Preview only show first 10 pages with watermark. For full document please download

4241002 5275639 Web

   EMBED


Share

Transcript

HOT WATER SYSTEMS www.thermann.com.au 16800_Thermann_Brochure_V6_050814.indd 1 15/08/14 11:19 AM GAS STORAGE HOT WATER SYSTEM THE THERMANN 4* GAS HOT WATER HEATER CAN SUIT ANY FAMILY TYPE. WITH AN ADJUSTABLE THERMOSTAT FOR SAFETY AND EFFICIENCY IT ALLOWS YOU TO BE IN CONTROL OF YOUR OPERATING COSTS AND422 PERFORMANCE. THE UNIT HAS A SMALL FOOTPRINT WHICH MAKES 162 IT IDEAL FOR REPLACING A 3* CHANGEOVER. 502 B A GAS INLET 422 162 502 D C (219) 477 SPECIFICATIONS B Gas Tank Selecting the right unit for you A Net Weight Empty (kg) 80 86 1400 1400 135NG = 23.5 170NG = 27 Relief Valve Pressure (kPA) Gas Consumption (MJ/h) 135LPG = 22.5 104 119 First Hr Delivery 239 289 Dimensions (mm) 135L 170L Height (A) 1601 1895 Hot Water Outlet (B) 1325 1620 Cold Water Inlet (C) 220 220 Gas inlet (D) 299 299 Water Inlet/Outlet Dual Dual 3-4 4-5 No. People AL 7 YEAR IT Y C G UARA N Cylinder Recovery rate@45degC rise (L/hr) 170L AL 1 YEAR IT Y E 170 135L TE 135 E Capacity (litres) QU 170L QU 135L TE Measurements G UARA N Parts and labour 2 16800_Thermann_Brochure_V6_050814.indd 2 15/08/14 11:19 AM ELECTRIC LARGE HOT WATER SYSTEM THERMANN ELECTRIC STORAGE HOT WATER UNITS ARE AN INSULATED STORAGE VESSEL EFFICIENTLY STORING HOT WATER, READY FOR USE, WHEN YOU NEED IT. THE THERMANN RANGE OF ELECTRIC WATER HEATERS OFFER SOLUTIONS IN EIGHT DIFFERENT SIZES TO SUIT YOUR NEEDS. UPGRADE THE 250L, 315L OR 400L TANK TO SUIT SOLAR WHEN YOU’RE READY. B 25° TOP SENSOR 32° K A SOLAR RETURN C BOTTOM SENSOR F G FLOW H D J E SPECIFICATIONS Selecting the right unit for you 315L 400L Total Height (A) 925 1090 1345 1445 1765 1705 Total Diameter (B) 490 530 530 620 620 705 Outlet Height (C) 735 865 1120 1210 1530 1445 Inlet Height (D) 160 190 190 195 195 220 Electrical Entry (E) 85 100 100 105 105 130 Top Sensor (F) N/A N/A N/A 770 865 830 Solar Return (G) N/A N/A N/A 565 555 545 Bottom Sensor (H) N/A N/A N/A 355 350 350 Flow (J) N/A N/A N/A 195 195 220 Element Angle (K) 70° 70° 70° 70° 70° 70° Storage Capacity (litres) 88 130 165 259 321 415 Hot Water Delivery (litres) 80 125 160 250 315 400 Net Weight Empty (kg) 41 51 61 72 93 115 Element Size (kW) 3.6 3.6 3.6 3.6 1.8, 3.6 2.4, 3.6 Relief Valve Pressure (kPa) 1000 1000 80L 125L 160L Inlet/Outlet Dual Handed Dual Handed Dual Handed No. People (continuous) 2-3 3-4 3-5 0 0 1-3 250L 315L 400L Inlet/Outlet Left* Left* Left* No. People (continuous) 3-5 4-6 5-9 No. People (off peak) 1-3 2-4 4-6 No. People (off peak) *solar upgradeable AL 7 YEAR IT Y G UARA N Cylinder 1000 1000 1000 1000 AL 1 YEAR IT Y E 250L TE 160L E 125L QU 80L QU Measurements TE Electric Tank G UARA N Parts and labour Max Inlet Pressure Without an ECV (kPa) With