Preview only show first 10 pages with watermark. For full document please download

43494e D9412g-d7412g Approved Apps Comp Guide.pmd

   EMBED


Share

Transcript

D9412G/D7412G Approved Applications Compliance Guide EN Control Panels D9412G/D7412G | Approved Applications Compliance Guide | Bosch Security Systems | 9/03 | 43494E EN | 2 D9412G/D7412G | Approved Applications Compliance Guide | Table of Contents EN | 3 Contents 1.0 1.1 1.1.1 1.1.2 1.2 1.3 1.3.1 1.3.2 1.3.3 1.3.4 2.0 3.0 3.1 3.2 3.3 3.4 3.5 3.6 4.0 4.1 4.2 5.0 5.1 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.2 5.2.1 5.2.2 5.2.3 5.2.4 Overview ................................................................................................................................................................................. 5 Listings and Approvals ......................................................................................................................................................... 5 Fire ............................................................................................................................................................................................ 5 Burglary ................................................................................................................................................................................... 5 Introduction ............................................................................................................................................................................. 5 Optional Compatible Equipment ...................................................................................................................................... 5 Burglary Applications ........................................................................................................................................................... 5 Bank Safe and Vault Applications .................................................................................................................................... 5 Fire Applications .................................................................................................................................................................... 5 Enclosures .............................................................................................................................................................................. 6 System Chart ......................................................................................................................................................................... 7 System Wiring Diagrams, Issue A .................................................................................................................................... 9 D9412G Control Panel, 1 of 3 ......................................................................................................................................... 9 D9412G Control Panel, 2 of 3 ....................................................................................................................................... 10 D9412G Control Panel, 3 of 3 ....................................................................................................................................... 11 D7412G Control Panel, 1 of 3 ....................................................................................................................................... 12 D7412G Control Panel, 2 of 3 ....................................................................................................................................... 13 D7412G Control Panel, 3 of 3 ....................................................................................................................................... 14 Current Rating Charts ....................................................................................................................................................... 15 Current Rating Chart for Standby Battery Calculations .......................................................................................... 15 Current Rating Chart for D8125MUX ........................................................................................................................... 16 Standby Battery .................................................................................................................................................................. 17 Requirements ....................................................................................................................................................................... 17 Household Burglary and Commercial Burglary ........................................................................................................... 17 Bank Safe and Vault .......................................................................................................................................................... 17 Central Station or Local Fire Alarm ............................................................................................................................... 17 Remote Station or Auxiliary Fire Alarm ......................................................................................................................... 17 Household Fire Warning Equipment .............................................................................................................................. 17 Calculation for NFPA 72 Fire Alarm Applications ...................................................................................................... 