Preview only show first 10 pages with watermark. For full document please download

4x4 Half Duplex Switch - Formerica Optoelectronics

   EMBED


Share

Transcript

10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Specification 10G Ethernet Optical Bypass Module Dual Ports 10G Base-SR OBM–B1CH2–P01 Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 1 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Product Overview Formerica’s Dual Port 10 Gbit/s Optical Bypass Module(OBM) is a compact module that contains four 10 G Base-SR ports and can be integrated with I/O port controllers in a Network Interface Card (NIC). This module is targeted for maintaining network connectivity when power failure or system fails in an In-Line Network System. Formerica’s Dual Port 10 Gbit/s Optical Bypass Module supports Normal and Bypass modes, and can be configured to perform the Block mode. In Normal mode, two ports function independently. In Bypass mode, signal packets received from one port are loop-backed to the adjacent port. In Block mode, the module blocks the route. Formerica’s Dual Port 10 Gbit/s Optical Bypass Module can Bypass or Block its I/O ports upon a host system failure, power off, or by software request. Formerica’s Dual Port 10 Gbits Optical Bypass Module can be integrated with any brand’s Controllers CPU. It is suitable for connecting with in-line equipment for power failure or system maintenance. When the In-Line unit is not on or is in bypass mode, the relays within the OBM are set to bridge the optical signals directly through the optical switch, completely bypassing the In-Line equipment. Formerica’s OBM module provides excellent performance and reliable Optical Bypass and Block functions. All routing fibers, switches and electronics network are enclosed in a save and compact housing which provides save and space saving to networking equipment. Features       Reliable Passive Fiber Bypass (Latching) Compact Format and ROHS Compliant Low Return Loss Available in 50/125μm Multimode Fiber PCB Mountable Type Fast Ethernet Standard Compliant     Digital Diagnostic SFF-8472 Rev.10.2 Compliant SONET/SDH Standard Compliant Two Dual LC Adapters Class 1 Laser Product Complies with EN 60825-1  10 G-BASE-SR are available Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 2 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Block Diagram and Optical Paths O 5±0.5V_100mA_OSW1 Bypass/Normal_OSW (High: 3.3V) 3.3V_1.6A_O/E_TX/RX 4x4 Optical Switch 1 TX1 RX1 A0 Normal Mode O/E_0 TX2 LC Adapter RX2 O/E_0_TD- S O/E_0_RD+ P O/E_0_RD- E O/E_0_TDIS 3.3V_O/E_0_RX B0 Normal Mode X A1 Bypass Mode Normal Mode Bypass Control Logic WDT O/E_0_TD+ Normal Mode Quad H I G H 3.3V_O/E_1_TX O/E_1_TD+ O/E_1_TD- B1 O/E_1 O/E_1_RD+ O/E_1_RDO/E_1_TDIS 3.3V_O/E_1_RX Bypass Status Feedback_OSW E D C O N N E C T O R Ethernet I/O Controller With GPIO Ports Dual Ports Optical Bypass Module Link1 Speed1 Link2 Speed2  Link1 and Link2 indications:  Green: Link Speed1 and Speed2 indications: Blue: Data rate 10.3125G Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 3 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Module Outline Drawing ( mm) 23 22 2 1 Bottom View 43 84 42 1 Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 4 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 PIN Assignments of 84 pins Connector: Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Name GND On-Line GND OE1 TX Disable OE1 TX Fault OE1 MOD-DEF2 OE1 MOD-DEF1 OE1 Vcc OE1-Link OE1-Speed OE1 Rate Select GND GND OE2 TX Disable OE2 TX Fault OE2 MOD-DEF2 OE2 MOD-DEF1 OE2 Vcc OE-2-Link OE-2-Speed OE2 Rate Select GND