T-700, T-720, and T-725 Readers Installation Sheet Description
The package should include the following contents: • • • •
The T-700, T-720, and T-725 Smart Card Readers support 13.56 MHz Mifare (ISO 14443, Type A) Classic 1k and 4k, Vicinity (ISO 15693), HID iClass, and FIPS 201 (PIV) [3] credential technologies. The readers are capable of reading encoded data from the secure sector of the Mifare credentials. The reader output is either Wiegand or RS-485 communication.
• • •
Electronic assembly Cover Mounting base T-700, T-720, and T-725 Readers Installation Sheet (this document) Hardware mounting kit Mounting hole template Cable (pigtail) assembly (models 720 and 725 only)
For secure credentials, the readers encrypt communication between a smartcard and the reader using either diversified or secured keys. The reader compares user information with the information stored on the card.
Verify contents Inspect the package and contents for visible damage. If any components are damaged or missing, do not use the unit; contact the supplier immediately. If you need to return the unit, you must ship it in the original box.
Credential default read settings The readers support the following credentials: Table 1: Supported credentials Name
Type
Size
RF Technology
Default
Output
Diversified GE keys
Mifare
1k, 4k
ISO 14443
ON
26 bit or 55 bit
OESM fixed keys
Mifare
1k, 4k
ISO 14443
OFF
26 bit or 55 bit
Diversified GE keys
My-D
10 kBits
ISO 15693
ON
26 bit or 55 bit
FIPS 201 / PIV[3]
US Government*
All
Type A / Type B
OFF
75 bit or 200 bit (GSA defined)
UID only
HID iClass**
2k
13.56 MHz
ON
55 bit
UID only
Vicinity (non My-D)**
All
ISO 15693
ON
55 bit
UID only
DESFire**
All
ISO 14443
ON
40 bit
* Pending certification and release. When enabled, ISO 14443 UID read is disabled. ** When in T-5xx emulation mode, enabled by the command card.
1 of 4
P/N 460975001C • ISS 18NOV10
Communication protocol The reader supports Open Supervised Device protocol (OSDP) for RS-485 communication. When using Wiegand communication, the output is in the format encoded on the cards. When using PIV, the Wiegand output can be configured to either 75-bit or 200-bit [3].
Installation All reader models can be mounted on a single-gang electrical box or directly on the wall. The T-700 requires an additional mounting plate that must be ordered separately when mounting on a single-gang box. The T-720/725 readers can also be mounted on a 2-gang electrical box.
Table 3: RS-485 address selection Address
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
00
0
0
0
0
0
01
0
0
0
0
1
02
0
0
0
1
0
03
0
0
0
1
1
04
0
0
1
0
0
05
0
0
1
0
1
•••
•••
•••
•••
•••
•••
30
1
1
1
1
0
31
1
1
1
1
1
0 = OFF, 1 = ON Figure 1: Mounting template
1. Find a suitable mounting location for the reader on the wall or doorframe. 2. If mounting directly on the wall, perform the following: T-700 reader: Drill the properly sized and spaced mounting holes according to the dimensions shown in Figure 1. Drill one 0.75 in. (1.9 cm) diameter hole for the reader cable. T-720/725 readers: Drill properly sized and spaced mounting holes according to the dimensions shown in Figure 1. Drill one 1.38 in. (3.5 cm) x 0.68 in. (1.7 cm) rectangular cutout for the reader cable. 3. Mount the base to the wall or doorframe using #6 (3.5 mm) screws or larger. 4. Wire the reader cable to the panel cable in accordance with procedures specified in “Wiring” on page 3. 5. Set the DIP switches to the appropriate setting for your configuration. See Table 2 and Table 3. 6. Secure the case and cover onto the base using the #6 security screw provided. See Figure 2 and Figure 3. Table 2: DIP switch settings Switch
Function
Setting
1
Termination for Y – Z
Default = OFF = No termination
2
Termination for A – B
Default = OFF = No termination
3
Half/full-duplex select
Default = OFF = full duplex
2 of 4
P/N 460975001C • ISS 18NOV10
Figure 2: T-700 reader installation
Wiring The T-700 reader is supplied with a fixed 12 conductor pigtail and the T-720 and T-725 are supplied with a pluggable 12 conductor pigtail. The voltage specifications for these readers is 10-16 VDC, although 12 VDC or greater is recommended for better performance and cable run distances. To wire the readers: 1. Use the cable connection table below to connect the pigtail to the panel cable. Match the pigtail colors to the correct panel cable signal wires. 2. Provide a DC power source of 10-16 VDC. 3. Verify the reader is properly grounded by connecting the reader drain wire to the panel. Refer to the panel installation manual for connection details.
