IC TRON C E L E NOTE SION ONLY VER GAS FURNACES G61MPV DAVE LENNOX SIGNATUREt COLLECTION ENGINEERING DATA Multi−Position − Variable Speed Blower Direct Vent/Non−Direct Vent − Two−Stage Heat AFUE up to 94.6% Input − 66,000 to 132,000 Btuh Nominal Add−on Cooling − 2 to 5 tons Duralok Plus® Aluminized Steel Heat Exchanger Sight Glass Pressure Switches Aluminized Steel Inshot Burners Factory installed Field Wiring Make−Up Box can be installed on either side Bulletin No. 210390 August 2003 Combination Two−Stage Gas Control Valve Tool−Less Entry Gas and electrical connections from either side of cabinet Terminals for Accessory Connections (powered air cleaners and humidifiers) Two−Stage Combustion Air Inducer Variable−Speed Slide−Out Blower SureLight® Patented Hot Surface Ignition System Two Stage / Variable Speed Blower Control Board with Diagnostic LED’s Heavy−Duty Transformer Low Voltage Circuit Breaker MODEL NUMBER IDENTIFICATION G 61 MP V− 36 B 070 Unit Type G = Gas Furnace Series 61 = Two−Stage 90% AFUE Configuration MP = Multi−Position Blower V = Variable Speed Blower Motor Nominal Add−On Cooling Capacity 36 = 1−3 tons (3.5−10.6 kW) 60 = 4−5 tons (14.0−17.6 kW) 1 Evaporator 1 Cabinet Width B = 17−1/2 in. (445 mm) C = 21 in. (533 mm) D = 24−1/2 in. (622 mm) Nominal Gas Heat Input 070 = 66,000 Btuh (19.3 kW) 090 = 88,000 Btuh (25.8 kW) 110 = 110,000 Btuh (32.2 kW) 135 = 132,000 Btuh (38.7 kW) coils with the same letter designation will physically match the furnace. FEATURES CONTENTS Blower Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 13−17 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 8−13 Exhaust Pipe Venting Table . . . . . . . . . . . . . . . . . . . . . . Page 4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 1−3 Filter Air Resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7 High Altitude Information . . . . . . . . . . . . . . . . . . . . . . . . . Page 4 Installation Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 7 Model Number Identification . . . . . . . . . . . . . . . . . . . . . . Page 1 Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . Pages 3−4 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 5−6 WARRANTY Duralok Plus® Aluminized Steel Heat Exchanger − Limited lifetime warranty in residential applications (twenty year transferrable), twenty year limited warranty in non−residential applications. SureLight® ignition control module − Five year limited warranty in residential applications, one year limited warranty in non−residential applications. All other covered components − Five year limited warranty in residential applications, one year limited warranty in non−residential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com NOTE − Due to Lennox’ ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. ©2003 Lennox Industries Inc. Installation and service must be performed by a qualified installer and servicing agency. FEATURES APPLICATIONS Input capacities of 66,000, 88,000, 110,000, and 132,000 Btuh (19.3, 25.8, 32.2, and 38.7 kW). Energy efficiency (AFUE) up of 94.6% in all four installation configurations. Compact cabinet for up−flow, down−flow, horizontal−left or horizontal− right applications without any internal modifications to the unit. Lennox add-on evaporator coils, high−efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Each unit factory test operated to ensure proper operation. APPROVALS Units certified by CSA International and ratings are certified by GAMA. Units tested and rated according to US DOE test procedures and FTC labeling regulations. Blower data from unit tests conducted in Lennox Laboratory air test chamber. Approved by the California Energy Commission and meet California Seasonal Efficiency requirements and California Nitrogen Oxides (NOx) Standards. ENERGY STAR® certified units are designed to use less energy, help save money on utility bills, and help protect the environment. ISO 9001 Registered Manufacturing Quality System. HEATING SYSTEM Lennox Duralok Plus® Heat Exchanger Assembly Lennox developed heat exchanger assembly consists of primary heat exchanger and secondary condenser coil assembly. Main 3-pass crimped seam design clamshell type heat exchanger. Constructed of heavy−gauge, aluminized steel. Designed for normal expansion and contraction with maximum efficiency and minimum resistance to airflow. Secondary heat exchanger condenser coil constructed of aluminum fins fitted to stainless steel tubes. Coil is factory tested for leaks. Condensate drain header box assembly located on front of coil. Compact size of complete heat exchanger assembly permits low overall design of furnace cabinet. All components mounted in a heavy−gauge steel frame. Heat exchanger assembly has been laboratory life cycle tested. Lennox Designed Header Box Header box on end of condenser coil collects flue condensate for disposal through condensate collars. Hose connects the header box drains to the condensate collars. The condensate collars are located on each side of the cabinet for easy field installation of condensate drain trap. Only one collar is used, the remainder stay plugged. Condensate drain trap is included with the unit for field installation. Lennox Designed Flue Condensate Trap Assembly Condensate trap assembly is mounted outside the conditioned air stream. Assembly can be mounted on either side of cabinet in up−flow and down−flow applications. Assembly is mounted on the bottom of the cabinet in horizontal applications. See Installation Instructions. Connection can be made with field provided 1/2 in. PVC pipe, 3/4 in. PVC coupling, or 1−1/4 in. OD x 1 in. ID vinyl tubing with hose clamp. Easy to clean and winterize. Inshot Burners Aluminized steel inshot burners provide