Preview only show first 10 pages with watermark. For full document please download

обзор оборудования

   EMBED


Share

Transcript

򔻐򗗠򙳰 ® IBM System x3250 M4 IBM System x at-a-glance guide The System x3250 M4 single-socket 1U rack server is designed for small businesses and first-time server buyers looking for a solution to improve business efficiency. It delivers several IBM® innovative features in a compact 1U form factor with a competitive price. The IBM System x3250 M4 provides next-generation performance in an innovative and compact design with flexible configuration options, built-in security, and systems management capabilities. This server is designed for infrastructure applications such as firewall, security, disaster recovery, name server, authentication, credit card processing, email, domain controller, and more. It leverages the next-generation dual-core and quad-core Intel Xeon processor technology. Figure 1. IBM System x3250 M4 Did you know The System x3250 M4 server is a compact, cost-effective, single-processor 1U rack server that has been optimized to provide outstanding availability, manageability, and performance features to small-to-medium-sized businesses, retail stores, or distributed enterprises. It supports the latest Xeon processors for applications that require performance and stability, and Core i3 processors for applications that require lower cost. The system includes features not typically seen in this class of system, such as standard, embedded RAID-0/1 for simple-swap models, remote control capabilities even when the machine is powered off, and Predictive Failure Analysis (PFA) on processor and memory. This flexible 1U rack-mountable server is also highly upgradable and expandable, scaling from low-cost, fixed-function models to feature-rich, highly available models. IBM System x3250 M4 1 Locations of key components and connectors Figure 2 shows the front of the server. Figure 2. IBM System x3250 M4 rack server (front view) Figure 3 shows the rear of the server. Figure 3. IBM System x3250 M4 rack server (rear view) IBM System x3250 M4 2 Figure 4 shows the locations of key components inside the server. Figure 4. IBM System x3250 M4 rack server (inside view) IBM System x3250 M4 3 Standard specifications Table 1. Standard specifications (part 1) Components Specification Form factor 1U Rack. Processor One quad-core Intel Xeon E3-1200 series processor (up to 3.5 GHz/8 MB) or one dual-core Intel Core i3 2100 series processor (up to 3.3 GHz/3 MB) with up to 1333 MHz memory speed. Supports specific quad-core and dual-core processors via Configure-To-Order (CTO). Memory cache Up to 8 MB L3 for Intel Xeon E3-1200 series processors. Up to 3 MB L3 for Intel Core i3 2100 series processors. Chipset Intel C202. Memory DIMM slots 4. Memory capacity Up to 32 GB with 8 GB DDR3 UDIMMs and four populated DIMM slots. RDIMMs are not supported. Memory protection ECC. Disk drive bays Three configurations:  Up to two 3.5" simple-swap SATA HDDs (some models)  Up to four 2.5" hot-swap SAS HDDs (some models)  Up to four 2.5" simple-swap SAS HDDs (CTO only) Maximum internal storage Up to 2.4 TB with 600 GB SAS HDDs, or up to 4.0 TB with 2 TB SATA HDDs. Intermix of SAS/SATA is not supported. RAID Support Software RAID 0, 1 with ServeRAID C100 controller. Optional hardware RAID 0, 1, 1E with ServeRAID-BR10il v2 or M1015. Optional upgrade to RAID 5 is available for M1015 and C100. Optional RAID 5, 50 with ServeRAID M5014. Optical drive bays One, support for DVD-ROM or multiburner. Tape drive bays No internal tape drive support. Network interfaces Integrated 2 port Gigabit Ethernet/1 port is shared with IMM. PCI Expansion slots Two PCI Express 2.0 slots:  One PCI Express 2.0 x4 (for use only by the optional BR10il v2 controller)  One PCI Express 2.0 x8 External ports Two USB 2.0 ports on front. Four USB 2.0, one DB-15 video, one DB-9 serial, two RJ-45 Gigabit Ethernet network ports (one is dedicated, one is shared with IMM) on rear. Cooling IBM Calibrated Vectored Cooling™ with 4 fans and N+1 redundancy. Power supply One fixed 300 W AC power supply or redundant 460 W AC power supply (model dependent) Hot-swap components Hot-swap SAS drives (some models) Systems management UEFI, IBM