Preview only show first 10 pages with watermark. For full document please download

50712

   EMBED


Share

Transcript

Notes Required Connection Optional Connection • Refer to the Device Compatibility Document (A15378) for compatible devices. • Total MPS-400 current drawn cannot exceed 6 A. • Each SLC loop can connect up to 198 addressable devices. • Part numbers for removable terminal blocks (TBx): 2-position (02082); 4-position (02084); 6-position (02086); 8-position (02088). Primary AC Power: 120 VAC 50/60 Hz 3 A or 240 VAC 50/60 Hz 1.5 A 1 + Circuit 1 – regulated, filtered, nonresettable power (1.25 A) to 2 – ICM-4/ICE-4 (NAC circuits), annunciator circuits, UDACT (use bell power harness PN 71093) Hot Neutral Earth Term In + Term In – Term Out + Term Out – Bwn Org Red Blk Org Red Blk Bwn 25 23 21 19 17 15 13 11 9 7 5 3 1 26 24 22 20 18 16 14 12 10 8 6 4 2 115V JP6 J3 J5 J4 Cut to enable supervision of 4XTM optional plug-in module 1 2 3 4 7 8 7 8 J1 2 1 4 3 6 5 8 7 10 9 12 11 14 13 NAC 4 Ground Fault LED TB2 TB1 Ground + 24 VDC – Power ground nc nc + 5 VDC Ground THER - 9 9 1 - 8 1 - + 8 2 + 7 2 + + 7 COM 3 4 NO NC 6 5 B501B Base 2(+) 3 1(-) LOOP - ADT-BGX-101L + ADDRESS TYPE ION 3 - - 6 4 + 5 PHOTO THER M500M M500CH - 9 9 EIA-485 Terminal mode interface to CRT-2 and ADT-LCD-80 (6,000 ft. max.) EIA-485 ACS Mode interface 1 2 1 2 34 TB3 TB5 TB4 J2 1 - 1 - 2 + 2 + 3 - 3 - 4 + 4 + M500X 1 - 2 + COM 3 4 NO NC 8 1 - + 8 7 2 + + 7 6 3 - - 6 5 4 + 5 M500CH M500X M500M 1 2 3 4 5 6 TB6 1 2 3 4 5 6 TB6 (SLC 2) – Unimode 400 only Group of panel modules (such as ICM-4, CRM-4) in second cabinet row (ADT-CAB-B3) or third cabinet row (ADT-CAB-C3) 2 1 4 3 6 5 8 7 10 9 12 11 14 13 Ribbon Row Cable (PN 71088) to panel modules 5-8 (such as ICM-4, CRM-4) in ADT-CAB-B3, ADT-CAB-C3, or ADT-CAB-D3 cabinets only J4 Relays TB4 (Supervisory) and TB5 (Security) can be set to Alarm relays by setting slide switches SW4 and SW5. • Slide SW5 to top position to set TB5 to Alarm; • Slide SW4 to top position to set TB4 to Alarm; Membrane Keypad Connector P5.1P5.8 P6.1P6.8 P7.1P7.8 P8.1P8.8 P1.1P1.8 P2.1P2.8 P3.1P3.8 P4.1P4.8 Ribbon Row Cable (PN 71088) to panel modules 1-4 (such as ICM-4, CRM-4) SW4/SW5 shown set to top position (Alarm) MPS-400 J2 1 2 3 4 JP5 – 4XTM Option Module Trouble/Supervisory J7 Optional 4XTM plug-in module + 5 VDC + 24 VDC nc nc Ground Ground Ground Ground SW4 AC Power On LED TB10 1 2 3 1 2 3 P6 J6 PHOTO Earth Ref A – SLC 2 Style 6/7 – B – SLC 2 – A + SLC 2 Style 6/7 + B + SLC 2 + 8 7 6 5 4 3 2 1 J8 1 2 3 4 TB8 NAC 3 SW5 Ground + 24 VDC – Power ground + 5 VDC Ground 1 + 5 VDC Ground TB6 NAC 2 A– A+ B– B+ Local Charger 1 2 3 A– A+ B– B+ 1 2 3 4 5 6 7 8 NAC 1 A– A+ B– B+ TB4 1 2 3 J6 P1 J1 8 7 6 5 4 3 2 1 P1 JP1 C NC NO 4 5 6 7 8 F1 10A 3AG, 32V PN 12046 C NC NO P6 CPU Power Harness 1 PN 75396 (ADT-CAB-400AA) 