50ez-06pd

   EMBED


Share

Transcript

50EZ---A Comfortt t 13 SEER Single ---Packaged Heat Pump System with PuronR (R ---410A) Refrigerant Single and Three Phase 2 to 5 Nominal Tons (Sizes 24---60) Product Data A09034 Fig. 1 -- Unit 50EZ--A Single--Packaged Products with Energy--Saving Features and PuronR refrigerant. S Up to 13.5 SEER S Up to 7.7 HSPF S Up to 11.5 EER at 95_F OD S Factory--Installed TXV S ECM Motor--Standard S Dehumidification Feature FEATURES/BENEFITS One--piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High--efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 13.5. Puron Environmentally Sound Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems, proving highly reliable, environmentally sound performance. Easy Installation Factory--assembled package is a compact, fully self--contained, heat pump unit that is prewired, pre--piped, and pre--charged for minimum installation expense. These units are available in a variety of standard capacity ranges with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design On the inside a high--tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Durable, dependable components Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. ECM Motor is standard on all 50EZ--A models. Direct--drive, PSC (Permanent Split Capacitor) condenser--fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40_F (4.4_C) outdoor temperature. MotormasterR II low ambient kit is available as a field installed accessory. Thermostat controls designed to work as a system with Carrier’s small packaged product. Thermostatic Expansion Valve -- A hard shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. Indoor and Outdoor coils are computer--designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 74dBA. Easy to service cabinets provide easy 3--panel accessibility to serviceable components during maintenance and installation. The base with integrated drain pan provides easy ground level installation with a mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4--in. (19.05 mm) wide perimeter flange makes frame mounting on a rooftop easy. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. 1 Cabinets are constructed of heavyduty, phosphated, zinc--coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi--rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. Short--Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/--2 minutes) before restarting compressor after shutdown for any reason. TABLE OF CONTENTS 50EZ-- A FEATURES/BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1--2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . 2 AHRI CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . 5 BASE UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . 7--8 ACCESSORY DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SELECTION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . 10 PERFORMANCE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . 11--19 TYPICAL PIPING AND WIRING . . . . . . . . . . . . . . . . . . . . . 20 APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22--23 TYPICAL WIRING SCHEMATICS . . . . . . . . . . . . . . . . . 24--29 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . 31--32 MODEL NUMBER NOMENCLATURE 50EZ --- A 24 --- --- --- 3 0 Type of Unit 50EZ --- Single Packaged Heat Pump System --- --- Options FE --- Economizer (3 Phase Only) TP --- Base unit with tin plated indoor coil hairpins (Single Phase Only N/A See Price Page for full list of factory options. Only used if ordering an option Major Series Nominal Cooling Capacity 24 --- 2.0 Tons 30 --- 2.5 Tons 36 --- 3.0 Tons 42 --- 3.5 Tons 48 --- 4.0 Tons 60 --- 5.0 Tons Minor Series Electrical Supply 3 --- 208/230--- 1--- 60 5 --- 208/230--- 3--- 60 6 --- 460--- 3--- 60 N/A Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. 2 AHRI* CAPACITIES COOLING CAPACITIES AND EFFICIENCIES UNIT 50EZ-- A NOMINAL TONS STANDARD CFM 24-- - - 30 30-- - - 30/50 36-- - - 30/50 42-- - - 30/50 48-- - - 30/50 60-- - - 30/50 2 2--1/2 3 3--1/2 4 5 800 1000 1200 1400 1600 1850 COOLING CAPACITIES (Btuh) 23,800 29,000 35,000 40,000 47,000 57,000 EER** SEER† 11.5 11.5 11.5 11.5 11.5 11.5 13.5 13.5 13.5 13.2 13.5 13.5 UNIT 50EZ---A HEATING CAPACITY (Btuh) @ 47_F (8.3_C) COP @ 47_F (8.3_C) HEATING CAPACITY (Btuh) @ 17_F (---8.3_C) COP @ 17_F (---8.3_C) HSPF† 24-- - - 30 23,400 3.5 10,800 2.2 7.7 30-- - - 30/50 36-- - - 30/50/60 29,000 35,000 3.5 3.4 15,900 20,400 2.2 2.3 7.7 7.7 42-- - - 30/50/60 48-- - - 30/50/60 40,000 46,500 3.4 3.6 22,000 26,200 2.2 2.3 7.7 7.7 60-- - - 30/50/60 57,000 3.5 31,000 2.3 7.7 LEGEND dB--- Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance HSPF---Heating Season Performance Factor * Air Conditioning, Heating & Refrigeration Institute. **At “A” conditions---80_F (26.7_C) indoor db/67_F (19.4_C) indoor wb & 95_F (35_C) outdoor db. { Rated in accordance with U.S. Government DOE Department of Energy) test procedures and/or AHRI Standards 210/240. Notes: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80qF (26.7_C) db, 67qF (19.4_C) wb indoor entering--air temperature and 95qF (35_C) db outdoor entering---air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. 3 50EZ-- A HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES PHYSICAL DATA -- UNIT 50EZ--A 50EZ-- A UNIT SIZE NOMINAL CAPACITY (ton) SHIPPING WEIGHT} (lb) (kg) COMPRESSOR QUANTITY TYPE REFRIGERANT Refrigerant (R --- 410A) Quantity (lb) Quantity (kg) METERING DEVICE ID 50EZ--- A24 2 327 148 50EZ--- A30 2.5 340 154 9.6 4.4 50EZ--- A36 3 343 156 50EZ--- A42 3.5 419 190 50EZ--- A48 4 437 198 50EZ--- A60 5 462 210 9.6 4.4 12.3 5.6 1 SCROLL COMPRESSOR R---410A 7.9 10.0 3.6 4.5 TXV 10.2 4.6 0.038 (Left OD Coil) 0.040 (Right OD Coil) ORIFICE OD (in.) 0.032 (2) 0.035 (2) 0.037 (2) 0.046 (2) 0.052 (2) .97/1.02 (mm) .81 .89 .94 1.2 1.3 OUTDOOR COIL 2...21 2...21 2...21 2...21 2...21 2...21 Rows... Fins/in. 11.9 11.9 11.9 13.6 13.6 17.5 face area (sq. ft.) OUTDOOR FAN 2700 2700 2700 3100 3100 3100 Nominal Airflow (CFM) 24 24 24 26 26 26 Fan Diameter (in.) 610 610 610 660 660 660 Fan Diameter (mm) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) 1/5 (810) Diameter Motor HP (RPM) INDOOR COIL 3...17 3...17 3...17 3...17 3...17 3...17 Rows... Fins/in. 3.7 3.7 3.7 4.7 4.7 5.7 face area (sq. ft.) INDOOR BLOWER 800 1000 1200 1400 1600 1850 Nominal Cooling Airflow (CFM) 10x10 10x10 11x10 11x10 11x10 11x10 Size (in.) 254x254 254x254 279x254 279x254 279x254 279x254 (mm) 1/2 1/2 3/4 3/4 1.0 1.0 Motor (HP) HIGH --- PRESSURE SWITCH (psig) 650r15 Cutout 420r25 Reset (Auto) LOSS--- OF--- CHARGE/LOW --- PRESSURE 20r5 SWITCH 45r10 (Liquid Line) (psig) 20r5 Cutout 45r10 Reset (Auto) RETURN--- AIR FILTERS*{ 20x20x1 20x24x1 24x30x1 24x36x1 throwaway (in.) 508x508x25 508x610x25 610x762x25 610x914x25 (mm) *Required filter sizes shown are based on the larger of the AHRI (Air Conditioning, Heating and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. W.C. { If using accessory filter rack refer to the filter rack installation instructions for correct filter size and quantity. } For 460 volt units, add 14 lb (6.4 kg) to the weight. A-Weighted Sound Power Level (dBA) MODEL 50EZ---A 24--- --- --- 30 30--- --- --- 30/50 36--- --- --- 30/50 42--- --- --- 30/50 48--- --- --- 30/50 60--- --- --- 30/50 STANDARD RATING (dBA) 76 76 77 78 78 76 TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment) 125 250 500 1000 2000 4000 8000 57.0 60.5 63.0 65.0 62.0 63.0 65.5 67.5 68.0 68.5 68.5 66.5 72.0 72.0 73.0 74.5 74.0 69.5 71.0 70.0 71.0 72.5 72.5 71.0 67.0 67.0 67.0 69.5 70.0 66.0 62.0 61.0 62.0 64.5 64.0 65.0 53.0 51.5 55.0 56.5 56.0 59.0 NOTE: Tested in accordance with AHRI Standard 270 (not listed in AHRI). 