efficient, trouble−free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. G61MPV / Page 2 Two−Stage Gas Control Valve 24 volt redundant combination two stage gas control valve combines manual shut off valve (On−Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Flame Rollout Switch Manual reset switches are factory installed on burner box. Switch provides protection from abnormal operating conditions. SureLight® Hot Surface Ignitor Tough, reliable, long−life, trouble−free performance. Tungsten heater element sandwiched between two plates of silicon nitride. Cemented to steatite block for protection against current leakage. Ignition leads constructed of nickel plated copper enclosed in high temperature Teflon insulation for dependable operation. No electrical noise. Combustion Air Inducer PSC, heavy−duty blower prepurges heat exchanger and safely vents flue products. Pressure switches prove blower operation before allowing gas valve to open. Operates only during heating cycle. Limit Control Automatic reset, primary and secondary limits are accurately located. Primary limit factory installed on vestibule panel on all units, secondary limit factory installed on blower housing. BLOWER Variable Speed Direct Drive Blower Each blower assembly statically and dynamically balanced. Change in blower speed is easily accomplished by simple DIP switch change on SureLight® Integrated Furnace Two Stage / Variable Speed Blower Control. See Blower Performance tables. Blower assembly easily removed for servicing Variable Speed Blower Motor Variable speed motor maintains specified air volume from 0 though 0.80 in. w.g. (0 through 200 Pa) static range. Motor is controlled by SureLight® Integrated Furnace Two Stage / Variable Speed Blower Control. Motor is resiliently mounted. When furnaces are used with Harmony Zone Control System, blower motor operates from predetermined minimum − maximum air volumes to satisfy zone requirements. COIL MATCH−UP All furnaces exactly match C33 and CX34 cased up−flow evaporator coils and CH33 horizontal evaporator coils with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. C33 uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See C33 coil bulletin for additional information. All furnaces exactly match CR26 cased, down−flow evaporator coils with adaptor rails, furnished with coil. FILTER (NOT FURNISHED) Filter and provisions for external mounting must be field provided. FEATURES CONTROLS SureLight® Integrated Two Stage / Variable Speed Blower Control Solid−state board contains all necessary controls and relays to operate furnace. Combustion air inducer is controlled by board. Prior to ignition, a low speed pre−purge cycle for 15 seconds is initiated. After the main burners are turned off, a post−purge cycle for 5 seconds is run. Adaptive technology of ignition control board continuously monitors and adjusts the ignitor power to operate at minimum ignitor temperature required for ignition, prolonging ignitor life. Electronic flame sensor assures safe and reliable operation. Should flame fail to ignite, flame sensor will initiate 4 re−attempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Jumper settings for single or two stage thermostat operation. Two selectable 2nd stage recognition times (10 and 15 minutes) are available on the board when the furnace is used with a single stage thermostat. When used with a two stage thermostat, furnace will only initiate second stage operation with a second stage thermostat demand. Two LED’s indicate heating status and aid in troubleshooting. Two accessory terminals furnished for additional power supply requirements for 120 volt (less than 1 amp) power humidifiers and electronic air cleaners. Control interfaces variable speed motor with thermostat and optional CCB1 humidity control. Two blower speeds − second stage heat and second stage cool (with four air volume selections for each) are selected by DIP switches on board. Heat speed can be adjusted to optimize discharge temperature. Cool speed can be adjusted to correct optional cooling capacity. See Blower Performance tables. First stage blower speed is a percentage of second stage speed. The ADJUST switch (DIP) allows normal (NORM), 10% higher (+ plus) or 10% lower ( minus) motor speed selection within HEAT and COOL speeds selected for fine tuning air volume. DELAY switch (DIP) allows one of four de−humidification profiles during cooling mode. Profile A − Motor runs at 50% for 30 seconds, then at 82% for 7−1/2 minutes, then at 100% (if needed) until demand is satisfied. Once demand is met, motor runs at 50% for 30 seconds, then ramps down to stop. Profile B − Motor runs at 82% for 7−1/2 minutes and then at 100% (if needed) until demand is satisfied. Once demand is met,motor ramps down to stop. Profile C − Motor runs at 100% until demand is satisfied. Once demand is met, motor runs at 100% for 60 seconds, then ramps down to stop. Profile D − Motor runs at 100% until demand is satisfied. Once demand is met, motor ramps down to stop. In heat mode, blower on time is fixed at 45 seconds, blower off time is adjustable from 60, 90, 120 and 180 seconds (factory setting − 90 seconds). Control has four status lights (CFM, ON/OFF, HTG BLOWER, HI/LOW) to assist in servicing. For air−conditioning applications, blower on time is 2 seconds following thermostat demand for cooling. Board controls evaporator humidity by controlling blower and compressor speed on two stage outdoor units when used with CCB1 humidity control or Lennox SignatureStat. Control is factory installed in the unit control box. 24 Volt Transformer Furnished and factory installed in control box. 40VA transformer has circuit breaker wired in series. Field Wiring Make-up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed internally or externally on either side of furnace. CABINET Low−profile, narrow width cabinet allows easy installation in up− flow, down−flow or horizontal applications. Heavy−gauge, cold rolled steel construction. Pre−painted cabinet finish. Flanges provided on supply air opening for ease of plenum connection or alignment with evaporator coil. Fully insulated cabinet with foil faced insulation on sides and back of heating compartment and mat faced insulation in blower compartment. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access door is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Return Air Entry: For bottom return−air entry, remove furnished bottom seal panel from cabinet. For side return−air entry (up−flow applications only), corners are marked on either side of cabinet for return air cut−outs. See dimension drawings. NOTE − 60C and 60D size units that require air volumes over 1800 cfm (850 L/s) must have one of the following: 1. Single side return air with transition, to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter, required to maintain proper air velocity. 2. Single side return air with optional RAB Return Air Base. 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA Down−Flow Additive Base Required for heating only units installed on combustible floors. Not required in add-on cooling applications. See Dimension Drawing. FILTERS Air Filter and Rack Kit for Horizontal Return Air (End) Applications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. Air Filter and Rack Kit for Side Return Air Applications (Not for use with RAB Return Air Base) Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. Available in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. EZ Filter Base for Bottom Return Air Applications Hinged door with thumbscrew for easy filter access. Uses standard size filters (field provided). RAB RETURN AIR BASE For 60C and 60D models with air volumes over 1800 cfm (850 L/s) in up−flow applications when only one side return is required. Cabinet is pre−painted steel to match the furnace. See Dimension Drawing. G61MPV / Page 3 OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA TERMINATION KITS Facilitates installation of combustion air intake pipe and flue exhaust pipe. Refer to venting table in this bulletin to determine pipe size needed and proper termination kit required. See Specifications table and dimension drawings. Termination Kit − Concentric − Direct Vent Applications Only 1−1/2, 2, or 3 inch (38, 51, or 76 mm) kit contains concentric termination assembly, mounting clamp, roof flashing, reducer bushing and 45 degree elbow. Kit requires single hole penetration of roof or wall for installation. CSA certified. Termination Kit − Roof − Direct or Non−Direct Vent 2 or 3 inch (51 or 76 mm) kit contains two neoprene rubber roof flashings. Termination Kits − Wall Assembly Close Couple − Direct Vent Applications Only 2 or 3 inch (51 or 76 mm) kit consists of close-couple, side-byside PVC piping with galvanized steel wall cover plate for sealing and isolating piping penetration of the wall. Piping spacing and length is sized for proper wall installations. CSA certified. Close Couple WTK − Direct Vent Applications Only 2 or 3 inch (51 or 76 mm) kit contains one insulated faceplate, one insulated exhaust pipe, elbow and fittings. Wall Ring − Direct or Non−Direct Vent 2 inch (51 mm) kit contains 2 stainless steel outside seal caps, 2 galvanized steel inside seal caps, 4 seal rings for the caps and 18 inch (457 mm) insulation sleeve for sealing and isolating intake and exhaust piping penetration of wall. Maintain a maximum of 6 inches (152 mm) between the inlet and outlet openings in the installation of the pipes. Condensate Drain Heat Cable Kits Self-limiting wattage heat cable prevents condensate drain from freezing in unconditioned areas. Available in 6, 24 or 50 ft. (1.8, 7.3, or 15.2 m) lengths. Heat Cable Tape: 66 ft. (20 m) length, 1/2 in. (13 mm) wide fiberglass. 60 ft. (18 m) length, 2 in. (51 mm) wide aluminum foil. Gas Conversion Kits LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/Propane. Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of (2) 1 x 1-1/2 x 32-5/8 in. (25 x 38 x 829 mm) and (2) 1 x 3 x 53-7/8 in. (25 x 76 x 1368 mm) painted, heavy−gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. SignatureStatt Home Comfort Controller Combination temperature and humidity control in cooling mode. 2 Heat/2 Cool Auto−changeover Easy−to−use, menu driven thermostat with a back−lit, dot− matrix LCD screen. Remote outdoor sensor (furnished) allows the thermostat to display outdoor temperature and adjust indoor dewpoint temperature for precision humidity control in cooling mode. See the SignatureStat Engineering Handbook bulletin in the Controls section for more information. HIGH ALTITUDE INFORMATION Pressure regulator adjustment may be required depending on altitude. See below for proper pressure regulator setting. Manifold Pressure (Outlet) in. w.g. (kPa) Fuel Natural HIGH ALTITUDE KITS High Altitude Orifice Kit − Natural Gas Only Required for all natural gas models for proper unit operation at altitudes of 7501 to 10,000 feet (2286 to 3048 m). High Altitude Pressure Switch Kit Required on certain units for proper unit operation on installations above 4,500 ft. (1372 m). Order two per unit. 3 LPG Propane Altitude − ft. (m) 0−4500 (0−1372) High Fire Low Fire 3.5 (0.87) 1.7 (0.42) 4501−7500 (1373−2286) 2 3.5 7501−10,000 (2287−3048) 1, 2 3.5 0−4500 (0−1372) (0.87) (0.87) 10.0 (2.49) 1.7 (0.42) 1.7 (0.42) 4.9 (1.22) 4501−7500 (1373−2286) 2 10.0 (2.49) 4.9 (1.22) 7501−10,000 (2287−3048) 2 10.0 (2.49) 4.9 (1.22) 1 High 2 High Altitude Orifice Kit required, see Specifications table for order number. Altitude Pressure Switch Kits required for −070, −110, −135 models, see Specifications table for order number. 