Transcript
O UTSIDE PLANT OUTSIDE
PLANT
Cables
Index
OUTSIDE PLANT CABLES: TELEPHONE/FIBER/COAXIAL
CONTENTS
• • • • • • • • • •
FILLED SOLID ALPETH CABLE FILLED FOAM SKIN ALPETH CABLE FILLED FOAM SKIN CACSP CABLE AIRCORE ALPETH CABLE DOUBLE JACKETED BURIED DISTRIBUTION WIRE FILLED ASP CABLE, FOAM SKIN INSULATION BURIED SERVICE WIRE DOUBLE JACKETED BURIED DISTRIBUTION WIRE BURIED SERVICE WIRE AERIAL SERVICE WIRE
1 3 5 7 9 11 13 15 17 19
• • • •
ARMORED MACROTEL OPTICAL CABLE DRY DIELECTRIC MACROTEL OPTICAL CABLE DIELECTRIC DJ MACROTEL OPTICAL CABLE DRY LIGHT ARMORED MACROTEL OPTICAL CABLE
20 21 22 23
• • • •
1/2” (12.7mm) RF COAXIAL CABLE 7/8” (22.2mm) RF COAXIAL CABLE 1-1/4” (31.75mm) RF COAXIAL CABLE 1-5/8” (41.275mm) RF COAXIAL CABLE
24 25 26 27
• TRUNK AND DISTRIBUTION CABLE
Condumex Wire and Cable
28
2590 114th Street, #200 - Grand Prairie, TX 75050 (800) 925-9473
11-03
1
I. Exchange Cables
Filled Solid ALPETH Cable REA/RUS PE-39 62.39.01
CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 and 19 AWG. INSULATION: Solid, high-density polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and crosstalk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80°C) compound. Then covered with a non-hygroscopic tape with an overlap. A filling compound is applied over the wrap.
All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into 12 and 13 pair sub-units. SHIELD: Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
Outside plant telephony or underground installation.
Meets REA/RUS PE-39 ANSI/ICEA S-84-608-1994. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: none
ISO-9001 Quality Assurance System
Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
1
26 AWG Product Code
Number of Pairs
In
Nominal OD mm
Approximate Cable Weight Lbs/kft
Kg/km
Standard Length Ft
m
625152 625153 625154 625156 625157 625158 625159 625160 625161 625162
25 50 100 200 300 400 600 900 1200 1800
0.61 0.75 0.95 1.22 1.44 1.61 1.89 2.26 2.70 3.21
15.5 19.0 24.0 31.0 36.5 41.0 48.0 57.5 68.5 81.5
159 257 434 782 1114 1428 2927 2944 4003 5819
237 384 647 1166 1661 2129 3023 4390 5970 8678
5000 5000 3000 3000 3000 3000 1500 1000 1000 650
1525 1525 915 915 915 915 460 305 205 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626168 626169 626170 626171 626172 626173 626174 626196 626177 626178 626179 626180 626181
6 12 18 25 50 75 100 200 300 400 600 900 1200
0.47 0.59 0.67 0.75 0.89 1.04 1.16 1.48 1.71 1.95 2.35 2.81 3.23
12.0 15.0 17.0 19.0 22.5 26.5 29.5 37.5 43.5 69.5 60.0 71.5 82.0
107 157 198 241 402 563 701 1261 1794 2260 3282 4727 5687
160 235 295 360 600 840 1045 1880 2675 3370 4895 7050 8481
5000 5000 5000 5000 5000 5000 3000 3000 3000 1650 1650 1000 650
1525 1525 1525 1525 1525 1525 915 915 915 500 500 305 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626188 626189 626190 626191 626192 626193 626194 626196 626197 626198 626199
6 12 18 25 50 75 100 200 300 400 600
0.57 0.67 0.75 0.85 1.04 1.22 1.38 1.75 2.13 2.40 2.87
14.5 17.0 19.0 21.5 26.5 31.0 35.0 44.5 54.0 61.0 73.0
134 201 228 342 563 798 1019 1797 2625 3997 4976
200 300 340 510 840 1190 1520 2680 3915 5960 7420
5000 5000 5000 5000 3000 3000 3000 1650 1650 1000 1000
1525 1525 1525 1525 1525 915 915 500 500 305 305
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626205 626206 626207 626208 626209 626210 626211 626213 626214
6 12 18 25 50 75 100 200 300
0.71 0.85 0.96 1.06 1.42 1.66 1.83 2.48 2.95
18.0 21.5 24.5 27.0 36.0 42.0 46.5 63.0 75.0
211 349 466 590 1059 1485 1921 3557 5197
315 520 695 880 1580 2215 2865 5305 7750
5000 5000 5000 5000 3000 3000 3000 1000 650
1525 1525 1525 1525 915 915 915 305 200
24 AWG Nominal OD
Approximate Cable Weight
Standard Length
22 AWG Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
2
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request.
I. Exchange Cables
Filled Foam Skin ALPETH Cable REA/RUS PE-89 62.89.01
CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 AND 19 AWG. INSULATION: Expanded polyethylene (Foam Skin) with an external layer of solid, high-density polyethylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and cross-talk.
All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and super-units are divided into 12 and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80° C) compound. Then covered with a non-hygroscopic tape with an overlap. A filling compound is applied over the wrap.
Outside plant telephony or underground installation.
