Transcript
COMPOSITE WIRING DIAGRAM 460/60-3
Y2
39
240V
C
COM
Purple
G
Orange
Y1
Yellow
O/B
Blue
Brown/White
G
Orange
Y1
Yellow
O/B
Blue
W2
Brown
PLUG #2 1 2
R
Red/White
C
Black/White
L
Pink
3 4
R
Red/White
C
Black/White
8
L
Pink
9
Temp. and Humidity Controller Part #8403-060
5 6 7
10 11
1 2 3 4 5 6 7 8 9 10 11 12
Brown
W2
PLUG #1
12
Red 24VAC
Red Black
Black
Yellow Brown
Analog Out
Yellow
Orange Green
1 2 3 4 5 6
Brown Orange
"D" THERMOSTAT OPTION
Green
4115-100
CO2 Controller Part #8403-056
32 39
RED
"H" THERMOSTAT OPTION
4115-101
RED
BLACK
18 Check Light
BLACK/WHITE
YELLOW
YELLOW/BROWN
RED BLACK
45
2 1
BLACK/ WHITE 39
45
35
BLACK
PINK YELLOW 33 27
20
35
36
36
27
12 PIN VENT PLUG
12 11 10 9 8 7 6 5 4 3 2 1
460 VOLT PACKAGE UNIT DIAGRAM
3 REMOVE WIRE FROM TERMINAL Y2 AND TAPE OFF WHEN LOWER FULL LOAD CFM DESIRED
MODEL QW2S QW3S QW4S QW5S
19
4 5
3
High Speed Solenoid
BLUE BLUE
BLACK/WHITE
PURPLE
BLACK/WHITE
BLUE/WHITE
48
1
Reversing Valve
YELLOW
R
31
1
LPC LPC
39
Compressor Contactor
C
Y 38
YELLOW
GREEN
2 REMOVE JUMPER WHEN CS2000 ENERGY MONITOR IS INSTALLED PLUG #2
T1 T2 T3 BLACK/WHITE
CC ALR
R
YELLOW
ORANGE
Purple Brown/White
HPC
RED
BLACK/WHITE
Red/Yellow
A
L1 L2 L3
38
27
BROWN
BLACK/WHITE
4115-102
37
RED
YELLOW
1 FOR ANTIFREEZE LOOP APPLICATIONS, CHANGE LOW PRESSURE SWITCH TO YELLOW LEADS ON YELLOW WIRES COMING OFF OF COMPRESSOR CONTROL MODULE "LPC" TERMINALS
Red/Yellow
A
39
RED/WHITE
BLACK/WHITE
15 Transformer
"X" THERMOSTAT OPTION
42
Comp. Control Module YELLOW/RED 24
43
BLACK
PINK 34
44
L3
48
208V
Green
L2
RED
38
33
RED/ WHITE
38
RED/WHITE
27 6 PIN CO2 PLUG
Orange
Y2
LOW VOLTAGE STRIP
L1
41 RED BLACK YELLOW
RED
Yellow
1 2 3 4 5 6
Red Black Yellow Brown Orange Green
Brown
W1/E
10
BLACK
C
21 Phase Monitor
YELLOW
RED/WHITE
Black
W1/E
2
12
Y
Yout
BLUE
4
40
RED/WHITE
Red
Temp. and Humidity Controller Part #8403-060
BLO W ER VEN T R ELAY
5
10
34
10
BLUE
14
BLACK/ WHITE
10
10 1
3
Terminal Strip
24VAC
Analog Out
10
4 Ground Terminal
Fuse Block
CO2 Controller Part #8403-056
Pink
BROWN/ WHITE
YELLOW
30
10
ORANGE
GREEN
L
Black/White
BROWN
5 Rotary Disconnect 27
BLACK BLACK
L
O1 Y Y1 C
Red/White
RED
C
7 8 9 10 11 12
C
BLUE
PURPLE
RED
R
GREEN
R
Brown
ORANGE YELLOW
RED
W2
BLACK/ WHITE
W2
29 46 Term. Block
RED/YELLOW
RED/WHITE
Blue
RED/WHITE
O
RED BLACK
28
BROWN/WHITE
O/B
PINK
Yellow
460-60-3 POWER SOURCE L1 L2 L3
11 5 PIN PLUG FOR INDOOR BLOWER MOTOR
3 4 5
3
YELLOW
Y1
BROWN/WHITE
Y1
BROWN
Orange
BLUE
G
PURPLE/WHITE
G
12 PIN PLUG FOR THERMOSTAT 10
GRAY
Brown/White
YELLOW
A
ORANGE
A
BLACK/WHITE
Purple
PURPLE
C
Y2
Terminal Block #1 ("A" Ctrl. Opt. Only)
BROWN
NC
Y2
BLACK/WHITE
NO
Red/Yellow
3
O1 Y Y1 C
BLACK/WHITE
C
E
14 12 15 3 1 10 6 9 13 2
BLACK/W
NC
W1/E
16 PIN PLUG FOR INDOOR BLOWER MOTOR 10
1 2 3 4 5 6
NO
PWR
HVAC
Low Voltage Terminal Strip
PURPLE
AREA OCCUPIED
Temp. and Humidity Controller Part #8403-060
RED/WHITE
Optional CS2000A Energy Monitor (Use With "A" Thermostat Only)
Step Down Transformer
RED
STEPDOWN TRANSFORMER CLASS CC FUSE W / ERV NO ERV 5 3.2 5 3.2 7 3.2 7 5
High Voltage Low Voltage
Hi Pressure Control
L2 L1
L3
Low Pressure Control
YELLOW
Compressor
Factory Field
Low Pressure Control
BLACK
4113-300
Wire Identification numbers 99 for Bard use only.
Optional !
DANGER
*ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
!
WARNING
USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C.
Bard Mfg. Co. Bryan, Ohio
4113C300