block #5 High Pressure Switch Factory set to "2" Min. 20 65 T2 T1 Outdoor Fan Motor 3 2 32 Compressor Control Module 25 19 Outdoor Fan Capacitor Terminal Block #3 R LPC LPC Yellow Black 12 CC 12 46 48 Pink Yellow/Red HPC 45 E 3 Black/White 47 Red/White Yo Y C Black/White Gnd 39 18 240 COM 4 1 Transformer 33 4102-071 E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. Remove jumper when Low Amb. Bypass is H installed. Remove jumper when CS2000A Energy Monitor is J installed. Red 49 3 4 Blue W2 W2 22 Black/White Black/White Yellow W1/E 26 B 17 Red Black 4 Orange Y1 F 34 Orange Black Y G2 Terminal Block #2 Red/White Brown/White Relay Part #8201-062 24VAC B G "H" Thermostat Option Red 13 16 Blk/Wht 4102-068 CO2 Controller Part #8403-056 A Red/Wht Blue 2 RED BLUE BLACK Blue 1 Blue L3 Blue BLACK/WHITE L2 Blue RED/WHITE C Red R C Red R Plug #1 (R Vent Opt. Only) Red R C Red 1 Green 2 3 Black Yellow BROWN Yellow BLUE W2 Red W1 W2 A Black W W2 Yellow W1/E Plug #1 (E Vent Opt. Only) A Red YELLOW E Blk/White Y1 Blk/Whte Y 11 Plug #3 1 2 3 Yellow Purple Yellow Black Y1 BROWN/WHITE Red F Red PURPLE 1 2 3 Brown/White Black/White Red/White Brown Y2 G 8 Black Y2 Pink Y2 Brown Yellow ORANGE Red/White G 2 1 10 L1 Brown Brown G 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 Yellow G A Plug #2 Plug #2 Red/Whte 8403-060 9 LOW VOLTAGE TERMINAL BLOCK Pink 8403-058 TH5220D1151 Brown/Whte "X" Thermostat Option 3 15 14 12 10 2 6 3 13 1 O1 Y Y1 C Purple Terminal Block #1 ("A" Tstat. Opt. Only) 5 4 Indoor Blower Motor J To Power Source Red/White C L W1/E 5 6 Green R Yellow Green Brown Y1 4 Low Pressure Switch Gnd C RV TWV Upper Control Panel W2 7 8 9 Brown/White Lower Control Panel Blue A 82 80 Condenser Section W1/E Purple 81 54 55 Red Yellow Y2 57 Red Y1 5 6 1 2 3 1 Black 4 Brown/White Plug #2 Orange Limit Switch Brown 1 2 3 Purple Y2 G Red Orange Blue G Red Temp. and Humidity Controller Part #8403-060 Plug #2 Blue "D" Thermostat Option Temp. and Humidity Controller Part #8403-060 1 Blue "A" Thermostat Option 1 Limit Switch Black Red 1 Red Composite Wiring Diagram QH Series 3 208/230-60-3, Represents Max. KW Electric Heat Heat Strip #2