Meets REA/RUS PE-89 ANSI/ICEA S-84-608-1994. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: AN_A
ISO-9001 Quality Assurance System
Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
3
26 AWG Product Code
Number of Pairs
Nominal OD
Approximate Cable Weight
Standard Length
In
mm
Lbs/kft
Kg/km
Ft
m
626081 626082 626083 626084 626086 626087 626088 626089 626090 626091 626093 626095
25 50 75 100 200 300 400 600 900 1200 1800 2400
0.55 0.59 0.77 0.89 1.08 1.30 1.46 1.69 1.93 2.30 3.00 3.19
14.0 15.0 19.5 22.5 27.5 33.0 37.0 43.0 49.0 58.5 76.0 81.0
137 228 302 369 650 925 1153 1686 2411 3239 4764 6246
205 340 450 550 970 1380 1720 2515 3640 4830 7105 9315
4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655 655
1500 1500 1500 1500 1500 1500 100 500 500 300 200 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626101 626102 626103 626104 626105 626106 626107 626109 626110 626111 626112 626113 626114
6 12 18 25 50 75 100 200 300 400 600 900 1200
0.45 0.51 0.59 0.67 0.77 0.87 0.96 1.20 1.54 1.71 2.05 2.52 2.91
11.5 13.0 15.0 17.0 19.5 22.0 24.5 30.5 39.0 43.5 52.0 64.0 74.0
70 107 144 194 302 396 506 949 1368 1680 2515 3628 5123
105 160 215 290 450 590 755 1415 2040 2505 3750 5410 7460
4920 4920 4920 4920 4920 4920 4920 3280 3280 2950 1640 1640 655
1500 1500 1500 1500 1500 1500 1500 1000 1000 900 500 500 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626120 626121 626122 626123 626124 626125 626126 626128 626129 626130 626131 626132
6 12 18 25 50 75 100 200 300 400 600 900
0.47 0.59 0.67 0.81 0.94 1.14 1.22 1.65 1.91 2.03 2.62 3.15
12.0 15.0 17.0 20.5 24.0 29.0 31.0 42.0 48.5 51.5 66.5 80.0
87 137 211 302 453 644 771 1482 2106 2602 4090 6025
130 205 315 450 675 960 1150 2210 3140 3880 6100 8985
4920 4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655
1500 1500 1500 1500 1500 1500 1500 1000 500 500 300 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626136 626137 626138 626139 626140 626141 626143 626144 626145
6 12 18 25 50 75 100 200 300
0.59 0.71 0.81 0.91 1.16 1.32 1.50 2.01 2.36
15.0 18.0 20.5 23.0 29.5 33.5 38.0 51.0 60.0
141 231 308 409 744 1063 1368 2635 3856
210 345 460 610 1110 1585 2040 3930 5750
4920 4920 4920 4920 3280 3280 1640 1640 985
1500 1500 1500 1500 1000 1000 500 500 300
24 AWG Nominal OD
Approximate Cable Weight
Standard Length
22 AWG Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
4
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request.
I. Exchange Cables
Filled Foam Skin CACSP Cable REA/RUS PE-89 62.89.02
CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 and 19 AWG. INSULATION: Expanded polyethylene (Foam Skin) with an external layer of solid, high-density polyethylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80°C) compound. Then covered with a non-hygroscopic tape with an overlap. Filling compound is also applied over the wrap.
All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and superunits are divided into 12 and 13 pairs sub-units. SHIELD: Corrugated, copolymer coated aluminum tape, 8-mil thick applied longitudinally with a gap. A flooding compound is applied over the shield. ARMOR: Corrugated shield of copolymer coated steel tape, 6-mil thick. A flooding compound with adhesive properties is applied over the armor. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
Outside plant telephony, direct burial or underground installation.
Meets REA/RUS PE-89 ANSI/ICEA S-84-608-1994. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: AN W
ISO-9001 Quality Assurance System
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
5
26 AWG Product Code
Number of Pairs
In
Nominal OD mm
Approximate Cable Weight Lbs/kft
Kg/km
Standard Length Ft
m
626280 626281 626282 626283 626285 626286 626287 626288 626290 626292 626294 626296
25 50 75 100 200 300 400 600 900 1200 1800 2400
0.51 0.59 0.75 0.87 1.08 1.30 1.40 1.63 2.28 2.83 3.15 13.0
15.0 19.0 22.0 27.0 32.0 35.5 41.5 49.0 58.0 72.0 80.0 145.0
235 312 386 690 925 1156 1230 1740 2548 3382 4964 6256
215 350 465 574 1027 1436 1830 2589 3790 5032 7386 9309
4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655 655
1500 1500 1500 1500 1500 1500 100 500 500 300 200 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626300 626301 626302 626303 626304 626305 626306 626308 626309 626310 626311 626313 626315
6 12 18 25 50 75 100 200 300 400 600 900 1200
0.40 0.51 0.57 0.65 0.75 0.87 0.94 1.18 1.50 1.69 1.97 2.44 2.84
11.0 13.0 14.5 16.5 19.0 22.0 24.0 30.0 38.0 43.0 50.0 62.0 72.0
89 127 164 198 322 439 546 997 1383 1820 2615 3878 5163
132 189 244 295 480 653 812 1484 2058 2708 3891 5770 7683
4920 4920 4920 4920 4920 4920 4920 4920 3280 3280 2950 1640 1640
655 1500 1500 1500 1500 1500 1500 1500 1000 1000 900 500 500
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626320 626321 626322 626323 626324 626325 626326 626328 626329 626330 626331 626333
6 12 18 25 50 75 100 200 300 400 600 900
0.47 0.59 0.67 0.77 0.91 1.06 1.22 1.54 1.77 2.03 2.50 3.03
12.0 15.0 17.0 19.5 23.0 27.0 31.0 39.0 45.0 51.5 63.5 77.0
104 167 221 287 478 644 831 1482 2106 2732 4090 6120
155 248 329 427 711 960 1237 2210 3140 4055 6100 9107
4920 4920 4920 4920 4920 4920 4920 3280 1640 1640 985 655
1500 1500 1500 1500 1500 1500 1500 1000 500 500 300 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626340 626341 626342 626343 626344 626345 626346 626348 626349
6 12 18 25 50 75 100 200 300
0.59 0.71 0.85 0.91 1.16 1.32 1.50 2.01 2.36
15.0 18.0 21.5 23.0 29.5 33.5 38.0 51.0 60.0
141 231 308 409 744 1063 1368 2635 3856
210 345 460 610 1110 1585 2040 3930 5750
4920 4920 4920 4920 3280 3280 1640 1640 985
1500 1500 1500 1500 1000 1000 500 500 300
24 AWG Nominal OD
Approximate Cable Weight
Standard Length
22 AWG Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
6
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request.
