4116-109

   EMBED


Share

Transcript

10 2 (3) Thermal Cutoffs 8 4 9 Limit Switch 6 Heat Strip 1 4 3 5 17 L1 36 L2 Black/White L1 2 14 23 Circuit Breaker 2 Blue Blue 23 Red Circuit Breaker 1 2 or 3 37 12 Ground Red/White Circuit Breaker 2 Heater Contactor #1 L1 T1 Heater Circuit Breaker 1 Contactor #2 L2 T2 Line 2 to Power Source 4 2 Thermal Cutoff 1 Heat Strip Thermal Cutoff 3 Heat Strip Thermal Cutoff 5 2 4 6 4 2 Blower Int. Relay 6 Black/White 3 Blue 2 6 1 3 4 5 Ground Circuit Breaker 2 Circuit Breaker 1 Blower Int. Relay Limit Switch Orange 4 6 Pin Plug Heat Strip 1 Black Red Brown 31 32 Lug 13 Heater Contactor #1 L2 T2 230/208-60-1 Power Source L2 1 Ground 1 Line 2 to Power Source 4 Line 1 to Power Source 2 Ladder Diagram 230/208-60-1 Power Source Line 1 to Power Source Terminal Block 5 T2 T1 20 L2 L1 Ckt B T2 T1 27 L2 L1 Ckt A Blk/Wht 18 Brown 3 11 Heater Contactor #2 1 Blue Heater Contactor #1 34 Blower Interlock Relay ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. 16 Brown 35 Heater Package Assembly 6 Pin Plug for Optional Heater Package 1 3 4 5 H. Contactor #1 H. Contactor #2 Line 2 3 Red Blue 15 4116-109 ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. Brown Standard Diagram 22 Heat Strip Black Blue 21 1 Line 1 Blue 5