SONG CHUAN 305 Features ϭ DPDT ; 4PDT General Purpose Power Relay. ϭDC / AC Coil. ϭ10A 24VDC/250VAC ; UL, CSA/CUS Approvals. ϭWith position indicator and manual override. ϭOptional LED and protection diode. ϭComply with RoHS-Directive 2002/95/EC. German Technology Type List Terminal Contact Designation style form (provided with) 2C (DPDT) LED Quick terminal 4C (4PDT) Enclosure style Dust cover with Dust cover with manual lockable manual 305-2CC-D-1 305-2CC-DM-1 Diode & LED 305-2CC-D-4 305-2CC-DM-4 LED 305-4CC-D-1 305-4CC-DM-1 Diode & LED 305-4CC-D-4 305-4CC-DM-4 Ordering Information 305 1 - 4C C 2 3 - DM 4 1. 305 -- Basic series designation 2. 2C 4C -- Double pole double throw -- Four pole double throw 5 5. Blank 1 2 3 3. C CA -- Contact material AgNi -- Contact material AgNi + Au plating 4. D DM -- Dust cover with manual -- Dust cover with lockable manual Contact Rating 212 Rated load (resistive) 10A / 250VAC Max. switching current 20A Max. switching capacity 2000VA 4 5 -- Without special features -- Coil parallel with LED -- Co il parallel with diode, the positive poleϚ+ϛon #14 terminal -- Coil parallel with diode, the negative poleϚ-ϛon #14 terminal -- Coil parallel with diode & LED, the positive pole Ϛ+ϛon #14 terminal -- Coil parallel with diode & LED, the negative poleϚ-ϛon #14 terminal SONG CHUAN 305 Coil Rating (DC) Rated Rated current Coil resistance Max. continuous Pick up Drop out Power consumption voltage ̈́10 % at 23°C ̈́10 % at 23°C voltage voltage(Max) voltage(Min) at rated (V) (mA) (7) at 60°C at 23°C at 23°C voltage 12 83.9 143 24 41.7 576 48 21.3 2,250 110 % of 80% of 5% of 60 18.6 3,225 rated rated rated 110 9.1 12,100 voltage voltage voltage 125 8.8 14,200 220 5.0 44,230 approx. 1.0W Coil Rating (AC) Rated Coil resistance Max. continuous Pick up Drop out Power consumption voltage ̈́10 % at 23°C voltage voltage(Max) voltage(Min) at rated (V) (7) at 60°C at 23°C at 23°C voltage 12 46.5 24 177 48 762 110 % of 85% of 15% of 60 1,200 rated rated rated 115 4,570 voltage voltage voltage 120 4,570 220/230/240 19,040 approx. 0.98VA Specification Contact material AgNi alloy (1) Contact resistance Operate time (1) Release time (1) 10 ms Max. 10 ms Max. Insulation resistance Dielectric strength 100m7 Max. (1A(100mA for Au-plating contact)/6VDC by 4 pipes m7 meter) (1) 1,000 M7 Min. (DC 500V) (1) Between open contact : AC 1000V , 50/60Hz 1 min. Between contact and coil : AC 2500V , 50/60Hz 1 min. Between contact circuits : AC 2000V , 50/60Hz 1 min. Vibration resistance Operating extremes 30 ~ 100Hz , NC>2G,NO>10G Life expectancy Mechanical 20,000,000 operations (frequency 18,000 operations/hr) -40 ~ +60°C (no freezing) Operating ambient temperature Weight Approx. 33g NoteΚ(1) initial value Safety Approval Certified UL CSA / CUS File No. E74321 171397 Safety Approval Rating UL CSA / CUS 10A 24VDC / 250VAC 1/6HP 120VAC / 240VAC 10A 24VDC / 250VAC 213 SONG CHUAN 305 6 5.5 (0.217) 0.5 3.6 (0.020) (0.142) 4.2 (0.165) 4.4 6.35 (0.250) 6.35 (0.236) 37.4 (1.472) (1.709) 43.4 Outline Dimensions 4.1 (0.173) 4.4 (0.161) 4.4 (0.173) (0.173) (0.250) 27.5 2.4 (1.083) (0.094) 21 (0.827) Wiring Diagram BOTTOM VIEW 4C 2C Engineering Data Coil operating range AC Coil operating range DC 220 220 200 200 0A 180 Coil voltage(%) Coil voltage(%) 180 160 4Cx10A 140 2Cx10A 120 0A 160 140 120 With coil voltage 100% Without coil voltage 100 100 80 Without coil voltage 80 60 0 20 40 60 80 60 100 0 20 40 Ambient temperature(°C) 80 100 Switching capability DC Below limiting characteristic: service life of contacts 4 2 x 10 switching cycles (90 % operating) resistive load 20 5 10 2 1 0,5 0,2 Max.DC load breaking capacity 300 Resistive load 200 Switching voltage (V) 10 Switching current in A Service life of contact (x106) Electrical Service Life AC 90 % operating resistive load condustive load cosͫ= 0.4...0.7 5 2 1 0,5 100 four contact Two contact 50 40 One contact 30 20 0,1 0,05 0,2 10 2 5 100 2 5 1000 Switching capacity in VA 214 60 Ambient temperature(°C) ———— 2 5000 0,1 0 20 40 60 80 100 120 140 160 180 200 220 10 0.1 0.2 Switching voltage in V All specifications subject to change. Please contact Song Chuan for update. ———— 0.5 1 2 Switching current(A) 5 10