I. Exchange Cables
Aircore ALPETH Cable REA/RUS PE-22 62.22.01
CONDUCTORS: Solid, annealed copper wires, in 26, 24 22 and 19 AWG.
In order to have a rounder shape and better electrical performance, all units and superunits are divided into 12 and 13 pairs sub-units.
INSULATION: Solid, high-density polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and crosstalk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders.
SHIELD: Corrugated, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. JACKET: Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
Meets REA/RUS PE-22 ANSI/ICEA S-85-625-1996 Standard for Telecommunications Cable Air Core, Polyolefin Insulated, Copper Conductor. Telecordia (Bellcore) equivalent: BH A
ISO-9001 Quality Assurance System
Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
7
26 AWG Product Code
Number of Pairs
626001 626002 626003 626004 626005 626006 626007 626008 626009 626010 626011 626012 626013 626014 626015 626016 626017
12 18 25 50 75 100 150 200 300 400 600 900 1200 1500 1800 2100 2400
In 0.45 0.47 0.51 0.63 0.71 0.77 0.89 1.01 1.14 1.39 1.54 1.85 2.13 2.34 2.56 2.74 2.93
Nominal OD
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626025 626026 626027 626028 626029 626030 626031 626032 626033 626034 626035 626036 626037 626038 626039 626040
6 12 18 25 50 75 100 150 200 300 400 600 900 1200 1500 1800
0.39 0.47 0.51 0.55 0.71 0.81 0.87 1.04 1.18 1.40 1.57 1.87 2.28 2.60 2.85 3.11
10.0 12.0 13.0 14.0 18.0 20.5 22.0 26.5 30.0 35.5 40.0 47.5 58.0 66.0 72.5 79.0
62 81 107 133 225 314 396 596 767 1114 1447 2120 3153 4120 5085 6052
93 121 160 199 336 468 591 889 1144 16961 2158 3162 4702 6145 7583 9026
4920 4920 4920 4920 4920 4920 4920 3940 3940 3940 2950 1970 985 985 985 655
1500 1500 1500 1500 1500 1500 1500 1200 1200 1200 900 600 300 300 300 200
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626048 626049 626050 626051 626052 626053 626054 626055 626056 626057 626058 626059
6 12 18 25 50 75 100 150 200 300 400 600
0.43 0.52 0.55 0.63 0.79 0.91 1.04 1.22 1.38 1.63 1.87 2.32
11.0 13.0 14.0 16.0 20.0 23.0 26.5 31.0 35.0 41.5 47.5 59.0
76 115 148 190 329 460 607 895 1163 1688 2218 3292
114 171 221 284 490 686 905 1335 1734 2518 3308 4309
4920 4920 4920 4920 4920 4920 3940 3940 3940 2950 1970 985
1500 1500 1500 1500 1500 1500 1200 1200 1200 900 600 300
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626065 626066 626067 626068 626069 626070 626071 626072 626073
6 12 18 25 50 75 100 150 200
0.55 0.67 0.77 0.85 1.12 1.28 1.50 1.81 2.07
14.0 17.0 19.5 21.5 28.5 32.5 38.0 46.0 52.5
125 198 268 347 636 899 1186 1768 2326
187 295 400 517 949 1341 768 2637 3469
4920 4920 4920 3280 3280 3280 1970 1970 1970
1500 1500 1500 1000 1000 1000 600 600 600
mm 11.5 12.0 13.0 16.0 18.0 19.5 22.5 25.5 29.0 33.0 39.3 47.0 54.0 59.5 65.0 69.5 74.5
Approximate Cable Weight Lbs/kft 72 87 106 167 224 280 405 529 749 968 1405 2055 2692 3319 3964 4579 5206
Kg/km 106 130 158 248 334 418 604 789 1113 1443 2095 3065 4014 4949 5912 6828 7763
Standard Length Ft 4920 4920 4920 4920 4920 4920 4920 3940 3940 3940 2950 1970 1310 985 985 985 985
m 1500 1500 1500 1500 1500 1500 1500 1200 1200 1200 900 600 400 300 300 300 300
24 AWG Nominal OD
Approximate Cable Weight
Standard Length
22 AWG Nominal OD
Approximate Cable Weight
Standard Length
19 AWG
8
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request.
II. Buried Wire
Double Jacketed Buried Distribution Wire (Gopher resistent) PE-86 62.86.01
CONDUCTORS: Solid, annealed 22 AWG copper with a nominal diameter of 0.0250” (0.634 mm)
INNER JACKET Black, linear, low-density, high molecular weight polyethylene.
INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards.
SHIELD: Corrugated, copper-clad alloy steel (0.005” thick) tape applied longitudinally with an overlap. A flooding compound is applied on both sides of the tape.
PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths, with a maximum length of 6.5” (165 mm).
OUTER JACKET: Black, linear, low density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
CORE ASSEMBLY: The core is filled with ETPR (80°C) compound, then covered with a non-hygroscopic tape with an overlap. A filling compound is also applied over the wrap.
Service drop for telephony, underground installation or direct burial.
ANSI/ICEA S-86-634-1991 Standard for Telecommunications Cable Filled, Polyolefin Insulated, Cooper Conductor. Meets REA/RUS PE-86 (for 2 and 3 pair, 22 AWG when a bronze shield - BDW B or when a cooper clad steel armor - BDW G DJ is used)
ISO-9001 Quality Assurance System
Packaged on wooden reels that are lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
9
II. Buried Wire
Double Jacketed Buried Distribution Wire (Gopher resistent) PE-86 62.86.01
MECHANICAL PROPERTIES Number Of Pairs
Nominal OD In Mm
Cable Net Weight
Shipping Length
Approximate Shipping Weight Lbs kg
Lbs/kft
kg/km
FT
m
2
0.40
10.3
94
140
2500 or 5000
760 or 1520
292 558
132 253
3
0.44
11.1
110
162
2500 or 5000
760 or 1520
329 633
149 287
6
0.51
12.9
149
222
1000 or 2500 or 5000
305 or 760 or 1520
206 435 873
93 197 396
Note: Values shown are nominal, subject to manufacturing tolerances.
