Preview only show first 10 pages with watermark. For full document please download

561613842060a

   EMBED


Share

Transcript

Manson LEAD ACID BATTERY CHARGER CPC - 9120 / 9140 (LED) MCU Controlled 4 Stage Battery Charger Description This series of 20A/40A charger is built for adaptive charging of specific battery type. There are 5 lead acid battery types and one Lithium FePO4 battery to select. The MCU constantly monitors battery status, charging voltage & current and temperature of charger to ensure proper charging, and fail save protections for battery & charger. A Remote Control Indicator is supplied with the 40Amp model CPC-9140. The two LED of the Remote synchronizes with the two LEDs on the charger. The module can also change the charging stage to either Float or Bulk in turn. Charging Stages Features • Lead Acid Battery: Soft Start Bulk, Bulk, Absorption, Float + manual equalization Charge for Wet battery + 21 day Auto Recycle Charge. • Lithium Iron Phosphate (LiFePO4): Soft Start Bulk, Bulk, Absorption, (No Float) + Auto Recycle Charge. • Selectable Power Supply Mode at 13.8V • Wide Input AC range with over and under voltage makes this charger workable even with poor or unstable AC source. • Micro-Processor Control (MCU) charging profiles specifically for 6 battery types. • 4 Stage adaptive charging + Equalization + Auto Recycle • Power Supply Mode available at 13.8V output • Dual LED to indicate charging stage and output terminal voltage or battery voltage. • Supplied Remote Temperature Sensor for Battery to ensure precision charging and protection of battery from possible thermal runaway. • 40 Amp model is supplied with a Remote Control Indicator Specifications Model AC Input Voltage AC Input Current at Full Load (at 230VAC) Output (Charge) Voltage Selections WET AGM1 / AGM2 GEL CALCIUM LiFePO4 Power Supply mode Maximum Output Charging Current Soft Start Bulk Charge Battery Voltage to Trigger (cut-in) Soft Start Bulk Charge Mode Soft Start Bulk Charge Current Level (current limit) Protections Thermal output power derating Fan Cool Indication Approvals Remote Battery Temperature Sensor Dimension (WxHxD) Weight Optional Accessories (Not supplied) Recommended Battery Capacity Range CPC - 9120 200 - 240VAC, 50Hz~ <2.5A CPC - 9140 Absorption 14.4V 14.3V / 14.6V 14.1V 15.1V Stop Charging (no Float charge) 13.8V 20A Float 13.5V 13.2V / 13.6V 13.7V 13.8V 13.6V <3.5A 40A <12.3V 20A 10A Output short circuit, output overload, over temperature, output and input over voltage, input under voltage, Reverse Polarity Yes Yes 6 x LED (Charging status, Battery status, Battery Type & Fault) CE EN 60335 EN 55014 EN 61000 Yes 330 x 91 x 120mm 12.9x3.6x4.7inch. 2 kg 4.4lbs. Remote display of dual LED with 10M cable 80AH to 200AH 120AH to 400AH ◘ All values are based on the Standard ambient Temperature 25°C and Pressure 0.1Mpa. ◘ SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE