Preview only show first 10 pages with watermark. For full document please download

466-121_al-1291 Alliance Point Id Data Gathering Panel_20070730

   EMBED


Share

Transcript

GE Security Alliance Intrusion Detection Data Gathering Panels Overview Features The Point ID data gathering panel identifies the exact location of an alarm or trouble event, saving time for emergency personnel and service technicians. Point ID is a two-wire system with a dedicated, bidirectional communication bus. This means up to 50 percent fewer termination points on powered devices. • Up to 32 individually addressed Point ID devices The AL-1291 Point ID data gathering panel (DGP) combines data and power supply in one panel. • Communicates with sensors transmitting from up to 5,000 feet (1,500 m) away • Bus supports up to 15 Point ID device DGPs from the Alliance panel The panel provides connections to motion sensors, glassbreak detectors, and other devices that extend the capabilities of Alliance and allow easier installations, even in adverse conditions. Up to 15 data gathering panels (DGPs) may be incorporated into an Alliance system so that Point ID devices may be connected for motion sensing, glassbreak protection, and more. The Point ID DGP doesn’t need extensive cabling. It’s easy to install—perfect for retrofit or takeovers. In order to expand existing installations, simply connect a detector to the standard 2-wire Point ID cable bus. Devices can be connected to the bus in one single loop or in a multi-drop configuration. No bus termination is needed. The address setting for each Point ID device is directly linked to the control panel zone number for that device. AL-1291 Alliance Point ID Data Gathering Panel Data Sheet 466-121-ISSUE2 / 20070730 Not to be used for installation purposes. Page 1 of 2 Alliance 1291 basic system capacity GE Security Data sheet graphic allowance 25 picas (w) x 28 picas (h) (4.167 in. x 4.667 in.) System Block Diagram Americas T 503 885 5700 T 888-GE-SECURITY (437 3287) F 800 483 2495 System control panel Memory expansion module System Canada T 519 376 2430 F 519 376 7258 Control Panel (available for some panels) Embedded alarms Zone input expansion modules Relay output expansion modules Asia T 852 2907 8108 F 852 2142 5063 All control panels will manage 16 RAS devices, 15 DGP addresses, and 255 outputs, while the number of inputs varies per panel. RS-485 system data bus Australia T 61 3 9259 4700 F 61 3 9259 4799 Europe T 32 2 725 11 20 F 32 2 721 86 13 Latin America T 305 593 4301 F 305 267 4300 I/O expanders and sensors AL-1291 Point ID DGP Each can add up to 16 addressable I/O expanders and sensors (expandable to 32) to the system. [email protected] www.gesecurity.com Note: See the specifications of individual components for details. © 2007 General Electric Company All Rights Reserved Specifications System capacity Firmware Electrical Physical and environmental Regulatory Maximum 240 devices per Alliance main control panel Up to 32 Point ID modules per AL-1291 Distance from panel: Up to 5,000 ft. Tamper included Addressing through DIP switches Requires system firmware version AL-4xxx.04.05.10 or higher Power supplied from Alliance data bus or remote auxiliary power supply Input voltage: 9.9 to 13.2 VDC Operating current: 53 mA (no devices attached to bus) Operating temperature: 50 to 122°F (10 to 50°C) Relative humidity: 95% noncondensing Dimensions: 3.1 x 3.5 in. (80 x 90 mm) UL 294, UL 609, UL 365, UL 1610, UL 1635 FCC Part 15B Class B Ordering information AL-1291 AP750-ID 4140-ID SI-ID 5845-ID Point ID data gathering panel Point ID 50-ft. motion sensor Point ID 4-in/4-out device Point ID single input expansion module Point ID glassbreak sensor imagination at work Data Sheet 466-121-ISSUE2 / 20070730 Not to be used for installation purposes. Page 2 of 2