Integrated Management Module (IMM), Predictive Failure Analysis, Automatic Server Restart, IBM Systems Director and IBM Systems Director Active Energy Manager™, IBM ServerGuide. IBM System x3250 M4 4 Table 1. Standard specifications (part 2) Components Specification Security features Power-on password, administrator's password, Trusted Platform Module (TPM). Video Matrox G200eV with 16 MB memory integrated into the IMM. Maximum resolution is 1600x1200 at 85 Hz with 64 K colors. Operating systems supported Microsoft Windows Server 2008 R2 and 2008, Red Hat Enterprise Linux 5, SUSE Linux Enterprise Server 11. Limited warranty Three-year (2583) customer-replaceable unit and onsite limited warranty with 9x5/next-business-day (NBD) response time. Service and Support Optional service upgrades are available through IBM ServicePacs®: 24x7/NBD or four hours onsite repair, 1-year or 2-year warranty extension, remote technical support for IBM hardware and selected IBM and third-party (Microsoft, Linux, VMware) software. The x3250 M4 server ships with the following items:        Statement of Limited Warranty Important Notices Rack installation instructions Documentation CD that contains the Installation and User's Guide IBM Systems Director 6.2 Base for x86 DVD-ROM Rack Mount Kit One 2.8 m C13 - C14 power cord IBM System x3250 M4 5 Standard models Table 2 lists the standard models. Table 2. Standard models Model† Intel Processor (one maximum)* Memory Disk adapter HDD bays Disks GbE DVD PS 2583-32x 1x Pentium G850 2.9GHz 2C 3MB 1333MHz 1x 2GB C100 2x3.5" SS Open 2 Open 300W 2583-42x 1x Corei3-2100 3.1GHz 2C 3MB 1333MHz 1x 2GB C100 2 3.5" SS Open 2 Open 300W 2583-62x 1x Xeon E3-1220 3.1GHz 4C 8MB 1333MHz 1x 2GB C100 2x3.5" SS Open 2 Open 300W 2583-72x 1x Xeon E3-1270 3.4GHz 4C 8MB 1333MHz 1x 4GB BR10ilv2 4x2.5" HS Open 2 Open 460W * Processor detail: Processor quantity, processor model, core speed, number of cores, L3 cache, front-side bus speed Express models Table 3 lists the Express models that are available in certain regions. Express models are preconfigured with additional components such as processors, memory, and disks with the purpose of making the ordering and installation process simpler. Table 3. Express models Model Intel Processor (one maximum)* Memory Disk adapter HDD bays Disks GbE DVD 2583-EAU 1x Xeon E3-1230 3.2GHz 4C 8MB 1333MHz 1x 2GB C100 2x 3.5" SS 2x250† 2 Multi 2583-EBU 1x Xeon E3-1270 3.4GHz 4C 8MB 1333MHz 1x 4GB C100 2x 3.5" SS Open 2 Multi 2583-E1G 1x Corei3-2100 3.1GHz 2C 3MB 1333MHz 1x 2GB C100 2x 3.5" SS Open 2 Multi 2583-E2G 1x Xeon E3-1220 3.1GHz 4C 8MB 1333MHz 1x 2GB C100 2x 3.5" SS Open 2 Multi 2583-E3G 1x Xeon E3-1230 3.2GHz 4C 8MB 1333MHz 1x 4GB C100 2x 3.5" SS 1x250† 2 Multi 1x Xeon E3-1220 3.1GHz 4C 8MB 1333MHz 1x 2GB C100 2x 3.5" SS Open 2 Multi 2583-E2G 1x Xeon E3-1220 3.1GHz 4C 8MB 1333MHz 1x 2GB C100 2x 3.5" SS Open 2 Multi 2583-E4G 1x Xeon E3-1240 3.3GHz 4C 8MB 1333MHz 1x 4GB C100 2x 3.5" SS Open 2 Multi NA & LA NE & SW IOT CEE & MEA 2583-E2G RCIS * Processor detail: Processor quantity, processor model, core speed, number of cores, L3 cache, front-side bus (FSB) speed. † These models have either one or two 250 GB SATA drives, as indicated. IBM System x3250 M4 6 Processor options The server supports only one processor, which is already installed in all standard and Express models. No additional processor options are available. Table 4 lists all processors available in standard models of x3250 M4 or via CTO. If there is no corresponding where-used model for a particular processor, then that processor is only available through the configure-to-order (CTO) process. Table 4. Processor options Part number Description Standard models where used None* Intel Pentium G840 2.8 GHz 2C 3 MB 1333 MHz DDR3 65W - None* Intel Pentium G850 2.9 GHz 2C 3 MB 1333 MHz DDR3 65W 32x None* Intel Pentium G860 3.0 GHz 2C 3 MB 1333 MHz DDR3 65W - None* Intel Pentium G620 2.6 GHz 2C 3 MB 1066 MHz DDR3 65W - None* Intel Pentium G630 2.7 GHz 2C 3 MB 1066 MHz DDR3 65W - None* Intel Corei3-2100, 3.1 GHz 2C 3 M cache 1333 MHz DDR3 65 W 42x None* Intel Corei3-2120, 3.3 GHz 2C 3 M cache 1333 MHz DDR3 65 W - None* Intel Xeon E3-1220 3.1 GHz 4C 8 MB cache 1333 MHz DDR3 80 W 62x None* Intel Xeon