Preview only show first 10 pages with watermark. For full document please download

φυλλάδιο τεχνικών χαρακτηριστικών

   EMBED


Share

Transcript

UL 7-12 12V 7AH General UL7-12 Terminal Type Container Material Rated Capacity Part Number: UL7-12 Length: 151 ± 2 mm (5.94 inches) Width: 65 ± 2 mm (2.56 inches) Container Height: 93.5 ± 2 mm (3.68 inches) Total Height (with terminal): 99 ± 2 mm (3.90 inches) Approx Weight: Approx 2.05kg (4.52lbs) Normal Voltage 12V Normal Capacity (20HR) 7AH Standard Terminal F1 Optional Terminal F2 Standard Option ABS Flame Retardant Option (FR) UL94:VO 7.00 AH/0.350A (20hr, 1.80V/cell, 25°C / 77°F) 6.51 AH/0.653A (10hr, 1.80V/cell, 25°C / 77°F) 6.00 AH/1.20A (5hr, 1.75V/cell, 25°C / 77°F) 5.37 AH/1.79A (3hr, 1.75V/cell, 25°C / 77°F) 4.55 AH/4.55A (1hr, 1.60V/cell, 25°C / 77°F) Max Discharge Current 105A (5s) Internal Resistance Approx 23mΩ Discharge Characteristics Operating Temp. Range Discharge: -15 ~ 50°C (5 ~ 122°F) Charge: 0 ~ 40°C (5 ~ 104°F) Storage: -15 ~ 40°C (5 ~ 104°F) Nominal Operating Temp. Range 25 ± 3°C (77 ± 5°F) Cycle Use Initial Charging Current less than 2.1A.Voltage Standby Use No limit on Initial Charging Current Voltage Capacity affected by Temperature 40°C (104°F) 103% 25°C (77°F) 100% 0°C (32°F) 86% Design Floating Life at 20°C 5 Years Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(°77F) and then a refresh charge is required. For higher temperatures the time interval will be shorter. Dimensions 99 2 93 2 4.75(0.187) 3.2(0.126) 6.35(0.25) 0.8(0.031) 65 2 43 2 F1 Terminal 151 2 ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE 1 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk ISO9001 Constant Current Discharge (Amperes) at 25°C (77°F) F.V/Time 5 min 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 18.0 12.8 10.48 8.79 6.53 4.79 3.86 2.29 1.69 1.36 1.14 0.98 0.774 0.640 0.345 1.80V/cell 21.4 14.3 11.4 9.44 6.94 5.05 4.03 2.38 1.74 1.40 1.17 1.01 0.791 0.653 0.350 1.75V/cell 24.2 15.6 12.2 10.0 7.29 5.27 4.18 2.45 1.79 1.43 1.20 1.03 0.805 0.663 0.357 1.70V/cell 26.7 16.7 12.9 10.5 7.59 5.46 4.32 2.51 1.83 1.46 1.22 1.05 0.817 0.672 0.361 1.65V/cell 28.8 17.7 13.5 10.9 7.86 5.62 4.46 2.57 1.86 1.48 1.23 1.06 0.826 0.680 0.365 1.60V/cell 30.6 18.6 14.1 11.3 8.09 5.76 4.55 2.61 1.89 1.50 1.25 1.07 0.834 0.685 0.367 Constant Power Discharge (Watts) at 25°C (77°F) F.V/Time 5 min 10 min 15 min 20 min 30 min 45 min 1h 2h 3h 4h 5h 6h 8h 10h 20h 1.85V/cell 34.2 24.5 20.2 17.1 12.8 9.44 7.64 4.56 3.37 2.72 2.29 1.99 1.565 1.296 0.701 1.80V/cell 40.2 27.2 21.9 18.3 13.5 9.91 7.96 4.72 3.47 2.79 2.34 2.03 1.593 1.318 0.708 1.75V/cell 45.1 29.5 23.3 19.3 14.2 10.3 8.23 4.85 3.55 2.85 2.39 2.06 1.616 1.334 0.719 1.70V/cell 49.2 31.3 24.5 20.1 14.7 10.6 8.48 4.96 3.62 2.89 2.42 2.09 1.633 1.347 0.725 1.65V/cell 52.6 32.9 25.5 20.8 15.2 10.9 8.73 5.05 3.68 2.93 2.45 2.11 1.649 1.359 0.731 1.60V/cell 55.5 34.3 26.3 21.5 15.5 11.2 8.88 5.12 3.72 2.96 2.47 2.13 1.660 1.367 0.734 Terminal Voltage (V) Discharge Characteristics 12V Battery (V) 6V 4V 2V Battery Battery Battery (V) (V) (V) 13.0 6.5 4.33 2.16 12.0 6.0 4.00 2.00 11.0 5.5 3.66 1.84 10.0 5.0 3.33 1.68 9.0 4.5 3.00 1.52 8.0 4.0 2.67 1.36 Float Charging Characteristics Charge Charging Charging Volume Current Voltage % (XCA) (V) (V) Temperature:25°C(77°F) 0.4C 1C 3C 1 2 4 0.207C 0.093C 0.05C 0.628C 2C 6 8 10 20 40 60 2 4 Min 6 8 10 0.25 120 110 100 90 80 70 60 50 40 30 20 10 0 20 0.20 0.15 15.0 7.5 1.40 7.0 13.0 6.5 0.10 12.0 6.0 0.05 11.0 5.5 0.10CA-2.25V/cell temperature 25°C 2.33 Charge Voltage (Constant 2.25v/cell) 1.83 Charging Current 0 0 4 8 16 12 Life Expectancy (year) Capacity (%) 0. 2 C A 1.0 CA 3.0 CA 2.0 CA 20 -10 0 10 20 30 40 20 68 50 30 86 Remaining Capacity (%) Capacity(%) 30% DOD Ambient Temperature: 25°C (77°F) 200 400 600 800 1000 250C 60 B 300C 40 C 0 40 A C 20 0 2 4 6 8 10 Storage Time (Months) 12 A No supplementary required (Carryout supplementary charge before use if 100% capacity is required.) B Supplementary charge required before use. Optional charging way as below: 1. Charged for above 3 days at limited current 0.25CA and constant voltage 2.25V/cell. 2. Charged for above 20 hours at limited current 0.25CA and constant voltage 2.25Vcell. 3. Charged for 8 ~ 10 hours at limited current 0.05 CA. C Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this is reached. 1200 Number of Cycles 100C 80 0 0 50 °C 122 °F 100 80 0 40 104 Self Discharge Characteristics 100 20 40 1 120 40 36 2 Testing condition Discharging:current 0.17C (FV 1.7V/cell); Charging:current 0.25C max, voltage 2.45V/cell; Charging volume:125% of discharged capacity. 50% DOD 32 Battery Temperature Cycle Life in Relation to Depth of Discharge 100% DOD 28 Charging voltage: 2.25V/cell Temperature (°C) 60 24 10 8 6 5 4 3 0.5 0 -20 20 Effect of Temperature on Long Term Float Life A 0.05 C 0.1 CA 40 2.00 Charging Time (Hours) 120 60 2.17 After 50% Discharge After 100% Discharge h Temperature Effects in Relation to Battery Capacity 80 2.50 Charged Volume Discharge Time 100 Charging Voltage (V) ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE 2 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk ISO9001