Transcript
LIBRETTO DI ISTRUZIONI
12 PLUS
I
MONOFASE PER SCORREVOLE NYOTA 115
INSTRUCTIONS
12 PLUS
GB
SINGLE-PHASE FOR NYOTA 115 SLIDING GATE OPERATOR
NOTICES D’INSTRUCTION
F
12 PLUS
MONOPHASE POUR OUVRE-PORTAIL COULISSANT NYOTA 115
ANLEITUNG
12 PLUS
D
Dis. N.
EINPHASIG FÜR SCHIEBETORANTRIEBE NYOTA 115
- FUNZIONE PASSO PASSO - UOMO PRESENTE - APERTURA PEDONALE - LUCE DI CORTESIA - DIAGNOSTICA A LED LUMINOSI - SPIA DI SEGNALAZIONE DELLO STATO DELL’AUTOMAZIONE - FUNZIONE OROLOGIO
- STEP BY STEP OPERATIONS - PEDESTRIAN OPENING - FAULT INDICATION BY LEDs - GATE STATUS INDICATION - TIME CLOCK OPTION
pag. 1,2,3,4
- HOLD-ON SWITCHED (DEADMAN) CONTROL - COURTESY LIGHT
- FONCTION PAS-PAS - HOMME MORT - OUVERTURE PIETON - LAMPE D’ECLAIRAGE - DIAGNOSE A LED VOYANT A DIODE - SIGNALISATION DE L’ETAT DE L’AUTOMATION PAR LED - FONCTION HORLOGE
page 1,5,6,7
page 1,8,9,10
- SCHRITT-IMPULS-FUNKTION - TOTMANN-BEDIENUNG - GEHTÜRFUNKTION - DECKENLEUCHTE - DIAGNOSE-LED - AUTOMATION-STATUS ANZEIGELAMPE - UHR-FUNKTION Seite 1,11,12,13
7022 s.n.c.
1
12 PLUS
32
31
30
4
5
6
7
8
9
10 11 12 13 14 15
15
16 17 18 19 20 21 22 COMMON
CAPACITOR
COURTESY LIGHT 100W max. - 3 min.
SAFETY CONTACT
M
SINGLE-PHASE ELECTRIC MOTOR
230V SINGLE-PHASE VOLTAGE SUPPLY
3
10
F1 - F2 Fuses = 6,3A Mains
FLASHING LAMP 230V 25W max.
8
24V OUTPUT (max. load: 2 PAIRS PHOTOCELLS 1 RADIO RECEIVER) INDICATION LAMP 24V max. 3W LIMIT SWITCH OPEN
PEDESTRIAN OPENING from 2 up to 20s
7
LIMIT SWITCH CLOSE
DWELL TIME from 2 up to 128s
6
LIMIT SWITCH COMMON
MOTOR RUN TIMEOPEN/CLOSE from 1 up to 200s
NOTE: The green LEDs must always be on.
5
STOP
R3
2
4
RADIO CONTACT
R2
1
PHOTOCELLS
R1
1 2 3 4 5 6 7 8
1
CLOSE
+
ON
OPEN
-
F3 Fuse = 630mA Transformer Protection
SETUP EDGE TYPE
COMMON PUSH BUTTONS
+
ELPRO 12
DIP-SWITCH A
TRIMMER
RADIO PLUG-IN CARD CONNECTOR
A B
1 2
-
TRANSFORMER
30 31 32 33
26 27 28
+
F4 Fuse= 2A 24V protection Secondary transformer
8,2 kΩ or NC
8,2 kΩ or NC
Terminals for the connections of the push buttons Pulin 3
-
SINGLE-PHASE FOR NYOTA 115 SLIDING GATE OPERATOR
pedestrians edge in opening edge in closing common
GB
General description: the electronic control panel Elpro 12 Plus, new generation, is designed to operate the sliding gate operator Nyota 115. Power supply is 230 V - 50 Hz single-phase. Built in full compliance with 2006/95 CE Low Voltage and 2004/108/CE Electro-Magnetic Compatibility Regulations. Fitting operations are recommended by a qualified technician in conformity to the existing safety standards. The manufacturing company declines any responsability for incorrect handling and application; also, it reserves the right to change or update the control panel any time. Failure to follow installation regulations may result into serious damage to property and persons. PLEASE NOTE: - The control panel must be installed in a sheltered, dry place, inside the box provided with it. - Make sure that the power supply to the electronic programmer is 230 V ±10% - Make sure that the power supply to the Electric Motor is 230 V ±10% - For distances of over 50 metres we recommend using electric cables with bigger sections. - Fit the mains to the control panel with a 0,03 A high performance circuit breaker. - Use 1,5 mm² section wires for voltage supply, electric motor and flashing lamp. Maximum recommended distance 50 m. - Use 1 mm² section wires for limit switches, photocells, push-buttons/key-switch and accessories. - Bridge terminals 1 and 2 if no photocells are required. - Bridge terminals 3 and 6 if no key- or push-button switches are required. N.W: To fit extra accessories such as lights, CCTV etc. use only solid state relays to prevent damages to the microprocessor.