4 OPTIONS AND ACCESSORIES DESCRIPTION Coil Options Compressor Start Kit Corporate Thermostats Crankcase Heater Economizer Electric Heaters Filter Rack Flat Roof Curbs Low Ambient Kit Louver Metal Outdoor Coil Grilles Manual Outside Air Damper Square ---to ---Round Duct Transition Kit Time Guard II Dual Point Electric Heaters Base unit with tin plated indoor coil hairpins Compressor Start Kit assists compressor start---up by providing additional starting torque on sing phase units only. Thermostats provide control for the system heating and cooling functions. Crankcase Heater provides anti---floodback protection for low--load cooling applications. Horizontal Economizer with solid state controls and barometric relief dampers includes filter racks and provide outdoor air during cooling and reduce compressor operation. Vertical Economizer with solid state controls and barometric relief dampers includes filter racks and provide outdoor air during cooling and reduce compressor operation. Electric Heat Supplement Filter Rack features easy installation, serviceability, and high --filtering performance for vertical applications. Includes 1 ---in. filter. Flat Roof Curbs in both 11 ---in (279 mm) and 14 ---in. (356 mm) sizes are available for roof mounted applications. Low Ambient Kit (Motormaster II Control) allows the use of mechanical cooling down to outdoor temperatures as low as 0°F ( ---18° C) when properly installed. Louver Metal Outdoor Coil Grilles provides hail and vandalism protection. Manual Outside Air Damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. Square ---to ---Round Duct Transition Kit enable 24 ---48 size units to be fitted to 14 in. (356 mm) round ductwork. Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown of the compressor. Not required when a corporate programmable thermostat is applied or with a RTU ---MP control. Allows you to power the electric heater and unit contactor separately by having two individual field power supply circuits connected respectively. FACTORY INSTALLED OPTION X FIELD INSTALLED ACCESSORY X X X* X X X X 50EZ-- A ITEM X X X X X X X *Refer to Price Page for application detail. ELECTRIC HEATERS NOMINAL CAPACITY (kW @ 240 or 480 VOLTS) 24 CPHEATER052A00 5.0 X X X CPHEATER064A00 5.0 X X CPHEATER070A00 7.2 X X CPHEATER050A00 10.0 X CPHEATER066A00 15.0 CPHEATER054A00 20.0 ORDERING NO. USED WITH SIZES 30 36 42 48 60 X X X X X X X X X X X X X X X X X X X X X X 208/230 --- SINGLE PHASE --- 60 HZ 208/230 --- THREE PHASE --- 60 HZ CPHEATER055A00 5.0 X X X X CPHEATER056A00 10.0 X X X X CPHEATER068A00 10.0 X X X X CPHEATER058A00 15.0 X X X X X CPHEATER059A01 20.0 X X X CPHEATER060A00 5.0 X X X X CPHEATER061A00 10.0 X X X X CPHEATER062A00 15.0 X X X X X X X X 460 --- THREE PHASE --- 60 HZ CPHEATER063A00 20.0 NOTE: Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages. X = Approved combination Minimum Airflow for Reliable Electric Heater Operation (CFM) SIZE AIRFLOW (CFM) 50EZ-- A24 800 50EZ-- A30 1025 50EZ-- A36 1250 5 50EZ-- A42 1400 50EZ-- A48 1710 50EZ-- A60 1800 ECONOMIZER COIL FILTER 50EZ-- A ECONOMIZER CAULK BOTTOM CORNER OF ECONOMIZER ON EACH SIDE SIDE VIEW FI LTER Vertical Economizer COIL ECONOMIZER BASE FLANGE ON BASE DETAIL FILTER RACK BEND FLANGE AT 90° -SCREW TO DIVIDER WITH 1-IN. (25 mm) SCREW Horizontal Economizer TOP FILTER RACK EV APORATOR COIL MANUAL OUTSIDE AIR DAMPER REPLACEMENT PANEL MANUAL OUTSIDE AIR HOOD DAMPER BLADE BOTTOM FILTER RACK A09375 6 50EZ-- A UNIT DIMENSIONS - 50EZ--A24--36 A09460 7 50EZ-- A UNIT DIMENSIONS - 50EZ--A42--60 A09461 8 ROOF CURB ACCESSORY DIMENSIONS Dashed lines show cross support location for large basepan units. B G HVAC unit basepan HVAC unit base rails C Sealing Gasket Roofcurb A Anchor screw H F Wood nailer* Flashing field supplied Roofcurb* Insulation (field supplied) E D Cant strip field supplied SMALL/COMMON CURB 50EZ-- A Roofing material field supplied A09413 *Provided with roofcurb A09090 ROOF CURB DETAIL B C G SUPPLY AIR SMALL BASE UNIT RETURN AIR LARGE BASE UNIT H F A E D UNIT PLACEMENT ON COMMON CURB SMALL OR LARGE BASE UNIT A09415 LARGE CURB A09094 A09414 UNIT SIZE CATALOG NUMBER A IN. (mm) Small or Large CPRFCURB010A00 11 (279) CPRFCURB011A00 14 (356) CPRFCURB012A00 CPRFCURB013A00 11 (279) 14 (356) Large B (small/common base) IN. (mm)* B (large base) IN. (mm)* C IN. (mm) D IN. (mm) 16 (406) 47.8 (1214) 10 (254) 14 (356) 14 (356) E IN. (mm) 32.4 (822) 43.9 (1116) F IN. (mm) G IN. (mm) 30.6 (778) 2.7 (69) H IN. (mm) 46.1 (1170) 42.2 (1072) * Part Numbers CPRCURB010A00 and CPRCURB011A00 can be used on both small and large basepan units. The cross supports must be located based on whether the unit is a small basepan or a large basepan. NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16--gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1--in. (25.4 mm) thick fiberglass 1 lb. density. 9 50EZ-- A SELECTION PROCEDURE (WITH EXAMPLE) 1. Determine cooling and heating requirements at design conditions: 4. Determine fan speed and power requirements at design conditions. Given: Required Cooling Capacity (TC) . . . . . . . . . . 34,500 Btuh Sensible Heat Capacity (SHC) . . . . . . . . . . . . 26,000 Btuh Required Heating Capacity . . . . . . . . . . . . . . . 60,000 Btuh Condenser Entering Air Temperature . . . . . . . 95qF (35qC) Indoor--Air Temperature 80qF (27qC) edb 67qF (19qC) ewb Evaporator Air Quantity . . . . . . . . . . . . . . . . . . 1200 CFM External Static Pressure . . . . . . . . . . . . . . . . 0.200 IN.W.C. Electrical Characteristics . . . . . . . . . . . . . . . . . . . 208--1--60 Before entering the air delivery tables, calculate the total static pressure required. From the given example, the Wet Coil Pressure Drop Table, and the Filter Pressure Drop Table: External Static Pressure 0.200 IN. W.C. Filter 0.130 IN. W.C. Wet Coil Pressure Drop 0.18 IN. W.C. Total Static Pressure 0.51 IN. W.C. Enter the table for Dry Coil Air Delivery— At 0.50 IN. W.C. ESP (external static pressure) and MEDIUM speed the motor delivers 1209 cfm. 2. Select unit based on required cooling capacity. 5. Select unit that corresponds to power source available. Enter Net Cooling Capacities table at condenser entering temperature of 95qF (35qC). Unit 036 at 1200 cfm and 67qF (19qC) ewb (entering wet bulb) will provide a total capacity of 35,000 Btuh and a SHC of 26,200 Btuh. Calculate SHC correction, if required, using Note 4 under Cooling Capacities tables. The Electrical Data Table shows that the unit is designed to operate at 208/230--1--60. 3. Select heating capacity of unit to provide design condition requirement. In the Heating Capacities and Efficiencies table, note that the 36 size unit will deliver 35,000 BTUH at the ARI high temp rating point. To achieve 60,000 BTUH, accessory electric heat will be required. Use the Balance Point Worksheet to plot the load line with the unit capacity. The difference between the load line and unit capacity at the design heating temperature is the amount of electric heat that will be required. 10 11 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EWB _F (_C) 19.53 20.43 16.36 29.56 24.10 24.64 26.89 24.45 24.45 24.92 15.54 29.00 22.63 24.02 19.21 23.50 23.50 26.34 14.67 28.26 18.39 17.94 25.65 24.39 17.21 21.00 23.32 23.73 22.38 22.38 75 (23.9) Capacity MBtuh Total Sens 1.71 1.66 1.63 1.63 1.63 1.68 1.63 1.61 1.60 1.60 1.65 1.60 1.58 1.58 1.57 Total Sys KW 28.16 25.60 23.72 23.54 23.48 27.64 25.11 23.24 22.92 22.59 26.98 24.48 22.64 22.26 21.54 15.83 19.87 18.97 23.54 23.48 15.04 18.67 17.85 22.02 22.59 14.19 17.42 16.69 20.45 21.54 85 (29.4) Capacity MBtuh Total Sens 1.92 1.87 1.84 1.84 1.84 1.89 1.84 1.81 1.81 1.81 1.86 1.81 1.79 1.79 1.78 Total Sys KW 26.67 24.25 22.45 22.49 22.45 26.19 23.80 22.02 21.77 21.61 25.61 23.23 21.47 21.13 20.63 15.26 19.27 18.37 22.49 22.45 14.53 18.10 17.28 21.32 21.61 13.68 16.87 16.14 19.85 20.63 2.15 2.10 2.07 2.07 2.07 2.12 2.07 2.04 2.04 2.04 2.08 2.04 2.02 2.02 2.01 25.07 22.78 21.07 21.34 21.31 24.66 22.38 20.69 20.58 20.54 24.14 21.88 20.21 19.92 19.64 14.65 18.63 17.72 21.34 21.31 13.93 17.48 16.67 20.58 20.54 13.14 16.28 15.55 19.18 19.64 2.40 2.35 2.32 2.32 2.32 2.37 2.32 2.30 2.30 2.30 2.34 2.30 2.27 2.27 2.27 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW 75 70 65 EDB _F (_C) 700 800 900 700 800 900 700 800 900 CFM INDOOR AIR 7.81 7.93 8.02 7.49 7.61 7.71 7.14 7.25 7.37 7.18 7.29 7.38 6.89 7.00 7.09 6.57 6.67 6.78 1.51 1.51 1.52 1.59 1.59 1.59 1.67 1.67 1.67 --- 10 (--- 23.3) Capacity Total