I/O Function Note O 1K Ohm to Ground I O I/O I Transmitter Disable for OE-1 Transmitter Fault Indication for OE-1 2 Wire Serial ID Interface (Data) for OE-1 2 Wire Serial ID Interface (Clock) for OE-1 3.3V for Tx1 Power Supply and Rx1 Power Supply – 300mA OE1-Link LED Indicator (Voltage Low/ LED Green) OE1-Speed LED Indicator (Voltage Low / LED Blue) High: 10 Gbps; Low: 1.25 Gbps 2 1 3 3 2 1 3 3 I I I Transmitter Disable for OE-2 Transmitter Fault Indication for OE-2 2 Wire Serial ID Interface (Data) for OE-2 2 Wire Serial ID Interface (Clock) for OE-2 3.3V for Tx2 Power Supply and Rx2 Power Supply – 300mA OE2-Link LED indicator (Voltage Low / LED Green) OE2-Speed LED indicator (Voltage Low / LED Blue) High: 10 Gbps; Low: 1.25Gbps I I 5.0V Power Supply (OSW 1 Power) Change to Normal mode for OSW1 Change to Bypass mode for OSW1 8 7/9 7/9 O High=Normal Mode, Low=Bypass Mode for OSW1 I I I I O I/O I GND GND Vcc5_1 OSW 1 N1 OSW 1 B1 OSW 1 State Output Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 5 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Pin Number 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 Name I/O OE2 LOS OE2 GND OE2 RDOE2 RD+ OE2 GND OE2 GND OE2 TD+ OE2 TDOE2 GND O OE1 LOS OE1 GND OE1 RDOE1 RD+ OE1 GND OE1 GND OE1 TD+ OE1 TDOE1 GND O O O I I O O I I Function Note Loss of Signal for OE-2 OE2 Signal Ground OE2 Inversed Data Output OE2 Data Output OE2 Signal Ground OE2 Signal Ground OE2 Data Input OE2 Inversed Data Input OE2 Signal Ground 4 Loss of Signal for OE-1 OE1 Signal Ground OE1 Inversed Data Output OE1 Data Output OE1 Signal Ground OE1 Signal Ground OE1 Data Input OE1 Inversed Data Input OE1 Signal Ground 4 5 5 6 6 5 5 6 6 84 Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 6 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 PIN Assignments of 23 pins Connector: Pin Number 1 2 3 4 5 6 Name I/O Vcc5_1 Vcc5_1 OE1-Link I OE1-Speed I OE2-Link I OE2-Speed I Function Note 5.0V Power Supper (OSW1 Power) 5.0V Power Supper (OSW1 Power) No Connector OE1-Link LED Indicator (Voltage Low/ LED Green) No Connector OE1-Speed LED Indicator (Voltage Low / LED Blue) No Connector 7 8 9 10 11 OSW 1 State Output GND GND 12 13 14 15 16 17 18 19 20 21 22 23 O OSW 1 B1 I OSW 1 N1 I OE2-Link LED indicator (Voltage Low / LED Green) No Connector OE2-Speed LED indicator (Voltage Low / LED Blue) No Connector High=Normal Mode, Low=Bypass Mode for OSW1 No Connector Change to Bypass mode for OSW1 No Connector Change to Normal mode for OSW1 No Connector No Connector No Connector No Connector No Connector Notes: 1. TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor on the host board. Pull up voltage is between 2.0V and VccT, R+0.3V. When voltage of TX Fault is high, the output indicates a laser fault of some kind. Low indicates normal operation. In the low state, the output will be pulled to < 0.5V. 2. TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module with a 4.7 – 10 K Ω resistor. Its states are:  Low (0 – 0.8V): Transmitter on  (>0.8, < 2.0V): Undefined  High (2.0 – 3.465V): Transmitter Disabled  Open: Transmitter Disabled 3. Mod-Def 1,2, These are the module definition pins. They should be pulled up with a 4.7K – 10KΩ resistor on the host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID 4. LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10KΩ resistor. Pull up voltage lies between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In the low state, the output will be pulled to < 0.5V. Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 7 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 5. RD-/+: These are the differential receiver outputs. They are AC-coupled 100Ω differential lines which should be terminated with 100Ω (differential) at the user SERDES. The AC coupling is done inside the module and is thus not required on the host board. The voltage-swing on these lines will be between 350 and 850 mV differential (175 – 425 mV single ended) when properly terminated. 6. TD-/+: These are the differential transmitter inputs. They are AC-coupled differential lines with 100Ω differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. The inputs will accept differential swings of 180 – 700 mV (90 – 350 mV single-ended). 7. Latching Type - The input is used to control the optical switch mode for OSW  Normal mode:   OSW N1: > 3.75V and OSW B1 < 0.5V and over 20ms. Bypass mode:  OSW N1: < 0.5V and OSW B1 >3.75V and over 20ms 8. Non-Latching Type - High =Normal Mode, Low=Bypass Mode for OSW. 9. Non-Latching Type - Pin 43, 44, 82 and 83: Ground Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 8 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Absolute Maximum Ratings Parameter Symbol Min. Storage Temperature Ts Supply Voltage Vcc Typ. Max. Unit -40 85 ℃ 0 5 V Recommended Operating Conditions Parameter Symbol Min. Tc +5.0V Supply Voltage +3.3V Supply Voltage Case Operating Temperature Max. Unit Note 0 70 ℃ 1 Vcc5 4.75 5.25 V Vcc5 Vcc3 3.10 3.50 V 5 85 % 10.3125 +100ppm Gbps Typ. Max. Unit Relative Hunidity (non condensation) Data Rate -100ppm Typ. Note1 : Please see order information Electrical Characteristics Parameter Symbol Min. +5.0V Supply Current Icc5 100 mA +3.3V Supply Current Icc3 1200 mA Note Transmitter Transmitter Differential Input Voltage VDT 180 700 mV Transmitter Disable Input-High VDISH 2 Vcc+0.3 V Transmitter Disable Input-Low VDISL 0 0.8 V RTX FAULT 4.7 10 KΩ 2 Transmitter Fault Output-High VTXFH 2.4 Vcc V 2 Transmitter Fault Output-Low VTXFL 0 0.5 V 2 Transmitter Fault Pull up Resistor 1 Receiver Receiver Differential Output Voltage VDR 350 850 mV 3 Receiver LOS Load RRXLOS 4.7 10 KΩ 2 LOS Output Voltage-High VLOSH 2.4 Vcc V 2 LOS Output Voltage-Low VLOSL 0 0.5 V 2 5.25 V 0.8 V Optical Switch Latching Voltage-High VLATH 4.75 Latching Voltage-Low VLATL 0 Latching Resistance RLAT Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 5 125 Ω Version 02 9 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Notes: 1. Internally AC coupled and terminated to 100 Ohm differential load. 2. Pull up to Vcc on Host Board. 3. Internally AC coupled, but requies a 100Ohm differential termination at or internal to Serializer/Deserializer. Optical Characteristics (Tc=0~70℃, Data Rate=10.3125Gb/sec, PRBS=231-1 NRZ) Multimode Fiber Type Parameter Operating Range 62.5um MMF OM1 50um MMF OM2 50um MMF OM3 Parameter Min. Modal Bandwidth (MHz*km) 200 500 2000 Symbol Min. Operating Range (m) Maximum Channel Intertion Loss (dB) 20 to 33 2 to 82 2 to 300 1.6 1.8 2.6 Typ. Max. Unit Note -1 dBm 1 Transmitter Output Optical Power(Avg.) Po -7.1 Optical Extinction Ratio ER 3.5 Center Wavelength λC 840 Spectral Width (RMS) σ dB 850 860 nm 0.45 nm -11.1 dBm 860 DBm -12 dB -14 dBm Receiver Sensitivity (OMA) PIN Input Optical Wavelength λ 840 Return Loss LOS-Deasserted (Avg.) PA LOS-Asserted (Avg.) PD -30 dBm PA – PD 0.5 dB LOS-Hysteresis Overload Po -1 dBm 1,2 Optical Switch Wavelength Range λR 670 980 nm Insertion Loss OIL 0.9 1.8 dB Return Loss ORL 30 dB Switch Time 8 7 Lifetime Latching Resistance Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 RLAT ms ≧10 times 125 Ω Version 02 10 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 Notes: 1. Normal Mode (Bypass off). 