nVision Rack Mount Instructions for nVision Lab Reference The nVision Lab Reference can be mounted with rack mount ears to meet your permanent installation needs. The product enclosure is designed to fit in a multitude of rack installation forms in use worldwide. The rack panel has not been provided as part of this kit. Most rack mount panels are made from 0.090 in (2.3mm) or greater material thickness, but that is up to the user’s discretion. ALL DIMENSIONS ARE IN MILLIMETERS (INCHES) 294 (11.6) 280 (11.0) 150 (5.9) MAXIMUM WITH TWO PRESSURE MODULES 256 (10.1) UPPER PORT PRESSURE MODULE (PM) SHOWN CRYSTAL CPF SYSTEM: MEDIUM PRESSURE FEMALE (MPF) (1/4" MEDIUM PRESSURE TUBE SYSTEM WITH 7/16"-20 INTERNAL THREADS) MINI USB-B INTERFACE 143 (5.6) DISPLAY 120 (4.7) MAXIMUM KEYPAD 80 (3.2) 103 (4.1) 68 (2.7) 116 (4.6) SET SCREWS (4 PL) INCLUDED WITH KIT P/N 4302 POWER JACK ACCESS ON REAR PANEL M4 X 6 THREAD (4 PL) PANEL MOUNT FLANGES INCLUDED IN CRYSTAL ENGINEERING KIT P/N 4302 LOWER PORT PRESSURE MODULE (PM) SHOWN CRYSTAL CPF SYSTEM: MEDIUM PRESSURE FEMALE (MPF) (1/4" MEDIUM PRESSURE TUBE SYSTEM WITH 7/16"-20 INTERNAL THREADS) FRONT FEET TILT FEATURE FEET WITH RUBBER PADS (4 PL) PANEL MOUNT CUTOUT DETAIL 280 ±0.3 (11.0 ±0.01) 15 ±0.2 (0.6 ±0.01) 254 ±0.5 (10.0 ±0.020) 68 ±0.2 (2.7 ±0.01) 99 ±0.5 (3.9 ±0.02) R7 MAX- 4 PL (0.3) Ø 4.5 (0.18) THRU (4 PL) 12 ±0.3 (0.5 ±0.01) 1 Unclip the Rear Bezel from the Rear Panel Assembly of the nVision Lab Reference. 2 Place nVision Lab Reference into Rack Panel opening (from the front as shown in diagram) until the front bezel stops against the Rack Panel. 3 Remove the four (4) mounting screws on the Rear Panel Assembly of the nVision Lab Reference. 5 Slide Flange Bracket into exposed channel of Enclosure extrusion as shown on the drawing. Note that the Flange Bracket must face toward Rack Panel. Position completely against the rear side of the Rack Panel and install M4 set screws to secure. 7 Reinstall the Rear Panel Assembly using the four (4) mounting screws and replace the rear bezel. 8 The rack mounted nVision Lab Reference is now ready to be installed into the Rack. 6 After M4 screws are secure, install and tighten the set screws into the brackets. 4 Gently pull Rear Panel Assembly aside without disconnecting either the interconnect cable or BARO tube from the inside components. Note: BARO port and connected tube will only exist on units that have the BARO Module option. nVision Lab Reference Rear Bezel Set Screws (4 PL) M4 Screws (4 PL) not provided Mounting Screws (4 PL) Rack Mount Kit P/N 4302 Flange Bracket nVision Lab Reference Rear Panel Assembly Rack Panel (19 inch shown) not provided nVision Lab Reference © 2013 Crystal Engineering Corporation 4566. C 708 Fiero Lane, Suite 9, San Luis Obispo, California 93401-8701