17 Current Chart First ............................................................................................................................................................. 17 Central Station or Local Systems .................................................................................................................................. 17 Remote Station or Auxiliary Systems ............................................................................................................................ 18 Household Fire Warning Equipment .............................................................................................................................. 18 Figures Figure Figure Figure Figure Figure Figure 1: 2: 3: 4: 5: 6: D9412G System Wiring Diagram, 1 of 3 ................................................................................................................... 9 D9412G System Wiring Diagram, 2 of 3 ................................................................................................................. 10 D9412G System Wiring Diagram, 3 of 3 ................................................................................................................. 11 D7412G System Wiring Diagram, 1 of 3 ................................................................................................................. 12 D7412G System Wiring Diagram, 2 of 3 ................................................................................................................. 13 D7412G System Wiring Diagram, 3 of 3 ................................................................................................................. 14 Tables Table 1: UL System Chart ................................................................................................................................................................. 7 Table 2: Current Rating Chart for Standby Battery Calculations ......................................................................................... 15 Table 3: Current Rating Chart for Standby Battery Calculations ......................................................................................... 16 Table 4: Central Stations or Local Systems Ampere-Hour Calculation Formula .............................................................. 17 Table 5: Remote Station or Auxiliary Systems Ampere-Hour Calculation Formula .......................................................... 18 Table 6: Household Fire Ampere-Hour Calculation Formula ................................................................................................... 18 Bosch Security Systems | 9/03 | 43494E D9412G/D7412G | Approved Applications Compliance Guide | Table of Contents Notes: Bosch Security Systems | 9/03 | 43494E EN | 4 D9412G/D7412G | Approved Applications Compliance Guide | 1.0 Overview 1.0 Overview 1.1 Listings and Approvals 1.1.1 Fire UL Underwriters Laboratories lists the D9412G/D7412G Control Panels as Signal System Control Units for: Central Station, Local, Auxiliary, Remote Station, and Household Fire Warning. 1.3.2 Test bell at arming: UL Standard 365 requires a bell test at arming for bank safe and vault applications. Approved by the California State Fire Marshal for highrise and non-highrise. Burglary UL Underwriters Laboratories lists the D9412G/D7412G Control Panels for: Central Station, Local, Police Connect, Bank Safe and Vault, Mercantile Safe and Vault, and Grade A Household Systems. Department of Defense (DOD) The D9412G/D7412G have been granted approval for Department of Defense (DOD) installations in Sensitive Compartmented Information Facilities (SCIF). 1.2 Introduction The UL System Chart (Table 1) references components evaluated and listed by Underwriters Laboratories for compatibility with the control panel. These components meet the basic system requirements for the applicable standard. The System Wiring Diagrams, Issue A (Figures 1, 2, 3, 4, 5, and 6) show the relationship between the panel and the accessory components referred to in the System Chart. 1.3 Optional Compatible Equipment UL Listed components not requiring evaluation for electrical compatibility can be used in many applications when installed according to the manufacturer’s instructions. 1.3.1 Burglary Applications UL Listed burglary alarm sensors not requiring evaluation for electrical compatibility can be used in burglary applications. In some cases a UL Listed Bosch Security Systems interface module must be used in conjunction with the sensors. Consult the individual component specification and installation documents to determine suitability. Test Weekly: UL Standard 1023 requires a weekly test for residential burglary applications. Bosch Security Systems | 9/03 | 43494E Bank Safe and Vault Applications The UL Listed Model 5110 Bell and Model 4001-42 External Line Balancer (both made by Rothenbuhler) must be used for the bell and balanced line module in bank safe and vault applications. Modifications must be made to the Bosch Security Systems D8108A Enclosure to meet UL Standard 681. See the 9000/9000G Series Technical Service Note: UL Certificated Bank Safe and Vault Applications (P/N: 73-07302-000). CSFM 1.1.2 EN | 5 1.3.3 . Fire Applications UL Listed fire initiating devices not requiring electrical compatibility evaluation can be used in any application. For example: 4-wire smoke detectors, heat detectors, water flow switches, and manual pull stations are suitable fire initiating devices. Consult the individual component specification and installation documents to determine suitability. Two-wire smoke detectors only connect to the panel through the D125B Powered Loop Interface so that an earth ground will not cause an alarm. Two-wire detectors