an ECV (kPa) 16800_Thermann_Brochure_V6_050814.indd 3 800 800 800 800 800 800 650 650 650 650 650 650 3 15/08/14 11:19 AM ELECTRIC SMALL HOT WATER SYSTEM THERMANN SMALL ELECTRIC STORAGE HOT WATER UNITS ALLOW YOU TO INSTALL HOT WATER WHERE SPACE AND ACCESS IS RESTRICTIVE. WITH ITS “V FIT” CONFIGURATION, INLETS AND OUTLETS ARE CONFIGURED FOR EASE OF INSTALLATION. AVAILABLE IN ‘APPLIANCE WHITE’ FOR A MORE AESTHETICALLY PLEASING UNIT. SPECIFICATIONS Selecting the right unit for you Total Height (A) 455 695 Total Diameter (B) 405 405 Outlet Height (C) 280 520 Inlet Height (D) 155 155 Electrical Entry (E) 65 65 Element Angle (K) 70° 70° 53 50 Net Weight Empty (kg) 17 23 Element Size (kW) 2.4*, 3.6 2.4*, 3.6 Inlet/Outlet Dual Handed Dual Handed No. People (continuous) 1 1-2 No. People (off peak) 0 0 AL 7 YEAR IT Y G UARA N Cylinder QU 31 25 50L QU Storage Capacity (litres) Hot Water Delivery (litres) 25L AL 1 YEAR IT Y E 50L TE 25L E Measurements TE Electric Tank G UARA N Parts and labour Relief Valve Pressure (kPa) 1000 1000 Max Inlet Pressure Without an ECV (kPa) With an ECV (kPa) 800 800 650 650 *2.4kw plug in only 4 16800_Thermann_Brochure_V6_180814.indd 4 18/08/14 4:27 PM CONTINUOUS FLOW 5* HOT WATER SYSTEMS THE THERMANN 5* GAS CONTINUOUS FLOW SYSTEM HEATS WATER AS IT FLOWS THROUGH A COILED PIPE AROUND A GAS BURNER, WHICH MEANS YOU’LL NEVER RUN OUT OF HOT WATER. 350 350 165 165 8.812 1515 585 585 2525 Recess Box Painted 8484 COLD INLETR1/2 /15 COLD WATER WATER INLET WATER INLET FILTER INLET FILTER GAS SUPPLY INLET GAS SUPPLY INLET R3/4 /20 CABLE ENTRY POINT CABLE ENTRY POINT 65 60 WATER HOTHOT WATER OUTLET OUTLET R1/2 /15 71 35 31 623 619 575 575 8 8 13 13 50505050 PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE 330 330 12 165 Bathroom/Ensuite Controller Kitchen Controller 15 8 13 68 350 198 50 50 278 SPECIFICATIONS 20L 125 160 Test point pressure NG (kPa) 0.4 0.56 Test point pressure LPG (kPa) 0.4 0.61 26L 200 0.68 35 Nominal hourly gas consumption (MJ/h) 585 16L 575 Measurements 623 Continuous Flow 5* 25 84 0.7 Accessories Code Kitchen controller with 15m cable 9504157 Bathroom controller with 15m cable 9504158 Ensuite controller with 15m cable 9504159 Recess Box Gal 9504553 COLD WATER INLETR3/4 /20 Minimum water pressure (kPa) 260 260 210 Maximum water pressure (kPa) 1200 1200 1200 Minimum gas inlet pressure (kPa) NG 1.13 LPG 2.75 NG 1.13 LPG 2.75 NG 1.13 LPG 2.75 Maximum gas inlet pressure (kPa) NG 5.0 LPG 7.0 NG 5.0 LPG 7.0 NG 5.0 LPG 7.0 Minimum Flow Rate Ignition (l/min) 2.7 2.7 2.7 No. Bathrooms Input voltage single phase 50Hz (v) 240 240 240 9504555 HOT WATER OUTLET R3/4 /20 GAS Bracket SUPPLY INLET Locking 9504554 R3/4 /20 PRESSURE RELIEF VALVE 330 Selecting the right unit for you 16L 20L 26L 1 1-2 2-3 Energy Rating (Stars) 5.2 5.3 5.8 Capacity @ 25° rise (L/min) 16L 20L 26L 0.45 0.47 Inlet gas connection male thread R3/4" (20mm) R3/4” (20mm) R3/4” (20mm) Cold water connection male thread R1/2" (15mm) R1/2" (15mm) R3/4" (20mm) Capacity @ 40° rise (L/min) 10 12.5 16.25 Hot water connection male thread R1/2" (15mm) R1/2" (15mm) R3/4" (20mm) Gas Type Available NG, LPG NG, LPG NG, LPG Relief valve pressure setting (kPa) 1400 1400 1400 16 16 17 575x350x165 575x350x165 575x350x165 SAIG Approval certificate no. GSCS20021. Watermark Certificate of compliance WMKA 00506 16800_Thermann_Brochure_V6_180814.indd 5 YEAR IT Y G UARA N AL 3 YEAR IT Y E AL TE 10 QU Dimensions (HxWxDmm) E Weight dry (kg) QU 0.42 TE Maximum output current (A) Recess Box Painted WATER INLET FILTER CABLE ENTRY POINT G UARA N Heat Exchanger Parts and labour 5 18/08/14 4:28 PM CONTINUOUS FLOW 6* HOT WATER SYSTEMS THE THERMANN 6*, ENERGY EFFICIENT GAS CONTINUOUS FLOW UNIT ENSURES YOU WILL HAVE ENOUGH HOT WATER, WHEN YOU NEED IT. WITH A 12 YEAR WARRANTY, YOU CAN REST ASSURED YOU ARE COVERED FOR THE LIFE OF THE UNIT, AND UNIVERSAL CONTROLLERS ENSURE YOU ALWAYS HAVE PRECISE CONTROL OF YOUR HOT WATER TEMPERATURE SETTINGS. 15mm 200mm 12mm 200mm 12mm 12mm 546mm Recess Box Painted 68mm 68mm 39mm 68mm 15mm 546mm 584mm 520mm 584mm 520mm 39mm 12mm 68mm350mm 68mm 68mm 25mm 25mm 350mm 68mm 68mm COLD WATER INLET R3/4 /20 POWER CABLEPOWER ENTRY CABLE ENTRY REMOTE CONTROLLER CABLE ENTRY REMOTE CONTROLLER WATER INLET FILTERCABLE ENTRY PRESSURE RELIEF VALVE HOT WATER OUTLET R3/4 /20 HOT WATER OUTLET R3/4 /20 PRESSURE RELIEF VALVE COLD WATER INLET 334mm R3/4 /20 100mm 80mm 69mm WATER INLET FILTER GAS SUPPLY INLET R3/4 /20 GAS SUPPLY INLET R3/4 /20 SPECIFICATIONS Universal Controller 46mm 174mm 260mm 334mm Continuous Flow 6* Measurements 16L 20L 26L Accessories Code Nominal hourly gas consumption by proportional electronic gas control (MJ/h) 125 158 200 Thermann Universal Controller 9505082 6* Recess Painted Box 9505219 6* Recess Box Gal 9505218 6* Locking Bracket 9504679 6* Flue Diverter 9505161 Test point pressure (Propane) (kPa) 0.91 1.4 1.5 Minimum water pressure (kPa) 60 90 110 Maximum water pressure (kPa) 1200 1200 1200 Minimum gas inlet pressure (kPa) NG 1.13 LPG 2.75 NG 1.13 LPG 2.75 NG 1.13 LPG 2.75 Maximum gas inlet pressure (kPa) NG 5.0 LPG 7.0 NG 5.0 LPG 7.0 NG 5.0 LPG 7.0 Minimum Flow Rate Ignition (l/min) 2.7 2.7 2.7 Input voltage single phase 50Hz (V) 240 240 240 Maximum output current (A) 0.39 0.45 0.46 Inlet gas connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Cold water connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Hot water connection male thread R3/4" (20mm) R3/4" (20mm) R3/4" (20mm) Relief valve pressure setting (kPa) 1400 1400 1400 Weight dry (kg) Dimensions (HxWxDmm) 15 15 16 520x350x200 520x350x200 520x350x200 16800_Thermann_Brochure_V6_180814.indd 