Transcript
5970 POTS Lifeline Splitters 5970-B1-010, 5970-B1-014, 5970-B1-504, 5970-B1-1008
5970 POTS Splitters with Lifeline support
✓ ✓
Available in 4U and 8U shelves 19" or 23" rack mountable
The 5970 Series POTS Splitter is a high density, modular solution for ADSL2+ and VDSL2 applications. The shelves are available in 4U and 8U configurations offering 504 and 1008 ports respectively in 72-port increments to match with the highest density ADSL2+ 72-port MxK cards. The 5970 Series shelves sit between the subscriber lines and the
✓
Low cost per port
CO-serving equipment. Also designed for remote cabinets, the 5970 allows customers to boost capacity without consuming excessive rack
✓
"Make before break" Lifeline POTS support
space. The front/back connections create a clean cable management solution. All DSL connections are at the front of the shelf and all POTS and LINE interfaces at the rear. Separating DSL and voice connections
✓
✓ ✓
Compliant with ANSI (900 Ohm) and ETSI (600 Ohm) standards Compliant with VDSL2 up to 30a spectrum Electrically and Temperature Hardened to handle remote locations
significantly reduces video-impairing crosstalk. The 5970 Series splitters are environmentally hardened for demanding locations. The backplane contains make-before-break connectors from the outside plant tip and ring to the POTS tip and ring, respectively, to maintain “LIFE LINE” service when a line card is removed from the chassis.
DAT ASHEET
5970 POTS Lifeline Splitters
Technical Specifications Dimensions ■
■
■
5970-B1-504: 17-1/16”(W) x 10”(D) x 14”(H) [434mm x 254mm x 356mm] 5970-B1-1008: 17-1/16”(W) x 10”(D) x 7”(H) [434mm x 254mm x 178mm] Mounting: 19“(483mm) or 23“(584mm) TIA/EIA racks
Weight ■ ■ ■ ■
5970-B1-504: 10.6lb (4.8kg) 5970-B1-1008: 21.2lb (9.6kg) 5970-B1-010: 3.1lb (1.38kg) 5970-B1-014: 2.65lb (1.20kg)
Interfaces ■
■
■
LINE (local loop) - Two 78-pin AMPLIMITE HD-22 Connector (Rear access) PSTN - Two 78-pin AMPLIMITE HD-22 Connector (Rear access) DSL - Two 78-pin AMPLIMITE HD-22 Connector (Front access)
Standards Support ■ ■
ANSI T1.413, T1.424 ITU-T G.992.1, G.992.3, G.992.5, G.993.1, G.993.2
Regulatory Compliance ■ ■ ■ ■
UL/CSA NEBS CE RoHS 5
Operating Requirements ■
■
■
Operating Temperature: -40 to +65 degrees Celsius Storage Temperature: -40 to +70 degrees Celsius Humidity: 5 to 95% (non-condensing)
Ordering Information 5970-B1-504
7 SLOT 4RU POTS SPLITTER CHASSIS
5970-B1-1008
14 SLOT 8RU POTS SPLITTER CHASSIS
5970-B1-010
72 PORT 900 OHM VDSL2 COMPLIANT POTS SPLITTER CARD
5970-B1-014
72 PORT 600 OHM VDSL2 COMPLIANT POTS SPLITTER CARD
2 0 1 2 05 December 2012 17:19:04