2 PN 75395 (ADT-CAB-3 Series) 3 1 2 3 1 2 3 TB5 1 2 3 4 TB7 1 2 3 4 TB9 Supervisory Security P2 Prim Sec TB2 120/240 VAC Select Switch TB3 A– A+ B– B+ Sec Prim 1 2 3 4 56 C NC NO C NC NO S9 Alarm Trouble 6 7 ION Earth Ref A – SLC 1 Style 6/7 – B – SLC 1 – A + SLC 1 Style 6/7 + B + SLC 1 + 4 5 A– A+ B– B+ 3 ADT-BGX-101L ADDRESS TYPE Four-wire SLC – Typical wiring of a four-wire (Style 6) SLC loop (supervised and power-limited) ADT-UDACT, ADT-ACM-8R, ADT-NIB-96, AMG-1, ADTUZC-256, RPT-485, ADTLDM-32 (6,000 ft. max.) 1 2 3 4 1 2 TB1 - + LOOP ACS + to ACS Annunciators (640 ACS – control points), ADT-LCD-80, +– Ground Cable PN 71033 B501B Base EIA-232 Terminal interface to CRT-2, modem, or personal computers with Uni•Tility upload/download utility (50 ft. Max.) If using a modem, reverse TX and RX. Pin 3 Pin 2 Pin 7 Tx Tx Rx Rx Ref Ref 3 + Circuit 2 – regulated, filtered, nonresettable power (1.25 A) to 4 – ICM-4/ICE-4 (NAC circuits), annunciator circuits, ADT-UDACT (use bell power harness PN 71093) 5 + Circuit 3 – regulated, filtered resettable (1.25 A) to 6 – four-wire smoke detectors or ACS annunciators, power-limited and supervision required NAC Style Y Unused NAC NAC Style Z (Class B) Connection Note: Each NAC can (Class A) Connection (2.25 A max.) (2.25 A max.) use up to 2.25 A Connection ELR 2.2K 1/2W (2.25 A max.) ELR 2.2K 1/2W maximum; up to 6 A for all NACs combined. +– Batt. + Pin 3 EIA-232 printer interface for EDP-listed Pin 2 equipment (PRN-4/Keltron printer Pin 7 connection shown) DB-25 Connector Tx Tx Rx Rx Ref Ref DC Power Outputs (24 VDC) Batt. – Battery Power Cable PN 71070 Two-wire SLC – Typical wiring of a two-wire (Style 4) SLC loop (supervised and power-limited) DB-25 Connector TB3-TB6 – Form-C relays rated at 2A, 30 VDC resistive. JP2 Ground fault disable Bell circuit logic and power supply trouble signals J9 1 2 34 J3 25 23 21 19 17 15 13 11 9 Auxiliary Trouble Cable – AMG (P9), AVPS-24 (P2) PN 75098 (24 in.) PN 71033 (60 in.) (Includes ADT-CPU-300 and ADT-CPU-400) Group of panel modules (such as ICM-4, CRM-4) in first, second, or third cabinet row. If installing modules in the first cabinet row, P3 and P4 are not used. 7 5 3 1 26 24 22 20 18 16 14 12 10 8 6 4 2 25 23 21 19 17 15 13 11 9 MPM-2 – Optional voltmeter ADT-CPU 7 5 3 1 P3 26 24 22 20 18 16 14 12 10 8 6 4 2 ADT-CPU EIA-485 ACS Connection TB4-1 TB4-2 Power Ribbon Cable PN 75398 (ADT-CAB-400AA) PN 75394 (ADT-CAB-3 Series) 6 Security Tamper Switch Input – STS-200 (ADT-CAB-400AA); STS-1 (ADT-CAB-3 Series) Cable PN 75148 P2 4 P3 Aux. Trouble cable to MPS-400 J4 PN 75098 (24 in.) PN 71033 (60 in.) P9 Zone Coder Input – ADT-UZC-256 TB1 Cable PN 71093 P1 Accessory Cable ADT-CAB-400AA – 75396 ADT-CAB-X3 – 75100 AMG-1, AMG-E, or ATG-2 Unimode 300/Unimode 400 Basic System Connections Document 50712:B Revision: B ECN 98-213 JSR 05/11/98