3 LPG/Propane conversion kit required, see Specifications table for order number. EXHAUST PIPE VENTING TABLE Model No. Altitude 0 − 4,500 , ft. (0 − 1372 m)) 4,501 , − 10,000 , ft. (1372 − 3048 m)) 2 3 2 3 in. in. in. in. diameter diameter diameter diameter G61MPV−36B−070 55 ft. (16.8 m) 70 ft. (21.3 m) 55 ft. (16.8 m) 70 ft. (21.3 m) Maximum Equivalent Vent Length 1 G61MPV−60C−110 G61MPV−36C−090 G61MPV−60C−090 25 ft. (7.6 m) 70 ft. (21.3 m) 25 ft. (7.6 m) 70 ft. (21.3 m) 15 ft. (4.6 m) 70 ft. (21.3 m) 15 ft. (4.6 m) 70 ft. (21.3 m) G61MPV−60D−135 not allowed ft. (16.8 m) not allowed 2, 3 40 ft. (12.2 m) 3 55 NOTE − Minimum Equivalent Vent Pipe length is 15 feet (4.6 m). 1 110 models installed in up−flow or down−flow applications must have the supplied 90° street ell installed directly into the unit flue collar. The street ell must be included in the elbow count. 2 Must have 3 in. to 2 in. reducing elbow (supplied) installed directly into the flue collar when installed in up−flow or down−flow configurations. Reducing ell must NOT be included in elbow count. 3 90 elbows must be limited to 3 in. sweep elbows. VENTING NOTES  One 90elbow is equivalent to 5 feet (1.5 m) of straight vent pipe. Two 45 elbows are equal to one 90 elbow. One 45 elbow is equivalent to 2.5 feet (762 mm) of straight vent pipe. One foot (305 mm) length of 2 in. (51 mm) diameter pipe is equivalent to 8 feet (2.4 m) of 3 in. (76 mm) diameter pipe. Wall and roof termination (non−concentric) exhaust pipe must terminate with reducer to improve exhaust velocity away from intake piping. 070 − 2 or 3 in. − terminate with 1−1/2 in. pipe 090 and 110 − 2 in. − no change required 090 and 110 − 3 in. − terminate with 2 in. pipe 135 − 3 in. − terminate with 2 in. pipe G61MPV / Page 4 SPECIFICATIONS Gas H ti Heating Performance ModelNo. Input− Btuh (kW) High g Fire G61MPV−36B−070 66,000 (19.3) Output− Btuh (kW) 61,000 (17.9) 79,000 (23.1) 45 − 75 (25 − 42) 70 − 100 (39 − 56) Input− Btuh (kW) 45,000 (13.2) 60,000 (17.6) Output− Btuh (kW) 43,000 (12.6) 57,000 (16.7) Temperature rise range − F (C) Low Fire Temperature rise range − F (C) 25 − 55 (14 − 31) 35 − 65 (19 − 36) 1 AFUE 94.1% 94.3% California Seasonal Efficiency 89.6% 91.2% Highstatic(CSA)− in.w.g. (Pa) 0.8 0.8 2 2 2 Connections i in. Intake Pipe (PVC) 2 Exhaust Pipe (PVC) 2 2 Condensate Drain Trap (PVC pipe) − i.d. 1/2 1/2 with field supplied (PVC coupling) − o.d. 3/4 3/4 1−1/4 x 1 1−1/4 x 1 hose with hose clamp − i.d. x o.d. GaspipesizeIPS Indoor Bl Blower G61MPV−36C−090 88,000 (25.8) Wheel nominal diameter x width −in. (mm) Motoroutput − hp (W) Tons(kW) ofadd-oncooling ShippingData lbs. (kg) − 1 package Electricalcharacteristics 1/2 1/2 10 x 8 (254 x 203) 10 x 10 (254 x 254) 1/2 (373) 1/2 (373) 2 − 3.5 (7 − 12.3) 2 − 3.5 (7 − 12.3) 151 (68) 170 (77) 120 volts − 60 hertz − 1 phase (less than 12 amps) OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA 3, 4 Air Filter and Rack Kit Size of filter Horizontal (end) Side Return Condensate Drain Heat C bl Cable Heat Cable Tape p 4 EZ Filter Base 87L96 − 18 x 25 x 1 in. (457 x 635 x 25 mm) 87L97 − 20 x 25 x 1 in. (508 x 635 x 25 mm) Single 44J22 or Ten Pack 66K63 − 16 x 25 x 1 in. (406 x 635 x 25 mm) 6 ft. (1.8 m) 26K68 26K68 24 ft. (7.3 m) 26K69 26K69 50 ft. (15.2 m) 26K70 26K70 Fiberglass − 1/2 in. (38 mm) x 66 ft. (20 m) 39G04 39G04 Aluminum foil − 2 in. (25 mm) x 60 ft. (18 m) Catalog Number − Ship. Weight − lbs. (kg) Dimensions − H x W x D − in. (mm) Size of field provided filter − in. (mm) 39G03 39G03 73P56 − 7 (3) 73P57 − 8 (4) 4 x 17−5/8 x 28−5/8 (102 x 448 x 727) 4 x 21−5/8 x 28−5/8 (102 x 549 x 727) 16 x 25 x 1 (406 x 635 x 25) 20 x 25 x 1 (508 x 635 x 25) Down−Flow Additive Base 11M60 11M61 5 High Altitude Orifice Kit − Natural Gas 59M16 59M16 5 High Altitude Pressure Switch Kit − Order two each 56M23 −−− 56J18 − 18 (8) 56J18 − 18 (8) 59M13 59M13 59M14 59M14 59M87 59M87 SignatureStatt Home Comfort Controller 51M27 51M27 7 Termination 60G77 −−− −−− 33K97 Horizontal Support Frame Kit − Ship. Weight − lbs. (kg) LPG/Propane p Kit 0−7500 ft. (0−2286 m) 7501−10,000 ft. (2286−3048 m) 6 LPG/Propane to Natural Gas Kit Concentric Kits Kit Direct Vent Applications Only 1−1/2 inch (38 mm) 2 inch (51 mm) 3 inch (76 mm) −−− 60L46 22G44 −−− 3 inch (76 mm) 44J40 44J40 Close Couple WTK − 2 inch (51 mm) 30G28 −−− 15F75 15F75 Wall Close Couple − 2 inch (51 mm) 7, 8 Termination Roof 2 inch (51 mm) Kits Direct Vent or Non−Direct Vent 3 inch (76 mm) 44J41 44J41 Wall Wall Ring Kit 2 inch (51 mm) 15F74 15F74 NOTE − Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. 2 Determine from venting tables proper exhaust pipe size and termination kit required. 3 Cleanable polyurethane frame type filter. 4 Not for use with RAB Return Air Base or with 60C and 60D size units with air flow requirements of 1800 cfm (850 L/s) or greater. See Blower Performance tables for additional information. 5 Required for proper operation at altitudes from 7501 to 10,000 ft. (2286 to 3048 m). 6 For applications from 7501 to 10,000 ft. (2286 to 3048 m), a High Altitude Orifice Kit will need to be ordered separately. 7 See Installation Instructions for specific venting information. 