Transcript
Manson
PV CHARGE CONTROLLER SBL - 2108 / 2208 Sealed Low Power Charge Controller
Manson
LEAD ACID BATTERY CHARGER HBC - 3205 / 3210 24V Advanced Multi-Stage Battery Charger with MCU
Specifications Model AC Input Voltage 100 - 240VAC, 50/60Hz~ AC Input Current at Full Load (at 230 / 100 AC) Output (Charge) Voltage Selections
Description This series of cost effective PV Charge Controller is designed for trouble free application in coarse, high humid and large change of ambient temperature environment. The whole PCB assembly is potted with epoxy and enclosed in a poly-carbonate casing.
Features • • •
MCU controlled program PWM charging Selection of Sealed & Wet Type battery Electronic protections (self -recoverable) for : • Controller Over Temperature • Reverse Polarity for battery connection. • Over Load & Short Circuit • Over Voltage Protection to battery at 16V of (SBL-2108) and 32V of (SBL-2208) • Water resistant and wide operation temperature range (-40°C to +60°C) • Night Light Mode with Dusk to Dawn lighting operation with battery over discharge protection • Low standby current less than 9mA • CE approval
A microprocessor (MCU) is used to control the PWM charging in Absorption Stage and Float charge to recycle charging. The charging profile of Bulk, Absorption and Float are especially programmed for the opportunity charging condition for solar charge application. The MCU controls the Over Temperature Protection, Over Load Protection of the unit, Reverse Polarity Protection of connections to both the solar panel and battery. The protections are normally self recoverable when the fault has been cleared and operating condition returns to normal condition. However repeated triggering of Overload or Short Circuit will call for user intervention and reset the controller. Selection for Sealed type and Wet type of battery, Night Light Mode load connection for dusk to dawn lighting application with low voltage cut off protection for the battery are standard features of this intelligent solar charge controller .
Specifications Models Battery System Voltage Max. PV Open Circuit Voltage Max. PV Short Circuit Current Rated PV Input Current Max. PV Input Current (5 minutes) Rated Load Current Max. Load Current (5 minutes) Min. Operating Charging Voltage (from Battery) Standby Current Consumption PV Voltage to Turn on the Night Light Mode Load PV Voltage to Turn off the Night Light Mode Load Protections Over Temperature Protection to shut down unit Over Voltage Protection for Battery Battery Low Voltage to disconnect load Battery Low Voltage to Auto-reconnect load Over Current for Load 12A Battery Terminal Reverse Polarity Protection Absorption Voltage Sealed Type Battery Setting Wet Type Battery Setting Float Voltage Ambient Temperature Range Relative Humidity Approvals Dimensions (WxHxD) Weight
SBL - 2108 12VDC 26VDC 10A 8A 10A 8A 10A 6VDC ≤9mA ≤3V for 10minutes ≥3.5V for 10minutes
SBL - 2208 24VDC 52VDC 10A 8A 10A 8A 10A 9.5VDC ≤9mA ≤6V for 10minutes ≥7V for 10minutes
Yes and Self recoverable 16VDC Self recoverable ≤11.5V ±0.2V ≥12.4V ±0.2V
Yes and Self recoverable 32VDC Self recoverable ≤23.0V ±0.4V ≥24.8V ±0.4V
User reset required after 2times recovers
User reset required after 2times recovers
Yes and Self recoverable
Yes and Self recoverable
WET LiFePO4 AGM GEL 1 GEL 2 CALCIUM User Define 1 User Define 2 Equalization Maximum Output Charging Current (continuous) Soft Start Bulk Charge Battery Voltage to Trigger (cut-in) Soft Start Bulk Charge Mode Soft Start Bulk Charge Current Level (current limit) Ripple & Noise (Peak to Peak) Efficiency at WET (230VAC) Dual Banks (Outputs) Simultaneously Charging two Batteries (The two batteries must be of same chemistry, construction & type) Protections Short Circuit Protection Overload Protection Reverse Polarity Protection (fused) Over Temperature Protection OVP (Output Tracking/ Fixed Over Voltage Protection Selectable) Thermal decrease of charger output power Thermostatically Controlled Variable Speed Fan (0 - full speed) Approvals Charge Cycle, Protection Indication Separate LED for Bulk, Absorption, Float and Fault Mode Charger ON / OFF LED Indicator Power ON / OFF Switch Remote Control & Temperature Sensor Socket Plastic panel & Electro-galvanized steel housing w/Mounting flange
Dimension (WxHxD) Weight Included Accessories (spare fuse, temperature sensor) Optional Accessories (remote control panel) Recommended Battery Capacity Range
HBC - 3205 Yes 1A / 2A
HBC - 3210 Yes 2A / 4A
Absorption 28.8V 29.2V 28.6V 28.2V 28.6V 30.2V 24V - 32V 24V - 32V 31V 5A
Float 27.0V 27.2V 26.4V 27.4V 27.6V 27.6V
<24.6V 1/2 of the charging current <200mV >79% Yes
Yes Yes Yes Yes Yes Yes Yes CE
EN 60335
EN 55014
>83% Yes
Yes Yes Yes Yes Yes Yes Yes EN 62233
Yes Yes Yes Yes Yes 200x80x250 mm 2.5 kg
Yes Yes Yes Yes Yes 200x80x250 mm 2.6 kg
Yes Not Included 8AH to 50AH
Yes Not Included 16AH to 100AH
◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
14.5V ±0.2V 29.0V ±0.4V 14.8V ±0.2V 29.6V ±0.4V 13.8V ±0.2V 27.6V ±0.4V -40°C ~ +60°C -40°C ~ +60°C 100% 100% CE EN 61000, FCC Part15 Subpart B Class B 97x46x26 mm 125g
◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
10A