MBtuh Sys KW Total Integ 10.21 10.35 10.45 9.88 10.04 10.16 9.56 9.71 9.83 9.39 9.52 9.62 9.10 9.24 9.35 8.80 8.93 9.04 0 (--- 17.8) Capacity MBtuh Total Integ 1.62 1.62 1.62 1.70 1.70 1.70 1.79 1.78 1.78 Total Sys KW 13.03 13.17 13.28 12.47 12.72 12.88 12.14 12.31 12.46 11.96 12.09 12.19 11.44 11.68 11.82 11.14 11.30 11.43 10 (--- 12.2) Capacity MBtuh Total Integ 1.71 1.70 1.69 1.79 1.78 1.77 1.88 1.86 1.86 Total Sys KW 24 Heating Extended Performance Table --10--60 (--23.3--15.6_C) 15.49 15.63 15.76 15.29 15.43 15.55 15.07 15.22 15.35 14.05 14.18 14.29 13.87 14.00 14.10 13.67 13.81 13.92 1.76 1.74 1.73 1.86 1.83 1.82 1.96 1.93 1.92 18.20 18.38 18.54 17.96 18.14 18.28 17.72 17.89 18.04 15.95 16.11 16.24 15.74 15.89 16.02 15.52 15.68 15.81 1.81 1.78 1.76 1.91 1.87 1.85 2.01 1.98 1.95 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (--- 6.7) 30 (--- 1.1) Capacity Capacity Total Total MBtuh MBtuh Sys Sys KW KW Total Integ Total Integ 21.29 21.53 21.73 20.99 21.22 21.42 20.69 20.92 21.11 1.87 1.83 1.80 1.97 1.93 1.90 2.08 2.03 2.00 50EZ-- A 21.29 21.53 21.73 20.99 21.22 21.42 20.69 20.92 21.11 2.67 2.63 2.60 2.61 2.61 2.65 2.60 2.58 2.58 2.58 2.62 2.58 2.56 2.56 2.56 Total Sys KW 24.98 25.30 25.52 24.59 24.90 25.15 24.22 24.53 24.76 24.98 25.30 25.52 24.59 24.90 25.15 24.22 24.53 24.76 50 (10) Capacity MBtuh Total Integ 13.99 23.33 Total Sys KW 17.93 17.01 20.10 20.06 13.29 16.81 15.98 19.40 19.37 12.55 15.64 14.89 18.50 18.54 21.18 19.58 20.10 20.06 22.98 20.84 19.25 19.40 19.37 22.52 20.41 18.82 18.63 18.54 115 (46.1) Capacity MBtuh Total Sens 40 (4.4) Capacity MBtuh Total Integ *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 900 / 0.20 800 / 0.15 700 / 0.11 CFM / BF EVAPORATOR AIR 24 Cooling Extended Performance Table PERFORMANCE DATA 1.97 1.92 1.89 2.07 2.02 1.99 2.18 2.12 2.09 Total Sys KW 21.45 19.46 17.97 18.71 18.69 21.15 19.17 17.68 18.10 18.07 20.77 18.80 17.32 17.36 17.33 29.37 29.63 29.60 28.92 29.27 29.31 28.47 28.86 28.98 29.37 29.63 29.60 28.92 29.27 29.31 28.47 28.86 28.98 60 (15.6) Capacity MBtuh Total Integ 13.27 17.14 16.22 18.71 18.69 12.59 16.06 15.23 18.10 18.07 11.88 14.93 14.19 17.36 17.33 125 (51.7) Capacity MBtuh Total Sens 2.13 2.05 2.02 2.23 2.16 2.12 2.34 2.28 2.22 Total Sys KW 2.98 2.94 2.92 2.93 2.93 2.95 2.92 2.90 2.90 2.90 2.93 2.89 2.88 2.88 2.88 Total Sys KW 12 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EWB _F (_C) 23.63 24.80 19.76 30.27 32.74 36.13 30.03 29.95 29.95 30.03 18.74 35.47 27.45 29.25 23.29 28.78 28.78 32.09 17.68 34.57 22.24 21.73 31.27 29.64 20.79 25.49 28.39 28.86 27.44 27.44 75 (23.9) Capacity MBtuh Total Sens 2.11 2.09 2.07 2.07 2.07 2.08 2.05 2.04 2.04 2.04 2.04 2.02 2.00 2.00 2.00 Total Sys KW 34.40 31.17 28.80 28.81 28.75 33.78 30.58 28.24 27.91 27.67 32.97 29.83 27.53 27.09 26.40 19.10 24.11 22.96 28.81 28.75 18.14 22.64 21.59 26.71 27.67 17.10 21.10 20.17 24.83 26.40 85 (29.4) Capacity MBtuh Total Sens 2.34 2.31 2.29 2.30 2.29 2.30 2.28 2.26 2.26 2.26 2.26 2.24 2.22 2.22 2.22 Total Sys KW 32.60 29.54 27.27 27.55 27.50 32.02 29.00 26.76 26.55 26.49 31.32 28.33 26.13 25.75 25.31 18.43 23.41 22.26 27.55 27.50 17.52 21.96 20.92 26.55 26.49 16.50 20.46 19.52 24.11 25.31 2.58 2.56 2.54 2.54 2.54 2.55 2.52 2.51 2.50 2.50 2.51 2.49 2.47 2.47 2.47 30.70 27.80 25.65 26.20 26.15 30.20 27.32 25.20 25.27 25.23 29.56 26.73 24.63 24.34 24.13 17.73 22.67 21.50 26.20 26.15 16.83 21.25 20.20 25.27 25.23 15.87 19.77 18.84 23.30 24.13 2.86 2.83 2.82 2.82 2.82 2.82 2.80 2.78 2.79 2.78 2.79 2.76 2.75 2.75 2.75 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW 75 70 65 EDB _F (_C) 875 1000 1125 875 1000 1125 875 1000 1125 CFM INDOOR AIR 8.58 8.75 8.92 8.06 8.24 8.40 7.50 7.68 7.84 Total 7.89 8.05 8.20 7.42 7.58 7.73 6.90 7.06 7.21 Integ Capacity MBtuh --- 10 (--- 23.3) 1.91 1.92 1.95 1.98 2.00 2.02 2.06 2.08 2.11 Total Sys KW 11.60 11.81 11.99 11.12 11.33 11.51 10.60 10.81 11.00 Total 10.67 10.87 11.04 10.23 10.42 10.59 9.76 9.95 10.12 Integ Capacity MBtuh 0 (--- 17.8) 1.98 1.99 2.00 2.06 2.07 2.09 2.15 2.16 2.18 Total Sys KW 14.83 15.07 15.28 14.37 14.62 14.83 13.88 14.13 14.34 Total 13.61 13.83 14.02 13.19 13.42 13.61 12.74 12.97 13.16 Integ Capacity MBtuh 10 (--- 12.2) 2.04 2.05 2.06 2.13 2.14 2.15 2.22 2.23 2.24 Total Sys KW 30 Heating Extended Performance Table --10--60 (--23.3--15.6_C) 18.37 18.71 19.32 17.90 18.19 18.43 17.41 17.69 17.94 Total 16.66 16.97 17.52 16.23 16.49 16.71 15.79 16.05 16.27 Integ Capacity MBtuh 2.12 2.11 2.12 2.21 2.20 2.21 2.31 2.30 2.30 Total Sys KW 22.35 22.60 22.81 22.07 22.30 22.51 21.72 21.99 22.21 Total 19.58 19.80 19.98 19.33 19.54 19.72 19.03 19.27 19.46 Integ Capacity MBtuh 2.21 2.19 2.18 2.31 2.29 2.28 2.42 2.40 2.39 Total Sys KW OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (--- 6.7) 30 (--- 1.1) 26.08 26.39 26.65 25.74 26.03 26.29 25.38 25.68 25.93 Total 26.08 26.39 26.65 25.74 26.03 26.29 25.38 25.68 25.93 Integ 2.29 2.26 2.24 2.40 2.36 2.35 2.51 2.48 2.46 50 (10) 3.17 3.15 3.14 3.14 3.14 3.14 3.12 3.10 3.11 3.11 3.10 3.08 3.07 3.07 3.07 Total Sys KW 30.29 30.70 31.04 29.87 30.27 30.57 29.46 29.83 30.13 30.29 30.70 31.04 29.87 30.27 30.57 29.46 29.83 30.13 Integ Capacity MBtuh Total 16.98 28.69 Total Sys KW 21.86 20.68 24.73 24.69 16.11 20.48 19.42 23.88 23.84 15.20 19.04 18.09 22.88 22.83 25.95 23.91 24.73 24.69 28.25 25.54 23.51 23.88 23.84 27.68 25.00 23.00 22.88 22.83 115 (46.1) Capacity MBtuh Total Sens 40 (4.4) Capacity MBtuh *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1125 / 0.21 1000 / 0.17 875 / 0.13 CFM / BF EVAPORATOR AIR 30 Cooling Extended Performance Table PERFORMANCE DATA (CONT) 50EZ-- A 2.39 2.35 2.32 2.50 2.46 2.43 2.62 2.57 2.54 Total Syst em KW 26.51 23.97 22.05 23.14 23.10 26.14 23.60 21.69 22.37 22.33 25.66 23.14 21.25 21.45 21.42 35.28 35.83 36.29 34.73 35.27 35.70 34.18 34.70 35.14 Total 35.28 35.83 36.29 34.73 35.27 35.70 34.18 34.70 35.14 Integ Capacity MBtuh 60 (15.6) 16.17 20.96 19.77 23.14 23.10 15.32 19.64 18.56 22.37 22.33 14.44 18.24 17.29 21.45 21.42 125 (51.7) Capacity MBtuh Total Sens 2.52 2.47 2.43 2.64 2.58 2.54 2.75 2.69 2.66 Total Syst em KW 3.53 3.51 3.50 3.51 3.51 3.49 3.48 3.47 3.47 3.47 3.46 3.45 3.44 3.44 3.44 Total Sys KW 13 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EWB _F (_C) 29.59 23.36 39.63 43.50 36.49 36.54 28.29 36.41 36.41 36.85 22.23 42.86 33.01 35.71 27.86 35.11 35.11 38.99 21.04 41.96 26.69 26.06 38.13 36.21 25.01 30.70 34.77 35.34 33.59 33.59 75 (23.9) Capacity MBtuh Total Sens 2.58 2.55 2.53 2.53 2.52 2.53 2.50 2.47 2.47 2.47 2.47 2.44 2.42 2.42 2.41 Total Sys KW 41.27 37.64 34.96 34.95 34.89 40.74 37.07 34.40 33.97 33.69 39.94 36.31 33.64 33.10 32.25 22.59 28.75 27.46 34.95 34.89 21.48 27.06 25.89 32.07 33.69 20.31 25.28 24.23 29.87 32.25 85 (29.4) Capacity MBtuh Total Sens 2.85 2.81 2.78 2.79 2.78 2.79 2.76 2.73 2.73 2.73 2.74 2.70 2.68 2.67 2.67 Total Sys KW 38.89 35.49 32.97 33.28 33.23 38.42 35.00 32.47 32.20 32.14 37.75 34.33 31.81 31.33 30.82 21.74 27.86 26.58 33.28 33.23 20.68 26.20 25.03 32.20 32.14 19.54 24.46 23.40 28.94 30.82 3.13 3.10 3.07 3.07 3.07 3.08 3.04 3.02 3.02 3.02 3.03 2.99 2.96 2.96 2.96 36.32 33.16 30.82 31.47 31.42 35.93 32.76 30.40 30.50 30.45 35.39 32.20 29.83 29.46 29.24 20.81 26.89 25.61 31.47 31.42 19.82 25.27 24.10 30.50 30.45 18.70 23.57 22.52 27.90 29.24 3.45 3.42 3.39 3.40 3.40 3.40 3.37 3.34 3.34 3.34 3.35 3.31 3.29 3.29 3.28 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW 75 70 65 EDB _F (_C) 1050 1200 1350 1050 1200 1350 1050 1200 1350 CFM INDOOR AIR 12.15 12.38 12.59 11.71 11.94 12.15 11.23 11.46 11.67 11.18 11.39 11.58 10.77 10.99 11.18 10.33 10.55 10.74 2.30 2.32 2.35 2.41 2.44 2.47 2.53 2.56 2.59 --- 10 (--- 23.3) Capacity Total MBtuh Sys KW Total Integ 15.31 15.57 15.79 14.88 15.13 15.37 14.42 14.68 14.91 14.08 14.32 14.53 13.69 13.93 14.14 13.27 13.51 13.72 0 (--- 17.8) Capacity MBtuh Total Integ 2.39 2.40 2.43 2.50 2.52 2.54 2.62 2.64 2.67 Total Sys KW 19.19 19.41 19.62 18.76 19.13 19.35 18.01 18.31 18.61 17.61 17.82 18.01 17.22 17.55 17.76 16.53 16.81 17.08 10 (--- 12.2) Capacity MBtuh Total Integ 2.49 2.50 2.52 2.61 2.62 2.64 2.72 2.73 2.75 