ELECTRICAL CHARACTERISTICS MUTUAL CAPACITANCE, average
83+7 nF/mile
-
CAPACITANCE UNBALANCE: Pair to pair Maximum Individual
80 pF/kft 145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum
800 pF/kft 2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
10
52+4 nF/km
Nominal dB/kft Nominal dB/km
11.0 6.8
HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield
5.0 20.0
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average
5% 1.5%
INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km
1,000 1,600
17.4 57.1
I. Exchange Cables
Filled ASP Cable, Foam Skin Insulation AN_W Telecordia (Bellcore) 62.AN_W.01
DESCRIPTION: CONDUCTORS: Solid, annealed copper wires, in 26, 24, 22 and 19 AWG. INSULATION: Expanded polyethylene (Foam Skin) with an external layer of solid, high-density polyethylene in distinctive colors, conforming to telephone industry standards. PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths to minimize capacitance unbalance and cross-talk. CORE ASSEMBLY: In cables with 25 pairs or less, the pairs are laid forming a cylindrical shape. For larger cables, units of 25 pairs or superunits of 50 or 100 pairs are assembled to form the final core. The core is filled with ETPR (80°C) compound. Then covered with a non-hygroscopic tape with an overlap. Filling compound is also applied over the wrap.
All units and superunits are identified with color coded, non-hygroscopic, non-wicking binders. In order to have a rounder shape and better electrical performance, all units and super-units are divided into 12 and 13 pair sub-units. SHIELD: Corrugated, bare aluminum tape, 8-mil thick applied longitudinally with an overlap. A flooding compound with adhesive properties is applied over the shield. ARMOR: A corrugated shield of steel tape, 6-mil thick. JACKET Black, linear, low-density, high molecular weight polyethylene. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
APPLICATION: Outside plant telephony, direct burial or underground installation.
REFERENCE SPECIFICATIONS: Telecordia (Bellcore) TR-NWT-00421/3. ANSI/ICEA 84-608-1988 Generic Requirements for metallic telecommunication cables.
CERTIFICATION: ISO-9001 Quality Assurance System
PACKAGING: Packaged on wooden reels with a thermal wrap applied over the cable. The reels are also lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
11
26 AWG ANTW Product Code
Number of Pairs
In
Nominal OD mm
Approximate Cable Weight Lbs/kft
Kg/km
Standard Length Ft
m
626220 626221 626223 626225 626226 626227 626228 626229 626230 626231 626232
25 50 100 200 300 400 600 900 1200 1800 2400
0.63 0.79 0.94 1.22 1.36 1.54 1.75 2.07 2.60 2.89 3.27
16.0 20.0 24.0 31.0 34.5 39.0 44.5 52.5 66.0 73.5 83.0
170 260 395 724 972 1240 1608 2513 3652 4256 6231
255 385 590 1080 1450 1850 2400 3750 5450 6350 9300
5900 5900 5900 5900 3940 3940 2950 1970 1475 985 820
1800 1800 1800 1800 1200 1200 900 600 450 300 250
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626238 626239 626241 626243 626244 626245 626246 626247 626248 626250
25 75 100 200 300 400 600 900 1200 1800
0.73 0.87 1.04 1.36 1.57 1.81 2.11 2.56 2.99 3.56
18.5 22.0 26.5 34.5 40.0 46.0 53.5 65.0 76.0 90.5
241 349 550 972 1408 1864 2548 3805 5076 7631
360 520 820 1450 2100 2780 3800 5675 7570 11,380
5900 5900 5900 3940 3940 3280 2950 1475 1475 655
1800 1800 1800 1200 1200 1000 900 450 450 200
24 AWG Nominal OD
Approximate Cable Weight
Standard Length
22 AWG Product Code
Number of Pairs
626250 626251 626252 626254 626255 626256 626257 626258
25 50 100 200 300 400 600 900
In 0.85 1.02 1.26 1.57 1.93 2.20 2.66 3.19
Nominal OD
Product Code
Number of Pairs
In
mm
Lbs/kft
Kg/km
Ft
m
626265 626266 626267 626268 626270 626271 626272
25 50 75 100 200 300 400
1.02 1.22 1.42 1.52 2.13 2.54 2.87
26.0 31.0 36.0 38.5 54.0 64.5 73.0
532 896 1228 1498 2895 4168 5423
793 1336 1832 2234 4318 6216 8088
4920 3280 3280 3280 1640 985 655
1500 1000 1000 1000 500 300 200
mm 21.5 26.0 32.0 42.5 49.0 56.0 67.5 81.0
Approximate Cable Weight Lbs/kft 322 489 831 1408 2045 2749 3856 5633
Kg/km 480 730 1240 2100 3050 4100 5750 8400
Standard Length Ft 5900 5900 3740 2950 2950 1970 1475 820
m 1800 1800 1200 900 900 600 450 250
19 AWG ANBW
12
Nominal OD
Approximate Cable Weight
Standard Length
Note: Values shown are nominal, subject to manufacturing tolerances. Special lengths are available upon request.
II. Buried Wire
Buried Service Wire (Aluminium shield, single jacket) BSW A 62.BSW.01
CONDUCTORS: Solid, annealed 22 AWG copper with a nominal diameter 0.0250” (0.634mm) INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards.
SHIELD: Smooth, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield. JACKET: Black, linear, low-density, high molecular weight polyethylene, able to withstand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meters) markings are printed on the jacket at 2 foot (or 1 m) intervals.
PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths, with a maximum length of 6.5” (165 mm). CORE ASSEMBLY: The core is filled with ETPR (80°C) compound. Then covered with a nonhygroscopic tape with an overlap. A filling compound is also applied over the wrap.
Service drop for telephony, underground installation or in ducts.
ANSI/ICEA S-86-634-1991 Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
ISO-9001 Quality Assurance System
Packaged on wooden reels that are lagged for additional protection
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
13
II. Buried Wire
Buried Service Wire (Aluminium shield, single jacket) BSW A 62.BSW.01
Number Of Pairs
Nominal OD In Mm
Cable Net Weight
Shipping Length
Approximate Shipping Weight Lbs kg
Lbs/kft
kg/km
FT
m
2
0.29
7.4
39
58
2500
762
139
63
3
0.32
8.2
48
72
2500
762
164
75
Note: Values shown are nominal, subject to manufacturing tolerances.