must be evaluated for electrical compatibility, and must be UL Listed for use with the panel. See the 9000/ 9000G Series Technical Service Note: Smoke Detector Compatiblity (P/N: 33284), or contact the detector manufacturer. Other initiating devices, including four-wire smoke detectors connect to the panel through the D129 Dual Class A Initiation Circuit Module, the D125B Powered Loop Interface, D8127 or D9127 POPITs, or on-board points. When using 4-wire smoke detectors, install a suitable power supervision unit according to the manufacturer’s instructions. Use the D130 Relay Module, D8129 OctoRelay, or Terminal 8, Switched Aux Power to provide reset capability. See the Off-Board Relays section of the D9412G/D7412G Operation and Installation Guide (P/N: 43488). For battery calculations, refer to Section 4.1 Current Rating Chart for Standby Battery Calculations and Section 5.0 Standby Battery. Test weekly: Bosch Security Systems recommends a Fire Test be performed weekly. The AC power is automatically tested as is the battery per UL 864. D9412G/D7412G | Approved Applications Compliance Guide | 1.0 Overview 1.3.4 Enclosures Bosch Security Systems offers three optional enclosures for the control panel. • The D8103 Enclosure is suitable for residential fire and/or burglary installations and commercial burglary applications not requiring attack resistance or approval by Factory Mutual or NYC-MEA. (See Table 1 for acceptable applications.) • The D8108A Enclosure is attack resistant. Intended primarily for UL commercial burglar alarm and mercantile safe and vault applications requiring a local bell, the D8108A can be used in any burglar or fire alarm application where the D8109 enclosure is suitable. The D8108A, with some modification, can be used for bank safe and vault applications. See the 9000/9000G Series Technical Service Note: UL Certificated Bank Safe and Vault Applications (P/N: 73-07302-000). UL lists the D8108A for all commercial fire alarm applications. The D8108A is approved by Factory Mutual, California State Fire Marshal, and the New York City Materials and Equipment Acceptance System. • The D8109 Red Fire Enclosure is normally used for commercial fire alarm applications. UL lists the D8109 for all commercial fire alarm applications. The D8109 is approved by the California State Fire Marshal, NYC-MEA and FM. Note: All references to NFPA and related requirements are based upon compliance with the NFPA 72, National Fire Alarm Code. Since installation specifications are nearly always based upon a specific edition of a standard which has been legally adopted by the Authority Having Jurisdiction (AHJ), consult with the appropriate AHJ for confirmation. Bosch Security Systems | 9/03 | 43494E EN | 6 D9412G/D7412G | Approved Applications Compliance Guide | 2.0 System Chart 2.0 EN | 7 System Chart D8109 Enclosure D125B Class B, Style A Powered Loop Interface No Calculate current draw to determine if second battery is required. Opt. D129 Class A, Style D Initiating Module # # # # Opt. Opt. Opt. D126/D1218 Battery 1+ 1+ 1+ 1+ 1+ 1+ D127 Reversing Relay Opt. No Opt. Opt. Opt. Opt. D928 Dual Phone Line Module Opt. Opt. Opt. Opt. Opt. Opt. D161 Telephone Cord Required to connect panel to RJ31X TelCo. Block 24 + 5 mins alarm 24 + 5 mins alarm 24 + 5 mins alarm 24 + 5 mins alarm 24 + 5 mins alarm 24 + 5 mins alarm No No No No No No No No Choose one. Req. Req. Central Station Fire/ Burglary Combined 24 + 5 mins alarm Choose one. No Calculate current draw to determine if second battery is required. # - D125 and D129 required to connect fire alarm initiating devices to zones 1-8. D125 provides two powered loops for connecting listed 2-wire smoke detectors. D129 provides two non-powered Class A initiating circuits. 2+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ No Opt. No No Opt. Opt. No No Required for communication on two phone lines and/or CPU watchdog function. Required to connect panel to RJ31X TelCo. Block * Opt. Smoke Detector Base Opt. Opt. 1++ 1++ Opt. Opt. Opt. Required for indicating circuits. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. 1+ 1+ Opt. Opt. Optional, only connect to zones 1 to 8. D268/D269H Independent Zone Control Indicating Device 60 + 5 mins alarm 2 Req. D185 Auxiliary Interface Kit D192A/D192C/D192G Class B, Style W Bell Circuit Supervision Electrically Actuated Transmitter No Central Station Fire No Req. Local and Central Station Fire/ Burglary (Grade C) No Req. Local and Central Station Fire Combined 4 Local Fire Local Burglary 4 Local Fire/Burglary Combined Police Connected Burglary 4 Choose one. D101 lock required for enclosure. D8108A Enclosure D122 and D122L Dual Battery Harness 24 + 4 mins alarm Remote Station or Auxilliary Fire D8103 Enclosure 24 + 4 mins alarm Central Station Burglary (Grade C) 4 Household Fire/ Burglary Combined Minimum Hours of Standby Battery Household Fire Household Burglary Table 1: UL System Chart 1+ 1+ 1+ Opt. ** ** 1+ 1+ 1+,** Optional, may be required by job specifications and/or Authority Having Jurisdiction. D461 Pull Station 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ 1+ Opt. D1256 Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D1257 Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. D1255/D1260 Command Center D1640 Transformer D8004 Transformer Enclosure Required for all applications. Opt. Opt. Opt. Opt. Opt. Opt. Required Optional, contact TelCo. for availability of derived channel service. D8122 Derived Channel S.T.U. D8125 Class B, Style 3.5 POPEX Module Required for D8127T/U and D9127T/U POPITs. D8125MUX Required for MUX devices. Refer to section 4.2. D8127T/U & D9127T/U Class B, Style A POPIT