2. The sensitivity provided at a BER of 1×10-12 or better with an input signal consisting of 10.3125Gb/s, 231 -1 PRBS Package Outline Drawing (mm) TOP View Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 11 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 EEPROM Serial ID Memory Contents (2-Wire Address A0H) Address HEX 00 01 02 03 04 05 06 07 03 04 07 10 00 00 00 20 08 40 09 10 11 0C 80 06 12 67 13 14 15 00 00 00 16 08 17 03 18 00 19 1E 20 ~ 35 36 37 ~ 39 40 ~ 55 56 ~ 59 60 ~ 61 62 63 64 65 66 67 68 ~ 83 84 ~ 89 90 ~ 91 92 93 Name of Field Description Identifier Extended Identifier Connector type 10G Ethernet Compliance Codes SONET Compliance Codes SONET Compliance Codes Ethernet Compliance Codes Fiber Channel link length Fiber Channel transmitter technology Fiber Channel transmission media Fiber Channel speed Encoding codes: Nominal Bit Rate (units of 100Mbps) Rate identifier Link length supported for 9um fiber Link length supported for 9um fiber Link length supported for 50um,OM2 Link length supported for 62.5um,OM1 Link length supported for copper Link length supported for 50um,OM3 SFP SFP LC 10G Base SR Not compliant Not compliant 1000BASE-LX intermediate distance (I) Shortwave laser w/o OFC (SN) Multimode 62.5um and 50um 1200 MBytes/sec 64B/66B 46,4F,52,4D,45,52,49,43 Vendor Name ,41,4F,45,20,20,20,20,20 00 Unallocated 00,00,00 Vendor OUI 4F,42,4D,2D,42,31,43,48,32, Part Number 2D,50,30,31,20,20,20 00,00,00,00 Vendor Revision number 03,52 Laser Wavelength 00 Unallocated CC_BASE: 00 Options 1A Options 00 Bit Rate, max. 00 Bit Rate, min. Serial Number Serial Number yy/mm/dd Date Code 20,20 Vendor specific lot code 68 Diagnostic Monitoring Type B0 94 03 95 96~127 Enhanced Options (soft) SFF-8472 Compliance CC_EXT Vendor specific Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 10.3Gbps Unspecified N/A (units of km) N/A (units of 100m) 80 m (units of 10m) 30 m (units of 10m) N/A (units of 1m) 300m (units of 10m) FORMERICAOE Unspecified OBM-B1CH2-P01 Unspecified 850nm Check sum of byte 0 ~ 62 TX-DIS, TX_FAULT, RX-LOS Unspecified Unspecified Unspecified Internal calibration Alarm/Warning flags, Soft TX_FAULT, Soft RX_LOS, implemented Rev10.2 Check sum of byte 64 ~ 94 Version 02 12 10G Ethernet Optical Bypass Module PRODUCT NUMBER: OBM-B1CH2-P01 EEPROM Serial ID Memory Contents (2-Wire Address A2H) Add Bytes Name Hex Real Value 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-33 34-35 36-37 38-39 40-55 56-59 60-63 64-67 68-71 72-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 16 4 4 4 4 4 2 2 2 2 2 2 2 2 3 1 Temp High Alarm Temp Low Alarm Temp High Warning Temp Low Warning Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm TX Power Low Alarm TX Power High Warning TX Power Low Warning RX Power High Alarm RX Power Low Alarm RX Power High Warning RX Power Low Warning Reserved RX_PWR(4) RX_PWR(3) RX_PWR(2) RX_PWR(1) RX_PWR(0) TX_I(Slope) TX_I(Offset) TX_PWR(Slope) TX_PWR(Offset) T(Slope) T(Offset) V(Slope) V(Offset) Reserved Checksum 4600 70℃ 0000 4400 0200 8CA0 7530 88B8 7918 1964 01F4 1770 02EE 2710 0630 22D0 06F2 2710 0232 22D0 0276 00 00000000 00000000 00000000 3F800000 00000000 0100 0000 0100 0000 0100 0000 0100 0000 00 - 0℃ 68℃ 2℃ 3.6V 3.0V 3.5V 3.1V 13mA 1mA 12mA 1.5mA 0dBm -8dBm -0.5dBm -7.5dBm 0dBm -12.5dBm -0.5dBm -12.01dBm 0 0 0 1 0 1 0 1 0 1 0 1 0 - Appendix A. Document Revision Version No. Date Description Version No. Date Description Version No. Date Description V01 V02 2013/09/09 2013/09/18 First release Add Module LED Status Formerica Optoelectronics Inc . 4F, No.31, Xintai Rd, Zhubei City, Hsinchu County 302, Taiwan Ph: +886-3-5512858 Fax: +886-3-5537118 Version 02 13