Preview only show first 10 pages with watermark. For full document please download

524d02fbe3613

   EMBED


Share

Transcript

Manson LEAD ACID BATTERY CHARGER SBC - 2110 / 2115 / 2120 12V 3-Stage IUoU Battery Charger with Power Supply Mode Selection LEAD ACID BATTERY CHARGER Manson SBC - 8268 24V 2.2A Smart Battery Charger using Micro Processor control unit with pulse width modulation charge technology Accessories: A battery Charger with lead terminals Detachable leads with crocodile clips Connecting leads with ring teminals Features • • • Microprocessor Control (MCU) 4 Stage Charging (Repair, Bulk, Absorption, Float) in Pulse Width Modulation PWM method. MCU monitors the battery condition from initial qualifying checks, repair, to absorption to float charges. No worries of over or under charging battery, charger can be connected permanently to battery. Auto pulse repair charge for deeply depleted battery. Suitable for all types of Wet, Gel, AGM lead acid battery from 8 to 60 AH. Thermal control regulates charging current in hot or enclosed conditions. Two swappable leads with clamps and eyelet terminal. Simple 3 selection key with intuitive iconic LED indicators. Universal AC input 100V to 240V Description Features • • This series of 3 Stage chargers have 3 specific settings for Wet, Cal-Cal, AGM & GEL type battery to ensure fast, complete and safe charging of your battery as required by the manufacturers. • 3 Stage (IUoU) switching mode lead acid battery charger • • 3 Battery Type (Wet/ Cal-Cal/ AGM & GEL) selections • 3 Float Voltage Settings (13.2/13.5/13.8V) selections Soft Start Bulk Charge an pre-bulk charge for drained out battery. • Battery can be connected to charger permanently Safety • Power Supply/Charger Mode selection The power supply mode is ideal to charge battery with load and keeps battery fully charged • Automatic Soft Start Bulk Charge to ensure a safe and gentle initial charging for deeply drained battery • Temperature compensation with optional remote sensor to prevent over and under charging battery at high and low ambient battery ambient temperature. The charger only starts charging when it is connected to a battery. So there is no spark in contact with battery terminals. Reverse Polarity and Short Circuit protections are by electronics with flashing LED and charger will return to normal when the fault is cleared. A total time for Bulk and Absorption charge is limited to 40 hours to avoid over charging and waste of energy. Therefore it is not suitable for application of charging battery connected to external load connected. The charger is splash proof as its casing is sealed by ultra sonic. It is convection cooled and has thermal regulation to lower the charging current until the unit's temperature drops to an acceptable level. In the event of persistent rising temperature the charger will shut down its output at a preset maximum temperature. • Dual LED indicators for Bulk, Absorption, Float charge stage ; Fault, Power/Charger Mode and Power On. • Power On-Off Switch • Silent fan cool operation -- The thermal control cooling fan with variable speed moves when ambient temperature of charger exceeds 40°C. • Protections to the charger Short circuit, Over Load, Over temperature • Reversed Polarity (thermal fused) • Protection to the battery and load OVP The charger will keep output voltage less than 17.5V to prevent damage to the battery and load. The charger gives 50% of full constant current charge when it detects the battery is over depleted at less than 9V terminal voltage. When battery voltage rises to 11V the charger will resume the normal constant full current Bulk, constant voltage Absorption and Float charge stages. In the Power Supply mode, the charger provides a constant voltage dc power to the external load connected to the battery and at the same time without over charging the battery. This is ideal for caravan and other battery backup applications. The Power Supply Mode output voltage is the selected Float Voltage. The optional temperature sensor adjusts the charging voltages with the changes in ambient temperatures of the battery. This effectively prevents over and under charging the battery in hot summer days to cold wintry nights. Only the 10Amp SBC-2110 model has convection cooling and one charging bank, others have thermal control fan cooling (zero to full