Total Sys KW 36 Heating Extended Performance Table --10--60 (--23.3--15.6_C) 22.68 22.96 23.19 22.39 22.65 22.88 22.09 22.36 22.59 20.57 20.82 21.03 20.31 20.54 20.75 20.03 20.27 20.48 2.58 2.58 2.59 2.70 2.70 2.71 2.84 2.83 2.84 26.68 27.01 27.29 26.32 26.63 26.91 25.96 26.27 26.53 23.38 23.66 23.91 23.06 23.34 23.58 22.75 23.02 23.24 2.68 2.67 2.67 2.80 2.79 2.80 2.94 2.92 2.93 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (--- 6.7) 30 (--- 1.1) Capacity Capacity Total Total MBtuh MBtuh Sys Sys KW KW Total Integ Total Integ 31.28 31.68 32.01 30.81 31.21 31.54 30.36 30.74 31.07 2.80 2.78 2.78 2.93 2.91 2.91 3.06 3.04 3.03 50EZ-- A 31.28 31.68 32.01 30.81 31.21 31.54 30.36 30.74 31.07 3.82 3.78 3.76 3.77 3.77 3.76 3.73 3.71 3.71 3.71 3.71 3.68 3.66 3.66 3.66 Total Sys KW 36.70 37.20 37.51 36.14 36.62 37.00 35.58 36.04 36.43 36.70 37.20 37.51 36.14 36.62 37.00 35.58 36.04 36.43 50 (10) Capacity MBtuh Total Integ 19.82 33.56 Total Sys KW 25.82 24.53 29.45 29.41 18.85 24.25 23.09 28.61 28.57 17.81 22.59 21.55 27.56 27.50 30.65 28.48 29.45 29.41 33.26 30.32 28.14 28.61 28.57 32.82 29.86 27.67 27.56 27.50 115 (46.1) Capacity MBtuh Total Sens 40 (4.4) Capacity MBtuh Total Integ *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1350 / 0.24 1200 / 0.18 1050 / 0.12 CFM / BF EVAPORATOR AIR 36 Cooling Extended Performance Table PERFORMANCE DATA (CONT) 2.96 2.94 2.93 3.09 3.06 3.06 3.23 3.19 3.19 Total Sys KW 30.62 27.98 26.00 27.25 27.22 30.40 27.71 25.72 26.53 26.49 30.05 27.36 25.33 25.62 25.58 42.99 43.06 42.82 42.42 42.62 42.49 41.77 42.15 42.11 42.99 43.06 42.82 42.42 42.62 42.49 41.77 42.15 42.11 60 (15.6) Capacity MBtuh Total Integ 18.76 24.63 23.34 27.25 27.22 17.82 23.14 21.97 26.53 26.49 16.85 21.54 20.50 25.62 25.58 125 (51.7) Capacity MBtuh Total Sens 3.16 3.12 3.10 3.31 3.25 3.24 3.46 3.40 3.38 Total Sys KW 4.22 4.20 4.18 4.19 4.19 4.17 4.15 4.13 4.14 4.14 4.12 4.10 4.08 4.08 4.08 Total Sys KW 14 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EWB _F (_C) 38.29 35.26 28.70 29.99 24.52 40.11 37.93 30.65 32.09 25.87 41.67 41.78 32.53 34.11 27.12 38.29 39.60 40.17 43.43 47.71 40.11 40.77 41.23 44.54 48.87 41.67 41.78 42.07 45.42 49.79 75 (23.9) Capacity MBtuh Total Sens 2.95 2.87 2.83 2.82 2.82 2.89 2.82 2.77 2.77 2.76 2.83 2.76 2.72 2.71 2.70 Total Sys KW 47.20 43.10 39.93 40.00 39.92 46.39 42.33 39.19 38.83 38.48 45.36 41.34 38.23 37.74 36.78 26.14 33.11 31.53 40.00 39.92 24.92 31.12 29.70 36.81 38.48 23.64 29.07 27.80 34.27 36.78 85 (29.4) Capacity MBtuh Total Sens 3.26 3.18 3.13 3.13 3.13 3.20 3.12 3.07 3.07 3.06 3.14 3.07 3.02 3.01 3.00 Total Sys KW 44.53 40.66 37.70 38.10 38.04 43.82 40.00 37.04 36.82 36.73 42.91 39.13 36.20 35.79 35.17 25.11 32.04 30.48 38.10 38.04 23.93 30.10 28.70 36.82 36.73 22.69 28.10 26.84 33.19 35.17 3.62 3.53 3.48 3.49 3.48 3.56 3.48 3.42 3.42 3.42 3.50 3.42 3.37 3.36 3.35 41.74 38.14 35.35 36.09 36.04 41.13 37.55 34.77 34.91 34.85 40.34 36.80 34.04 33.74 33.43 24.03 30.89 29.35 36.09 36.04 22.89 29.02 27.63 34.91 34.85 21.70 27.07 25.81 32.00 33.43 38.81 4.04 75 70 65 EDB _F (_C) 1225 1400 1575 1225 1400 1575 1225 1400 1575 CFM INDOOR AIR 13.54 13.72 13.88 13.21 13.40 13.57 12.79 12.99 13.17 12.46 12.62 12.77 12.15 12.33 12.48 11.77 11.95 12.12 2.47 2.48 2.50 2.61 2.62 2.64 2.75 2.76 2.79 --- 10 (--- 23.3) Capacity Total MBtuh Sys KW Total Integ 17.47 17.68 17.85 17.11 17.33 17.52 16.70 16.93 17.13 16.08 16.26 16.43 15.75 15.95 16.12 15.37 15.58 15.76 0 (--- 17.8) Capacity MBtuh Total Integ 2.63 2.64 2.65 2.77 2.78 2.79 2.91 2.92 2.93 Total Sys KW 21.96 22.14 22.30 21.74 21.94 22.13 21.03 21.59 21.86 20.15 20.32 20.47 19.96 20.14 20.31 19.31 19.82 20.07 10 (--- 12.2) Capacity MBtuh Total Integ 2.78 2.77 2.78 2.92 2.91 2.92 3.05 3.05 3.06 Total Sys KW 42 Heating Extended Performance Table --10--60 (--23.3--15.6_C) 25.98 26.21 26.41 25.70 25.93 26.14 25.41 25.64 25.85 23.56 23.77 23.95 23.30 23.52 23.71 23.05 23.25 23.44 2.88 2.86 2.86 3.02 3.00 3.00 3.17 3.15 3.15 30.54 30.85 31.10 30.15 30.45 30.72 29.76 30.06 30.31 26.76 27.03 27.25 26.42 26.68 26.91 26.07 26.34 26.56 2.98 2.95 2.95 3.12 3.10 3.09 3.27 3.24 3.23 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (--- 6.7) 30 (--- 1.1) Capacity Capacity Total Total MBtuh MBtuh Sys Sys KW KW Total Integ Total Integ 35.78 36.18 36.50 35.27 35.67 35.97 34.76 35.15 35.46 35.78 36.18 36.50 35.27 35.67 35.97 34.76 35.15 35.46 40 (4.4) Capacity MBtuh Total Integ 3.11 3.07 3.07 3.25 3.22 3.21 3.41 3.37 3.35 Total Sys KW 35.47 32.87 33.94 33.89 38.30 34.97 32.38 32.88 32.83 37.63 34.33 31.75 31.62 31.55 4.53 4.43 4.35 4.38 4.38 4.46 4.37 4.29 4.31 4.31 4.40 4.30 4.24 4.24 4.23 Total Sys KW 42.01 42.43 42.12 41.37 41.86 41.84 40.75 41.24 41.48 42.01 42.43 42.12 41.37 41.86 41.84 40.75 41.24 41.48 50 (10) Capacity MBtuh Total Integ 22.90 29.68 28.13 33.94 33.89 21.80 27.89 26.48 32.88 32.83 20.65 25.98 24.73 31.62 31.55 115 (46.1) Capacity MBtuh Total Sens 3.95 3.88 3.90 3.90 3.98 3.89 3.83 3.83 3.83 3.91 3.83 3.77 3.76 3.76 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1575 / 0.19 1400 / 0.17 1225 / 0.14 CFM / BF EVAPORATOR AIR 42 Cooling Extended Performance Table PERFORMANCE DATA (CONT) 50EZ-- A 3.30 3.24 3.22 3.44 3.40 3.37 3.61 3.56 3.53 Total Sys KW 35.71 32.65 30.26 31.61 31.57 35.30 32.23 29.83 30.69 30.65 34.75 31.69 29.30 29.58 29.53 48.77 48.15 47.19 48.32 47.84 47.03 47.80 47.49 46.79 48.77 48.15 47.19 48.32 47.84 47.03 47.80 47.49 46.79 60 (15.6) Capacity MBtuh Total Integ 21.70 28.36 26.81 31.61 31.57 20.64 26.64 25.25 30.69 30.65 19.54 24.82 23.57 29.58 29.53 125 (51.7) Capacity MBtuh Total Sens 3.53 3.46 3.42 3.70 3.62 3.59 3.89 3.80 3.76 Total Sys KW 5.08 4.97 4.89 4.94 4.93 5.02 4.91 4.83 4.86 4.86 4.95 4.85 4.77 4.78 4.78 Total Sys KW 15 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EWB _F (_C) 49.32 49.32 38.00 39.78 31.53 49.85 53.64 58.69 49.16 30.14 49.55 37.49 44.34 48.40 57.75 47.60 47.60 52.75 28.57 56.55 35.87 35.10 48.97 33.66 51.57 41.32 47.12 47.82 45.56 45.56 75 (23.9) Capacity MBtuh Total Sens 3.33 3.32 3.32 3.32 3.32 3.28 3.27 3.27 3.26 3.26 3.23 3.22 3.21 3.21 3.20 Total Sys KW 55.39 50.67 47.12 47.14 47.06 54.58 49.90 46.36 45.91 45.50 53.52 48.88 45.36 44.75 43.64 30.29 38.49 36.74 47.14 47.06 28.93 36.26 34.67 42.93 45.50 27.50 33.93 32.52 40.06 43.64 85 (29.4) Capacity MBtuh Total Sens 3.76 3.73 3.71 3.71 3.71 3.70 3.68 3.65 3.65 3.65 3.64 3.62 3.59 3.59 3.58 Total Sys KW 52.04 47.66 44.35 44.77 44.71 51.36 47.00 43.69 43.41 43.31 50.45 46.13 42.84 42.33 41.62 29.02 37.17 35.44 44.77 44.71 27.71 35.00 33.44 43.41 43.31 26.34 32.74 31.34 38.74 41.62 4.18 4.15 4.11 4.12 4.12 4.13 4.09 4.05 4.05 4.05 4.06 4.02 3.99 3.99 3.98 48.54 44.52 41.47 42.28 42.23 48.01 43.98 40.92 41.04 40.98 47.26 43.25 40.19 39.81 39.47 27.70 35.78 34.07 42.28 42.23 26.44 33.69 32.15 41.04 40.98 25.12 31.49 30.11 37.27 39.47 4.63 4.59 4.55 4.56 4.56 4.57 4.52 4.49 4.49 4.49 4.51 4.46 4.42 4.42 4.41 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW 75 (23.9) 70 (21.1) 65 (18.3) EDB _F (_C) 1400 1600 1800 1400 1600 1800 1400 1600 1800 CFM INDOOR AIR 15.76 16.01 16.24 15.26 15.52 15.76 14.68 14.95 15.19 14.50 14.73 14.94 14.04 14.28 14.50 13.51 13.76 13.98 2.95 2.98 3.02 3.08 3.11 3.15 3.22 3.25 3.29 --- 10 (--- 23.3) Capacity Total MBtuh Sys KW Total Integ 20.36 20.64 20.90 19.85 20.14 20.41 19.29 19.59 19.85 18.74 18.99 19.23 18.27 18.53 18.78 17.74 18.03 18.27 0 (--- 17.8) Capacity MBtuh Total Integ 3.07 3.09 3.12 3.20 3.22 3.25 3.34 3.36 3.39 Total Sys KW 25.22 25.55 25.85 24.68 25.04 25.33 24.12 24.47 24.78 23.15 23.46 23.73 22.65 22.98 23.25 22.14 22.46 22.74 10 (--- 12.2) Capacity MBtuh Total Integ 3.20 3.21 3.23 3.33 3.34 3.36 3.47 3.48 3.51 Total Sys KW 48 Heating Extended Performance Table --10--60 (--23.3--15.6_C) 31.05 31.36 31.63 30.13 30.99 31.28 29.34 29.76 30.19 28.16 28.44 28.69 27.32 28.11 28.37 26.61 26.99 27.38 3.36 3.35 3.37 3.48 3.50 3.51 3.63 3.62 3.63 36.22 36.59 36.92 35.80 36.16 36.49 35.38 35.73 36.07 31.73 32.06 32.35 31.37 31.68 31.97 31.00 31.31 31.60 3.50 3.48 3.48 3.65 3.63 3.63 3.82 3.79 3.79 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (--- 