MUTUAL CAPACITANCE, average
83+7 nF/mile
-
CAPACITANCE UNBALANCE: Pair to pair Maximum Individual
80 pF/kft 145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum
800 pF/kft 2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
Nominal dB/kft Nominal dB/km HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield
14
52+4 nF/km
11.0 6.8 5.0 10.0
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average
5% 1.5%
INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km
1,000 1,600
17.4 57.1
II. Buried Wire
Double Jacketed Buried Distribution Wire (Aluminium shield, double polyethylene jacket) BDW A 62.BDW_A.01
DESCRIPTION: CONDUCTORS: Solid, annealed 22 AWG copper with a nominal diameter of 0.0250” (0.634mm)
INNER JACKET Black, linear, low-density, high molecular weight polyethylene.
INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, conforming to telephone industry standards.
SHIELD: Smooth, copolymer coated, 8-mil thick aluminum tape applied longitudinally with an overlap. The coating reduces the risk of shield corrosion. A flooding compound with adhesive properties is applied over the shield.
PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths, with maximum length of 6.5” (165 mm).
JACKET: Black, linear, low-density, high molecular weight polyethylene, able to withstand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
CORE ASSEMBLY: The core is filled with ETPR (80°C) compound. Then covered with a nonhygroscopic tape with an overlap. A filling compound is also applied over the wrap.
APPLICATION: Service drop for telephony, underground installation.
REFERENCE SPECIFICATIONS: ANSI/ICEA S-86-634-1991 Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
CERTIFICATION: ISO-9001 Quality Assurance System
PACKAGING: Packaged on wooden reels that are lagged for additional protection.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
15
II. Buried Wire
Double Jacketed Buried Distribution Wire (Aluminium shield, double polyethylene jacket) BDW A 62.BDW_A.01
MECHANICAL PROPERTIES Number Of Pairs
Nominal OD In Mm
Cable Net Weight
Shipping Length
Approximate Shipping Weight Lbs kg
Lbs/kft
kg/km
FT
m
2
0.35
8.9
52
62
2500
762
183
83
3
0.38
9.7
63
75
5000
1524
375
170
6
0.46
11.6
94
107
1000
305
148
67
Note: Values shown are nominal, subject to manufacturing tolerances.
ELECTRICAL CHARACTERISTICS MUTUAL CAPACITANCE, average
83+7 nF/mile
-
CAPACITANCE UNBALANCE: Pair to pair Individual Maximum
80 pF/kft 145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground Maximum Individual
800 pF/kft 2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual
Nominal dB/kft Nominal dB/km HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield
16
52+4 nF/km
11.0 6.8 5.0 20.0
D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average
5% 1.5%
INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km
1,000 1,600
17.4 57.1
II. Buried Wire
Buried Service Wire (Non-shielded, non-armored, single jacket)
BSW USJ 62.BSWUSJ.01
CONDUCTORS: Solid, annealed 22 AWG copper with a, nominal diameter 0.0250” (0.634mm) or 24 AWG with a nominal diameter of 0.0201” (0.511 mm)
CORE ASSEMBLY: The core is filled with ETPR (80°C) compound. Then covered with a nonhygroscopic tape with an overlap. A filling compound is also applied over wrap.
INSULATION: Solid, high-density, polyethylene or polypropylene in distinctive colors, according to telephone industry standards.
OUTER JACKET: Black, linear, low-density, high molecular weight polyethylene, able to withstand exposure to sunlight, ground humidity and chemicals. Sequential footage (or meter) markings are printed on the jacket at 2 foot (or 1 m) intervals.
PAIRS: Insulated conductors are twisted together to form pairs, with different twist lay lengths with a maximum length of 6.5” (165 mm).
Service drop for telephony or underground installation in ducts.
ANSI/ICEA S-86-634-1991. Standard for Telecommunications Cable Filled, Polyolefin Insulated, Copper Conductor.
ISO-9001 Quality Assurance System
On wooden reels that are lagged for additional protection.
Number Of Pairs
Nominal OD In Mm
Cable Net Weight
Shipping Length
Approximate Shipping Weight Lbs kft
Lbs/kft
kg/km
FT
m
2
-
-
-
-
-
-
-
-
4
0.33
8.3
47
70
5000
1520
292
132
6
0.37
9.5
64
95
1000 or 2500 or 5000
305 or 760 or 1520
112 215 373
51 98 169
Note: Values shown are nominal, subject to manufacturing tolerances.
Condumex Wire and Cable
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
17
II. Buried Wire
Buried Service Wire (Non-shielded, non-armored, single jacket)
BSW USJ 62.BSWUSJ.01
Number Of Pairs 2 4
6
Nominal OD In Mm
Cable Net Weight
Shipping Length
Lbs/kft
kg/km
FT
m
Approximate Shipping Weight Lbs kg
-
-
-
-
-
-
-
-
0.28
7.2
32
48
1000 2500 5000
305 760 1520
80 136 217
36 62 98
0.37
9.5
64
95
1000 or 2500 or 5000
305 or 760 or 1520
112 215 373
51 98 169
Note: Values shown are nominal, subject to manufacturing tolerances.