speed) and dual charging banks. The Over Voltage protection, in the case of component failure causing uncontrolled high voltage at the output, the charger will limit the voltage less than 17.5V to prevent damage to the battery and connected load. ◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE • • • Introduction This is a simple to use intelligent battery charger with the latest PWM charging technology controlled by a powerful Micro-Processor Control Unit. It is suitable for all types of lead acid batteries from 8AH to 60AH. Operation The Smart Charger runs its own self-tests when connected to an AC source of (100 to 240V). There are 3 Charge Modes to be selected: Sealed Lead Acid / Wet / CalciumCalcium charge. Checks faulty battery The Smart Charger will scan the battery by injecting short DC pulses. If the battery is found faulty, the LED flashes until the faulty battery is disconnected. 3 Stage charging with Repair Charging When the battery is found to be chargeable, the battery will go through constant current Bulk Charge, then a Pulse Width Absorption Charge, and finally a Pulse Float Charge. The charger can be connected to battery permanently without over charge. Repair charging If the battery is found to be sulphated, the Smart Charger will use special repair charge pulses to de-sulphate the battery until battery becomes ready for normal bulk charge. If after 8 hours of repair charge, the battery still cannot be improved, it is then considered to be non- repairable and the LED will flash until battery is removed. Specifications Model AC Input Voltage AC Frequency Range No Load AC Current Full Load AC Current Max. Power Optimal Efficiency Bulk Charge Max. Current Level (Current Limit) for All Mode Vbulk@ for Sealed Lead Acid Mode Vbulk@ for Wet Mode Vbulk@ for Calcium-Calcium Mode Ripple & Noise (peak-peak) Protection SBC - 8268 100-240VAC 50 - 60Hz~ 100mA@100VAC / 80mA@230VAC 1.3A@100VAC / 1A@230VAC 65W ≥80% 2.2A 28.4V 28.8V 29.6V 200mV Overload, Short Circuit, Over Temperature, Reverse Polarity, No Spark for battery connected, Short Output ans 40HR Max. Charging Time Construction Cooling System Approvals Poly-Carbonate Casing, Water Resistant Natural Convection CE EN55014, 60335, 61000, 62233, IP55 for body only Dimension (WxHxD) Weight 150x60x30 mm Approx. 400g ◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE LEAD ACID BATTERY CHARGER Manson SBC - 8168 12V 5A Smart Battery Charger using Micro Processor control unit with pulse width modulation charge technology Manson LEAD ACID BATTERY CHARGER SBC - 2110 / 2115 / 2120 12V 3-Stage IUoU Battery Charger with Power Supply Mode Selection Specifications Accessories: A battery Charger with lead terminals Detachable leads with crocodile clips Connecting leads with ring teminals Features • • • • • • • • • Microprocessor Control (MCU) 4 Stage Charging (Repair, Bulk, Absorption, Float) in Pulse Width Modulation PWM method. MCU monitors the battery condition from initial qualifying checks, repair, or bulk to absorption to float charges. No worries of over or under charging battery, charger can be connected permanently to battery. Auto pulse repair charge for deeply depleted battery. Suitable for all types of Wet, Gel, AGM lead acid battery from 5 to 120 AH. Thermal control regulates charging current in hot or enclosed conditions Two swappable leads with clamps and eyelet terminal. Simple 3 selection key with intuitive iconic LED indicators. Universal AC input 100V to 240V Introduction This is a simple to use intelligent battery charger with the latest PWM charging technology controlled by a powerful Micro-Processor Control Unit. It is suitable for all types of lead acid batteries from 5AH to 120AH. Operation The Smart Charger runs its own self-tests when connected to an AC source of (100 to 240V). There are 3 Charge Modes to be selected: Motor Cycle / Car / Cold charge. The cold charge has higher voltage and can be used for either low temperature or calcium content battery. Checks faulty battery The Smart Charger will scan the battery by injecting short DC pulses. If the battery is found faulty, the LED flashes until the faulty battery is disconnected. Safety The charger only starts charging when it is connected to a battery. So there is no spark in contact with battery terminals. Reverse Polarity and Short Circuit protections are by electronics with flashing LED and charger will return to normal when the fault is cleared. A total time for Bulk and Absorption charge is limited to 40 hours to avoid over charging and waste of energy. Therefore it is not suitable for application of charging battery connected to external load connected. The charger is splash proof as its casing is sealed by ultra sonic. It is convection cooled and has thermal regulation to lower the charging current until the unit's temperature drops to an acceptable level. In the event of persistent rising temperature the charger will shut down its output at a preset maximum temperature. 