6 20L 26L 1 1-2 2-3 Energy Rating (Stars) (50°C) 6.3 6.5 6.1 Energy Rating (Stars) (60°C) 6.0 6.0 6.0 Capacity @ 25° rise (L/min) 16L 20L 26L Capacity @ 40° rise (L/min) 10 12.5 16.25 NG, LPG NG, LPG NG, LPG Gas Type Available 12 AL YEAR IT Y G UARA N QU 6 16L No. Bathrooms QU SAIG Approval certificate no. GSCS20021. Watermark Certificate of compliance WMKA 00506 Selecting the right unit for you AL 3 YEAR IT Y E 0.8 TE 0.8 E 0.56 TE Test point pressure (Natural Gas) (kPa) G UARA N Heat Exchanger Parts and labour 20/08/14 1:27 PM EVACUATED TUBE SOLAR ELECTRIC BOOSTED THERMANN EVACUATED TUBE SOLAR ELECTRIC BOOSTED SYSTEMS HARNESS THE SUN’S ENERGY TO HEAT YOUR WATER. AN ELECTRIC ELEMENT IN THE TANK PROVIDES BACK UP IF NEEDED, ENSURING PEACE OF MIND, WHILST ALSO REDUCING YOUR RUNNING COSTS. A HW Outlet A B PTRV Top Sensor Solar Return B Bottom Sensor Flow Inlet SPECIFICATIONS Selecting the right unit for you Tank Diameter (A) 540 648 648 648 648 731 731 Tank Height (B) 1494 1388 1388 1682 1682 1731 1731 HW Outlet 1292 1167 1167 1470 1470 1474 1474 PTRV Port 1292 1167 1167 1470 1470 1474 1474 Top Sensor Port 1048 759 759 841 841 841 841 Solar Return Port 804 564 432 564 509 564 564 Bottom Sensor 489 369 303 369 342 369 369 Solar Flow 174 174 174 174 174 174 174 Cold Water Inlet 74 74 74 74 74 74 74 Dry Weight (kg) 61 86 86 98 98 130 130 160L 250L 315L 400L No. People 1-2 3-5 4-6 5-9 No. Tubes 10 22 30 44 *Other kit configurations available 15 AL YEAR IT Y G UARA Tubes N 10 AL YEAR IT Y G UARA Tank N AL 1 YEAR IT Y E 400L MID TE 400L BOT E 315L MID TE 315L BOT E 250L MID QU 250L BOT QU 160L BOT QU Measurements (mm) TE Electric Boosted Tank G UARA N Parts and Labour Roof Collector Measurements (mm) Dry Weight Collector Width (A) Length (B) WO/Tubes W/Tubes 10 Tubes 945 2025 10.5kg 40.5kg 22 Tubes 1636 2025 20kg 85kg 30 Tubes 2240 2025 24kg 112kg Dry weights based on 3 track flush mount frame. 16800_Thermann_Brochure_V6_050814.indd 7 7 15/08/14 11:20 AM EVACUATED TUBE SOLAR GAS BOOSTED THERMANN EVACUATED TUBE SOLAR GAS BOOSTED SYSTEMS OFFER RELIABILITY AND EFFICIENCY. PASSIVE SUN TRACKING MEANS MORE OF THE SUN’S RAYS ARE CONVERTED TO USABLE HOT WATER THROUGHOUT THE DAY - REDUCING YOUR POWER BILLS. WITH THE GAS BOOSTED CONTINUOUS FLOW UNIT, YOU’LL NEVER RUN OUT OF HOT WATER, NO MATTER THE WEATHER. A HW Outlet A PTRV 350 15 8 13 Solar Return Bottom Sensor 585 B 165 Top Sensor 619 575 B 8.8 5050 31 Flow Inlet 84 25 SPECIFICATIONS 648 648 731 Tank Height (B) 1502 1389 1682 1721 HW Outlet 1300 1167 1470 1464 PTRV Port 1300 1167 1470 1464 Top Sensor Port 1056 953 1196 1207 Solar Return Port 812 740 922 950 Bottom Sensor 497 457 548 562 182 174 174 174 Cold Water Inlet 82 74 74 74 Dry Weight (kg) 61 86 98 130 400L No. People 1-2 3-5 4-6 5-9 No. Tubes 10 22 30 44 