Transcript
WARNING
!
4107C205 A
DANGER
!
USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C.
*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
Factory
Field
Optional
High Voltage Low Voltage Heat Strip #1 Yellow
Yellow
Limit Switch
3
Limit Switch
3
106
3
82
Blue
81
Yellow
1
Red
Red
Limit Switch
Blue
Red
Blue
Red
1
Black
Yellow
1
Blue
Black
Red
1
Limit Switch
57
107
3
Red
Composite Wiring Diagram QA Dehum. Series 3 208/230-60-3, Represents Max. KW Electric Heat
Heat Strip #2
54
2
3
4
5
T3 T2 T1
40
Heater Contactor T1 #2
T3 T2
40
Blower Interlock Relay
68
Black/White
L3
L2 L1 55
79
56
Blk/Whte
56
Red
W
W1/E
1
W1
Blue
W2
W2
W2
Brown
R
R
R
Red/White
C
C
C
Black/White
Rc
8403-060 Thermostat
E
1 Factory Installed Jumper.
Red/Wht Blk/Wht
Black/White
2 Remove for 2 stage electronic heat on 15 KW models.
G
4102-072 A
4 5
2
6
A
1
Orange
G Temp. and Humidity Controller Part #8403-060 4
Plug #2
Purple/White Brown/White
D/Y0
Yellow Blue
Y1 W1/E W2
Brown
R
Red/White
C
Black/White
1 2 3 4 5 6 7 8 9 10
4102-075 A
B
C
D Labeled wires connect if no options used.
E Move Red wire to 208V tap for 208V operation. Install jumper for hi speed blower oper. on F models 36, 42, 48, and 60. Remove jumper when Low Amb. Bypass is H installed.
Brown
Y
R
B W2
C
Pink
L
25
98
105
4 99
3
49
240
Transformer
208
C
COM
25
49
25
Terminal Block #3
Blk
Yellow
L1 L2 L3 22
Yellow
Black
14
Outdoor Fan Capacitor
Yellow
T1 T2
Black
62
Black
Outdoor Fan Motor Low Ambient Control (Opt.)
66
65
Red
Red Black Black/White
Green
Red
Orange
G1 RV W
T3
19
Terminal Block #4 63
T2 T3
Compressor
R
ALR
Y
C
19
TWV
A1 G D
3 2
4 5
32
1
LC L1 L0
103
20
97
BK
104
CC
LPC LPC
Relay Logic Board
L E1
W2
Comp. Control Module
Black
44
65
T1
47
Red Red
72
HPC
Phase Monitor 50
71
Black
H
L E1
Y0
24
A2 RAT
102
Y B
R C
Black/White
12
Yo Y C
E
Black
F1 F2
21
Yellow
42
15
64
103
Red/Wht
33
48
Ground
71
40
Purple
100
Pressure Lockout 39 Indicator
18
T1 T2 T3
Blue
Control
R
L1 L2 L3
Black/White
68 Relay #1
2 5 1
29
27
Blue
11 12
A
105
Black/White Purple/White
3
Black/White
26 F
34
Black/White
Analog Out
2
Red/White
COM
Red/White
1
Black/White
HOT
24 VAC
G2
Terminal Block #2
"I" Thermostat Option CO 2 Controller Bard Part #8403-067 3
101
Yellow Blue Brown
P3 P2 P1
Purple/White
46 45
Factory set to 2 min.
20
S
S
C
TWV
Terminal
34 Block #5
65
High Pressure Low Pressure 3 Way Switch Valve Switch
Ground
Upper Control Panel
Yellow
Green
Y1
Lower Control Panel
Y1
Condenser Section
Y
Black
Orange
13
43
Red
G
Yellow
G
16
Black
Yellow/Black
G
Black
Brown/White
Red
Brown
F
Orange
A
2
G
17
Black/White
Purple/White
Black
1
Orange Brown/White
8403-058 TH5220D1151 Thermostat
L3
Black/White
D/YO
Blk/White
Red/White
Plug #1 (R Vent Opt. Only)
Black
2
Brown/White Black/White Red/White
Blue
5
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12
76
Blue
Blue
1 2 3
Compressor Contactor
3
11
Plug #3
Yellow/Red
6
4
Plug #2
Plug #2
8
Red
Low Voltage Term. Block Class 2
9
3 13 1
Blue
15 14 12 10 2 6
12
"X" Thermostat Option
3
Blower Motor
11
4102-077
H200 Humidistat
2 1
Blue
Black/White
3
Blue
C
5 4
9
L1 L2
10 Indoor
10
Black/White
Red/White
Yellow
12
4102-074
Brown
R
Brown
11
W2
Yellow
10
Black
9
Black/White
7 8
1 2 3
Blue
SC
Red
Yellow
W1/E
Red/Black Red/Black
Y1
8
Grn
SC
7
Blue
Red/White
5 6
Black
R
Orange
Pink
Brown
Brown/White
G
Brown Black/White Orange
Orange
Blue
76
Red
W2
5 6
A
Red/Whte
Blue
Ground
35 Lug
16
83
Red/White Red/White
W1/E
4
Purple
Yellow
Line 1
Yellow
4
SC
Orange
Y1
3
Purple/White
D
3
78
Red/White
Orange
Red
17
77
Brown Yellow
Brown/White
2
Yellow
A
1
Blk/Wht
2
G
C
Temp. and Humidity Controller "J" CS9BE-THO "K" CS9BE-THOC
1
Purple/White
Line 2
Plug #2
Red/White
D/YO
43
74
Red
"J" Or "K" Thermostat Option
Plug #2 Temp. and Humidity Controller PART #8403-060
Black
79
"E" Thermostat Option
Line 3
Black
74
Circuit Breaker
55
Yellow Yellow
L3 L2 L1 Black
208/230-60-3 220/240-50-3 Per Nameplate
30
Brown
Blue
1
Heater Contactor #1
To Power Source
67
Blue