4514 - Columbia Lighting

   EMBED


Share

Transcript

4514 1' × 4' Recessed 4" Deep Cell Parabolic / 1 or 2-Lamp T5, T5HO, T8 PROJECT INFORMATION 4" Deep Louver Project Name Type Catalog No. Date magnetic or electronic ballasts. CEE NEMA Premium compliant. CONSTRUCTION Luminaire housing and end caps are die formed code gauge cold rolled steel. Anodized aluminum louver is secured in open or closed position by die formed steel hinges. Louver hinges from either side. A mechanical light trap prevents light leaks. Latches are finger-tip actuated, positive feed type, fabricated of spring steel, and completely concealed in the black reveal. FEATURES • Meets IES standard RP-1 glare control recommendations on most models • Ideal for today’s computer intensive electronic offices • Wide light distribution provides uniform illumination • 4" deep low iridescent anodized aluminum louver • UL listed 1598 • Surface mount available • Mechanical light trap prevents light leaks • Black reveal with full air handling capabilities • Damp label standard • NEC/CEC-compliant ballast disconnect standard ELECTRICAL Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6” through access location. NEC/ CEC-compliant ballast disconnect is standard. FINISH INSTALLATION Painted parts are treated with a five stage phosphate bonding process and finished with a high temperature baked white enamel. For post painted housing, suffix catalog number with PAF. Regressed slots are flat black. Choice of low iridescent silver louver finishes. For fast wiring connections without the necessity of opening fixture or wireway, a flex connector adapter plate is furnished with each luminaire. A plastic dust cover which eliminates construction dust and protects the lamps is provided as standard. AIR HANDLING Luminaire is available to fit most standard ceiling types as shown in specification sheet. For information on compatibility with specific ceilings, contact your Columbia representative. Luminaires for concealed suspension ceilings are furnished with necessary T-bar clips and/or wing hangers. CEILING COMPATIBILITY All supply/return and air extract functions are shown on the specification sheet and are available as a specified option. Specify air handling requirement by including function number as part of complete catalog number. Directional control vanes and/or extract dampers must be specified. Air extract slots are located out of sight in end caps. See air removal data on specification sheet. CERTIFICATION All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. BALLASTS Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, ORDERING INFORMATION 45 14 MODEL EXAMPLE 4514-132G-LD19-S-EU – NO. OF LAMPS 45 Recessed 4" Deep Cell Parabolic 1 One 2 Two 1 – CEILING TYPE G Grid F Overlap Flange M Modular Fit-in Trim SG Slot Grid SM Surface Mount (Static only) NO. CELLS CROSSWISE 1 One SIZE LAMP TYPE LOUVER FINISH 14 1' × 4' 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28 or 25 Watt 54 4', T5HO: 54 or 51 Watt LD Low Iridescent Semi-Specular (Std.) MA Matte Anodized Low Iridescent Semi-Specular Aluminum LS Low Iridescent Specular – NO. CELLS LENGTHWISE 6 Six 9 Nine E – – BALLAST OPTIONS E Electronic T8, Instant Start For a specific ballast vendor show as option. AIR FUNCTIONS S Static A Air Handling AV Air Handling w/Supply Vanes C Combination Supply/ Extract CV Combination Supply Vanes/Extract CD Combination Supply Extract Dampers GLR Fast Blow Fuse GMF Slow Blow Fuse EL Emergency Battery Pack F835 35K 78+ CRI T8 Lamps Installed FO835 35K 82 CRI T8 Lamps Installed F5835 35K 85 CRI T5 VOLTAGE Lamps Installed U 120V-277V C388 3-Wire Flex 347 347V C488 4-Wire Flex MS9 Master/Satellite w/9' Harness PAF Paint After Fabrication NYC NYC Compliant NYCU NYC Compliant, Union Label CVD Combination Supply Vanes Extract Dampers Page 1/2 Rev. 04/24/17 H Heat Extract HD Heat Extract w/Dampers PARABOLICS / 4514 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com 4514 1' × 4' Recessed 4" Deep Cell Parabolic / 1 or 2-Lamp T5, T5HO, T8 