6.7) 30 (--- 1.1) Capacity Capacity Total Total MBtuh MBtuh Sys Sys KW KW Total Integ Total Integ 41.94 42.42 42.84 41.40 41.87 42.28 40.85 41.31 41.72 3.65 3.61 3.60 3.81 3.78 3.76 3.98 3.94 3.93 50EZ-- A 41.94 42.42 42.84 41.40 41.87 42.28 40.85 41.31 41.72 5.12 5.07 5.03 5.05 5.05 5.06 5.01 4.97 4.98 4.98 4.99 4.95 4.91 4.91 4.90 Total Sys KW 48.55 49.17 49.72 47.87 48.48 49.01 47.21 47.80 48.30 48.55 49.17 49.72 47.87 48.48 49.01 47.21 47.80 48.30 50 (10) Capacity MBtuh Total Integ 26.31 44.88 Total Sys KW 34.28 32.60 39.60 39.55 25.09 32.28 30.76 38.53 38.48 23.83 30.17 28.81 37.23 37.15 41.22 38.44 39.60 39.55 44.45 40.79 37.98 38.53 38.48 43.85 40.21 37.38 37.23 37.15 115 (46.1) Capacity MBtuh Total Sens 40 (4.4) Capacity MBtuh Total Integ *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 1800 / 0.21 1600 / 0.18 1400 / 0.15 CFM / BF EVAPORATOR AIR 48 Cooling Extended Performance Table PERFORMANCE DATA (CONT) 3.83 3.77 3.74 4.00 3.94 3.91 4.18 4.12 4.09 Total Sys KW 41.06 37.75 35.24 36.70 36.65 40.74 37.41 34.88 35.81 35.76 40.27 36.94 34.39 34.69 34.64 56.41 57.12 57.48 55.58 56.38 56.82 54.77 55.56 56.12 56.41 57.12 57.48 55.58 56.38 56.82 54.77 55.56 56.12 60 (15.6) Capacity MBtuh Total Integ 24.85 32.65 30.98 36.70 36.65 23.69 30.77 29.27 35.81 35.76 22.48 28.75 27.41 34.69 34.64 125 (51.7) Capacity MBtuh Total Sens 4.05 3.95 3.90 4.24 4.15 4.09 4.43 4.35 4.28 Total Sys KW 5.65 5.60 5.57 5.59 5.59 5.59 5.55 5.52 5.53 5.53 5.53 5.49 5.46 5.46 5.46 Total Sys KW 16 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (13.9) EWB _F (_C) 47.50 49.74 39.07 71.73 60.95 60.95 65.61 60.87 60.87 61.07 35.83 69.68 52.61 58.33 44.47 56.94 56.94 63.63 35.42 69.39 42.62 43.86 63.34 59.07 42.05 51.82 58.00 58.78 56.42 56.42 75 (23.9) Capacity MBtuh Total Sens 4.33 4.25 4.19 4.19 4.19 4.15 4.08 4.02 4.01 3.99 4.13 4.05 4.00 3.99 3.97 Total Sys KW 67.82 62.14 57.83 58.23 58.14 66.07 60.42 56.12 55.44 54.57 65.81 60.17 55.87 55.15 54.09 37.60 48.23 46.01 58.23 58.14 34.51 43.08 41.24 51.08 54.57 34.15 42.48 40.69 50.34 54.09 85 (29.4) Capacity MBtuh Total Sens 4.75 4.67 4.61 4.61 4.61 4.57 4.49 4.43 4.42 4.41 4.55 4.47 4.41 4.40 4.39 Total Sys KW 63.70 58.42 54.45 55.31 55.23 62.25 57.00 53.00 52.47 52.03 62.02 56.78 52.77 52.19 51.60 36.05 46.60 44.43 55.31 55.23 33.07 41.60 39.80 49.35 52.03 32.72 41.02 39.25 48.67 51.60 5.21 5.13 5.07 5.08 5.08 5.04 4.96 4.90 4.89 4.88 5.02 4.94 4.88 4.87 4.86 59.34 54.47 50.81 52.12 52.05 58.17 53.31 49.63 49.36 49.27 57.99 53.14 49.45 49.10 48.89 34.41 44.84 42.69 52.12 52.05 31.52 40.02 38.25 49.36 49.27 31.19 39.45 37.72 48.72 48.89 5.74 5.66 5.60 5.62 5.62 5.56 5.48 5.42 5.42 5.42 5.54 5.46 5.41 5.40 5.40 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity MBtuh Capacity MBtuh Total Total Total Sens Total Sens Sys KW Sys KW 75 70 65 EDB _F (_C) 1750 1800 2250 1750 1800 2250 1750 1800 2250 CFM INDOOR AIR 19.26 19.34 20.06 18.37 18.45 19.15 17.44 17.52 18.19 17.72 17.79 18.45 16.90 16.97 17.62 16.04 16.12 16.73 3.62 3.63 3.75 3.77 3.78 3.90 3.93 3.94 4.06 --- 10 (--- 23.3) Capacity Total MBtuh Sys KW Total Integ 24.88 24.98 25.74 24.01 24.11 24.92 23.12 23.22 23.99 22.89 22.98 23.69 22.09 22.18 22.93 21.27 21.36 22.07 0 (--- 17.8) Capacity MBtuh Total Integ 3.77 3.78 3.88 3.92 3.93 4.04 4.09 4.10 4.21 Total Sys KW 30.79 30.90 31.75 30.00 30.11 30.96 29.18 29.28 30.13 28.26 28.37 29.14 27.54 27.64 28.41 26.78 26.88 27.65 10 (--- 12.2) Capacity MBtuh Total Integ 3.91 3.92 4.00 4.08 4.09 4.17 4.26 4.27 4.35 Total Sys KW 60 Heating Extended Performance Table --10--60 (--23.3--15.6_C) 37.20 37.33 38.31 36.36 36.49 37.44 35.57 35.70 36.62 33.74 33.85 34.75 32.98 33.09 33.95 32.26 32.37 33.21 4.06 4.07 4.12 4.24 4.24 4.30 4.43 4.43 4.48 44.98 45.09 45.93 44.47 44.58 45.42 43.08 43.34 44.87 39.41 39.50 40.25 38.96 39.06 39.80 37.74 37.97 39.31 4.26 4.26 4.28 4.46 4.45 4.47 4.63 4.64 4.68 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 20 (--- 6.7) 30 (--- 1.1) Capacity Capacity Total Total MBtuh MBtuh Sys Sys KW KW Total Integ Total Integ 51.96 52.09 53.12 51.32 51.43 52.45 50.66 50.78 51.79 51.96 52.09 53.12 51.32 51.43 52.45 50.66 50.78 51.79 4.43 4.42 4.41 4.63 4.63 4.61 4.85 4.84 4.82 6.32 6.25 6.19 6.22 6.22 6.15 6.08 6.03 6.03 6.03 6.13 6.06 6.01 6.01 6.01 Total Sys KW 60.02 60.19 61.48 59.22 59.39 60.65 58.44 58.60 59.83 60.02 60.19 61.48 59.22 59.39 60.65 58.44 58.60 59.83 50 (10) Capacity MBtuh Total Integ 32.67 54.72 Total Sys KW 42.93 40.79 48.67 48.61 29.88 38.31 36.56 46.30 46.23 29.56 37.77 36.06 45.94 45.87 50.28 46.95 48.67 48.61 53.84 49.37 45.98 46.30 46.23 53.69 49.23 45.84 45.94 45.87 115 (46.1) Capacity MBtuh Total Sens 40 (4.4) Capacity MBtuh Total Integ *At 75_F (23.9 _C) entering dry bulb—Tennessee Valley Authority [TVA] rating conditions; all others at 80_F (26.7 _C) entering dry bulb. See Legend and Notes. 2250 / 0.27 1850 / 0.20 1750 / 0.19 CFM / BF EVAPORATOR AIR 60 Cooling Extended Performance Table PERFORMANCE DATA (CONT) 50EZ-- A 4.64 4.62 4.58 4.85 4.83 4.79 5.07 5.05 5.00 Total Sys KW 49.88 45.90 42.89 44.93 44.88 49.25 45.20 42.13 42.94 42.88 49.14 45.09 42.01 42.66 42.60 69.62 69.84 71.51 68.63 68.85 70.47 67.67 67.87 69.45 69.62 69.84 71.51 68.63 68.85 70.47 67.67 67.87 69.45 60 (15.6) Capacity MBtuh Total Integ 30.83 40.82 38.69 44.93 44.88 28.16 36.48 34.74 42.94 42.88 27.85 35.96 34.26 42.66 42.60 125 (51.7) Capacity MBtuh Total Sens 4.91 4.89 4.81 5.12 5.10 5.02 5.35 5.33 5.24 Total Sys KW 6.98 6.92 6.87 6.90 6.90 6.82 6.75 6.71 6.72 6.72 6.80 6.74 6.69 6.70 6.70 Total Sys KW 17 = 1.10 x cfm Sensible capacity (Btuh) air leaving evaporator coil (hlwb) Wet---bulb temperature corresponding to enthalpy = tedb --- hlwb = hewb --4.5 x cfm total capacity (Btuh) 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 50EZ-- A 4. The SHC is based on 80_F (26.7 _C) edb temperature of air entering evaporator coil. Below 80_F (26.7_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.7_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb --- 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 4. The SHC is based on 80_F (26.7 _C) edb temperature of air entering evaporator coil. Below 80_F (26.7_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.7_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). Where: hewb = Enthalpy of air entering evaporator coil tlwb tldb LEGEND BF — Bypass Factor edb — Entering Dry ---Bulb Ewb — Entering Wet---Bulb kW — Total Unit Power Input SHC — Sensible Heat Capacity (1000 Btuh) TC — Total Capacity (1000 Btuh) (net) rh —Relative Humidity COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator ---fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: 18 VOLTAGE DISTRIBUTION 200 208 230 240 460 UNIT MOTOR SPEED WIRE COLOR EXTERNAL STATIC PRESSURE (IN. W.C.) 0.1 0.2 0.3 0.4 0.5 0.6 Low Blue CFM 754 650 538 429 --- --- ----- --- --Med---Low Pink CFM 851 777 675 591 475 --- --- --Medium1 Red CFM 941 851 774 684 576 479 50EZ---A24 Med---High Orange CFM 1009 917 840 759 667 577 High Black CFM 1241 1167 1111 1036 969 881 Low Blue CFM 741 638 547 415 --- --- ----- --- --Med---Low Pink CFM 973 887 823 733 665 538 Medium Red CFM 1088 1023 954 881 800 723 50EZ---A30 Med---High1 Orange CFM 1140 1064 996 915 840 758 High Black CFM 1202 1140 1082 1015 961 881 Low Blue CFM 1234 1168 1093 1021 961 894 Med---Low Pink CFM 1290 1223 1154 1090 1027 977 Medium1 Red CFM 1354 1290 1226 1158 1102 1046 50EZ---A36 Med---High Orange CFM 1606 1546 1489 1430 1371 1316 High Black CFM 1630 1580 1517 1463 1407 1339 Low Blue CFM 1295 1234 1182 1126 1075 1016 Med---Low Pink CFM 1345 1282 1235 1194 1140 1095 Medium Red CFM 1505 1452 1413 1358 1323 1282 50EZ---A42 Med---High1 Orange CFM 1545 1492 1449 1411 1362 1313 High Black CFM 1705 1643 1607 1568 1518 1483 Low Blue CFM 1402 1351 1311 1263 1224 1172 Med---Low Pink CFM 1457 1404 1367 1318 1284 1233 Medium1 Red CFM 1736 1695 1642 1601 1553 1512 50EZ---A48 Med---High Orange CFM 2149 2111 2062 2026 1980 1945 High Black CFM 2344 2306 2259 2203 2141 2070 Low Blue CFM 1445 1389 1341 1281 1236 1189 Med---Low Pink CFM 1678 1635 1602 1558 1513 1474 Medium1 Red CFM 1927 1893 1858 1824 1791 1759 50EZ---A60 Med---High Orange CFM 2131 2088 2065 2013 1982 1941 High Black CFM 2461 2409 2339 2286 2192 2140 * Air delivery values are without air filter and are for dry coil (See 50EZ---A Wet Coil Pressure Drop Table). 