Dip-Switch A:
DIP-SWITCH A
1= ON. Photocells. Stop while opening ON 2= ON. Radio. No reversing while opening OFF 3= ON. Automatic closing 1 2 3 4 5 6 7 8 4= ON. Preflashing activated 5= ON. Radio. Step by step. Stop in between 6= ON. Dead Man Control (Dip 4=OFF and Dip 3=OFF) 7= ON. No lamp on during dwell time 8= ON. Closing on passing across photocells
Led Status Indication: 1 4 5 6 7 8 10 15 30 31 32
ON = Photocells, if obstructed light goes off OFF = Open. Alight whenever an Open pulse is given OFF = Close. Alight whenever a Close pulse is given ON = Stop. It goes off on pulsing Stop OFF = Radio. It goes on by pressing a transmitter button ON = Limit switch Close; off when gate is closed ON = Limit switch Open; off when gate is open ON = 230 V - 50 Hz power supply. Alight OFF = Pedestrian. Alight whenever a pulse for pedestrians is given ON = Safety edge protecting opening ON = Safety edge protecting closing
In case of failure of the panel:
- Make sure that the power supply to the electronic programmer is 230 V ±10% - Make sure that the power supply to the Electric Motor is 230 V ±10% - For distances of over 50 metres we recommend using electric cables with bigger sections. - Check fuses - Check photocells if contacts are normally closed - Check all NC contacts - Check that no voltage drop has occurred from the control panel to the electric motor
Drwg. No. 7022
5
12 PLUS
GB
SINGLE-PHASE FOR NYOTA 115 SLIDING GATE OPERATOR
ELECTRICAL POWER CONNECTIONS LOW VOLTAGE ELECTRICAL CONNECTIONS
Capacitor and Single-phase Motor (230V):
29 30
R1
16 17 18 COMMON
Capacitor 20µF for 0.5HP 40µF for 1.0HP
Flashing lamp:
-
+
-
+
MOTOR RUN DWELL TIME TIME FROM 2 UP TO 128s OPEN/CLOSE FROM 1 UP TO 200s
M
DIP-SWITCH 4 and 7:
19 20
R2
Power supply: 21 22
ON: Pre-flashing OFF: No pre-flashing
4 POWER SUPPLY 230V ±10% 50Hz SINGLE-PHASE
ON: Lamp is not operating during Dwell time. Automatic mode.
7
230V MAX 25W
OFF: It flashes during Dwell Time. Automatic Mode.
Courtesy light:
l'apricance llo
23 24
Connect a 24VAC Modular Relay operate a 230V lamp
LOW VOLTAGE ELECTRICAL CONNECTIONS
Photocells: 1
DIP-SWITCH 1:
2
ON: Photocells stop gate while opening, reverse it on closing once obstacle is removed
12 13 24V OUTPUT (500 mA) (MAX. LOAD: 2 PAIRS PHOTOCELLS 1 RADIO RECEIVER)
PHOTOCELLS
1
OFF: Photocells do not stop gate while opening, reverse it on closing in case of an obstacle
Button switch:
Limit switch: 6
COMMON
OPEN
CLOSE
STOP
8
Radio Contact:
3
- Open/Close (Standard) - Travel reversing on pulsing - Step by step
9 10 LIMIT SWITCH OPEN
5
COMMON
4
LIMIT SWITCH CLOSE
3
DIP-SWITCH 2 and 5 (NEVER set BOTH of them ON at the same time):
7
ON: Gate is not reversed while opening
2 RADIO CONTACT
COMMON
Push Button Switch Pulin 3:
OFF: Any pulse reverses the gate
ON: Step by step. Stop in between
5
OFF: Standard operating mode
3 26 27 28 COMMON
Led to indicate status of Open - Stop - Close switches
24V 3W Indication Light: Light ON = Open gate Light OFF = Closed gate Flashing (fast) 0,5s = Closing gate Flashing (normally) 1s = Opening gate
Safety Contact: 3
11
14 15
This contact must be N.C. for the control panel to be allowed to work
Pedestrian opening - Trimmer R3: With the gate in fully closed position, an Open pulse to terminals 30 - 33 operates the gate for pedestrians. Setting is by means of trimmer R3. The function "Pedestrian Opening" is not in service during the first operation cycle, after a power failure.