22 AWG
MUTUAL CAPACITANCE, average
83+7 nF/mile
-
52+4 nF/km
CAPACITANCE UNBALANCE: Pair to pair Maximum Individual
80 pF/kft 145 pF/km
CAPACITANCE UNBALANCE: Pair to Ground Individual Maximum
800 pF/kft 2625 pF/km
FEXT Far end CROSSTALK, dB/kft minimum Power Sum @150 kHz
63
NEXT Near end CROSSTALK, dB/kft minimum Power Sum @772 kHz
44
ATTENUATION @ 150 kHz @ 20°C, Maximum Individual Nominal dB/kft Nominal dB/km HIGH VOLTAGE TEST, d-c kV for 3 seconds Conductor to Conductor Conductor to Shield D-c CONDUCTOR RESISTANCE @ 20°C, Maximum Individual Ù/kft Ù/km RESISTANCE UNBALANCE Maximum Individual Maximum Average INSULATION RESISTANCE, Minimum MÙ · Mile MÙ · km
18
24 AWG
11.0 6.8
14.0 87
5.0 10.0
4.0 10.0
17.4 57.1
27.5 902 5% 1.5% 1,000 1,600
AERIAL SERVICE WIRE
62.ASW.01
DESCRIPTION: ¥ Bare copper 22 AWG conductors ¥ Color coded to industry standards ¥ Sunlight-resistant PVC jacket ¥ Solid, high-density polyethylene insulation ¥ Galvanized steel messenger wire 2.11mm O.D. ¥ Packaging available in reels, cartons and coils
APPLICATIONS: z Extending telephone circuits from a distribution terminal to a subscriber’s station protectors. z Aerial applications.
PROPERTIES: MECHANICAL PROPERTIES Pair Count
Conductor Diameter (mm)
Insulation Diameter (mm)
Overall Diameter (mm)
Net Weight (kg/km)
3 6
0.643 0.643
1.1 1.1
7 x 13 9 x 15
67 120
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS: Bellcore: GR-492-CORE
Bellcore: TR-NWT-000122
UL Listed
Quality System, ISO-9000
ELECTRICAL PROPERTIES c.d. Resistance DC Resistance Mutual Capacitance of Unbalance Capacitance Unbalance Conductor (Pair to Pair) (ohm/km) (nF/km) (pF/km) 56.5
5% max.
55.9 avg 58.4 max. ind.
Insulation Resistance (Megaohs-km)
145 max.
1600 min
TRANSMISSION CHARACTERISTICS Frequency KHz 150 772
Attenuation dB/km
NEXT dB/km
16.7
44 min.
Condumex Wire and Cable
FEXT dB/km 58 min.
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
8-04
19
O
OUTDOOR CABLES UP TO -40 C
ARMORED MACROTEL OPTICAL CABLE
69d90
SPECIFICATIONS: GR-20-CORE
APPLICATION & PROPERTIES: ¥ Installation in ducts or trays. ¥ Protection against rodents. ¥ Weather resistant. ¥ 6 to 288 fibers. ¥ Alternate cable direction to enable branching. ¥ External jacket with high friction strength.
MECHANICAL PROPERTIES Number of Fibers 6 to 72 84 to 216 228 to 288
Maximum Installation Tension N
Compression N/cm
2700
440
Minimum Bend Radius mm unloaded loaded 350 260 440 330 550 410
Operating Temperature O C -40 to +70
DESCRIPTION: 1. Dielectric central traction element. 2. Optical fibers in thermoplastic tubes (2 layers with 144 to 288 fibers). 3. Expandable tape as water protection.
DIMENSIONS
4. Fiberglass or aramid yarn as strength element. 5. Non-hygroscopic tapes and wires. 6. Internal polyethylene jacket. 7. Corrugate steel armor. 8. External black polyethylene jacket.
Number of Fibers
Fibers per Tube
Weight kg/km
Overall Diameter mm
6 to 36 48 to 72 84 96 108 120 132 to 216 228 to 288
6 12 12 12 12 12 12 12
163 195 251 251 310 310 371 371
15.7 17.2 19.4 19.4 21.4 21.4 24.2 24.2
1
8 7
5 3
¥Values shown are nominal, subject to manufacturing tolerances.
Condumex Wire and Cable
6
2
4 th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
20
O
OUTDOOR CABLES UP TO -40 C
DRY DIELECTRIC MACROTEL CABLE
69d96
SPECIFICATIONS: Bellcore GR-20
APPLICATION & PROPERTIES: ¥ Installation in ducts or trays. ¥ Aerial, attached to an external messenger. ¥ Weather resistant and resistance to water penetration. ¥ No metal elements
¥ 6 to 288 fibers. ¥ Filling material only in slack tubes, making splicing easy. ¥ Alternate cable direction to enable branching. ¥ External jacket with high friction strength.
MECHANICAL PROPERTIES Number Of Fibers 6 to 36 48 to 72 84 to 144 156 to 216
Maximum Installation Tension N
Compression N/cm
2700
220
Minimum Bend Radius mm unloaded loaded 180 240 200 270 300 390 300 400
Operating Temperature O C
-40 to +75
DESCRIPTION: DIMENSIONS Number of Fibers
Fibers per Tube
Weight kg/km
Overall Diameter mm
2 to 36 48 to 73 84 to 96 108 to 120 132 to 144 156 to 216 228 to 288
6 12 12 12 12 12 12
110 135 180 230 280 305 460
¥ Values shown are nominal, subject to manufacturing tolerances.
21
12.0 13.5 16.0 18.0 20.0 20.5 24.5
1.Dielectric central traction element. 2.Optical fibers in slack thermoplastic tubes. 3.Fiberglass or aramid yarn as strength element. 4.Expandable tape as water protection. 5.External medium-density polyethylene jacket.
5
1 4 2
3
O
OUTDOOR CABLES UP TO -40 C
DIELECTRIC DJ MACROTEL OPTICAL CABLE
69d97
SPECIFICATIONS: GR-20-CORE
APPLICATION & PROPERTIES: ¥ Installation in ducts or trays. ¥ Aerial, attached to an additional messenger. ¥ Weather resistant. ¥ No metal elements
¥ Double polyethylene jacket. ¥ 6 to 144 fibers. ¥ Alternate cable direction to enable branching. ¥ External jacket with high friction strength.
MECHANICAL PROPERTIES Numbers of Fibers 6 to 72 84 to 144
Maximum Installation Tension N
Compression N/cm
2700
220
Minimum Bend Radius mm unloaded Loaded 240 320 300 400
Operating Temperature O C -40 to +70
DESCRIPTION: 1.Dielectric central traction element. 2.Optical fibers identified by color. 3.Filled thermoplastic tube. 4.Expandable tape as water protection. 5.Non-hygroscopic tape and wires.