1 Factory ---shipped cooling speed NOTE: Deduct field---supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed. NOTE: Deduct 10% for 208 volt operation. Dry Coil Air Delivery* -- Horizontal -- Unit 50EZ--A24--60 Series A 480 HEATER kW RATING 240 Multiplication Factors PERFORMANCE DATA (CONT) 50EZ-- A 0.7 --- --- ----- --- ----- --- --447 818 --- --- --451 658 687 810 825 894 981 1258 1277 955 1027 1234 1278 1448 1136 1197 1465 1905 1991 1139 1438 1720 1888 2062 0.8 --- --- ----- --- ----- --- ----- --- --731 --- --- ----- --- --563 564 732 759 828 918 1208 1210 898 974 1169 1231 1404 1080 1144 1427 1864 1902 1072 1404 1689 1860 1968 MULTIPLICATION FACTOR 0.69 0.75 0.92 1.00 0.92 0.9 --- --- ----- --- ----- --- ----- --- --640 --- --- ----- --- --461 480 631 687 762 843 1140 1131 857 921 1130 1188 1360 1041 1104 1381 1793 1803 1027 1349 1640 1785 1874 19 50EZA30 50EZA24 UNIT Blue Pink Low MedLow Black Black High High Orange MedHigh Orange Red Medium1 MedHigh1 Pink MedLow Red Blue Low Medium WIRE COLOR MOTOR SPEED Dry Coil Air Delivery -- Downflow Discharge CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP 0.10 809 85 0.09 875 101 0.11 939 119 0.13 1026 146 0.16 1264 250 0.27 756 84 0.09 1002 144 0.15 1110 188 0.20 1160 213 0.23 1240 254 0.27 0.20 664 82 0.09 787 111 0.12 860 124 0.13 949 151 0.16 1202 261 0.28 669 90 0.10 928 155 0.17 1025 195 0.21 1091 225 0.24 1173 266 0.29 0.30 554 87 0.09 693 115 0.12 748 134 0.14 873 161 0.17 1134 274 0.29 548 96 0.10 842 161 0.17 967 205 0.22 1004 232 0.25 1110 274 0.29 50EZ-- A EXTERNAL STATIC PRESSURE (IN. W.C.) 0.40 0.50 0.60 0.70 447 ---------95 ---------0.10 ---------612 498 392 ---125 131 142 ---0.13 0.14 0.15 ---663 591 472 399 138 147 155 164 0.15 0.16 0.17 0.18 786 694 604 516 167 177 183 195 0.18 0.19 0.20 0.21 1070 1002 931 870 279 290 296 308 0.30 0.31 0.32 0.33 457 ---------106 ---------0.11 ---------733 660 560 450 173 185 192 203 0.19 0.20 0.21 0.22 879 814 706 611 211 223 236 243 0.23 0.24 0.25 0.26 945 866 804 699 243 249 261 273 0.26 0.27 0.28 0.29 1031 966 902 821 284 295 302 315 0.30 0.32 0.32 0.34 0.80 ------------------------------------806 319 0.34 ------------------509 255 0.27 615 285 0.31 726 327 0.35 0.90 ------------------------------------699 328 0.35 ---------------------------496 291 0.31 626 331 0.35 1.0 ------------------------------------610 332 0.36 ---------------------------------------------- 20 50EZA42 50EZA36 UNIT Blue Pink Low MedLow Black Black High High Orange MedHigh Orange Red Medium1 MedHigh1 Pink MedLow Red Blue Low Medium WIRE COLOR MOTOR SPEED Dry Coil Air Delivery -- Downflow Discharge CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP CFM WATTS BHP 0.10 1277 285 0.31 1312 314 0.34 1381 358 0.38 1631 567 0.61 1681 618 0.66 1365 177 0.19 1425 197 0.21 1582 267 0.29 1623 285 0.31 1775 371 0.40 0.20 1215 289 0.31 1260 324 0.35 1326 365 0.39 1579 576 0.62 1633 626 0.67 1324 189 0.20 1384 210 0.23 1549 280 0.30 1586 299 0.32 1736 386 0.41 0.30 1147 299 0.32 1203 329 0.35 1269 375 0.40 1525 581 0.62 1575 636 0.68 1284 201 0.22 1339 223 0.24 1509 294 0.32 1553 312 0.33 1696 401 0.43 EXTERNAL STATIC PRESSURE (IN. W.C.) 0.40 0.50 0.60 0.70 1094 1045 992 932 305 314 319 328 0.33 0.34 0.34 0.35 1153 1095 1050 995 340 344 355 361 0.36 0.37 0.38 0.39 1212 1161 1121 1070 383 391 395 406 0.41 0.42 0.42 0.44 1477 1423 1372 1336 592 598 609 617 0.63 0.64 0.65 0.66 1526 1478 1415 1366 644 652 653 649 0.69 0.70 0.70 0.70 1233 1181 1127 1084 210 222 236 248 0.23 0.24 0.25 0.27 1301 1254 1199 1151 235 248 257 271 0.25 0.27 0.28 0.29 1469 1433 1392 1346 308 322 336 344 0.33 0.35 0.36 0.37 1511 1470 1433 1393 324 335 349 363 0.35 0.36 0.37 0.39 1660 1622 1588 1557 410 424 439 453 0.44 0.45 0.47 0.49 50EZ-- A 0.80 874 335 0.36 943 372 0.40 1019 418 0.45 1284 619 0.66 1312 642 0.69 1039 261 0.28 1104 284 0.30 1300 359 0.38 1350 378 0.41 1516 468 0.50 0.90 826 347 0.37 889 382 0.41 974 424 0.45 1233 613 0.66 1249 627 0.67 984 269 0.29 1065 296 0.32 1249 374 0.40 1309 393 0.42 1472 483 0.52 1.0 757 352 0.38 829 387 0.42 912 434 0.47 1166 598 0.64 1159 602 0.65 939 281 0.30 1015 305 0.33 1213 387 0.42 1261 407 0.44 1426 497 0.53 21 UNIT MOTOR SPEED WIRE COLOR 50EZ-- A EXTERNAL STATIC PRESSURE (IN. W.C.) 0.10 0.20 0.30 0.40 0.50 0.60 0.70 CFM 1503 1457 1423 1374 1330 1287 1241 WATTS 225 233 246 254 269 282 292 Low Blue BHP 0.24 0.25 0.26 0.27 0.29 0.30 0.31 CFM 1556 1508 1461 1432 1388 1346 1302 WATTS 244 261 268 281 290 305 319 MedLow Pink BHP 0.26 0.28 0.29 0.30 0.31 0.33 0.34 CFM 1861 1822 1786 1758 1716 1688 1660 WATTS 400 417 426 441 452 467 482 50EZA48 Medium1 Red BHP 0.43 0.45 0.46 0.47 0.48 0.50 0.52 CFM 2319 2291 2255 2230 2193 2166 2118 WATTS 758 769 787 799 808 823 822 MedHigh Orange BHP 0.81 0.82 0.84 0.86 0.87 0.88 0.88 CFM 2532 2487 2444 2391 2330 2259 2179 WATTS 1014 1022 1015 994 965 935 898 High Black BHP 1.09 1.10 1.09 1.07 1.03 1.00 0.96 CFM 1479 1436 1387 1346 1298 1253 1206 WATTS 224 239 247 262 270 284 300 Low Blue BHP 0.24 0.26 0.26 0.28 0.29 0.30 0.32 CFM 1841 1796 1761 1724 1690 1651 1616 WATTS 425 434 453 460 476 485 501 MedLow Pink BHP 0.46 0.47 0.49 0.49 0.51 0.52 0.54 CFM 2045 2009 1970 1933 1905 1868 1829 WATTS 569 579 597 607 623 639 648 50EZA60 Medium1 Red BHP 0.61 0.62 0.64 0.65 0.67 0.69 0.69 CFM 2178 2148 2105 2073 2036 2002 1967 WATTS 674 691 703 717 733 743 758 MedHigh Orange BHP 0.72 0.74 0.75 0.77 0.79 0.80 0.81 CFM 2480 2432 2375 2322 2236 2161 2085 WATTS 1029 1012 995 975 941 908 869 High Black BHP 1.10 1.09 1.07 1.05 1.01 0.97 0.93 *Air delivery values are without air filter and are for dry coil (See 50EZ Wet Coil Pressure Drop table). 1 Factory--shipped heating speed 2 Factory--shipped cooling speed “NA” = Not allowed for heating speed NOTE: Deduct field--supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting. Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed. Dry Coil Air Delivery -- Downflow Discharge 0.80 1199 307 0.33 1256 330 0.35 1619 492 0.53 2057 805 0.86 2111 858 0.92 1160 307 0.33 1578 508 0.54 1802 665 0.71 1919 754 0.81 2006 836 0.90 0.90 1153 314 0.34 1221 345 0.37 1583 507 0.54 1992 780 0.84 2033 823 0.88 1114 319 0.34 1527 525 0.56 1751 674 0.72 1845 734 0.79 1917 796 0.85 1.0 1111 329 0.35 1168 353 0.38 1539 519 0.56 1887 737 0.79 1949 786 0.84 1061 330 0.35 1478 542 0.58 1683 663 0.71 1751 701 0.75 1808 751 0.81 22 600 0.03 700 0.04 800 0.04 900 0.05 0.05 0.06 1000 0.06 0.06 0.06 0.05 --- 5.0 600-1400 CFM 12x20x1+12x20x1 (305x508x25+305x508x25) 1200-1800 CFM 16x24x1+14x24x1 (406x610x25+356x610x25) 1500-2200 CFM 16x24x1+18x24x1 (406x610x25+457x610x25) FILTER SIZE IN. (MM) --- --- 5.0 0.03 3.5, 4.0 COOLING TONS 2.0, 2.5, 3.0 600 --- --- 600 3.5, 4.0 COOLING TONS 2.0, 2.5, 3.0 Filter Pressure Drop Table (IN. W.C.) 600-1400 CFM 12x20x1+12x20x1 (305x508x25+305x508x25) 1200-1800 CFM 16x24x1+14x24x1 (406x610x25+356x610x25) 1500-2200 CFM 16x24x1+18x24x1 (406x610x25+457x610x25) FILTER SIZE IN. (MM) --- --- 0.05 700 --- --- --- 700 --- --- 0.06 800 --- --- 0.09 800 Economizer with 1--in. Filter Pressure Drop (IN. W.C.) UNIT SIZE 24 30 36 42 48 60 Wet Coil Pressure Drop (IN. W.C.) --- --- 0.08 900 --- --- 0.14 --- --- 0.10 1000 --- --- 0.16 1000 0.08 0.10 0.06 0.04 0.07 0.09 0.05 900 1200 1100 --- --- 0.11 1100 --- --- 0.18 1100 --- 0.07 0.13 1200 --- 0.10 0.25 1200 0.11 0.11 0.07 0.06 0.08 0.10 0.06 0.09 0.10 0.07 1600 0.09 0.11 0.01 1700 --- 0.12 0.3 0.15 0.13 --- 0.17 0.14 --- --- 0.08 0.14 --- 0.09 0.16 0.04 0.09 --- 0.06 0.10 --- STANDARD CFM (SCFM) 1300 1400 1500 1600 --- 0.11 0.28 STANDARD CFM (SCFM) 1300 1400 1500 1600 0.14 0.08 0.09 STANDARD CFM (SCFM) 1300 1400 1500 0.11 0.12 0.08 1800 0.08 0.11 --- 1700 0.18 0.16 --- 1700 50EZ-- A 0.10 0.12 --- 1800 0.20 0.16 --- 1800 0.11 --- --- 1900 0.21 --- --- 1900 0.13 0.09 1900 0.13 --- --- 2000 0.22 --- --- 2000 0.14 0.10 2000 0.14 --- --- 