Transcript
2
4116-204
10
(4) Thermal Cutoffs
Heater Package Assembly 9
4
Heat Strip #1 9kw
1
5
3
Limit Switch
Red
Red
Blue
5
! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING.
21
17
6
Heat Strip #2 6kw or 9kw
27
Black
8
22
Standard Diagram
! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C.
4
3
28
11
230/208-60-3 Power Source
Line 1 Line 2 Line 3
1
Circuit Breaker
18
Ladder Diagram
L2 Brown
2
4
1
L2
L1
32
1
L2
L1
16
20
29
15
5
16
Black
Line 2
15
Red
Line 1
2 Thermal Cutoff
Line 3
Red
Heat Strip #2
6
230/208-60-3 Power Source
Black/White Black
T1
Thermal Cutoff
L2
3
T2
Heat Strip #1
Heater Contactor #1
Circuit Breaker
L1
2
Thermal Cutoff 1
T1
14 12
13
1 Yellow
3
Red
Red/White
Blue
Black
4 2
Black/White
4 6 Pin Plug
Brown
4 2 Blower Int. Relay
6 3
2
6
1
3
Blower Int. Relay
Limit Switch
Orange
4
5
Line 1 Line 2 Line 3
5
T2 T1
To Power Source
T2 T1
Thermal Cutoff
Yellow
Blk/Wht
Yellow
3
Heater Contactor #2
Blower Interlock Relay
1
L1 Heater Contactor #1
30
Blue
4
Heater Contactor #2
Black
31
T2
6 Pin Plug for Optional Heater Package
1
3
4
5
H. Contactor #1
H. Contactor #2