6
Drwg. No. 7022
R3
30 31 32 33 NO
-
+
PEDESTRIAN OPENING FROM 2 UP TO 20 s
12 PLUS
GB
SINGLE-PHASE FOR NYOTA 115 SLIDING GATE OPERATOR
OPERATING MODES
Automatic / Semiautomatic:
DIP-SWITCH 3
R2
Automatic Operation: any pulse opens the gate, the gate stays open as long as the Dwell time expires as set by R2 trimmer, then it closes automatically, no pulsing is required. Semi-automatic Operation: any pulse opens the gate that stays open. A second pulse to Close is required for the gate to close.
Hold on switched (Deadman) control:
ON= Automatic Closing
-
+
Dwell Time from 2 to 128s
3
OFF= No Automatic. Semi-automatic closing by pulse
DIP-SWITCH 6 ON= Deadman Control. Dip-switch 4=OFF and Dip-switch 3=OFF
Open and Close operations are achieved “by holding a switch on” (no relay self-holding is involved) therefore a phisical attendance is required to keep the gate opening or closing until either the button or key is released.
6
OFF= Standard Operations
External Time Clock
Time Clock Installation (Optional): 3
4
ON= Automatic Closing
COMMON
OPEN
COMMON
How it works: Set the clock to the required times. On the pre-set time the gate is automatically opened and held open. Any further pulsing (even by remote control) is not accepted by the system until the time pre-set by the clock has expired. On expiring and after the pre-set dwell time the gate is closed automatically. Dip-Switch 3=ON.
DIP-SWITCH No.3=ON Automatic Closing
NO
3
OFF= No Automatic. Semi-automatic closing by pulse
SAFETY EDGES The two inputs, that are fitted to control the safety edges, are separated for the opening and closing phases. Also, it is possible to select the type of contact connected to them, either N.C. mechanical or 8,2 kΩ resistive, by means of the two jumpers “SETUP EDGE TYPE 1 - 2”. Thanks to a dedicated microcontroller circuit separately fitted on to the board, the actual integrity and correct functioning of the safety system is constantly controlled. Any possible fault or loss of efficiency is signalled by the 31 and 32 LEDs keeping flashing.
A B
A B
Selecting functioning: Once the safety edge has been engaged and the obstacle removed, the gate closes automatically. (If automatic close mode has been selected).
A B
A B
Gate travel is reversed on Opening and Closing for a short spell.
Gate travel is reversed in Opening and Closing for twice as much the spell. Accessory
Once the safety edge has been engaged and the obstacle removed, the gate stays stopped until a new pulse is given. (Even if automatic close mode has been selected).
Electrical connections
LED indication
Safety edge in OPENING: 31
Normally alight: whenever the safety edge is engaged, the LED goes off.
32
Normally alight: whenever the safety edge is engaged, the LED goes off.
8,2 kΩ
30 31 32 33
30 31 32 33
In series if safety edges are mechanical, N.C.
In parallel if safety edges are resistive 8,2 kΩ
Safety edge selection: 1 2
1 2 SETUP EDGE TYPE
NC safety edge
SETUP EDGE TYPE 8,2 kΩ Resistive safety edge
Safety edge in CLOSING: 8,2 kΩ
30 31 32 33
30 31 32 33
In series if safety edges are mechanical, N.C.
In parallel if safety edges are resistive 8,2 kΩ
Safety edge selection: 1 2
1 2 SETUP EDGE TYPE
NC safety edge
Drwg. No. 7022
SETUP EDGE TYPE 8,2 kΩ Resistive safety edge
7
05-2014 I - Prima dell’installazion e da parte di persona le tecnico qua ato, si consiglia di prendere visione del Libretto Normative di Sicurezza che la Meccani ca Fadini mette a disposizione . GB - Please not e that installation mus t be carried ou t by qu ali ed techni cians following Meccanica Fadini’s Safety Norms Manual . F - L’installation doit être e ectu ée par un techn icien qua li é suivant le m anuel des Normes de Sécurité de Meccanica Fadini. D - Vor der Montage von einem Fachm ann, wird es emp fohlen die Anleitung zur Sicherheitsnormen, die Meccanica Fadini zur Verfügung stellt, nachz ulesen.
I
Direttiva 2003/108/CE Smaltimento dei materiali elettrici ed elettronici
VIETATO GETTARE NEI RIFIUTI MATERIALI NOCIVI PER L’AMBIENTE
GB
2003/108/CE Directive for waste electrical and electronic equipments
DISPOSE OF PROPERLY ENVIRONMENT-NOXIOUS MATERIALS
s.n.c.
Via Mantova, 177/A - 37053 Cerea (Verona) Italy - Tel. +39 0442 330422 r.a. - Fax +39 0442 331054 e-mail:
[email protected] - www.fadini.net La ditta costruttrice si riser