8 Kits contain enough parts for two, non−direct vent installations. G61MPV / Page 5 SPECIFICATIONS Gas H ti Heating Performance ModelNo. Input− Btuh (kW) High g Fire Output− Btuh (kW) G61MPV−60D−135 132,000 (38.7) 82,000 (24.0) 99,000 (29.0) 122,000 (35.7) 50 − 80 (28 − 44) 65 − 95 (36 − 53) Input− Btuh (kW) 60,000 (17.6) 75,000 (22.0) 90,000 (26.4) Output− Btuh (kW) 55,000 (16.1) 72,000 (21.1) 87,000 (25.5) Temperature rise range − F (C) 20 − 50 (11 − 28) 30 − 60 (17 − 33) 40 − 70 (22 − 39) 1 AFUE 94.6% 94.3% 94.6% California Seasonal Efficiency 89.0% 90.1% 91.3% Highstatic(CSA)− in.w.g. (Pa) 0.8 0.8 0.8 2 Intake Pipe (PVC) 2 2 3 2 Exhaust Pipe (PVC) 2 2 3 Condensate Drain Trap (PVC pipe) − i.d. 1/2 1/2 1/2 with field supplied (PVC coupling) − o.d. 3/4 3/4 3/4 1−1/4 x 1 1−1/4 x 1 1−1/4 x 1 1/2 1/2 1/2 11−1/2 x 10 (292 x 229) 11−1/2 x 10 (292 x 229) 11−1/2 x 10 (292 x 229) Connections i in. hose with hose clamp − i.d. x o.d. GaspipesizeIPS Indoor Bl Blower G61MPV−60C−110 110,000 (32.2) 40 − 70 (22 − 39) Temperature rise range − F (C) Low Fire G61MPV−60C−090 88,000 (25.8) Wheelnominaldiameter xwidth −in. (mm) Motoroutput − hp (W) Tons(kW) ofadd-oncooling ShippingData lbs. (kg) − 1 package 1 (746) 1 (746) 1 (746) 3.5 − 5 (12.3 − 17.5) 3.5 − 5 (12.3 − 17.5) 3.5 − 5 (12.3 − 17.5) 180 (82) 188 (85) 207 (94) Electricalcharacteristics 120 volts − 60 hertz − 1 phase (less than 12 amps) OPTIONAL ACCESSORIES − MUST BE ORDERED EXTRA 3, 4 Air Filter and Rack Kit − Size of filter Horizontal (end) Side Return Condensate Drain Heat C bl Cable Heat Cable Tape p 4 EZ Filter Base 87L97 − 20 x 25 x 1 in. (508 x 635 x 25 mm) 87L97 − 20 x 25 x 1 in. (508 x 635 x 25 mm) 87L98 − 25 x 25 x 1 in. (635 x 635 x 25 mm) Single 44J22 or Ten Pack (66K63) − 16 x 25 x 1 in. (406 x 635 x 25 mm) 6 ft. (1.8 m) 26K68 26K68 26K68 24 ft. (7.3 m) 26K69 26K69 26K69 50 ft. (15.2 m) 26K70 26K70 26K70 39G04 39G04 39G04 Fiberglass − 1/2 in. (38 mm) x 66 ft. (20 m) 39G03 39G03 39G03 73P57 − 8 (4) 73P58 − 10 lbs. (5 kg) 73P58 − 10 lbs. (5 kg) Dimensions − H x W x D − in. (mm) 4 x 21−5/8 x 28−5/8 (102 x 549 x 727) 4 x 24−5/8 x 28−5/8 (102 x 625 x 727) 4 x 24−5/8 x 28−5/8 (102 x 625 x 727) Size of field provided filter − in. (mm) 20 x 25 x 1 (508 x 635 x 25) 24 x 24 x 1 (610 x 610 x 25) 24 x 24 x 1 (610 x 610 x 25) Aluminum foil − 2 in. (25 mm) x 60 ft. (18 m) Catalog Number − Shipping Weight Down−Flow Additive Base 11M61 11M61 11M62 5 High Altitude Orifice Kit − Natural Gas Only 59M16 59M16 59M16 6 High Altitude Pressure Switch Kit − Order two each −−− 56M23 56M93 56J18 − 18 (8) 56J18 − 18 (8) 56J18 − 18 (8) 0−7500 ft. (0−2286 m) 59M13 59M13 59M13 7501−10,000ft. (2286−3048m) 59M14 59M14 59M14 59M87 59M87 59M87 RAB60C (12M71) RAB60C (12M71) RAB60D (12M72) 51M27 Horizontal Support Frame Kit − Ship. Weight − lbs. (kg) LPG/Propane Kit 7 LPG/Propane to Natural Gas Kit RAB Return Air Base SignatureStatt Home Comfort Controller 8 Termination Kits Direct Vent Applications Only Concentric 51M27 51M27 2 inch (51 mm) 33K97 33K97 −−− 3 inch (76 mm) 60L46 60L46 60L46 44J40 Wall Close−Couple 3 inch (76 mm) 44J40 44J40 Kits Roof Di t V Direct Ventt or N Non− Direct Vent Wall 2 inch (51 mm) 15F75 15F75 −−− 3 inch (76 mm) 44J41 44J41 44J41 Ring Kit 2 inch (51 mm) 15F74 15F74 10 15F74 8, 9 Termination NOTE − Filters and provisions for mounting are not furnished and must be field provided. 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. 2 Determine from venting tables proper exhaust pipe size and termination kit required. 3 Cleanable polyurethane frame type filter. 4 Not for use with RAB Return Air Base or with 60C and 60D size units with air flow requirements of 1800 cfm (850 L/s) or greater. See Blower Performance tables for additional information. 5 Required for proper operation at altitudes from 7501 to 10,000 ft. (2286 to 3048 m). 6 Required for proper operation at altitudes from 4501 to 10,000 ft. (1370 to 3048 m). 7 For applications from 7501 to 10,000 ft. (2286 to 3048 m), a High Altitude Orifice Kit will need to be ordered separately. 8 See Installation Instructions for specific venting information. 9 Kits contain enough parts for two, non−direct vent installations. 10 Non−direct vent applications only. G61MPV / Page 6 FILTER AIR RESISTANCE INSTALLATION CLEARANCES Sides Rear Top/Plenum Front Front (service/alcove) Floor For 1 Inch (25 mm) Cleanable Filter (Field Provided) cfm 0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 L/s 0 95 190 285 380 470 565 660 755 850 945 1040 1130 1225 in. w.g. 0.00 0.01 0.03 0.04 0.06 0.09 0.12 0.15 0.19 0.23 0.27 0.33 0.38 0.44 Pa 0 0 5 10 15 20 30 35 45 55 65 80 95 110 10 inches (0 mm) 0 inches (0 mm) 1 inch (25 mm) 0 inches (0 mm) 24 inches (610 mm) 2 Combustible NOTE − Air for combustion and supply air ventilation must conform to the methods outlined in American National Standard (ANSI-Z223.1) National Fuel Gas Code or National Standard of Canada CAN/CGA-149.1, & CAN/CGA-149.2 Installation Code for Gas Burning Appliances". NOTE−In the U.S. flue sizing must conform to the methods outlined in current GAMA/A.G.A. venting tables, American National Standard (ANSI-Z223.1) National Fuel Gas Code or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/ CGA-149.1 and .2. 1 Allow proper clearances to accommodate condensate trap and vent pipe installation. 2 Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring. INSTALLATION CONFIGURATIONS UP−FLOW DOWN−FLOW HORIZONTAL − RIGHT AIR FLOW VENT PIPING VENT PIPING HEAT EXCHANGER BLOWER BLOWER HEAT EXCHANGER AIR FLOW CONDENSATE DRAIN VENT PIPING HORIZONTAL − LEFT CONDENSATE DRAIN BLOWER VENT PIPING HEAT EXCHANGER HEAT EXCHANGER CONDENSATE DRAIN AIR FLOW NOTE − On up−flow and down−flow configurations, the vent piping and condensate drain can be moved to the other side of the unit. Vent piping and drain must be installed on the same side of the unit with each other. On horizontal installations the drain must be located at the bottom and the vent piping at the top. BLOWER AIR FLOW CONDENSATE DRAIN G61MPV / Page 7 DIMENSIONS − INCHES (MM) UP−FLOW POSITION SHOWN 1 NOTE − 60C and 60D size units that require air volumes over 1800 cfm (850 L/s) must have one of the following: a. Single side return air with transition, to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) air filter. Required to maintain proper air velocity. b. Single side return air with optional RAB Return Air Base c. Bottom return air. d. Return air from both sides. e. Bottom and one side return air. SUPPLY AIR OPENING See Blower Performance Tables for additional information. 