Preview only show first 10 pages with watermark. For full document please download

42111

   EMBED


Share

Transcript

42111 1.0 Power Switch Twin Plus Cascadable remote power switch with auto-reboot - 2 IEC320 inputs and 2x4 IEC320 outputs - control the outputs via RS-232/V.24 or IP (HTTP) - cascadable up to 40 ports - monitors and automatically restarts the attached servers and appliances Power Switch Twin Plus is a power distribution and control unit that enables remote power management of 8 devices over Intranet, Internet or locally through an RS-232 serial connection. The number of controlled power outlets can be extended up to 40 by cascading up to 4 Secure Power Switch Satellite (PSE518SA-xx) models. On, Off and Restart functions 8 to 40 power outlets can be turned On/Off or restarted over IP or through an RS-232 serial connection. Two separate AC Power Inputs This feature enables the use of 2 power inputs sources (UPS for example) to provide servers with redundant power supplies. It improves the security and increases the total current load. Twin Mode This mode allows to group the outlets 2 by 2. A pair of power outlets can be controlled in one shot. Ideal for servers with redundant power supplies. Access rights: up to 40 user accounts The server access is protected by names and password. The administrator has access to the Power Switch Twin Plus configuration and the control of all power outlets. He also specifies the user access rights for the control of 1 to 8 power outlets. IP Security 8 security masks are used to grant or deny access to one specific IP address or to a group of IP addresses. Syslog messages Event logs can be sent to a Syslog Server. 42111 1.0 Power Switch Twin Plus Cascadable remote power switch with auto-reboot On Line Help A contextual on line help can be used at all times. DHCP Client This option can be used to reduce the configuration management. Programmable restart delay The administrator can set a restart delay for each power outlet (between 1s and 60s). Furthermore, he can define the outlet default status after a power failure. Sequential power up/down The outlets are sequentially started to avoid inrush current. Automatic reboot of IP devices This function enables the monitoring of up to 8 IP devices (Ping or Scan command) with an automatic reboot in case of lock-up. Labels To avoid confusions, the administrator can define a label to each unit and its power outlets. Developer facility Developers can use the hidden page functionality for an easy implementation of the power outlet control through the network in their own programs. Easy and fast configuration The configuration can be done: - through a standard web browser, - through a serial console interface, - through the BBFinder convenient Windows tool. 42111 1.0 Power Switch Twin Plus Cascadable remote power switch with auto-reboot Connections Power input: (2) IEC 320 C14 Power output: (8) IEC 320 C13 Serial management and control: (1) DB9 F RS-232/V.24 Network management and control: (1) RJ-45 F 10BASE-T Connection bus: (1) RJ-45 F RS-485 Engine Input voltage: 230 VAC nominal Input frequency: 50Hz nominal Output voltage: same as input voltage Output frequency: same as input frequency Max. total load: 2 x 10 A Max. inrush current: 120 A Power switching: relay-based, only for live wire Control logic: proprietary system Features: delayed reboot, per port default power-up state, automatic reboot by ping or port scan timeout (configurable) Management Indicators: (1) input status per input, (1) output status per output, (1) LAN speed, (1) power, 42111 1.0 Power Switch Twin Plus Cascadable remote power switch with auto-reboot (4) satellite connection status Setup and configuration: Windows configuration tool, RS-232 serial via terminal emulation, HTTP via web browser Output control: RS-232, HTTP Features: delayed reboot, default power-up state, automatic reboot based on ping (ICMP echo request) or port scan timeout Notification and alerts: syslog Security: user/password protected access, admin/user, up to 40 users, IP address filtering, configurable HTTP port, auto-logoff Other features: DHCP client Physical and environmental Power supply: internal, redundant Dimensions (W x H x D): 43.7 x 10.7 x 4.2 cm Weight: 2 kg Operating temperature range: 0 to 40°C Operating humidity range: 10 to 80% RH, non-condensing Enclosure: metal Convection: passive Article PSE510MA-EU PSE510MA-CH PSE510MA-UK Article Power Switch Twin Plus, Schuko Power Cord Power Switch Twin Plus, SEV Power Cord Power Switch Twin Plus, UK Power Cord