Modules Opt. Opt. Opt. Opt. D8128D OctoPOPIT Opt. No Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Optional, for remote annunciation of system functions. D8129 OctoRelay D8130 Release Module Optional D8132 Battery Charger See Current Rating Chart and Standby Battery Requirements to determine if system requires a D8132 Module for increased battery standby. Optional, use with parallel printer to print events from panel log locally. D9131A Parallel Printer Interface D9210B Access Control Interface No No No Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. Opt. No No = Not acceptable for this application. Req. = Required for this application. Opt. = Optional for this application. # - D125B and D129 required to connect fire alarm initiating devices to zones 1-8. D125B provides two powered loops for connecting listed 2-wire smoke detectors. D129 provides two nonpowered Class A initiating circuits. 1+ = One or more required for this application. Consult the appropriate standard. 2+ = Two or more required for this application. Consult the appropriate standard. 1++ = At least one detector required. You can substitute other 2-wire detectors listed for use with the D125. You could also use the D262 with the D270 4-wire base and a listed power supervision relay. * = Auxiliary requires the D184 Auxiliary Local Energy Interface Kit. ** = Listed bell (siren) housing required for burglary alarm bell or siren. [Empty Box] = Not used for this application. Bosch Security Systems | 9/03 | 43494E D9412G/D7412G | Approved Applications Compliance Guide | 2.0 System Chart Notes: Bosch Security Systems | 9/03 | 43494E EN | 8 D9412G/D7412G | Approved Applications Compliance Guide | 3.0 System Wiring Diagrams 3.0 System Wiring Diagrams, Issue A 3.1 D9412G Control Panel, 1 of 3 EN | 9 Figure 1: D9412G System Wiring Diagram, 1 of 3 1 D113 CHGRBAT 2- - + D126/ D1218 - BAT 2+ VAUX+ BAT 1- SUPV BAT 1+ CHGR+ 2 3 6 4 5 + D126/ D1218 43489G 7 LEDs Off When Normal - - + D1640 16.5 V, 40 VA 60 Hzr + Charging Status Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter 1 2 D8132 3 11 4 5 D126 Battery 12 V, 7 Ah/ D1218 12 V, 17.2 Ah or 18.0 Ah D126 Battery 12 V, 7 Ah/ D1218 12 V, 17.2 Ah or 18.0 Ah Reference D9000/D9000G Series Technogram (P/N:33284___) For Compatible Smoke Detectors 10 8 9 Reference D9412G/D7412G Approved Application Compliance Guide (P/N:43494___) For System Wiring Diagram, Issue A 10.2 VDC - Battery Load Shed D126/ D1218 D126/ D1218 YEL RED D192A/C/G 12 AUX PWR ALARM TRIG COM CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment CAUTION: See D9412G/D7412G Operation and Installation Guide (P/N:43488) + AUX POWER For Power Requirements Relating to Terminals 6 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY 6 RELAY A 7 RELAY B 8 RELAY C POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation Guide (P/N:43488___). All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX WARNING! This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. 10 + - 10 10 C900 13 31 GREEN DATA BUS B 30 BLACK N.F.P.A. Style 3.5 Signaling Line Circuits Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 GND START 11 12 13 14 15 16 17 18 19 20 21 COMMON 29 ZONEX OUT 1 28 ZONEX IN 1 27 ZONEX OUT 2 26 ZONEX IN 2 25 ZONEX POWER + 24 ZONEX COMMON LOOP START GROUND START PHONE RED Requires Relay LED Model D136 in ON WHEN Ground COMMUNICATING OFF WHEN IDLE Start Socket 14 7 Point 1 Point 2 22 32 DATA BUS A VOLTAGE RANGES Open 3.7 - 5.0 VDC Normal 2.0 - 3.0 VDC Short 0.0 - 1.3 VDC PHONE MONITOR SELECT 10 POWER + YELLOW System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits the panel has been approved for are A, M, W, SS. COMMON EARTH GROUND GROUND FAULT DETECT Enabled Disabled D928 RED D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. SUPV IN 9 Battery: Replace Every 3 to 5 years with Model D126, 12 V 7 Amp Hr Lead Acid Battery Multi-Battery Installation Requires Model D122 Dual Battery Harness. Improper Installation Can Be a Fire Hazard. ALARM CKT 10 7 Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTIONS Point 8 GND FAULT Detect D E I N S A A B B L L E E 23 PROG CONN GRN 10 RJ31X 15 RJ31X Note: All external connections except Terminal 5 (battery positive) are inherently power limited. Bosch Security Systems | 9/03 | 43494E 16 1 - If required by local AHJ, connect D113 Battery Lead Supervision Module. 2 - To battery negative 3 - To AUX4 - To point input 5 - To battery positive 6 - D8004 Transformer Enclosure required for NFPA applications. 7 - Optional 8 - D122 Dual Battery Harness, as required 9 - See D113 for BATT SUPV 10 - Power limited, supervised 11 - Power limited 12 - To Relay A or Relay B 13 - Listed audible signaling devices rated at 10.2 to 13.8 VDC (do not use vibrating type horns). 14 - To RJ31X Jack 15 - EOL device (P/N: 15-03130-001) 16 - To Earth Ground D9412G/D7412G | Approved Applications Compliance Guide | 3.0 System Wiring Diagrams 3.2 EN | 10 D9412G Control Panel, 2 of 3 Figure 2: D9412G System Wiring Diagram, 2 of 3 43489G LEDs Off When Normal YEL Charging Status RED Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter Reference D9412G/D7412G Approved Application Compliance Guide (P/N:43494___) For System Wiring Diagram, Issue A 10.2 VDC - Battery Load Shed 1 2 4 BATTERY NEGATIVE ONLY RELAY A 7 RELAY B 8 RELAY C 9 COMMON PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX WARNING! 