6.Internal polyethylene jacket. 7.Fiberglass or aramid yarn as strength element. 8.External black polyethylene jacket. 1
DIMENSIONS Number of Fibers
Fibers per Tube
Weight Kg/km
Overall Diameter
8
mm
6 to 36 48 to 72 84 96 108 120 132 144
6 12 12 12 12 12 12 12
170 195 235 265 290 325 360 385
2
13.5 16 17 18 19 20 21 22
7
3 6
4
¥ Values shown are nominal, subject to manufacturing tolerances.
Condumex Wire and Cable
5
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
22
O
OUTDOOR CABLES UP TO -40 C
DRY LIGHT ARMORED MACROTEL CABLE
69d99
SPECIFICATIONS: Bellcore GR-20
APPLICATION & PROPERTIES: ¥ Installation in ducts or trays. ¥ Aerial, attached to an external messenger. ¥ Weather resistant and resistance to water penetration. ¥ Armor for protection against rodents.
¥ 6 to 288 fibers. ¥ Filling material in buffer tubes. ¥ Alternate cable direction to enable branching. ¥ External jacket with high friction strength.
MECHANICAL PROPERTIES Number of Fibers 6 to 36 48 to 72 84 to 144 156 to 216
Maximum Compression Installation Tension N/cm N
2700
220
Minimum Bend Radius mm unloaded loaded 260 200 290 220 420 310 430 320
Operating Temperature O C
-40 to +75
DESCRIPTION: 1. Dielectric central traction element. 2. Optical fibers in thermoplastic tubes. 3. Fiberglass or aramid yarn as strength element.
4.Expandable tape as water protection. 5.Corrugate steel armor. 6.External medium-density polyethylene jacket.
DIMENSIONS Number of Fibers
Fibers per Tube
Weight kg/km
Overall Diameter
3 2
mm 2 to 36 48 to 72 84 to 96 108 to 120 132 to 144 156 to 216 228 to 288
6 12 12 12 12 12 12
165 195 255 310 375 385 550
¥ Values shown are nominal, subject to manufacturing tolerances.
23
13.5 15.0 17.0 19.0 21.0 21.5 25.5
1
6
4
5
RADIO FREQUENCY CABLES
1/2” (12.7mm) RF COAXIAL CABLE
68.RF.1/2
DESCRIPTION: ¥ Core conductor of copper coated aluminum ¥ Foamed polyethylene insulation with solid polyethylene internal and external layer
¥ Corrugated copper external conductor ¥ Jacket of black polyethylene
APPLICATIONS: z Jumpers in microwave or cellular telephony systems
PROPERTIES: ¥ Low loss insulation ¥ High conductivity
¥ External corrugated conductor increases flexibility ¥ Available in specific lengths upon request, with or without connectors
MECHANICAL PROPERTIES Core Conductor Diameter
Insulation Diameter
Diameter Over External Conductor
Overall Diameter
Minimum Bend Radius
Packaging Standard Lengths
Net Weight kg/km
4.8 mm
12.7 mm
14 mm
16 mm
125 mm
500 m
253
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS: Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES c.d. Resistance c.d. Resistance Characteristic Stationary of Core of External Impedance Wave Ratio Conductor Conductor VSWR 1.48 W/km
1.65 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance Speed 88%
76 pF/m
Dielectric Strength 4000 volts
ATTENUATION AND AVERAGE POWER Frequency MHz 10 50 150 300 500 800 960
Attenuation dB/100 m 0.69 1.58 2.78 4.08 5.25 6.79 7.50
Condumex Wire and Cable
Average Power kW 24.8 4.80 2.80 1.90 1.40 1.15 1.00
Frequency MHz 1500 2000 3000 4000 5000 6000 8000
Attenuation dB/100 m 9.60 11.2 14.3 16.6 19.5 21.8 26.0
Average Power kW 0.80 0.70 0.55 0.45 0.40 0.35 0.30
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
24
RADIO FREQUENCY CABLES
7/8” (22.2mm) RF COAXIAL CABLE
68.RF.7/8
DESCRIPTION: ¥ Copper tube core conductor ¥ Foamed polyethylene insulation with solid polyethylene internal and external layer
¥ Corrugated copper external conductor ¥ Jacket of black polyethylene
APPLICATIONS: z Connection of antennas in microwave or cellular telephony systems.
PROPERTIES: ¥ Low loss insulation ¥ High conductivity
¥ External corrugated conductor increases flexibility ¥ Available in specific lengths upon request
MECHANICAL PROPERTIES Core Conductor Diameter
Insulation Diameter
Diameter Over External Conductor
Overall Diameter
Minimum Bend Radius
Packaging Standard Lengths
Net Weight kg/km
9.02 mm
22.2 mm
24.8 mm
27.6 mm
250 mm
500 m
508
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS: Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES c.d. Resistance c.d. Resistance Characteristic Stationary of Core of External Impedance Wave Ratio Conductor Conductor VSWR 1.06 W/km
1.06 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance Speed 89%
75 pF/m
Dielectric Strength 6000 volts
ATTENUATION AND AVERAGE POWER Frequency MHz 10 50 150 300 400 500 700
25
Attenuation dB/100 m 0.37 0.85 1.50 2.18 2.58 2.90 3.51
Average Power kW 24.6 10.7 6.0 4.2 3.6 3.1 2.6
Frequency MHz 800 960 1500 2000 3000 4000 5000
Attenuation dB/100 m 3.79 4.20 5.46 6.47 8.32 9.93 11.5
Average Power kW 3.79 2.1 1.7 1.4 1.1 0.9 0.8
RADIO FREQUENCY CABLES
1-1/4” (31.75mm) RF COAXIAL CABLE
68.RF.1-1/4
DESCRIPTION: ¥ Copper tube core conductor ¥ Foamed polyethylene insulation with solid polyethylene internal and external layer
¥ Corrugated copper external conductor ¥ Jacket of black polyethylene
APPLICATIONS: z Connection of antennas in microwave or cellular telephony systems.
