Preview only show first 10 pages with watermark. For full document please download

460 Series Volt Amplifier Mpa-460 200-520 Vac 45

   EMBED


Share

Transcript

Servo Amplifiers ® S E R I E S 460 Series VOLT AMPLIFIER MPA-460 200-520 VAC 45-65Hz Amplifier Current Sizes Model Continuous Output Current Peak Output Current* PWM Frequency 1 Ø Line Current** 3 Ø Line Current** Weight 5 amps 9 amps 15 amps 25 amps 35 amps 50 amps 75 amps 100 amps 10 amps 18 amps 30 amps 50 amps 70 amps 100 amps 120 amps 165 amps 15KHz 15KHz 15KHz 12KHz 12KHz 10KHz 10KHz 10KHz 8 amps 10 amps 18 amps 30 amps 42 amps 60 amps N/A N/A 4 amps 7 amps 11 amps 18 amps 25 amps 35 amps 55 amps 70 amps 22.6 lbs.[10.2Kg] 23.2 lbs.[10.6Kg] 24.8 lbs.[11.3Kg] 28.4 lbs.[12.9Kg] 31.0 lbs.[14.1Kg] 38.6 lbs.[17.5Kg] 56.0 lbs.[25.4Kg] 68.4 lbs.[31.1Kg] MPA-05 MPA-09 MPA-15 MPA-25 MPA-35 MPA-50 MPA-75 MPA-100 *Peak Current ≥ 1 second. **Continuous Maximum Current Connection Diagram Wiring Diagram POWER POWER STATOR WIRING GAUGE GREEN SHLD SHLD RESOLVER INTERFACE 09 15 25 35 50 14 14 10 8 6 75 100 4 2 T Motor SHLD SHLD BLK/WHT GND TS RED R GND TS GND SIN COS GND COS GND REF REF LIMIT RESET HI-BUS MOTOR FEEDBACK AMPLIFIER SHORTS CONTINUOUS LIMIT RESET HI-BUS MOTOR FEEDBACK AMPLIFIER SHORTS CONTINUOUS DIAGNOSTIC INDICATORS Typical Controller MARK Channel A (+) Channel A (-) Channel B (+) Channel B (-) Marker (+) Marker (-) Encoder Gnd MARK ENCODER INTERFACE ENCODER ENCODER I/O INTERFACE I/O RESP SIG FLT V/T BAL LEAD -LIM +LIM RES L3 GND CUR -COM +COM L2 CUR VEL GND ADJUSTMENT POTENTIOMETERS AC POWER CUR L1 L3 GND +COM L2 AC POWER +AUX L1 I/O GND -AUX +AUX BAL -COM MOTOR THE RESOLVER CABLE IS 100% SHIELDED (FOIL & BRAID) WITH A DRAIN WIRE. THE CONDUCTORS AND DRAIN WIRE ARE 24 GAUGE. CURRENT CURRENT GND -AUX Feedback BLU/WHT BLUE YELLOW BLACK RED YEL/WHT RED/WHT GND SIN GND GND AC POWER INPUT 05 18 FEEDBACK S BLACK MOTOR T S MOTOR BLUE FEEDBACK R POWER TO MOTOR MPA-XXX-460 MIN. WIRE GAUGE THE STATOR WIRING IS 100% SHIELDED (FOIL & BRAID). CUR VEL RESP GND SIG Gnd Command (-) Command (+) Drive Fault FLT V/T LEAD -LIM +LIM RES Drive Enable RESET RESET MaxPlus® is a registered trademark of MTS Systems Corporation. ©2000 MTS Systems Corporation. C Servo Amplifiers ® S E R I E S Mechanical Footprints .31 in. (7.87 mm) .50 in. (12.70 mm) (RECOMMENDED) MPA-460 Amplifier Dimensions T MPA-05/09/15-460 MPA-25/35-460 MPA-50-460 FEEDBACK GND TS R A in.[mm] B in.[mm] C in.[mm] 6.50[165.10] 8.50[215.90] 8.50[215.90] 4.50[114.30] 6.50[165.10] 6.50[165.10] 0.53[13.46] 0.53[13.46] 2.30[58.42] Model SHLD SHLD S MOTOR POWER GND SIN 14.60 in. (370.84 mm) GND COS SIDE VIEW GND REF LIMIT RESET HI-BUS MOTOR FEEDBACK AMPLIFIER SHORTS CONTINUOUS 13.60 in. (345.44 mm) CURRENT MARK ENCODER I/O BAL +AUX L3 GND CUR -COM L2 +COM CUR VEL RESP GND SIG FLT V/T L1 AC POWER GND -AUX LEAD -LIM +LIM RES RESET 11.25 in. (285.75 mm) B C A Note: Dimensions are to be used for reference purposes only. MPA-75/100-460 15.20 in. (386.08 mm) 3.15 in. (80.01 mm) 5.50 in. (139.70 mm) 5.50 in. (139.70 mm) 11.63 in. (295.40 mm) .50 in. (12.70 mm) (RECOMMENDED) POWER S MOTOR T FEEDBACK SHLD SHLD R GND TS GND SIN GND COS GND REF 14.60 in. (370.84 mm) LIMIT RESET HI-BUS MOTOR FEEDBACK AMPLIFIER SHORTS CONTINUOUS SIDE VIEW 13.60 in. (345.44 mm) CURRENT MARK ENCODER I/O GND -AUX BAL +AUX L3 L2 AC POWER GND CUR -COM +COM CUR VEL RESP GND SIG L1 FLT V/T LEAD -LIM +LIM RES RESET .31 in. (7.87 mm) 1.64 in. (41.66 mm) Note: Dimensions are to be used for reference purposes only. MaxPlus® is a registered trademark of MTS Systems Corporation. ©2000 MTS Systems Corporation. C