2100 0.23 --- --- 2100 0.12 2100 0.15 --- --- 2200 0.23 --- --- 2200 0.13 2200 23 600 0.00 0.00 0.00 0.00 0.00 700 0.00 0.00 0.00 0.00 0.02 5kw 7.5 kw 10 kw 15 kw 20 kw 1100 0.00 0.00 0.00 0.00 0.02 1200 0.00 0.00 0.00 0.02 0.03 1300 0.00 0.01 0.01 0.03 0.04 Electric Heat Pressure Drop Table (IN. W.C.) Large Cabinet 42--60 5kw 7.5 kw 10 kw 15 kw 20 kw 500 0.00 0.00 0.00 0.00 0.00 Electric Heat Pressure Drop Table (IN. W.C.) Small Cabinet: 24--36 1400 0.01 0.02 0.02 0.04 0.05 1500 0.02 0.03 0.03 0.05 0.06 800 0.00 0.00 0.00 0.02 0.04 1600 0.03 0.04 0.04 0.06 0.07 900 0.00 0.00 0.00 0.04 0.06 STANDARD CFM (SCFM) 1700 1800 0.04 0.05 0.05 0.06 0.05 0.06 0.07 0.08 0.08 0.09 STANDARD CFM (SCFM) 1000 1100 0.00 0.00 0.00 0.02 0.02 0.04 0.06 0.08 0.08 0.09 1900 0.06 0.07 0.07 0.09 0.10 2000 0.07 0.08 0.08 0.10 0.11 1200 0.00 0.03 0.06 0.10 0.11 50EZ-- A 2100 0.08 0.09 0.09 0.11 0.12 1300 0.02 0.05 0.07 0.12 0.13 2200 0.09 0.10 0.10 0.12 0.13 1400 0.04 0.07 0.09 0.14 0.15 2300 0.10 0.11 0.11 0.13 0.14 1500 0.06 0.08 0.10 0.16 0.17 2400 0.11 0.12 0.12 0.14 0.15 2500 0.12 0.13 0.13 0.15 0.16 1600 0.07 0.09 0.11 0.18 0.19 TYPICAL PIPING AND WIRING ROOF-MOUNTING CURB ROOF 50EZ-- A RETURN-AIR FLEXIBLE DUCT SUPPLY-AIR FLEXIBLE DUCT CEILING CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) A09230 INDOOR THERMOSTAT RETURN AIR FROM POWER SOURCE TOP COVER DISCONNECT PER NEC* POWER ENTRY CONTROL ENTRY *NEC - National Electrical Code A09240 24 APPLICATION DATA Condensate trap — A 2--in. (51 mm) condensate trap must be field supplied. Ductwork — Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. To convert a unit to downflow discharge — Units are equipped with factory--installed inserts in the downflow openings. Removal of the inserts is similar to removing an electrical knock--out. Units installed in horizontal discharge orientation do not require duct covers. Maximum cooling airflow — To minimize the possibility of condensate blow--off from the evaporator, airflow through the units should not exceed 450 cfm per ton. Minimum cooling airflow — Minimum cooling airflow is 350 cfm per ton in cooling mode. Airflow can be lower in certain modes when humidity removal is an issue. Minimum ambient cooling operation temperature — All standard units have a minimum ambient cooling operating temperature of 40_F (4.4_C). With accessory low ambient temperature kit, units can operate at temperatures down to 0_F (17.8_C). Maximum operating outdoor air temperature for cooling is 125_F (51.7_C). BALANCE POINT WORKSHEET 70 50EZ-- A 60 BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH 60 48 50 42 36 40 30 30 24 20 10 BASED ON INDOOR ENT. AIR AT 70°F (21.1°C) AND AT RATED CFM 0 -20 (-28.9) -10 (-23.3) 0 (-17.8) 10 (-12.2) 20 (-6.7) 30 (-1.1) 40 (4.4) 50 (10) 60 (15.6) 70 (21.1) OUTDOOR TEMPERATURE, °F (°C) A09269 25 ELECTRICAL DATA UNIT 50EZ-A24---30-- 50EZ-- A 50EZ-A30---30-- 50EZ-A30---50-- 50EZ-A36---30-- 50EZ-A36---50-- 50EZ-A36---60-- 50EZ-A42---30-- 50EZ-A42---50-- 50EZ-A42---60-- 50EZ-A48---30-- 50EZ-A48---50-- 50EZ-A48---60-- NOMINAL V-PH-HZ 208/230-1-60 208/230-1-60 208/230-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 208/230-1-60 208/230-3-60 460-3-60 VOLTAGE RANGE MIN 197 197 197 197 197 414 197 197 414 197 197 414 MAX 253 253 253 253 253 506 253 253 506 253 253 506 COMPRESSOR RLA 13.5 16 10.9 19.3 13 6 20.9 13.5 6.2 23.5 14.8 6.5 LRA 58.3 73 58 79 73 38 112 88 44 117 83.1 41 MCC 20.0 22.0 13.9 26.0 16.3 9.0 28.0 21.1 9.3 34.0 21.4 9.7 OFM IFM FLA FLA 1.2 1.2 1.2 1.2 1.2 0.5 1.2 1.2 0.5 1.2 1.2 0.5 26 4.1 4.1 4.1 6.0 6.0 3.0 6.0 6.0 3.0 7.6 7.6 3.8 ELECTRIC HEAT NOMINAL kW FLA POWER SUPPLY MCA MOCP -/- -/- 22.2 30 3.8/5 18.1/20.8 44.8/48.2 45/50 5.4/7.2 25.9/30 54.6/59.7 60/60 7.5/10 36.1/41.7 67.3/74.3 70/80 -/- -/- 25.3 40 3.8/5 18.1/20.8 47.9/51.3 50/60 5.4/7.2 25.9/30 57.7/62.8 60/70 7.5/10 36.1/41.7 70.4/77.4 80/80 11.3/15 54.2/62.5 93.1/103.4 100/110 -/- -/- 18.9 25 3.8/5 10.4/12 31.9/33.9 35/35 7.5/10 20.8/24.1 44.9/49.1 45/50 11.3/15 31.2/36.1 57.9/64.1 60/70 -/- -/- 31.3 45 3.8/5 18.1/20.8 54/57.3 60/60 5.4/7.2 25.9/30 63.7/68.8 70/70 7.5/10 36.1/41.7 76.5/83.5 80/90 11.3/15 54.2/62.5 99.1/109.5 100/110 -/- -/- 23.5 30 3.8/5 10.4/12 36.5/38.5 40/40 7.5/10 20.8/24.1 49.5/53.6 50/60 11.3/15 31.2/36.1 62.5/68.6 70/70 -/- -/- 11 15 3.8/5 6 18.5/18.5 20 7.5/10 12 26/26 30 11.3/15 18 33.5/33.5 35 -/- -/- 33.3 50 3.8/5 18.1/20.8 56/59.3 60/60 5.4/7.2 25.9/30 65.7/70.8 70/80 7.5/10 36.1/41.7 78.5/85.5 80/90 11.3/15 54.2/62.5 101.1/111.5 110/125 15/20 72.2/83.3 123.6/137.5 125/150 -/- -/- 24.1 35 3.8/5 10.4/12 37.1/39.1 40/40 7.5/10 20.8/24.1 50.1/54.2 60/60 11.3/15 31.2/36.1 63.1/69.2 70/70 15/20 41.4/47.9 75.8/84 80/90 -/- -/- 11.3 15 3.8/5 6 18.8/18.8 20 7.5/10 12 26.3/26.3 30 11.3/15 18 33.8/33.8 35 15/20 24.1 41.4/41.4 45 -/- -/- 38.2 50 3.8/5 18.1/20.8 60.8/64.2 70/70 5.4/7.2 25.9/30 70.6/75.7 80/80 7.5/10 36.1/41.7 83.3/90.3 90/100 11.3/15 54.2/62.5 105.9/116.3 110/125 15/20 72.2/83.3 128.4/142.3 150/150 -/- -/- 27.3 40 3.8/5 10.4/12 40.3/42.3 45/45 7.5/10 20.8/24.1 53.3/57.4 60/60 11.3/15 31.2/36.1 66.3/72.4 70/80 15/19.91 41.4/47.9 79.1/87.2 80/90 -/- -/- 12.4 15 3.8/5 6 19.9/19.9 20 7.5/10 12 27.4/27.4 30 11.3/15 18 34.9/34.9 35 15/20 24.1 42.6/42.6 45 ELECTRICAL DATA (CONT) 50EZ-A60---30-- 50EZ-A60---50-- 50EZ-A60---60-- NOMINAL V-PH-HZ 208/230-1-60 208/230-3-60 460-3-60 VOLTAGE RANGE MIN 197 197 414 MAX 253 253 506 COMPRESSOR RLA 27.4 18.4 8 LRA 134 110 52 MCC 41.2 24.9 12.1 OFM IFM FLA FLA 1.2 1.2 0.5 7.6 7.6 3.8 ELECTRIC HEAT NOMINAL kW FLA POWER SUPPLY MCA MOCP -/- -/- 43.1 60 3.8/5 18.1/20.8 65.7/69.1 70/70 5.4/7.2 25.9/30 75.4/80.6 80/90 7.5/10 36.1/41.7 88.2/95.2 90/100 11.3/15 54.2/62.5 110.8/121.2 125/125 15/20 72.2/83.3 133.3/147.2 150/150 -/- -/- 31.8 45 3.8/5 10.4/12 44.8/46.8 45/50 60/70 7.5/10 20.8/24.1 57.8/61.9 11.3/15 31.2/36.1 70.8/76.9 80/80 15/19.91 41.4/47.9 83.6/91.7 90/100 -/- -/- 14.3 20 3.8/5 6 21.8/21.8 25 7.5/10 12 29.3/29.3 30 11.3/15 18 36.8/36.8 40 15/20 24.1 44.4/44.4 45 See Legend and Notes below. A06564 27 50EZ-- A UNIT 50EZ-- A CONNECTION WIRING SCHEMATICS 208/230--1--60 A11002 28 50EZ-- A LADDER WIRING SCHEMATICS 208/230--1--60 A11001 29 50EZ-- A CONNECTION WIRING SCHEMATICS - 208/230--3--60 A11006 30 50EZ-- A LADDER WIRING SCHEMATICS - 208/230--3--60 A11005 31 50EZ-- A CONNECTION WIRING DIAGRAM 460--3--60 A10195 32 50EZ-- A LADDER WIRING DIAGRAM 460--3--60 33 CONTROLS 50EZ-- A Operating sequence When power is supplied to unit, the transformer (TRAN) is energized. On units with crankcase heater, heater is also energized. Cooling — With the thermostat in the cooling position, the thermostat makes circuit “R” to “O”. This energizes the reversing valve solenoid (RVS) and places the unit in standby condition for cooling. As the space temperature rises, the thermostat closes circuit “R” to “Y”. A circuit is made to contactor (C), starting the compressor (COMP) and outdoor--fan motor (OFM). Circuit “R” to “G” is made at the same time and starts the indoor--fan motor (IFM). When the thermostat is satisfied, contacts open, deenergizing C. The COMP and OFM stop, and the IFM stops after the preselected time delay. On the loss of the thermostat call for cooling, 24 V is removed from both the “Y1/Y” and “G” terminals (provided the fan switch is in the “AUTO” position) de--energizing the compressor contactor and opening the contacts supplying power to compressor/OFM. After a 90--second delay, the IFM shuts off. If the thermostat fan selector switch is in the “ON” position, the IFM will run continuously. Heating — On a call for heat, thermostat makes circuits “R” to “Y) and “R” to “G”. A circuit is made to C, starting COMP and OFM. Circuit “R” to “G” also is completed, energizing IFR and starting IFM after the selected time delay. Should room temperature continue to fall, circuit “R” to “W” is made through second--stage thermostat. If optional electric heat package is used, a relay is energized, bringing on first bank of supplemental electric heat. When thermostat is satisfied, contacts open, deenergizing contactor and relay; motors and heaters deenergize. Defrost — Defrost board (DB) is a time and temperature control, which includes a field--selectable time period (dip switch 1 and 2 on the board) between checks for defrost (30, 60, 90, or 120 minutes). Electronic timer and defrost cycle start only when contactor is energized and defrost thermostat (DFT) is closed. The defrost board is also equipped with a third dip switch for selecting Quiet Shift operation. The Quiet Shift operation turns compressor off at defrost initiation and termination. Unit is factory shipped with quiet shift turned off. Defrost mode is identical to cooling mode, except outdoor fan motor stops and a bank of optional electric heat turns on to warm air supplying the conditioned space. NOTE: 1. Compressor time delay occurs through the defrost control board. 