7 31 GREEN DATA BUS B 30 COMMON 29 ZONEX OUT 1 28 N.F.P.A. Style 3.5 Signaling Line Circuits This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. ZONEX IN 1 27 ZONEX OUT 2 26 ZONEX IN 2 25 ZONEX POWER + 24 D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 ZONEX COMMON Point 7 Point 8 PHONE MONITOR SELECT LOOP START GND START 11 12 13 14 15 16 17 18 19 20 21 22 32 DATA BUS A VOLTAGE RANGES Open 3.7 - 5.0 VDC Normal 2.0 - 3.0 VDC Short 0.0 - 1.3 VDC GROUND START PHONE RED Requires Relay LED Model D136 in ON WHEN Ground COMMUNICATING OFF WHEN IDLE Start Socket POWER + YELLOW BLACK Battery: Replace Every 3 to 5 years with Model D126, 12 V 7 Amp Hr Lead Acid Battery Multi-Battery Installation Requires Model D122 Dual Battery Harness. Improper Installation Can Be a Fire Hazard. EARTH GROUND D130 RED System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits the panel has been approved for are A, M, W, SS. GROUND FAULT DETECT Enabled Disabled - + For Power Requirements Relating to Terminals 6 Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY 6 PERIPHERAL DEVICE CONNECTIONS POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation Guide (P/N:43488___). All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. CAUTION: See D9412G/D7412G Operation and Installation Guide (P/N:43488) + AUX POWER 10 1 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment 3 5 Reset Pin Disable All Except Battery Charging And Programming Reference D9000/D9000G Series Technogram (P/N:33284___) For Compatible Smoke Detectors Point 8 GND FAULT Detect D E I N S A A B B L L E E 23 PROG CONN GRN D105BL 4 D105F 3 D125B Sw. Aux Pwr Zone B Zone A Pnl Common Pnl Common 1 2 D129 3 4 Loop B- 5 6 Loop A- 7 5 Loop BLoop BLoop B+ 8 9 Earth Ground 10 Loop A+ Note: All external connections except Terminal 5 (battery positive) are inherently power limited. 1 2 3 4 Aux Power 5 6 Earth Ground 7 Zone B 2 Loop B+ Bosch Security Systems | 9/03 | 43494E Loop B+ Common 8 Zone A 9 Loop A+ 10 Loop A- 11 Loop A- 12 Loop A+ 13 1 - (Optional): For 24 V applications, use a UL Listed 24 VDC Power Supply with a D130 Relay Module. Please refer to the D130 Operation and Installation Guide (P/N: 74-06262-000) for correct wiring requirements. 2 - To UL Listed 2-wire smoke detectors. Refer to the 9000/9000G Series Technical Service Note: Smoke Detector Compatibility (P/N: 33284) for a listing of compatible 2-wire smoke detectors. 3 - D105F EOLR: Suitable for non-powered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. 4 - D105BL EOLR: For typical burglar alarm applications. 5 - D129 provides optional Waterflow Retard feature. Not suitable for 2-wire smoke detectors. (Note: Use Zero Retard except for waterflow devices.) D9412G/D7412G | Approved Applications Compliance Guide | 3.0 System Wiring Diagrams 3.3 EN | 11 D9412G Control Panel, 3 of 3 Figure 3: D9412G System Wiring Diagram, 3 of 3 43489G LEDs Off When Normal D1255 YEL Charging Status RED Low Battery - 12.1 VDC D1257 D1256 1 D1260 Digital Alarm Communicator Transmitter Reference D9412G/D7412G Approved Application Compliance Guide (P/N:43494___) For System Wiring Diagram, Issue A 10.2 VDC - Battery Load Shed 1 2 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment CAUTION: See D9412G/D7412G Operation and Installation Guide (P/N:43488) 3 + AUX POWER 4 BATTERY NEGATIVE ONLY 5 Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY 6 RELAY A 7 RELAY B 8 RELAY C 9 COMMON 10 Reference D9000/D9000G Series Technogram (P/N:33284___) For Compatible Smoke Detectors POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation Guide (P/N:43488___). All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. For Power Requirements Relating to Terminals 6 PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX WARNING! 7 Battery: Replace Every 3 to 5 years with Model D126, 12 V 7 Amp Hr Lead Acid Battery Multi-Battery Installation Requires Model D122 Dual Battery Harness. Improper Installation Can Be a Fire Hazard. This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 LOOP START GND START GROUND START R ED PHONE Requires Relay LED Model D136 in ON WHEN Ground COMMUNICATING OFF WHEN IDLE Start Socket 7 - 32 DATA BUS A 31 GREEN DATA BUS B 30 COMMON 29 ZONEX OUT 1 28 ZONEX IN 1 27 BLACK N.F.P.A. Style 3.5 Signaling Line Circuits 11 12 13 14 D8125 + 15 16 17 18 19 20 21 22 3 3 3 3 D9210B 3 1 D9131A 2 3 ZONEX OUT 2 26 3 VOLTAGE RANGES Open 3.7 - 5.0 VDC Normal 2.0 - 3.0 VDC Short 0.0 - 1.3 VDC PHONE MONITOR SELECT + POWER + YELLOW RED ZONEX IN 2 25 ZONEX POWER + 24 ZONEX COMMON 23 D9412G Control / Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. EARTH GROUND 5 PERIPHERAL DEVICE CONNECTIONS System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits the panel has been approved for are A, M, W, SS. GROUND FAULT DETECT Enabled Disabled D8125 Reset Pin Disable All Except Battery Charging And Programming Point 8 GND FAULT Detect D E I N S A A B B L L E E 3 3 4 PROG CONN D9133TTL-E GRN D8128D 8 D8128D 9 D8129 10 D8129 11 6 - 7 Note: All external connections except Terminal 5 (battery positive) are inherently power limited. Bosch Security Systems | 9/03 | 43494E 1 2 3 4 5 6 7 - Up to 8 supervised Up to 3 supervised Power limited, supervised Power limited POPEX #1 POPEX #2 Up to 119 D9127U/T POPITs or up to 63 D8127U/T POPITs. 