Preview only show first 10 pages with watermark. For full document please download

4107c205

   EMBED


Share

Transcript

WARNING ! 4107C205 A DANGER ! USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Factory Field Optional High Voltage Low Voltage Heat Strip #1 Yellow Yellow Limit Switch 3 Limit Switch 3 106 3 82 Blue 81 Yellow 1 Red Red Limit Switch Blue Red Blue Red 1 Black Yellow 1 Blue Black Red 1 Limit Switch 57 107 3 Red Composite Wiring Diagram QA Dehum. Series 3 208/230-60-3, Represents Max. KW Electric Heat Heat Strip #2 54 2 3 4 5 T3 T2 T1 40 Heater Contactor T1 #2 T3 T2 40 Blower Interlock Relay 68 Black/White L3 L2 L1 55 79 56 Blk/Whte 56 Red W W1/E 1 W1 Blue W2 W2 W2 Brown R R R Red/White C C C Black/White Rc 8403-060 Thermostat E 1 Factory Installed Jumper. Red/Wht Blk/Wht Black/White 2 Remove for 2 stage electronic heat on 15 KW models. G 4102-072 A 4 5 2 6 A 1 Orange G Temp. and Humidity Controller Part #8403-060 4 Plug #2 Purple/White Brown/White D/Y0 Yellow Blue Y1 W1/E W2 Brown R Red/White C Black/White 1 2 3 4 5 6 7 8 9 10 4102-075 A B C D Labeled wires connect if no options used. E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. Remove jumper when Low Amb. Bypass is H installed. Brown Y R B W2 C Pink L 25 98 105 4 99 3 49 240 Transformer 208 C COM 25 49 25 Terminal Block #3 Blk Yellow L1 L2 L3 22 Yellow Black 14 Outdoor Fan Capacitor Yellow T1 T2 Black 62 Black Outdoor Fan Motor Low Ambient Control (Opt.) 66 65 Red Red Black Black/White Green Red Orange G1 RV W T3 19 Terminal Block #4 63 T2 T3 Compressor R ALR Y C 19 TWV A1 G D 3 2 4 5 32 1 LC L1 L0 103 20 97 BK 104 CC LPC LPC Relay Logic Board L E1 W2 Comp. Control Module Black 44 65 T1 47 Red Red 72 HPC Phase Monitor 50 71 Black H L E1 Y0 24 A2 RAT 102 Y B R C Black/White 12 Yo Y C E Black F1 F2 21 Yellow 42 15 64 103 Red/Wht 33 48 Ground 71 40 Purple 100 Pressure Lockout 39 Indicator 18 T1 T2 T3 Blue Control R L1 L2 L3 Black/White 68 Relay #1 2 5 1 29 27 Blue 11 12 A 105 Black/White Purple/White 3 Black/White 26 F 34 Black/White Analog Out 2 Red/White COM Red/White 1 Black/White HOT 24 VAC G2 Terminal Block #2 "I" Thermostat Option CO 2 Controller Bard Part #8403-067 3 101 Yellow Blue Brown P3 P2 P1 Purple/White 46 45 Factory set to 2 min. 20 S S C TWV Terminal 34 Block #5 65 High Pressure Low Pressure 3 Way Switch Valve Switch Ground Upper Control Panel Yellow Green Y1 Lower Control Panel Y1 Condenser Section Y Black Orange 13 43 Red G Yellow G 16 Black Yellow/Black G Black Brown/White Red Brown F Orange A 2 G 17 Black/White Purple/White Black 1 Orange Brown/White 8403-058 TH5220D1151 Thermostat L3 Black/White D/YO Blk/White Red/White Plug #1 (R Vent Opt. Only) Black 2 Brown/White Black/White Red/White Blue 5 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 76 Blue Blue 1 2 3 Compressor Contactor 3 11 Plug #3 Yellow/Red 6 4 Plug #2 Plug #2 8 Red Low Voltage Term. Block Class 2 9 3 13 1 Blue 15 14 12 10 2 6 12 "X" Thermostat Option 3 Blower Motor 11 4102-077 H200 Humidistat 2 1 Blue Black/White 3 Blue C 5 4 9 L1 L2 10 Indoor 10 Black/White Red/White Yellow 12 4102-074 Brown R Brown 11 W2 Yellow 10 Black 9 Black/White 7 8 1 2 3 Blue SC Red Yellow W1/E Red/Black Red/Black Y1 8 Grn SC 7 Blue Red/White 5 6 Black R Orange Pink Brown Brown/White G Brown Black/White Orange Orange Blue 76 Red W2 5 6 A Red/Whte Blue Ground 35 Lug 16 83 Red/White Red/White W1/E 4 Purple Yellow Line 1 Yellow 4 SC Orange Y1 3 Purple/White D 3 78 Red/White Orange Red 17 77 Brown Yellow Brown/White 2 Yellow A 1 Blk/Wht 2 G C Temp. and Humidity Controller "J" CS9BE-THO "K" CS9BE-THOC 1 Purple/White Line 2 Plug #2 Red/White D/YO 43 74 Red "J" Or "K" Thermostat Option Plug #2 Temp. and Humidity Controller PART #8403-060 Black 79 "E" Thermostat Option Line 3 Black 74 Circuit Breaker 55 Yellow Yellow L3 L2 L1 Black 208/230-60-3 220/240-50-3 Per Nameplate 30 Brown Blue 1 Heater Contactor #1 To Power Source 67 Blue