3 Stage charging with Repair Charging When the battery is found to be chargeable, the battery will go through constant current Bulk Charge, then a Pulse Width Absorption Charge, and finally a Pulse Float Charge. The charger can be connected to battery permanently without over charge. Repair charging If the battery is found to be sulphated, the Smart Charger will use special repair charge pulses to de-sulphate the battery until battery becomes ready for normal bulk charge. If after 8 hours of repair charge, the battery still cannot be improved, it is then considered to be non- repairable and the LED will flash until battery is removed. Specifications Model AC Input Voltage AC Frequency Range No Load AC Current Full Load AC Current Max. Power Efficiency Bulk Charge Current Level (Current Limit) for Car / Low Temperature Mode Bulk Charge Current Level (Current Limit) for Motor Mode Vbulk@ for Car / Motor Mode Vbulk@ for Low Temperature Mode Vfloat High Level Vfloat Low Level Ripple & Noise (peak-peak) Protection SBC - 8168 100-240VAC 50 - 60Hz~ 100mA@100VAC / 80mA@230VAC 1.5A@100VAC / 1A@230VAC 70W ≥78% 5A 1.5A 14.4V 14.7V 13.5V 12.5V <200mV Protections Short Circuit Protection Overload Protection Reverse Polarity Protection Over Temperature Protection OVP (Output Over Voltage Protection) Thermostatically Controlled Variable Speed Fan (0 - full speed) Approvals Charge Cycle, Protection Indication Separate LED for Bulk, Absorption, Float and Fault Mode Power ON / OFF LED Indicator Power ON / OFF Switch Temperature Sensor Socket Anodized Aluminum Casing with Mounting Flange Dimension (WxHxD) Weight Included Accessories (cable, spare fuse) Optional Accessories (Remote Temperature Sensor) Recommended Battery Capacity Range Remarks Poly-Carbonate Casing, Water Resistant Natural Convection CE EN55014, 60335, 61000, 62233, IP55 for body only Dimension (WxHxD) Weight 150x60x30 mm Approx. 400g SBC - 2110 Yes 1.2A SBC - 2115 Yes 1.8A SBC - 2120 Yes 3A Yes Yes Yes Yes Yes Yes 10A Yes Yes Yes Yes Yes Yes 15A Yes Yes Yes Yes Yes Yes 20A <9V 5A <100mV ≥90% Yes No <9V 7.5A <100mV ≥87% Yes Yes <9V 10A <150mV ≥82% Yes Yes Yes Yes Yes Yes Yes Convection Cool Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes CE EN 60335 S.O.C. EN 55014 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 160x61x173 mm 160x61x173 mm 1.3 kg 1.4 kg Yes Yes Not Included Not Included 40AH to 100AH 60AH to 150AH 110VAC 60Hz~ (Input on request) 3 - STAGE CHARGING DIAGRAM BATTERY STATE OF CHARGE CHARGING VOLTAGE Overload, Short Circuit, Over Temperature, Reverse Polarity, No Spark for battery connected Construction Cooling System Approvals ◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE Model AC Input Voltage 180 - 260VAC, 50Hz~ AC Input Current at Full Load at 230VAC Output (Charge) Voltage Selections (2 battery type) Absorption Voltage for AGM/GEL Battery (14.0V to 14.2V) Absorption Voltage for WET Battery (14.3V to 14.5V) Absorption Voltage for Calcium-Calcium Battery (15.5V to 15.7V) Float Voltage 1 (13.2V) Float Voltage 2 (13.5V) Float Voltage 3 (13.8V) Maximum Output Charging Current (continuous) Soft Start Bulk Charge Battery Voltage to Trigger (cut-in) Soft Start Bulk Charge Mode Soft Start Bulk Charge Current Level (current limit) Ripple & Noise (peak-peak) Efficiency at Maximum Power Selectable Charger / Power Supply Mode (13.2 / 13.5 / 13.8V) Dual Bank (Outputs) Simultaneously Charging two Batteries (The two batteries must be of same chemistry, construction & type) CHARGING CURRENT TIME BULK CHARGE ABSORPTION CHARGE FLOATING CHARGE CONSTANT CURRENT CONSTANT VOLTAGE CONSTANT VOLTAGE ◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE Yes Yes Yes Yes Yes 160x61x207 mm 1.6 kg Yes Not Included 80AH to 200AH