8 - Zx 1: 15 D8128Ds 9 - Zx 2: 15 D8128Ds 10 - Zx 1: Up to 8 maximum 11 - Zx 2: Up to 8 maximum D9412G/D7412G | Approved Applications Compliance Guide | 3.0 System Wiring Diagrams 3.4 EN | 12 D7412G Control Panel, 1 of 3 Figure 4: D7412G System Wiring Diagram, 1 of 3 1 D113 CHGRBAT 2- - + D126/ D1218 - BAT 2+ VAUX+ BAT 1- SUPV BAT 1+ CHGR+ 2 6 3 4 5 + 46729G D126/ D1218 7 - - + LEDs Off When Normal D1640 16.5 V, 40 VA 60 Hzr + YEL Charging Status RED Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter Reference D9412G/D7412G Approved Applications Compliance Guide (P/N:43494___) For System Wiring Diagram, Issue A Reference D9000/D9000G Series Technogram (P/N:33284___) For Compatible Smoke Detectors 10.2 VDC - Battery Load Shed D126/ D1218 8 9 10 D126/ D1218 CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment CAUTION: See D9412G/D7412G Operation and Installation Guide (P/N:43488) + AUX POWER D8132 For Power Requirements Relating to Terminals 6 11 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY D192A/C/G D126 Battery 12 V, 7 Ah/ D1218 12 V, 17.2 Ah or 18.0 Ah D126 Battery 12 V, 7 Ah/ D1218 12 V, 17.2 Ah or 18.0 Ah RELAY A 12 AUX PWR RELAY B ALARM TRIG RELAY C COM SUPV IN POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation Guide (P/N:43488___). All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX Battery: Replace Every 3 to 5 years with Model D126, 12 V 7 Amp Hr Lead Acid Battery Multi-Battery Installation Requires Model D122 Dual Battery Harness. Improper Installation Can Be a Fire Hazard. This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. - 10 GROUND FAULT DETECT Enabled Disabled GROUND START PHONE RED Requires Relay LED Model D136 in ON WHEN Ground COM MUNICATING Start Socket OFF WHEN IDL E 14 10 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 LOOP START GND START D928 10 DATA BUS A GREEN DATA BUS B BLACK COMMON N.F.P.A. Style 3.5 Signaling Line Circuits ZONEX OUT 1 ZONEX IN 1 VOLTAGE RANGES Open 3.7 - 5.0 VDC Normal 2.0 - 3.0 VDC Short 0.0 - 1.3 VDC Point 1 Point 2 GROUND START 10 POWER + YELLOW System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits the panel has been approved for are A, M, W, SS. EARTH GROUND + RED D7412G Control/Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. COMMON ALARM CKT 10 7 WARNING! Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTIONS 11 12 13 14 15 16 17 18 19 20 21 22 Point 8 GND FAULT Detect D E I N S A A B B L L E E PROG CONN GRN 7 RJ31X C900 13 15 RJ31X Note: All external connections except Terminal 5 (battery positive) are inherently power limited. Bosch Security Systems | 9/03 | 43494E 16 1 - If required by local AHJ, connect D113 Battery Lead Supervision Module. 2 - To battery negative 3 - To AUX4 - To point input 5 - To battery positive 6 - D8004 Transformer Enclosure required for NFPA applications. 7 - Optional 8 - D122 Dual Battery Harness, as required 9 - See D113 for BATT SUPV 10 - Power limited, supervised 11 - Power limited 12 - To Relay A or Relay B 13 - Listed audible signaling devices rated at 10.2 to 13.8 VDC (do not use vibrating type horns). 14 - To RJ31X Jack 15 - EOL device (P/N: 15-03130-001) 16 - To Earth Ground D9412G/D7412G | Approved Applications Compliance Guide | 3.0 System Wiring Diagrams 3.5 EN | 13 D7412G Control Panel, 2 of 3 Figure 5: D7412G System Wiring Diagram, 2 of 3 46729G LEDs Off When Normal YEL Charging Status RED Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter Reference D9412G/D7412G Approved Applications Compliance Guide (P/N:43494___) For System Wiring Diagram, Issue A CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment For Power Requirements Relating to Terminals 6 PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX DATA BUS A GREEN DATA BUS B BLACK COMMON N.F.P.A. Style 3.5 Signaling Line Circuits ZONEX OUT 1 ZONEX IN 1 System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits the panel has been approved for are A, M, W, SS. VOLTAGE RANGES Open 3.7 - 5.0 VDC Normal 2.0 - 3.0 VDC Short 0.0 - 1.3 VDC GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 GROUND START LOOP START GND START GROUND START PHONE RED Requires Relay LED Model D136 in ON WHEN Ground COMMUNICATING Start Socket OFF WHEN IDLE D130 POWER + YELLOW D7412G Control/Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. EARTH GROUND - + 7 This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. COMMON 1 RED Battery: Replace Every 3 to 5 years with Model D126, 12 V 7 Amp Hr Lead Acid Battery Multi-Battery Installation Requires Model D122 Dual Battery Harness. Improper Installation Can Be a Fire Hazard. Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY C POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation Guide (P/N:43488___). All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. WARNING! BATTERY NEGATIVE ONLY RELAY B PERIPHERAL DEVICE CONNECTIONS CAUTION: See D9412G/D7412G Operation and Installation Guide (P/N:43488) + AUX POWER RELAY A Reset Pin Disable All Except Battery Charging And Programming Reference D9000/D9000G Series Technogram (P/N:33284___) For Compatible Smoke Detectors 10.2 VDC - Battery Load Shed 11 12 13 14 15 16 17 18 19 20 21 22 Point 8 GND FAULT Detect D E I N S A A B B L L E E PROG CONN GRN D105BL 4 D105F 3 D125B Sw. Aux Pwr Zone B Zone A Pnl Common Pnl Common Loop B- 1 2 5 Loop A- 7 8 9 Loop B+ Loop BLoop B- 5 6 Loop B+ Loop A+ D129 3 4 Loop B+ Zone B 2 Earth Ground 10 Aux Power 1 2 3 4 5 6 Earth Ground 7 Common 8 9 Zone A Loop A+ 10 Loop A- 11 Loop A- 12 Loop A+ 13 Note: All external connections except Terminal 5 (battery positive) are inherently power limited. Bosch Security Systems | 9/03 | 43494E 1 - (Optional): For 24 V applications, use a UL Listed 24 VDC Power Supply with a D130 Relay Module. Please refer to the D130 Operation and Installation Guide (P/N: 74-06262-000) for correct wiring requirements. 2 - To UL Listed 2-wire smoke detectors. Refer to the 9000/9000G Series Technical Service Note: Smoke Detector Compatibility (P/N: 33284) for a listing of compatible 2-wire smoke detectors. 3 - D105F EOLR: Suitable for non-powered initiating and supervisory devices such as pull stations, heat sensors, and valve tampers. 4 - D105BL EOLR: For typical burglar alarm applications. 