26L 26L 26L 26L Gas Booster 15 AL YEAR IT Y G UARA Tubes N 10 QU Solar Flow 315L AL YEAR IT Y G UARA Tank N AL 1 YEAR IT Y E 540 250L TE Tank Diameter (A) 160L E 400L GAS TE 315L GAS QU 250L GAS QU 160L GAS E Measurements (mm) Selecting the right unit for you TE Gas Boosted Tank G UARA N Parts and Labour For 26L Gas Continuous Flow specifications and warranty information refer to page 5. Roof Collector Measurements (mm) Dry Weight Collector Width (A) Length (B) WO/Tubes W/Tubes 10 Tubes 945 2025 10.5kg 40.5kg 22 Tubes 1636 2025 20kg 85kg 30 Tubes 2240 2025 24kg 112kg Dry weights based on 3 track flush mount frame. 8 16800_Thermann_Brochure_V6_050814.indd 8 15/08/14 11:20 AM EVACUATED TUBE SOLAR HOW IT WORKS STEP 1 H eat T rans f e r Heat Transfer The sunlight strikes the dark absorber coating inside the tube. STEP 2 en s liq ui d o st ise STEP 3 r ur po Va A circulator moves water from the storage tank to the warming the water. The Ab s o copper rb er C o at i npipe g solar heated water is then pushed down into the storage tank for use. Anti-frost is built in to V a cuum Sp ace the Thermann system to ensure solar hot water can be provided even in cold regions. d se en d on p to uid r o st rn u et bo liq C Absorber Coating Vacuum Space PASSIVE SUN TRACKING Midday Afternoon The round tube design of the system passively tracks the sun throughout the day giving the highest possible performance from early morning through to late afternoon. Morning ELECTRIC & GAS SETUPS Electric Booster Gas Booster Thermann Solar Collector Thermann Solar Collector Thermann Solar Collector Storage Tank Storage Tank Solar Return Solar Return Solar Return Pump Station Pump Station Solar Flow C d on ed Solar Flow po es m tto r Solar Flow Va ris ur to m transfers the heat up to the The heat pipe to ot b coppert oheader pipe location in the insulated ns p box. ur t o manifold et Evacuated tube absorbs sunlight and converts to usable heat Storage Tank Pump Station Hot water to house Gas Booster Hot water to house Hot water to house Cold Inlet Cold Inlet Cold Inlet Note: Diagram not to scale - basic system overview (not installation guide). Note: Diagram not to scale - basic system overview (not installation guide). Note: Diagram not to scale - basic system overview (not installation guide). 9 16800_Thermann_Brochure_V6_050814.indd 9 15/08/14 11:20 AM HEAT PUMP HOT WATER SYSTEM 30-60 1267 670 1267 185 30-60 18530° 16°12° 30-60 670 670 185 30-60 670 AVAILABLE IN WESTERN AUSTRALIA ONLY 30° 16°12° 30° 16°12° SPECIFICATIONS 30° 16°12° 1267 1840 1840 1840 1638 1638 1638 1638 1840 MADE IN GERMANY, THE THERMANN HEAT PUMP EXTRACTS HEAT FROM AMBIENT AIR AND QUIETLY TRANSFERS IT TO HEAT WATER. IT COMES WITH A REMOVABLE INTAKE GRILL FOR EASY CLEANING AND SERVICING WHERE ACCESS IS LIMITED. Heat output kW Dimensions