2 Optional External Side Return Air Filter Kit (Up−Flow Only) is not for use with the optional RAB Return Air Base. OPTIONAL EXTERNAL SIDE RETURN AIR FILTER KIT (Either Side) A B 23-3/4 (603) 2 9/16 (14) 25 (635) TOP VIEW 28−1/2 (724) 5−1/2 (140) 6−1/2 11−5/8 (295) (165) Right 9−3/4 (248) 4−1/8 (103) Left 2 OPTIONAL EXTERNAL SIDE RETURN AIR FILTER KIT (Either Side) 40 (1016) 6−1/2 (165) COMBUSTION AIR INTAKE (Either Side) 3−1/8 (79) EXHAUST AIR OUTLET (Either Side) 6−3/4 (171) GAS PIPING INLET (Either Side) CONDENSATE TRAP CONNECTION (Either Side) 4−7/8 (124) Right 2−1/4 (57) Left ELECTRICAL INLET (Either Side) 2−1/2 (64) 14−3/4 (375) 18-3/4 (476) 16 (406) 9/16 (14) 19−7/16 (378) 23 (584) 4 (102) 14 (356) 1 OPTIONAL RETURN CUTOUT (Either Side) Up−Flow Only AIR FLOW 1−15/16 (49) 5/8 (16) C 3/4 (19) 1 23−1/2 (597) 3/4 (19) 4−1/4 (108) Bottom Return Air Opening 1 FRONT VIEW Model No No. Bottom Return Air Opening SIDE VIEW A B C in. mm in. mm in. mm G61MPV−36B−070 17−1/2 446 16−3/8 416 16 406 G61MPV−36C−090 G61MPV−60C−090 G61MPV−60C−110 21 533 19−7/8 454 19−1/2 495 G61MPV−60D−135 24−1/2 622 23−3/8 546 23 584 G61MPV / Page 8 DIMENSIONS − INCHES (MM) − FURNACE/COIL COMBINATIONS UP−FLOW POSITION DOWN−FLOW POSITION A 40 (1016) B B HORIZONTAL 40 (1016) B A 40 (1016) A Model No No. A in. B mm in. mm Model No No. A B in. mm in. mm Up−Flow Uncased C33−24B−2 13−7/8 352 53−7/8 1368 CH33−36B−2F 26−1/2 673 66−1/2 1689 C33−30B−2 17−3/4 451 57−3/4 1467 CH33−36C−2F 26−1/2 673 66−1/2 1689 C33−48B−2 22−1/8 562 62−1/8 1578 C33−36B−2 21−7/8 556 61−7/8 1572 CH33−42B−2F 26−1/2 673 66−1/2 1689 C33−36C−2 21−1/4 540 61−1/4 1556 CH33−44/48B−2F 31−1/2 800 71−1/2 1816 C33−38B−2 22 559 CH33−48C−2F 26−1/2 673 66−1/2 1689 31−1/2 800 71−1/2 1816 Horizontal Cased 62 1575 C33−42B−2 21−7/8 556 61−7/8 1572 CH33−50/60C−2F C33−44C−2, C33−48C−2 21−1/2 546 61−1/2 1562 CH33−60D−2F 26−1/2 673 66−1/2 1689 C33−50/60C−2, C33−60D−2 24−3/4 629 64−3/4 1645 CH33−62D−2F 31−1/2 800 71−1/2 1816 C33−62D−2 28−3/4 730 68−3/4 1746 Down−Flow Cased Up−Flow Cased C33−24B−2F, CX34−18/24B−6F CR26−18N−F 12−3/4 324 52−3/4 1340 16−1/2 419 56−1/2 1435 CR26−30N−F 12−3/4 324 52−3/4 1340 C33−30B−2F, CX34−30B−6F 20−1/2 521 60−1/2 1537 CR26−36N−F 15−3/8 391 55−3/8 1407 CR26−36W−F 15−3/8 391 55−3/8 1407 CR26−48N−F 19−1/8 486 59−1/8 1502 CR26−48W−F 19−1/8 486 59−1/8 1502 CR26−60N−F 22−7/8 581 62−7/8 1597 CR26−60W−F 22−7/8 581 62−7/8 1597 C33−36B−2F, C33−36C−2F, C33−38B−2F, C33−42B−2F, C33−44C−2F, C33−48B−2F, C33−48C−2F, 24−1/2 CX34−36B−6F, CX34−36C−6F, CX34−38B−6F, CX34−42B−6F, CX34−44/48C−6F, CX34−44/48B−6F 622 C33−50/60C−2F, CX34−50/60C−6F 27−1/2 699 67−1/2 1715 C33−60D−2F, CX34−60D−6F 25−1/2 648 65−1/2 1664 C33−62D−2F, CX34−62D−6F 29−1/2 749 69−1/2 1765 64−1/2 1638 G61MPV / Page 9 OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) RAB RETURN AIR BASE (Up−Flow Applications Only) For use with 60C and 60D size furnaces only OPTIONAL RETURN AIR BASE 1 4 (102) 23 Overall (584) 14 (356) *Unit Opening 1 SIDE RETURN AIR OPENINGS (Either Side) AIR FLOW 1 3−1/4 (83) 18−1/2 (470) Overall Base Opening 20−1/2 (521) 21 (533) RAB60C 7/8 (22) 24−1/2 (622) RAB60D 3/4 (19) 27−5/8 (702) SIDE VIEW FRONT VIEW 1 NOTE−Both return air openings must be covered by a single plenum. Overall opening dimensions: 23 (584) W X 18−1/2 (470) H. Optional Side Return Air Filter Kits are not for use with RAB Return Air Base. DOWN-FLOW ADDITIVE FLOOR BASE 1-1/2 (38) SUPPLY AIR OPENING DOWN FLOW FURNACE 19-13/16 (503) 21-13/16 (554) 27-1/4 (692) 1-1/2 (38) B 1-1/2 (38) Front Of Furnace 1-1/2 (38) A TOP VIEW SIDE VIEW DOWN-FLOW ADDITIVE FLOOR BASE FLOOR OPENING 22 (559) C Model No No. G61MPV−36B−070 G61MPV−36C−090 G61MPV−60C−090 G61MPV−60C−110 G61MPV−60D−135 G61MPV / Page 10 A B C in. 19−9/16 mm 497 in. 16−9/16 mm 421 in. 18−3/4 mm 476 23−1/16 586 20−1/16 510 22−1/4 565 26−9/16 675 23−9/16 598 25−3/4 654 OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) HORIZONTAL FILTER KIT 1-1/4 (32) 24−3/4 (629) 5/8 (16) 5/8 (16) B A RETURN AIR OPENING Catalog Number AIR FLOW A B inch mm inch mm 87L96 18 457 16−3/4 425 87L97 21 533 18−3/4 476 87L98 25 635 23−3/4 603 23−1/2 (597) 5/8 (16) AIR FILTER (Furnished) 5/8 (16) FRONT VIEW SIDE VIEW CONCENTRIC ROOF TERMINATION APPLICATIONS CONCENTRIC WALL TERMINATION APPLICATIONS 10-1/2 (267) OUTSIDE WALL FLASHING 12 (305) INTAKE AIR EXHAUST AIR EXHAUST AIR Minimum Above Average Snow Accumulation SHEET METAL STRAP INTAKE AIR INTAKE AIR (Clamp and sheet metal strap must be field installed to support the weight of the termination kit.) 12 (305) Minimum Above Grade ÉÉÉÉÉÉÉÉ CLAMP GRADE 60G77  1−1/2 inch (38 mm) 33K97  2 inch (51 mm) See Installation Instructions for specific usage. 60L46  3 inch (76 mm) See Installation Instructions for specific usage. 2 x 1-1/2 in. (51 x 38 mm) 60G77 3 x 2 in. (76 x 51 mm) 33K97 REDUCER BUSHING (Furnished) 46−3/4 (1187) 37 (940) INTAKE AIR 4−1/2 (114) 3 (76) INTAKE AIR ELBOW (Furnished) CLAMP (Furnished) 6−1/2 (165) TERMINATION ASSEMBLY (Furnished) EXHAUST AIR INTAKE AIR ELBOW (Field Supplied) TERMINATION ASSEMBLY (Furnished) EXHAUST AIR G61MPV / Page 11 OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) WALL ASSEMBLY TERMINATION KIT − RING KIT 15F74 − 2 inch (51 mm) See Installation Instructions for specific usage. NON−DIRECT VENT APPLICATION NOTE  EXHAUST PIPE SHOWN DIRECT VENT APPLICATION NOTE − 12 in. (305 mm) minimum height above average snow accumulation. Kit Contains Enough Parts For Two Installations NOTE  12 in. (305 mm) minimum height above average snow accumulation. 