Transcript
FarReach™ Drill Pipe 4” SPECIFICATIONS Drill Pipe Dimensions and Materials Pipe Body New Premium OD (in) 4.200 4.016 Wall Thickness (in) 0.460 0.368 Wear Band Diameter (in) 4.200 Remaining Body Wall (%) 100.00% 80.0% Reduction in OD (%) 0.00% 4.4% ID (in) 3.280 3.280 Alloy / Temper 2014-T6 Yield Strength (ksi) 58 Modulus (msi) 10.6 Cross Sectional Area (in^2) 5.405 4.217 Tool Joint NC46 Connection New Premium OD (in) 5.750 5 10/32 ID (in) 3.280 3.280 Box Tong Length, Lb (in) 10.900 Pin Tong Length, Lp (in) 6.400 Yield Strength (ksi) 120 Drill Pipe Assembly Data Open Displacement Shoulder to Shoulder Length (ft) 30.00 (US gal/ft) Closed Displacement Approximate Weight (lb) 285 (US gal/ft) Adjusted Weight (lb/ft) 9.49 Capacity (US gal/ft) Drill Pipe Mechanical Performance Pipe Body New Premium Tensile Strength (lbf) 313,000 245,000 Torsional Strength (ft-lbf) 25,500 19,700 80% Torsional Strength (ft-lbf) 20,400 15,700 Collapse Pressure (psi) 11,800 9,190 Internal Yield Pressure (psi) 11,100 10,600 Tool Joint New Premium Tensile Strength (lbf) 883,000 663,000 Torsional Strength (ft-lbf) 32,500 15,700 Recommended Make-Up Torque (ft-lbf) 19,500 9,450 Balanced OD (in) 5.71 5.71 Torsional Ratio TJ/Pipe 1.28 0.800
Class 2 3.924 0.322 70.0% 6.6% 3.280
3.644
Class 2 5 8/32 3.280
0.34 0.79 0.45
Class 2 211,000 16,900 13,500 7,710 9,520 Class 2 604,000 13,500 8,130 5.71 0.800
Alcoa FarReach™ Drill Pipe delivers the industry’s
This lightweight, high-strength combination allows
highest strength-to-weight ratio, improved hydraulic
for drilling to much greater depths and distances
performance, optimized wear characteristics, and a
with existing drilling equipment. Find out more
high level of corrosion resistance.
about FarReach™, and how it can help your
FarReach™ Drill Pipe enables extending the reach of
operation go farther, starting today.
Tong sizes 2in longer than standard.
your operation in deepwater, horizontal drilling and other Extended Reach Drilling (ERD) applications.
Drill Pipe Mechanical Performance Notes: (1) Tensile strength based on minimum yield strength. (2) Torsional strength based on shear strength equal to 57.7% of minimum yield strength. (3) Collapse pressure calculated per ISO/DIS 20312. (4) Internal yield pressure calculated per API Bullentin 5C3 which includes a 12.5% knockdown for new pipe. (5) Performance calculated with frictional factor and safety factor of 1.0.
For more information on how Alcoa can help you leverage high strength-to-weight aluminum alloy (6) All data based on nominal dimensions and calculated per standard methods unless otherwise noted. technology, visit AlcoaOilandGas.com. (7) Pipe properties base on pipe dimensions (non-upset area). (8) These data are intended for a preliminary evaluation of this configuration.
© 2013 Alcoa Oil & Gas. All rights reserved. AO1151 1013 Report Number: 20131009-136 Revision: 1.0 Revision Date: 20-DEC-2010