COMPOSITE WIRING DIAGRAM 230/208/60-3 L Pink CO2 Controller Part #8403-056 Brown A Brown/White Purple G Orange A Brown/White G Orange Y1 Yellow O/B Blue W2 Brown PLUG #2 1 2 R Red/White C Black/White L Pink 3 4 C Black/White 8 L Pink 9 Temp. and Humidity Controller Part #8403-060 7 10 11 240V C COM 2 3 4 5 6 7 8 9 10 11 12 PLUG #1 Red 24VAC Red Black Black Yellow Brown Analog Out Yellow Orange Green 1 2 3 4 5 6 Brown Orange "D" THERMOSTAT OPTION Green CO2 Controller Part #8403-056 RED BLACK GREEN RED/WHITE PINK BROWN/WHITE BROWN BLUE PURPLE/WHITE GRAY 31 33 18 Check Light "H" THERMOSTAT OPTION 4115-101 3 4 24 CC ALR R Y C 1 38 4 5 3 2 1 BLACK/ WHITE 39 RED 27 12 PIN VENT PLUG 39 35 35 36 36 12 11 10 9 8 7 6 5 4 3 2 1 Factory Field 2 Comp. Control Module HPC 27 39 34 LPC LPC PINK YELLOW 32 230/208 VOLT PACKAGE UNIT DIAGRAM 1 12 4115-100 YELLOW ORANGE 2 R 1 42 PINK 44 43 BLUE Optional High Speed Solenoid 1 BLUE BLACK/WHITE 48 Reversing Valve Brown W2 41 RED BLACK YELLOW Low Voltage Blue O/B Red/White 6 39 High Voltage Yellow Y1 R 5 BLACK/WHITE GREEN BLACK/WHITE PLUG #2 L3 BLACK/WHITE Purple Red/Yellow L2 T1 T2 T3 ORANGE 4115-102 L1 L1 L2 L3 38 27 BROWN Red/Yellow Y2 Y2 BLACK/WHITE BLACK/WHITE 15 Transformer "X" THERMOSTAT OPTION C Phase Monitor 37 YELLOW/RED 208V Green W1/E 39 RED/WHITE 27 6 PIN CO2 PLUG Orange 21 33 RED/ WHITE 38 40 Y Yout 48 38 YELLOW 4 5 6 Yellow 1 2 3 Black W1/E LOW VOLTAGE STRIP RED/WHITE RED/WHITE Red Black Yellow Brown Orange Green 24VAC Temp. and Humidity Controller Part #8403-060 12 10 2 4 19 Compressor Contactor RED/WHITE Terminal Strip Red Analog Out BLOWER VENT RELAY 5 10 34 10 1 3 14 BLACK/ WHITE 10 FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS FOR 208V OPERATION, MOVE THIS RED WIRE TO 208V TRANSFORMER TAP REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED RED L2 L1 YELLOW L BROWN/ WHITE 10 BLACK/WHITE Black/White 10 YELLOW C 30 10 YELLOW C BROWN ORANGE 4 Ground Terminal YELLOW Red/White 27 BLUE R YELLOW RED R 4 YELLOW RED W2 PURPLE ORANGE BLUE 7 8 9 10 11 12 W2 Brown BLUE Blue Circuit 5 Breaker RED O RED/YELLOW YELLOW O/B BLACK 29 YELLOW/BROWN Yellow RED Y1 PURPLE Y1 RED 28 BLUE/WHITE Orange BLACK/WHITE G L1 L2 L3 BLACK G RED/WHITE Brown/White BROWN/WHITE A BLACK/ WHITE 208/230-60-3 POWER SOURCE 11 5 PIN PLUG FOR INDOOR BLOWER MOTOR 3 4 5 YELLOW A 12 PIN PLUG FOR THERMOSTAT 10 4 5 6 O1 Y Y1 C Purple Terminal Block #1 ("A" Ctrl. Opt. Only) PURPLE C Y2 3 O1 Y Y1 C BROWN NC Y2 BLACK/WHITE NO Red/Yellow BLACK/WHITE C E 14 12 15 3 1 10 6 9 13 2 BLACK/W NC PWR W1/E 16 PIN PLUG FOR INDOOR BLOWER MOTOR 10 1 2 3 NO HVAC Low Voltage Terminal Strip PURPLE AREA OCCUPIED Temp. and Humidity Controller Part #8403-060 RED/WHITE Optional CS2000A Energy Monitor (Use With "A" Thermostat Only) Hi Pressure Control L3 Low Pressure Control Low Pressure Control YELLOW Compressor 4113-200 Wire Identification numbers 99 for Bard use only. REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. Bard Mfg. Co. Bryan, Ohio 4113C200