Figure 3: T-72x reader installation
Table 4: Wiring connections Mode
P/N 460975001C • ISS 18NOV10
Color
Wiegand
RS485 HD (2-wire)
RS485 FD (4-wire)
Red
10 to 16 VDC
10 to 16 VDC
10 to 16 VDC
Black
Ground
Ground
Ground
Green
Data 0
Not used
Receive +
White
Data 1
Not used
Receive −
Orange
Green LED control
Green LED control
Green LED control
Brown
Red LED control
Red LED control
Red LED control
Yellow
Beeper control
Beeper control
Beeper control
Gray
Not used
Not used
Not used
Pink
Card present
Transmit/receive +
Transmit +
Tan
Tamper
Transmit/receive −
Transmit −
Blue
Not used
Not used
Not used
Purple
Not used
Not used
Not used
3 of 4
Configuration cards
Compatible electrical boxes
T-700 readers: North American single-gang box (with additional mounting plate – ordered separately) T-720/725 readers: North American single-gang box North American 2-gang box
Colors
Black, charcoal, and gray
Regulatory
ETL 294, UL 294, CE and FCC Part 15
The following predefined configurations cards are available from UTC Fire & Security to assist you in setting up the listed functions for your reader. Table 5: Predefined configuration cards (no customer input required)
Kit part #
Configuration card set
Function
521305001
Beeper off
Set beeper off
ISO standards
Reset configuration to default
Reset configuration to default
Mifare ISO 14443A Vicinity ISO 15693
GSA standard
FIPS 201 (PIV) [3]
LED green normal
Change LED colors
Reset configuration to default
Reset configuration to default
521306001
521309001
UL evaluation for UL listed installations:
Select 200-bit PIV format
Set PIV Wiegand format
[1] Model T-700, T-720, and T-725 read range:
Disable PIV
Disable PIV
Enable PIV
Enable PIV
[2] Operating environment: Temperature −25 to 120°F (−31 to 49°C) Humidity 0 to 85% RH, noncondensing
Reset configuration to default
Reset configuration to default
5xx emulation enable
Read 13.56 MHz UID(s)
Reset configuration to default
Reset configuration to default
Certification and compliance
Keypad configuration to 1 key, 8-bit complement
Sets keypad output to 1 key, 8-bit complement
Certification
Keypad configuration to 4-bit burst
Sets keypad output to 4bit burst
Specifications Voltage
10 to 16 VDC
Power supply
Linear DC recommended
Cable distance from reader to panel
200 ft. max. 22 AWG 300 ft. max. 20 AWG 500 ft. max. 18 AWG
Read range [1]
Model T-700, T-720, and T-725 • • •
Mifare up to 1 in. (2.54cm) Ultralight cards not supported Vicinity up to 2 in. (5.08cm)
Wiegand output
Mifare 5502 (55-bit) Vicinity 5502 (55-bit)
Tamper output
Open collector
Credential technologies
Mifare (Secure) Classic 1k and 4k My-d (Secure) 10k FIPS 201 (PIV) [3] ISO 14443 Level 2 (UID only) ISO 15693 (UID only for non My-d)
Operating environment [2] Temperature Humidity
4 of 4
Average: less than 105 mA at 12 VDC Peak: less than 260 mA at 12 VDC
Set PIV Wiegand format
521307001[3] Select 75-bit PIV format
521308001
Regulatory evaluation Power consumption
-31°F to +149°F [-35°C to +65°C] 0 to 93% RH, noncondensing at 90°F (32°C)
Mifare up to 1 in. (2.54cm) Ultralight cards not supported Vicinity up to 2 in. (5.08cm)
[3] FIPS/PIV mode not evaluated by UL
N413 European Union directives 2002/96/EC (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.
Contacting customer support You can reach customer support by phone from 8 a.m. to 8 p.m. EST, Monday through Friday. UTC Fire & Security United States: 1-888-437-3287 Asia: 852-2907-8108 Australia: 61-3-9239-1200 Canada: 800-267-6317 Europe: 32-2-725-11-20 Latin America: 305-593-4301 utcfireandsecurity.com © 2010 UTC Fire & Security. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are under license to UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065
P/N 460975001C • ISS 18NOV10