Preview only show first 10 pages with watermark. For full document please download

59010-512 A4 說明書 面 色-英文jts Uc-900-01版-1 - Av-iq

   EMBED


Share

Transcript

THE UC-900 ACTIVE ANTENNA COMBINER Caution : To reduce the risk of fire or shock hazard, do not expose this appliance to heat or moisture. Warning : To prevent electric shock, do not remove the cover. Refer all servicing to qualified service personnel or distributors. 8. Stop using and turn off the power when encounter abnormal situation. Contact 1. Read this instruction manual before using. 2. Keep this instruction manual. qualified service personnel or distributors. 3. Use the device in a well ventilated area. Do not block any ventilation openings. > Machine has smoke or burning smell > Water or any liquid has been spilled 4. Do not install the device near heat sources, Ex : Oven, furnaces or any other 9. Keep the machine outlet or plug clean. Dust gathering may result in bad apparatus that produce heat to prevent fire. connection or electric fire. 5. Do not place the device in humid or dusty environment to prevent short circuit. 10. Pay attention to the cable usage 6. Choose proper place to place the device to avoid product failure or personal > Hold the plug when unplugging. Breaking the wire may result in electric fire. injury caused by accidental drops. > Do not cut or twist the wire. Place the wire in a well ventilated area without 7. Do not use the device under lighting to avoid personal injury or equipment inflammable objects. damage caused by strikes. Instruction Manual The UC-900 UHF antenna combiner actively combine antenna outputs from wireless transmitter such as SIEM-111T or TG-10STX onto a single transmitting antenna,improving RF performance by reducing signal interference and saving further antenna system investments. A wide-band operation frequency range from 470MHz - 970MHz. Equipped with 4 DC power outlets that can be used for transmitters, without adding external power supplies. Accessories Specifications • Frequency Range : 470 - 970MHz • Input Connectors : Up to 4 transmitters • Full System Gain : 0dB(±2dB) • Maximum RF Input Power : +20dBm (100mW) /CH • LED Indicator (Input signal Threshold) : >+5dBm (Threshold Power) • Power Consumption : 6W • Input / Output Connectors : BNC@50Ω : 4 Antenna Input at back, 1 Antenna Output at front. DC Output Jacks : 4 at back. • DC Output : DC12V/1A Max (4 outputs, total of 48W) • Input Voltage : 100-240 VAC, 50/602Hz, MAX 2A • Dimensions (m/m) : W480 * H45 * D260 mm • Weight : 2.3kg • AC Power Cable x 1 • DC Power Cable x 4 • BNC to BNC Cable x 4 Operating Controls UC-900 Front Panel Antenna Combiner Antenna Output 3 CH1 CH2 CH3 CH4 2 1 POWER SWITCH : The indicator will light up when power is on. 2 SIGNAL INDICATOR : When the input power signal is greater than +5dBm, the corresponding channel will light up. 3 BNC socket antenna output : Signal will be transmitted once combined. 59010-512-01 UC-900 Rear Panel DC Output 12Vx4A(MAX) RF Input 100-240V 50/60Hz FUSE: T3.15A/250V 5 6 4 4 BNC socket antenna input : Can be connected to 4 transmitters. For best performance, please do not input more than +20dBm. 5 DC output jacks : Provides DC 12V at max. 1A from each jack. (Total of 48W) 6 AC power input : Power input 100~140VAC / 2A Max, 50/60Hz. UC-900 Antenna Configuration OR 1/2 wave antenna UDA-49P UC-900 Front Panel Antenna Combiner Antenna Output CH1 CH2 CH3 CH4 UC-900 Rear Panel DC Output 12Vx4A(MAX) RF Input 100-240V 50/60Hz FUSE: T3.15A/250V Wireless Transmitter Installation and Operation • Use 1/2 wave antenna or UDA-49P directional antenna to connect to the UC-900 Antenna Output. To avoid losing of transmitting output power, if possible, please use shortest BNC –BNC cable when connect UDA-49P directional antenna to the UC-900 Antenna Output. • Use the supplied BNC-BNC cables to connect the antenna outputs of each transmitter to the antenna inputs of the antenna combiner. • If needed, connect the DC OUTPUT of combiner to the DC INPUT of each transmitter. • Turn on the power and setup the frequencies of all transmitters. (All transmitters must be in the same frequency range.) • Please turn off the power when not use or before disconnecting the cables or antenna. Note • UC-900 provides 4 RF input with operation frequency range of 470~970MHz. For optimum performance, please use same frequency range for all transmitters. ( UDA-49P directional antenna not restricted. ) • Please use standard 50Ω BNC cable when connecting to the UC-900. • Turn off the power of transmitters and UC-900 before installing or disconnecting.