2. Defrost control board has built in 5 minute compressor delay; once the compressor has started and then stopped, it cannot be restarted again until 5 minutes have elapsed. 34 Packaged Heat Pumps HVAC Guide Specifications Size Range: 2 to 5 Tons, Nominal Cooling Carrier Model Number: 50EZ--A Part 1General SYSTEM DESCRIPTION Outdoor, packaged, air--to--air heat pump unit utilizing a hermetic scroll compressor for cooling duty and optional electric heating. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. Outdoor fan/coil section shall have a draw--thru design with vertical discharge for minimum sound levels. corrosion resistant finish. Fan wheel shall be dynamically balanced. 3. Outdoor fan shall be direct--drive, propeller--type with aluminum blades riveted to corrosion resistant steel spiders, be dynamically balanced, and discharge air vertically. D. Compressor: 1. Fully hermetic compressors with factory--installed vibration isolation. 2. Scroll compressors shall be standard on all units. 3. Compressor Protection: Defrost control shall protect compressor by preventing “short cycling.” E. Coils: Indoor and outdoor coils shall have aluminum plate fins mechanically bonded to seamless copper tubes with all joints brazed. (Copper/copper and vinyl--coated construction available as option.) Tube sheet openings shall be belled to prevent tube wear. QUALITY ASSURANCE A. Unit shall be rated in accordance with AHRI Standards 210/240 and 270. B. Unit shall be designed in accordance with UL Standard 1995. C. Unit shall be manufactured in a facility registered to ISO 9001 manufacturing quality standard. D. Unit shall be UL listed and c--UL certified as a total package for safety requirements. E. Roof curb shall be designed to conform to NRCA Standards. F. Insulation and adhesives shall meet NFPA 90A requirements for flame spread and smoke generation. G. Cabinet insulation shall meet ASHRAE Standard 62P. DELIVERY, STORAGE AND HANDLING Unit shall be stored and handled per manufacturer’s recommendations. Part 2  Products EQUIPMENT A. General: Factory--assembled, single--piece, heat pump unit. Contained within the enclosure shall be all factory wiring, piping, controls, refrigerant charge (R--410A), and special features required prior to field start--up. B. Unit Cabinet: 1. Unit cabinet shall be constructed of phosphated, zinc--coated, pre--painted steel capable of withstanding 500 hours of salt spray. 2. Normal service shall be through a single removable cabinet panel. 3. The unit shall be constructed on a rust proof unit base that has an externally trapped, integrated sloped drain. 4. Indoor fan compartment top surface shall be insulated with a minimum 1/2--in. (12.7 mm) thick, flexible fiberglass insulation, coated on the air side and retained by adhesive and mechanical means. The indoor wall sections will be insulated with a minimum semi--rigid, foil--faced board capable of being wiped clean. Aluminum foil--faced fiberglass insulation shall be used in the entire indoor air cavity section. 5. Unit shall have a field--supplied condensate trap. 6. Metal Insulated Duct Covers for side discharge will be standard on all sizes. 7. Unit insulation conforms to ASHRAE 62P. C. Fans: 1. The indoor fan shall be 5--speed, direct--drive, as shown on equipment drawings. 2. Fan wheel shall be made from steel and shall be double--inlet type with forward--curved blades with F. Refrigerant Metering Device: Refrigerant metering device shall be thermostatic expansion valve for cooling, and fixed orifice for heating. G. Filters: Filter section shall consist of field--installed, throwaway, 1--in. (25 mm) -- thick fiberglass filters of commercially available sizes. H. Controls and Safeties: 1. Unit controls shall be complete with a self--contained, low-voltage control circuit. 2. Units shall incorporate an internal compressor protector that provides reset capability. I. Operating Characteristics: 1. Unit shall be capable of starting and running at 125_F (51.7_C) ambient outdoor temperature. 2. Compressor with standard controls shall be capable of operation down to 40_F (4.4_C) ambient outdoor temperature in cooling mode. 3. Unit shall be provided with 60--second fan time delay after the thermostat is satisfied. J. Electrical Requirements: All unit power wiring shall enter the unit cabinet at a single location. K. Motors: 1. Compressor motors shall be of the refrigerant--cooled type with line--break thermal and current overload protection. 2. All fan motors shall have permanently lubricated bearings, and inherent, automatic reset, thermal overload protection. 3. Condenser fan motor shall be totally enclosed. 4. Evaporator Fan Motor to be ECM Motor. 5. Condenser fan motor shall be totally enclosed. L. Special Features Available: 1. Coil Options: Base unit with tin plated indoor coil hairpins. 2. Compressor Start Kit (single phase units only) Shall provide additional starting torque for single--phase compressors. 3. Thermostat: To provide for two--stage heating and one--stage cooling in addition manual or automatic changeover and indoor fan control. 4. Crankcase Heater: Shall provide anti--floodback protection for lowload cooling applications. 35 50EZ-- A GUIDE SPECIFICATIONS 50EZ-- A GUIDE SPECIFICATIONS (CONT) 5. Economizer: a. Economizer controls capable of providing free cooling using outside air. b. Equipped with low leakage dampers not to exceed 3% leakage, at 1.0 in. W.C. pressure differential. c. Spring return motor shuts off outdoor damper on power failure. 6. Electric Heaters: a. Electric heater shall be available as a field installed option. b. Heater elements shall be open wire type, adequately supported and insulated with ceramic bushings. c. Electric heater packages must provide single point power connection capability. 7. Filter Rack Kit: Shall provide filter mounting for downflow applications. 8. Flat Roof Curb: Curbs shall have seal strip and a wood nailer for flashing and shall be installed per manufacturer’s instructions. 9. Low Ambient Package: Shall consist of a solid--state control and outdoor coil temperature sensor for controlling outdoor--fan motor opera- Copyright 2011 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. 10. 11. 12. 13. 14. tion, which shall allow unit to operate down to 0_F (--17.7_C) outdoor ambient temperature. Louvered Grille: Wire grille shall be standard on all units. Louvered grille shall be available as a field--installed option to provide hail guard and vandalism protection. Manual Outdoor Air Damper: Package shall consist of damper, birdscreen, and rainhood which can be preset to admit outdoor air for year--round ventilation. Square--To--Round Duct Transitions (24--48 size): Shall have the ability to convert the supply and return openings from rectangular to round. Time Guard II Automatically prevents the compressor from restarting for at least 4 minutes and 45 seconds after shutdown of the compressor. Not required when a corporate programmable thermostat is applied or with a RTU--MP control. Dual Point Electric Heaters Allows you to power the electric heater and unit contactor separately by having two individual field power supply circuits connected respectively. Edition Date: 08/11 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 36 Catalog No:50EZ---06PD Replaces: 50EZ--- 05PD