PROPERTIES: ¥ Low loss insulation ¥ High conductivity
¥ External corrugated conductor increases flexibility ¥ Available in specific lengths upon request
MECHANICAL PROPERTIES Core Conductor Diameter
Insulation Diameter
Diameter Over External Conductor
Overall Diameter
Minimum Bend Radius
Packaging Standard Lengths
Net Weight kg/km
13.1 mm
31.75 mm
34.7 mm
38.7 mm
380 mm
500 m
970
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS: Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES c.d. Resistance c.d. Resistance Characteristic Stationary of Core of External Impedance Wave Ratio Conductor Conductor VSWR 0.71 W/km
0.41 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance Speed 89%
75 pF/m
Dielectric Strength 10,000 volts
ATTENUATION AND AVERAGE POWER Frequency MHz 10 50 108 150 300 400 500
Attenuation dB/100 m 0.28 0.63 0.94 1.12 1.62 1.89 2.15
Condumex Wire and Cable
Average Power kW 36.9 16.1 10.8 9.1 6.3 5.3 4.7
Frequency MHz 700 800 960 1250 1500 2000 3000
Attenuation dB/100 m 2.58 2.79 3.09 3.60 4.02 4.76 6.08
Average Power kW 3.9 3.6 3.3 2.8 2.5 2.1 1.7
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
26
RADIO FREQUENCY CABLES
1-5/8” (41.275mm) RF COAXIAL CABLE
68.RF.1-5/8
DESCRIPTION: ¥ Corrugated copper tube core conductor ¥ Foamed polyethylene insulation with solid polyethylene internal and external layer
¥ Corrugated copper external conductor ¥ Jacket of black polyethylene
APPLICATIONS: z Connection of antennas in microwave or cellular telephony systems.
PROPERTIES: ¥ Low loss insulation ¥ High conductivity
¥ External corrugated conductor increases flexibility ¥ Available in specific lengths upon request
MECHANICAL PROPERTIES Core Conductor Diameter
Insulation Diameter
Diameter Over External Conductor
Overall Diameter
Minimum Bend Radius
Packaging Standard Lengths
Net Weight kg/km
17.3 mm
41.3 mm
46 mm
49.5 mm
510 mm
500 m
1170
* Values shown are nominal, subject to manufacturing tolerances.
SPECIFICATIONS: Quality System, ISO-9001.
MIL-C-28830
ELECTRICAL PROPERTIES c.d. Resistance c.d. Resistance Characteristic Stationary of Core of External Impedance Wave Ratio Conductor Conductor VSWR 0.67 W/km
0.32 W/km
50 + 1W/km
1.2 minimum
Propagation Capacitance Speed 88%
75 pF/m
Dielectric Strength 11,000 volts
ATTENUATION AND AVERAGE POWER Frequency MHz 10 50 108 150 300 500 700
27
Attenuation dB/100 m 0.23 0.51 0.77 0.92 1.34 1.78 2.18
Average Power kW 51.0 22.1 14.7 12.4 8.4 6.3 5.2
Frequency MHz 800 960 1500 1700 2000 2300 2500
Attenuation dB/100 m 2.35 2.62 3.43 3.71 4.09 4.47 4.72
Average Power kW 4.8 4.3 3.3 3.1 2.7 2.5 2.4
TRUNK AND DISTRIBUTION CABLE
68.TR.02
AVAILABLE OPTIONS: Self Supporting Cable with Messenger of 7 x 2 mm 750 Bare Cable 500 / 625 / 750 Self Supporting Cable with Messenger 2.77 mm 500 / 625 Jacketed Cable 500 / 625 / 750 Self Supporting Cable with Messenger of 7 x 1 mm 500 / 625 / 750 Flooded constructions are also available
PROPERTIES: Cable Type
Central Conductor
Resistance Aluminum
Tube Resistance
Impedance
Capacitance
Ù/km
Ù/km
Ù
pF/m
%
4.4 2.76 1.87
1.24 0.75 0.62
75 + 2
50 + 3
87
500 625 750
Cable Central Cond. Insulation Aluminum Overall Diameter Minimum Bend Type Diameter Diameter Tube Diameter (With Jacket) Radius mm
mm
mm
mm
mm
500
2.77
11.43
12.70
14.3
625
3.48
14.30
15.88
17.4
750
4.24
17.22
19.05
21.0
100 (bare) 90 (jacketed) 127 (bare) 114 (jacketed) 180 (bare) 150 (jacketed)
In all cases, installation stress is 3,000 N with standard section lengths of 716 m.
Messenger (Optional)
Messenger Type Available for Style
Diameter of Steel Messenger
Rupture Load N
7 x 1 mm 7 x 2 mm 2.77 mm
500, 625, 750 750 500, 625
3.1 mm 6.2 mm 2.77 mm
7,600 29,500 8,000
Frequency 500 Mhz 5 0.5 30 1.3 55 1.8 108 2.5 150 2.9 183 3.3 250 3.9 300 4.3 400 5.0 500 5.7 600 6.3 750 7.1 1000 8.3
2
625
750
0.4 1.0 1.5 2.1 2.5 2.8 3.3 3.4 4.2 4.7 5.2 5.8 6.8
0.4 0.8 1.2 1.7 2.0 2.2 2.7 2.9 3.4 3.9 4.3 4.9 5.7
5
2
3
4. Polyethylene jacket (optional).
Condumex Wire and Cable
Attenuation [dB/100m]
1
2. Gas injected foam polyethylene insulation.
5. Steel messenger (figure 8 construction).
30
1
1. Central conductor made of copper clad aluminum.
3. Outer conductor, high-purity aluminum tube.
Velocity of Propagation
3
4
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
7-04
28
Notes:
Condumex Wire and Cable 11-05
th
2590 114 Street - Grand Prairie, TX 75050 - (800) 925-9473
SOUTHWEST, INC. 3900 Dennis • Houston, Texas, 77004 (713)748-8200 • Fax: (713)748-4304 (800)725-9473
[email protected] Grand• Prairie, Texas
800-925-9473