Preview only show first 10 pages with watermark. For full document please download

4302-066-d-10-11 Quickstart 115vac

   EMBED


Share

Transcript

QUICKSTART “BASIC” GUIDELINES FOR 115 VAC STANDARD OR DELUXE CONTROL BOX FOR 6002, 6003, 6004 AND 6400 Control box is intended for installation only on automated gates used for vehicles. Main Terminal 120 Glasgow Avenue Inglewood, California 90301 U.S.A. D KEY SWITCH BUTTON: Cycles operator when pressed. Will use Auto-Close timer when turned ON. E RESET BUTTON: Resets circuit board. Circuit Board Settings Typical Settings with Plug-In Reverse, Shadow and Exit Loops Mounting Holes Shadow Loop Reverse loops wired in series To #8 To #11 SW 2 NO #1 ON #2 OFF NC 6 #8 - #11 Shadow Loop Output 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Antenna mounted outside control box. 15 x Ft Coa PRIMARY Operator Cable SECONDARY Operator Cable (Interconnection Cable) DO NOT cycle operator before limit sensors Com Telephone Entry Note: Must use a separate power source. and DIP-switches have been adjusted, damage could occur to gate and operator. Please refer to the Wiring/Owner’s manual for the 115 VAC Control boxes. Copyright 2011 DoorKing, Inc. All rights reserved. Low Voltage Key Switch (Dry contact) Coaxial Cable Antenna Kit P/N 1514-073 (Sold separately) Battery Plug CAUTION SW 1 Switch 3 MUST be ON. Mounting Hole Not included - Refer to a specific Radio Receiver Manual (available from www.dkaccess.com) for more information on radio receivers and antenna installation. RED g DoorKin e ir 3-W eiver RF Rec 5-081 5 0 8 P/N ON Keypad (Dry contact) Shadow Loop Jumper C RED 24V 5 Radio Receiver AC Power Switch Loop Wires Alarm Chassis Reset Ground Button Tip: Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation. Keep them in separate conduits. High Voltage Power Relay Com 12 V 3 Amp/Hr Battery Reversing Sensor Adjust Relay N.O. N.O. Three 115 VAC Convenience Outlets 12 V 3 Amp/Hr Battery B Com N.O. Deluxe Control Box 2 3 4 Note: Please refer to the Wiring/Owner’s manual. Not included - Refer to the Wiring/Owner’s manual AND Loop Information Manual (available from www.dkaccess.com) for more information on loops and plug-in loop detectors. Important Note: DoorKing highly recommends that loops and loop detectors are installed with this gate operator. A loop detection system will preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. Battery Plug BLK 115V WHT 1 ON D Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. 1 2 3 4 Primary Operator ONLY 1 2 3 4 Safety Opening Device Com (Dry contact) ON 1 2 3 4 5 6 7 1. Relay Control 2. Relay Control 3. Maglock 4. OFF Plug-In Loop Detectors SW 1 Com Power safety and opening devices that require 115 VAC power. #5 OFF SW 1 1. Direction Primary operator opens. 2. Direction Secondary operator opens. 3. Open Input 4. Auto-Close Timer B 5. Standard Reverse 6. Overlapping Gates 7. Single/Dual Operators Adjust11 to23 23 sec. 8. OFF SW 2 E A Secondary Operator Shadow Loop ONLY Settings: Note: Circuit board provides 24 VDC to power maglock. Contact rating is 1 amp maximum at 24 Volts. N.O. Common Switch 3 ON 1 2 3 4 5 6 7 8 4-Wire RF Receiver SW 2 1 2 3 4 5 6 7 8 Relay Com Power Com Secondary Entrapment Protection Device Connection N.O. Connect optional control devices to the main terminal. Use 18 AWG wire for all low voltage wiring, maximum distance 3000 feet. Use a low voltage surge suppressor, (DoorKing P/N 1878-010) if low voltage wire runs exceed 1000 feet. All control device inputs to the terminal must be NORMALLY OPEN. Relay N.C. ON Power Com ON 3-Wire RF Receiver Do not power any control devices from the circuit board other than low voltage devices. Magnetic Lock 1 2 3 4 Reversing input on Terminal #8 functions ONLY while the gate is at the FULL OPEN position or during the CLOSING cycle. It MUST NOT be used as an input for a secondary entrapment protection device during the OPENING gate cycle. Refer to Secondary Entrapment Protection Wiring in the Wiring/Owner’s manual. Dual Channel Reverse and Shadow Plug-In Loop Detector P/N 9409-010 Single Channel Exit Plug-In Loop Detector P/N 9410-010 A ON 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 24 VAC Input 24 VAC Input Low Voltage Common Alarm Reset Not Used 12 Volt Battery Input Not Used DC Lock Power Common 24 VDC Maglock Power Low Voltage Common 7 8 Dry Relay Contact Full Open 6 Dry Relay Contact Low Voltage Common 5 Low Voltage Common Full Open 2 3 4 Standard Reverse Full Open 24 VDC - 250 ma max. Low Voltage Common 1 Pedestrians must be supplied with a separate access opening. For safety and complete installation and adjustment instructions, please refer to the Wiring/Owner’s manual. 115 VAC Input Power Wire: Wire Size Distance 14 AWG 12 AWG Up to 200 ft Beyond 200 ft Black to transformer’s black (Hot). White to transformer’s white (Neutral). Green to chassis ground. Do not connect the battery plug to the circuit board until power is needed to test the operator. 115 VAC Connection BOX MUST BE DANGER CONTROL PROPERLY GROUNDED!! C HIGH VOLTAGE! White - Neutral Black - 115 VAC Hot Green - Chassis Ground Tip: It is recommended that a surge suppressor be installed on the high voltage power lines. Note: To turn-off ALL power to the operator, the AC power switch must be turned off AND the battery plug must be disconnected from the circuit board. 4302-066-D-10-11