5 - D129 provides optional Waterflow Retard feature. Not suitable for 2-wire smoke detectors. (Note: Use Zero Retard except for waterflow devices.) D9412G/D7412G | Approved Applications Compliance Guide | 3.0 System Wiring Diagrams 3.6 EN | 14 D7412G Control Panel, 3 of 3 Figure 6: D7412G System Wiring Diagram, 3 of 3 46729G D1255 LEDs Off When Normal YEL Charging Status RED Low Battery - 12.1 VDC Digital Alarm Communicator Transmitter Reference D9412G/D7412G Approved Applications Compliance Guide (P/N:43494___) For System Wiring Diagram, Issue A Reference D9000/D9000G Series Technogram (P/N:33284___) For Compatible Smoke Detectors 10.2 VDC - Battery Load Shed CLASS 2 TRANSFORMER 16.5 VAC 40 VA 60 Hz Model D1640 Internally Fused - Do Not short Requires Unswitched Outlet Do Not Share With Other Equipment CAUTION: See D9412G/D7412G Operation and Installation Guide (P/N:43488) + AUX POWER For Power Requirements Relating to Terminals 6 BATTERY NEGATIVE ONLY Maximum Charging Current 1.4 Amps. BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C POWER SUPPLY REQUIREMENTS The Power Supply Provides a Maximum of 1.4 Amps For The Control Panel and All Accessory Devices. For System Loading, See D9412G/D7412G Operation and Installation Guide (P/N:43488___). All External Connections Except Terminal 5 (Battery Positive) Are Inherently Power Limited. Requirements For Battery Standby Time May Reduce Allowable Output. PROGRAMMABLE ALARM OUTPUTS Terminals 7 & 8 Requires Optional Model D136 Relay In ALT ALARM & SW AUX WARNING! 7 This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code) for Local, Central Station, Remote Station and Household Fire Warning Systems and under the limits of the Local Authority Having Jurisdiction (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269) Printed information describing proper installation, operation, testing, maintenance, evacuation planning and repair service is to be provided with this equipment. Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTIONS RED POWER + 3 YELLOW DATA BUS A GREEN DATA BUS B BLACK COMMON 3 3 N.F.P.A. Style 3.5 Signaling Line Circuits ZONEX OUT 1 D9210B 3 ZONEX IN 1 1 D9131A 2 3 System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years. The types of initiating circuits the panel has been approved for are A, M, W, SS. VOLTAGE RANGES Open 3.7 - 5.0 VDC Normal 2.0 - 3.0 VDC Short 0.0 - 1.3 VDC EARTH GROUND GROUND FAULT DETECT Enabled Disabled Point 1 Point 2 Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 GROUND START LOOP START GND START GROUND START PHONE RED Requires Relay LED Model D136 in ON WH EN Ground COMMU NIC ATIN G Start Socket OFF W H EN IDLE + D1260 D7412G Control/Communicator is UL Listed For Central Station, Local, Remote Station and Household Fire Alarm, and Central Station, Local, Police Station Connect and Household Burglar Alarm. COMMON D8125 D1257 3 Battery: Replace Every 3 to 5 years with Model D126, 12 V 7 Amp Hr Lead Acid Battery Multi-Battery Installation Requires Model D122 Dual Battery Harness. Improper Installation Can Be a Fire Hazard. D1256 1 11 12 13 14 15 16 17 18 19 20 21 22 Point 8 GND FAULT Detect D E I N S A A B B L L E E PROG CONN D9133TTL-E GRN D8128D 6 D8129 7 4 - 5 Note: All external connections except Terminal 5 (battery positive) are inherently power limited. Bosch Security Systems | 9/03 | 43494E 1 2 3 4 5 - Up to 8 supervised Up to 3 supervised Power limited, supervised POPEX #1 Up to 119 D9127U/T POPITs or up to 63 D8127U/T POPITs. 6 - Zx 1: 15 D8128Ds 7 - Zx 1: Up to 8 maximum D9412G/D7412G | Approved Applications Compliance Guide | 4.0 Current Rating Charts 4.0 Current Rating Charts 4.1 Current Rating Chart for Standby Battery Calculations EN | 15 Table 2: Current Rating Chart for Standby Battery Calculations Model Number Quantity Used A B C AC Power On Normal Current (mA) AC Power Off Minimum Current (mA) In Alarm Maximum Current (mA) Each Unit* Total 1 = 200 Each Unit Total 200 x 1 = 200 Each Unit Total D9412G/ D7412G ______ 200 x 500 x D125B ______ 20 x Quant. = ____ 19 x Quant. = ____ 123 x Quant. = ____ D127 ______ 13 x Quant. = ____ 12 x Quant. = ____ 45 x Quant. = ____ D129 ______ 25 x Quant. = ____ 25 x Quant. = ____ 25 x Quant. = ____ D185 ______ 120 x Quant. = ____ 120 x Quant. = ____ 350 x Quant. = ____ D192C ______ 15 x Quant. = ____ 26 x Quant. = ____ 50 x Quant. = ____ D192G ______ 15 x Quant. = ____ 26 x Quant. = ____ 50 x Quant. = ____ D1255 ______ 104 x Quant. = ____ 106 x Quant. = ____ 206 x Quant. = ____ D1256 ______ 104 x Quant. = ____ 106 x Quant. = ____ 206 x Quant. = ____ D1257 ______ 104 x Quant. = ____ 106 x Quant. = ____ 206 x Quant. = ____ D1260 ______ 95 x Quant. = ____ 97 x Quant. = ____ 200 x Quant. = ____ D720 ______ 55 x Quant. = ____ 20 x Quant. = ____ 75 x Quant. = ____ D8125 ______ 48 x Quant. = ____ 48 x Quant. = ____ 48 x Quant. = ____ D8125MUX* ______ D8127T/U ______ 3 x Quant. = ____ D8128D ______ 50 x Quant. = ____ 50 x Quant. = ____ D8129 ______ 20 x Quant. = ____ 20 x Quant. = ____ D8130 ______ 5 x Quant. = ____ 5 x Quant. = ____ 54 x Quant. = ____ D9127T/U ______ 0.5 x Quant. = ____ 0.5 x Quant. = ____ 0.8 x Quant. = ____ D9131A ______ 24 x Quant. = ____ 22 x Quant. = ____ 36 x Quant. = ____ D9210B ______ 100 x Quant. = ____ 100 x Quant. = ____ 120 x Quant. = ____ D928 ______ 14 x Quant. = ____ 14 x Quant. = ____ 45 x Quant. = ____ = ____ 3 x Quant. = ____ 1 = 500 = ____ 4 x Quant. = ____ 50 x Quant. = ____ 20x Quant. + 25 x # of relays = ____ Ratings of other devices in the system which are not shown above: ________ ______ ____ x Quant. = ____ ____ x Quant. = ____ ____ x Quant. = ____ ________ ______ ____ x Quant. = ____ ____ x Quant. = ____ ____ x Quant. = ____ ________ ______ ____ x Quant. = ____ ____ x Quant. = ____ ____ x