mm Heating output at A15/W15-55 1.7 Height of unit when tilted 1990 Power consumption kW Height when tilted incl. packaging Power consumption at A15/W15-55 0.5 Height (adjustable feet) Sound data Sound pressure level at 1 m distance in a free field Energy data Standby energy consumption/24 h at 65 °C dB(A) Diameter 56 2200 1870-1900 670 Weights kg kWh Weight (dry) 125 1.14 Weight (wet) 428 Weight 125 Electrical details Fuses C 10 A Connections mm Rated voltage 240 V Condensate drain 20 Phases 1/N/PE Water connection G 1 (with adaptor Rp 3/4 female) Frequency 50 Hz Values Rated current 2.5 A Air flow rate 550 m3/h Lower air temperature limit 0 °C Max. power consumption 700 W Upper air temperature limit 42 °C 10 16800_Thermann_Brochure_V6_050814.indd 10 G UARA N Cylinder AL 1 YEAR IT Y TE YEAR TE 5 IT Y QU QU AL E 700 W E Power consumption G UARA N Parts and labour 15/08/14 11:20 AM HEAT PUMP HOT WATER SYSTEM HOW IT WORKS COMPRESSOR High pressure High temperature vapour Low pressure Low temperature vapour FLOW ENVIRONMENTAL ENERGY CONDENSER EVAPORATOR HEATING ENERGY RETURN High pressure High temperature liquid Low pressure Low temperature liquid EXPANSION VALVE ESTIMATED PAYBACK PERIOD Estimated payback period for a TIHP300 Vs Conventional Electric Storage (WA)* $16,000.00 ELECTRIC STORAGE 315L $14,000.00 $12,000.00 $10,000.00 SAVINGS $8,000.00 TIHP300 $6,000.00 $4,000.00 $2,999 $2,000.00 $939 $0.00 PURCHASE PRICE YEAR 1 YEAR 2 YEAR 3 YEAR 4 YEAR 5 YEAR 6 YEAR 7 YEAR 8 YEAR 9 YEAR 10 *This estimated payback period for a TIHP300 heat pump compared to a conventional electric storage water heater is provided as a guide only. It should not be relied on exclusively for hot water system selection. Your personal requirements may be different to our assumption and as such may not provide you with an accurate comparison. Fixed charges, system access charges, delivery fees and any other charges, discounts or special rates have not been taken into account. You should consult with your energy provider and hot water specialist for more information. Graphed results included GST. Tariff cost is ex GST $0.25/kwh, 200L per day @ 60°C, air temperature 15°C. Cold water inlet temperature of 15°C. 11 16800_Thermann_Brochure_V6_050814.indd 11 15/08/14 11:20 AM www.thermann.com.au Reece. Works for you.™ Call 1800 032 566 or visit www.reece.com.au for your nearest Reece store. Due to limitations in the printing process the colours in this brochure are a guide only. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. The manufacturer/distributor takes no responsibility for printing errors. All products enjoy a product replacement warranty. For full warranty details visit www.reece.com.au/productquality V6 [BROCHURE CODE 2130530] 16800_Thermann_Brochure_V6_050814.indd 12 15/08/14 11:20 AM