12 in. (305 mm) maximum without support 12 in. (305 mm) maximum without support 6 in. (152 mm) maximum 8 in. (203 mm) minimum DIRECT VENT APPLICATIONS WALL TERMINATION KITS (CLOSE-COUPLE) 22G44 − 2 inch (51 mm) 44J40 − 3 inch (76 mm) See Installation Instructions for specific usage. If Intake and Exhaust Pipe is less than 12 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. EXHAUST AIR 12 (305) INSULATION (Not Furnished) INTAKE AIR INTAKE AIR EXHAUST AIR 5 (127) 2 (51) 5-1/2 (140) ÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉ GRADE G61MPV / Page 12 12 (305) 12 (305) Minimum 12 (305) ABOVE GRADE ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ GRADE OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM) DIRECT VENT APPLICATIONS WTK WALL ASSEMBLY TERMINATION KIT WITH FIELD FABRICATION ABOVE GRADE EXTENDED CLEARANCE 30G28 − 2 inch (51 mm) See Installation Instructions for specific usage. If Intake and Exhaust Pipe is less than 12 in. (305 mm) above snow accumulation or other obstructions, field fabricated piping must be installed. EXHAUST AIR 12 (305) INSULATION (Not Furnished) INTAKE AIR EXHAUST AIR INTAKE AIR 5 (127) 8 (203) Minimum 5-1/2 (140) ÉÉÉÉÉÉÉÉÉÉÉÉ GRADE 12 (305) Maximum 12 (305) Minimum ABOVE GRADE ÉÉÉÉÉÉÉÉÉÉÉÉÉÉ GRADE BLOWER DATA G61MPV−36B−070 PERFORMANCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Speed Switch Positions ADJUST" Second Stage HEAT" Speed Switch 12 1 3 4 1 Positions cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 915 430 1315 620 1320 620 1370 645 1055 495 1 NORM 830 390 960 455 1190 560 1240 585 935 440  735 345 845 400 1050 495 1085 510 835 395 First Stage HEAT" Speed ADJUST" 12 1 3 4 1 Switch P iti Positions cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 825 390 965 455 1195 565 1245 585 690 325 1 NORM 755 355 865 410 1070 505 1115 525 635 300 695 325 780 370 935 440 985 465 600 285  Second Stage COOL" Speed 2 3 cfm L/s cfm L/s 1225 580 1315 620 1095 515 1185 560 960 455 1050 495 First Stage COOL" Speed 2 3 cfm L/s cfm L/s 770 365 820 386 715 335 750 355 645 305 680 320 14 cfm 1435 1300 1145 L/s 675 615 540 14 cfm 890 810 725 L/s 420 380 340 G61MPV−36C−090 PERFORMANCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Speed Switch Positions ADJUST" Second Stage HEAT" Speed Switch 12 1 3 4 1 Positions cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + N/A N/A 1015 480 1235 580 1290 610 1010 475 1 NORM N/A N/A 925 435 1120 530 1170 550 920 435  N/A N/A 830 390 1010 475 1055 495 825 390 First Stage HEAT" Speed ADJUST" ADJUST 12 1 3 4 1 Switch P iti Positions L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm + N/A N/A 945 445 1130 535 1175 555 765 360 1 NORM N/A N/A 860 405 1030 485 1070 505 695 325  N/A N/A 770 365 925 435 960 455 625 295 Second Stage COOL" Speed 2 3 cfm L/s cfm L/s 1150 540 1230 580 1045 495 1120 530 940 445 1010 475 First Stage COOL" Speed 2 3 cfm L/s cfm L/s 845 400 895 420 770 365 810 380 695 325 730 345 14 cfm 1355 1230 1110 L/s 640 580 525 14 cfm 940 855 770 L/s 445 405 360 1 Factory default jumper setting. The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 91% of the same second stage HEAT speed position. First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s). Lennox Harmony zone control applications − Minimum blower heating speed is approximately 75% of the second stage HEAT speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. G61MPV / Page 13 BLOWER DATA G61MPV−60C−090 PERFORMANCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side. Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 1480 700 1685 795 1870 880 2075 980 1580 745 1715 810 1925 910 2155 1015 1 NORM 1345 635 1525 720 1725 815 1890 890 1445 680 1560 735 1750 825 1955 920  1195 565 1355 640 1515 715 1695 800 1270 600 1380 650 1570 740 1760 830 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 cfm L/s 2 cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1360 640 1520 715 1705 805 1900 895 1100 520 1180 555 1340 630 1520 715 1 NORM 1220 575 1395 660 1560 735 1720 810 1000 470 1070 505 1210 570 1360 640  1100 520 1240 585 1410 665 1535 725 885 415 965 455 1090 515 1210 570 Single Side Return Air Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter. Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 1 2 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1440 680 1630 770 1810 855 2015 950 1585 745 1665 785 1870 880 2100 990 1 NORM 1315 620 1490 705 1675 790 1845 870 1400 660 1565 740 1715 810 1920 905  1170 550 1315 620 1525 720 1650 780 1245 585 1345 635 1600 755 1710 805 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s 1315 620 1555 735 1740 820 1850 875 1090 515 1155 545 1315 620 1480 700 1 NORM 1200 565 1360 640 1565 740 1755 830 990 465 1055 495 1185 560 1370 645  1080 510 1205 570 1360 640 1575 745 870 410 935 440 1070 505 1195 565 + Side Return Air with Optional RAB Return Air Base Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 1455 685 1640 775 1865 880 2070 975 1565 740 1675 790 1915 905 2135 1005 1 NORM 1320 620 1490 705 1695 800 1880 885 1420 670 1520 715 1740 820 1940 915  1190 560 1340 630 1530 720 1690 795 1280 605 1370 645 1570 740 1745 825 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 2 cfm L/s cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1325 625 1510 710 1695 800 1870 880 1085 510 1165 550 1310 620 1465 690 1 NORM 1205 570 1375 650 1540 725 1700 800 985 465 1060 500 1190 560 1335 630  1085 510 1235 580 1385 655 1530 720 890 420 955 450 1070 505 1200 565 1 Factory default jumper setting. The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 91% of the same second stage HEAT speed position. First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s). Lennox Harmony zone control applications − Minimum blower heating speed is approximately 75% of the second stage HEAT speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. N/A − HEAT" speed, position 1 cannot be used with this model. G61MPV / Page 14 Blower Data G61MPV−60C−110 PERFORMANCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side. Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s 1520 715 1705 805 1895 895 2105 995 1610 760 1725 815 1940 915 2170 1025 1 NORM 1365 645 1545 730 1735 820 1895 895 1460 690 1575 745 1765 830 1970 930  1225 580 1390 655 1570 740 1730 815 1300 615 1400 660 1600 755 1770 835 + ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 2 cfm L/s cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1380 650 1575 745 1755 830 1945 915 1090 515 1165 550 1320 620 1490 705 1 NORM 1240 585 1435 915 1605 755 1780 840 990 465 1060 500 1200 565 1355 640  1115 525 1250 590 1425 670 1590 750 890 420 955 450 1080 510 1220 575 Single Side Return Air Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter. Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 1 2 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1475 695 1650 780 1805 850 1995 940 1575 745 1690 795 1880 885 2110 995 1 NORM 1335 630 1510 710 1695 800 1830 865 1420 670 1535 725 1715 810 1910 900  1170 550 1330 625 1490 7605 1630 770 1270 600 1365 645 1575 745 1735 820 ADJUST" Switch Positions + First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s 1345 635 1510 710 1665 785 1845 870 1060 500 1135 535 1300 615 1420 670 1 NORM 1210 70 1400 660 1565 740 1710 805 965 455 1030 485 1180 555 1290 610  1085 510 1230 580 1405 665 1535 725 870 410 930 440 1060 500 1160 545 Side Return Air with Optional RAB Return Air Base Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 cfm L/s 2 cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1460 670 1650 780 1835 865 2050 965 1560 735 1660 785 1905 900 2125 1000 1 NORM 1330 625 1510 710 1675 790 1855 875 1420 670 1510 710 1730 815 1930 910  1175 555 1335 630 1495 705 1655 780 1275 600 1360 640 1555 735 1740 820 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 1340 630 1530 720 1700 800 1875 885 1080 510 1165 550 1315 620 1475 695 1 NORM 1205 570 1380 650 1550 730 1705 805 980 460 1055 495 1195 565 1340 630  1095 515 1215 575 1380 650 1525 720 885 415 950 450 1080 510 1205 570 1 Factory default jumper setting. The effect of static pressure is included in air volumes shown. First stage HEAT is approximately 91% of the same second stage HEAT speed position. First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s). Lennox Harmony zone control applications − Minimum blower heating speed is approximately 75% of the second stage HEAT speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. G61MPV / Page 15 BLOWER DATA G61MPV−60D−135 PERFORMANCE 0 through 0.80 in. w.g. (0 Through 200 Pa) External Static Pressure Range Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side. Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 1485 700 1690 795 1905 900 2105 995 1585 745 1725 815 1955 920 2185 1030 1 NORM 1345 635 1535 725 1735 820 1915 905 1435 675 1570 740 1780 840 1990 940  N/A N/A 1370 645 1560 735 1720 810 1290 610 1405 665 1600 755 1780 840 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 2 cfm L/s cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1340 630 1525 720 1730 815 1925 910 1095 515 1180 555 1335 630 1495 705 1 NORM 1215 575 1380 650 1570 740 1750 825 995 470 1075 505 1205 570 1345 635  N/A N/A 1235 580 1410 665 1575 745 890 420 960 455 1085 510 1205 570 Single Side Return Air Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. (508 x 635 x 25 mm) cleanable air filter in order to maintain proper air velocity across the filter. Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 cfm L/s 2 cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1420 670 1585 745 1780 840 1965 925 1515 715 1610 760 1825 860 2040 960 1 NORM 1290 610 1440 680 1615 760 1785 840 1380 650 1465 690 1660 785 1855 875  N/A N/A 1295 610 1455 685 1605 755 1240 585 1315 620 1495 705 1670 790 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 1285 605 1460 690 1645 775 1810 855 1045 495 1130 535 1275 600 1400 660 1 NORM 1170 550 1325 625 1495 705 1645 775 950 450 1030 485 1155 545 1270 600  N/A N/A 1195 565 1345 635 1480 700 855 405 925 435 1040 490 1145 540 Side Return Air with Optional RAB Return Air Base Speed Switch Positions ADJUST" Switch Positions Second Stage HEAT" Speed 12 1 Second Stage COOL" Speed 3 4 cfm L/s cfm L/s cfm L/s 1 cfm L/s 2 cfm L/s 14 3 cfm L/s cfm L/s cfm L/s + 1440 680 1600 755 1800 850 1980 935 1540 725 1640 775 1850 875 2075 980 1 NORM 1305 615 1455 685 1635 770 1800 850 1400 660 1490 705 1685 795 1890 890  N/A N/A 1310 620 1470 695 1620 765 1260 595 1340 630 1515 715 1700 800 ADJUST" Switch Positions First Stage HEAT" Speed 12 1 First Stage COOL" Speed 3 4 1 2 14 3 cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s cfm L/s + 1315 620 1490 705 1665 785 1835 865 1070 505 1155 545 1300 615 1425 670 1 NORM 1195 565 1355 640 1515 715 1670 790 975 460 1050 495 1180 555 1295 610  N/A N/A 1220 575 1365 645 1505 710 875 410 945 445 1065 500 1170 550 1 Factory default jumper setting. The effect of static pressure and is included in air volumes shown. First stage HEAT is approximately 91% of the same second stage HEAT speed position. First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position. Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm (235 L/s). Lennox Harmony zone control applications − Minimum blower heating speed is approximately 75% of the second stage HEAT speed position and the minimum blower cooling speed is approximately 45% of the second stage COOL speed position. N/A − HEAT" speed, position 1 with MINUS" adjust cannot be used with this model. G61MPV / Page 16