PHOTOMETRIC DATA Ballast Ballast Factor Lamp Lumens per Lamp Total Input Watts Shielding Angle Spacing Criterion 4514-132G-LD19E-PAF 45 Parabolic 1' × 4' 1-Lamp with 1 × 9 Cell SemiSpecular Louver B232I120 1.10 FO32 2900 35 0.0 22.5 45.0 67.5 90.0 N/A Along = 1.22 Across = 1.87 COEFFICIENTS OF UTILIZATION (%) 0 30 40 45 50 55 60 65 70 75 80 85 3356 3149 2955 2781 2367 919 105 62 44 29 22 0 3356 3297 3260 3271 3012 1826 218 89 55 44 22 0 3356 3462 3860 4326 4026 2331 957 205 55 44 22 0 3356 3575 5458 5252 3106 1911 1243 383 77 29 22 0 3356 3597 6009 5082 2766 1950 1349 357 55 29 22 0 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens % Lamp 712 1219 2066 2104 2104 % Fixt. 24.5 42.0 71.2 72.6 72.6 33.8 57.9 98.2 100.0 100.0 RCR Luminaire Test 10232 Test Date 6/10/03 AVG. LUMINANCE (Candela/Sq. M.) Average Luminance Angle LUMINAIRE DATA RC RW 1 2 3 4 5 6 7 8 9 10 70 81 75 70 65 60 55 51 48 45 42 80 50 30 78 76 71 67 64 59 57 52 52 46 47 41 43 37 39 33 36 30 33 28 10 74 64 55 48 42 37 33 29 26 24 70 79 74 68 63 58 54 50 47 44 41 70 50 30 77 75 69 66 62 58 56 51 51 46 46 41 42 37 38 33 35 30 33 27 10 73 63 54 47 42 37 33 29 26 24 50 74 67 60 55 49 45 41 38 35 32 50 30 72 64 57 50 45 40 36 33 30 27 INDOOR CANDELA PLOT 10 71 61 54 47 41 37 33 29 26 24 0 0 65 57 50 44 39 35 31 28 25 22 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Total Luminaire Efficiency 72.6% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 66 Yes-Maximum $3.64 based on 3000 hrs. and $0.08 per KWH Test A10229 Test Date 1/8/03 Ballast Ballast Factor Lamp Lumens per Lamp Total Input Watts Shielding Angle Spacing Criterion 4514-232G-LD19E-PAF 45 Parabolic 1' × 4' 2-Lamp with 1 × 9 Cell SemiSpecular Louver B232I120RH 0.95 FO32/741 2850 60 0.0 22.5 45.0 67.5 Average Luminance Angle Luminaire AVG. LUMINANCE (Candela/Sq. M.) N/A Along = 1.21 Across = 1.57 0 30 40 45 50 55 60 65 70 75 80 85 7659 7203 6845 6428 5376 2417 783 475 308 233 174 115 7659 7968 8031 7848 6821 3546 1015 523 338 233 202 115 90.0 7659 7659 7659 9169 10590 10914 9546 9434 9788 8353 8118 7848 6720 5829 5618 4352 4317 4641 2170 2913 3174 701 1224 1141 382 455 455 252 272 291 202 202 202 115 115 115 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens % Lamp % Fixt. 1322 2244 3503 3606 3606 23.2 39.4 61.5 63.3 63.3 COEFFICIENTS OF UTILIZATION (%) 36.6 62.2 97.2 100.0 100.0 DIMENSIONAL DATA RCR LUMINAIRE DATA RC RW 1 2 3 4 5 6 7 8 9 10 70 71 66 61 57 52 49 45 42 40 37 80 50 30 68 66 62 58 56 51 50 46 45 41 41 36 38 33 35 30 32 27 29 25 10 65 56 48 42 37 33 29 26 24 22 70 69 64 60 55 51 48 44 41 39 36 70 50 30 67 65 61 58 55 51 49 45 45 40 41 36 37 33 34 30 31 27 29 25 10 64 55 48 42 37 33 29 26 24 22 50 64 58 53 48 44 40 36 33 31 28 50 30 63 56 50 44 40 36 32 29 27 24 INDOOR CANDELA PLOT 10 62 54 47 41 36 32 29 26 24 22 0 0 57 50 44 39 35 31 28 25 22 20 75 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Total Luminaire Efficiency 63.3% Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 57 Yes-VDT Normal Use $4.21 based on 3000 hrs. and $0.08 per KWH CEILING COMPATIBILITY Type G 71/8" Type SG 83/8" Side 12" End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 1½" allowed. Type F Side End For 9/16" slot grid type ceilings. Louver will be level with the ceiling plane. Shoulder heights of tee or exact slot grid must be specified. Type M 48" 12" 7" Backpan K.O. Diagram A: 7⁄8" Dia. K.O. (1) C: 11/2" Dia. K.O. with 2.128" Dia. K.O. (1) 48" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 04/24/17 Side End For tile, plaster or plasterboard type ceilings. Overlapping extruded aluminum trim conceals edges of ceiling opening. Wing hanger suspension system included. For row mounting, row information is required. Side End For metal pan ceilings “Fit-in” style extruded trim aligns with modular tile joints. Fixture is supported from concealed suspension and includes all adjustable wing hangers. Flange kit rough in dimensions for single unit only: 121/8" × 481/8" PARABOLICS / 4514 © 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com