Quant. = ____ ________ ______ ____ x Quant. = ____ ____ x Quant. = ____ ____ x Quant. = ____ ________ ______ ____ x Quant. = ____ ____ x Quant. = ____ ____ x Quant. = ____ Total A = _____ Total B = _____ Total C = _____ * = See Table 3 for determining maximum currents for the D8125MUX and its accessories. Bosch Security Systems | 9/03 | 43494E D9412G/D7412G | Approved Applications Compliance Guide | 4.0 Current Rating Charts 4.2 EN | 16 Current Rating Chart for D8125MUX Fill in the following chart to determine the maximum currents for the D8125MUX and its accessories. Transfer the total figures to Table 2. The maximum current draw for each MUX Bus is 75 mA. Table 3: Current Rating Chart for Standby Battery Calculations Accessory Model Qty. Used DS7432 DS7457 DS7460 DS7465 AC Power Off Maximum Current (mA) Each Unit Total System 10 x Qty. = 0.35 x Qty. = 1 x Qty. = 1 x Qty. = Ratings* of other devices on the MUX Buses which are not shown above: x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = Column A Total = * Refer to the device’s Installation Guide for current draw values. Bosch Security Systems | 9/03 | 43494E In Alarm Maximum Current (mA) Each Unit Total System 10 x Qty. = 0.35 x Qty. = 1 x Qty. = 1 x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = x Qty. = Column B Total = D9412G/D7412G | Approved Applications Compliance Guide | 5.0 Standby Battery 5.0 Standby Battery 5.1 Requirements 5.1.1 Household Burglary and Commercial Burglary Four hours of standby battery capacity required. 5.1.2 Bank Safe and Vault Seventy-two hours of standby battery capacity required (UL 365). Aux Power current for all devices, including control centers, must be limited to 300 mA or less to meet this requirement. 5.1.3 Central Station or Local Fire Alarm Twenty-four hours of standby plus 5 minutes of alarm operation required. Refer to the Ampere-Hour Calculation Formula in Table 4. 5.1.4 Remote Station or Auxiliary Fire Alarm Sixty hours of standby plus 5 minutes of alarm operation required. Refer to the Ampere-Hour Calculation Formula in Table 5. 5.1.5 Household Fire Warning Equipment Twenty-four hours of standby plus 4 minutes of alarm operation required. Refer to the Household Fire Ampere-Hour Calculation Formula in Table 6. EN | 17 5.2 Calculation for NFPA 72 Fire Alarm Applications 5.2.1 Current Chart First See the Current Rating Chart for Standby Battery Calculations for totals B and C used in the formulas below. When connecting two batteries, use either the D122 Dual Battery Wiring Harness or the D8132 Battery Charger Module. 5.2.2 Central Station or Local Systems Central Station or Local Systems require 24 hours of standby plus 5 minutes of alarm operation at the end of the 24 hour period. A single battery is sometimes adequate for Central Station Systems, but two batteries must be installed to meet the basic standby requirements for a Local System installation. Battery ampere hour (Ah) calculations must be used to verify compliance. The following formula includes the calculation for 5 minutes of alarm operation at the end of the 24 hour period, as well as a 10% contingency factor which allows for depletion of battery capacity with age. Table 4: Central Stations or Local Systems AmpereHour Calculation Formula Total B Hours Total C Hours Contingency Total Ah* (______ x 24) + (______ x .083) + 10% = ________ *Total Ah requirements must not exceed Ah capacity of batteries: two D126 Batteries = 14 Ah; one D1218 Battery = 17.2 or 18 Ah. Bosch Security Systems | 9/03 | 43494E D9412G/D7412G | Approved Applications Compliance Guide | 5.0 Standby Battery 5.2.3 Remote Station or Auxiliary Systems Remote Station or Auxiliary Systems require 60 hours of standby plus 5 minutes of alarm operation at the end of the 60 hour period. A D8132 Battery Charger Module with additional batteries installed in a separate D8109 or D8108A enclosure may be required in the system to meet the basic standby requirements for a Remote Station or Auxiliary System installation. Battery ampere hour (Ah) calculations must be used to verify compliance. The following formula includes the calculation for 5 minutes of alarm operation at the end of the 60 hour period, as well as a 10% contingency factor which allows for depletion of battery capacity with age. Table 5: Remote Station or Auxiliary Systems Ampere-Hour Calculation Formula Total B Hours Total C Hours Contingency Total Ah* (______ x 60) + (______ x .083) + 10% = ________ *Total Ah requirements must not exceed Ah capacity of batteries: two D126 Batteries = 14 Ah; one D1218 Battery = 17.2 or 18 Ah. Bosch Security Systems | 9/03 | 43494E 5.2.4 EN | 18 Household Fire Warning Equipment The Household Fire Warning Equipment Standard requires 24 hours of standby plus 4 minutes of alarm operation at the end of the 24 hour period. Battery ampere hour (Ah) calculations must be used to verify compliance. The following formula includes the calculation for 4 minutes of alarm operation at the end of the 24 hour period, as well as a 10% contingency factor which allows for depletion of battery capacity with age. Table 6: Household Fire Ampere-Hour Calculation Formula Total B Hours Total C Hours Contingency Total Ah* (______ x 24) + (______ x .067) + 10% = ________ *Total Ah requirements must not exceed Ah capacity of batteries: two D126 Batteries = 14 Ah; one D1218 Battery = 17.2 or 18 Ah. D9412G/D7412G | Approved Applications Compliance Guide | 5.0 Standby Battery Notes: Bosch Security Systems | 9/03 | 43494E EN | 19 Bosch Security Systems 130 Perinton Parkway Fairport, NY 14450-9199 USA www.boschsecurity.us Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2003 Bosch Security Systems 43494E