E3-1220L 2.2 GHz 2C 3 MB cache 1333 MHz DDR3 20 W - None* Intel Xeon E3-1230 3.2 GHz 4C 8 MB cache 1333 MHz DDR3 80 W - None* Intel Xeon E3-1240 3.3 GHz 4C 8 MB cache 1333 MHz DDR3 80 W - None* Intel Xeon E3-1260L 2.3 GHz 4C 8 MB cache 1333 MHz DDR3 45 W - None* Intel Xeon E3-1270 3.4 GHz 4C 8 MB cache 1333 MHz DDR3 80 W 72x None* Intel Xeon E3-1280 3.5 GHz 4C 8 MB cache 1333 MHz DDR3 95 W - * No additional processor options are available. The server supports only one processor, which is already included in a standard or custom configuration. Memory options The x3250 M4 has four DIMM slots, and only DDR3 ECC UDIMMs are supported. The CPU has two memory channels and there are two DIMMs per channel. If more than one DIMM is planned to be installed, then DIMMs must be installed in a pair, and both DIMMs in a pair must be identical in type and size. Table 5 lists the memory options supported by the server. Table 5. Memory options Part number Description Maximum supported Standard models where used 44T1568 1 GB (1x 1 GB, 1Rx8) PC3-10600 CL9 ECC 1333 LP UDIMM 4 - 44T1570 2 GB (1x 2 GB, 1Rx8) PC3-10600 CL9 ECC 1333 LP UDIMM 4 32x, 42x, 62x 44T1571 4 GB (1x 4 GB, 2Rx8) PC3-10600 CL9 ECC 1333 LP UDIMM 4 72x 90Y3165 8GB (4Gb, 2Rx8) PC3-10600 DDR3-1333 LP UDIMM 4 - IBM System x3250 M4 7 Internal disk storage options The IBM System x3250 M4 supports the following internal disk storage configurations:   Two 3.5" Simple-Swap SATA hard drive bays Four 2.5" SFF simple-swap SAS hard drive bays (CTO only) Table 6 lists the hard drive options available for internal disk storage in the x3250 M4 server. The intermixing of SAS and SATA drives is not supported. Table 6. Disk drive options Part number Description Maximum supported 3.5" Simple-Swap SATA HDDs 39M4508 250 GB 7200 RPM 3.5" Simple-Swap SATA II 2 39M4514 500 GB 7200 RPM 3.5" Simple-Swap SATA II 2 43W7750 IBM 250 GB 7.2K SATA 3.5" Simple-Swap HDD 2 None* IBM Server 1 TB 7200 SATA 3.5" Simple Swap HDD 2 42D0787 IBM 2 TB 7200 NL SATA 3.5" SS HDD 2 2.5" Simple-Swap SAS HDDs 49Y1991 IBM 300 GB 10K 6 Gbps SAS 2.5" SFF SS HDD 4 49Y1996 IBM 146 GB 15K 6 Gbps SAS 2.5" SFF SS HDD 4 49Y2027 IBM 600 GB 10K 6 Gbps SAS 2.5" SFF SS HDD 4 81Y9734 IBM 250GB 7.2K 6Gbps NL SATA 2.5" SFF SS HDD 4 81Y9738 IBM 500GB 7.2K 6Gbps NL SATA 2.5" SFF SS HDD 4 81Y9742 IBM 1TB 7.2K 6Gbps NL SATA 2.5" SFF SS HDD 4 2.5" Hot-Swap SAS HDDs 42D0707 IBM 500GB 7200 6Gbps NL SAS 2.5" SFF Slim-HS HDD 4 42D0677 IBM 146GB 15K 6Gbps SAS 2.5" SFF Slim-HS HDD 4 42D0637 IBM 300GB 10K 6Gbps SAS 2.5" SFF Slim-HS HDD 4 49Y2003 IBM 600GB 10K 6Gbps SAS 2.5" SFF Slim-HS HDD 4 * This drive cannot be ordered separately. It is only available via special bid or the CTO process. IBM System x3250 M4 8 Table 7 lists the RAID controllers and additional options used for internal disk storage of x3250 M4 server. Either a ServeRAID BR10il v2, ServeRAID M1015, or ServeRAID M5014 is required for models with 2.5" simple-swap SAS drive bays or 2.5" hot-swap SAS drive bays. Table 7. RAID controllers for internal storage Part number Description Maximum quantity supported Standard models where used 49Y4731 ServeRAID-BR10il SAS/SATA Controller v2 1 72x 46M0831 ServeRAID M1015 SAS/SATA Controller 1 - 46M0832 ServeRAID M1000 Series Advance Feature Key 1 - 46M0916 ServeRAID M5014 SAS/SATA Controller 1 - If the BR10il v2 controller is used, it is installed in slot 1 (PCIe x4). Other RAID controllers are installed in slot 2 (PCIe x8), and slot 1 is left vacant. Only one RAID controller can be used with the server to support internal HDDs. Features of the supported RAID controllers are discussed below. The ServeRAID BR10il v2 SAS/SATA Controller has the following specifications:       One Mini-SAS internal connector Supports RAID levels 0, 1, and 1E 3 Gbps throughput per port Based on the LSI 1064E controller PCI Express 2.0 x4 host interface Stripe size: 64 KB (fixed) For more information, see the ServeRAID-BR10il SAS/SATA Controller v2 for IBM System x at-a-glance guide: http://www.redbooks.ibm.com/abstracts/tips0741.html?Open The ServeRAID M1015 SAS/SATA Controller has the following specifications:        Two Mini-SAS internal connectors Supports RAID levels 0, 1, and 10 Supports RAID levels 5 and 50 with optional ServeRAID M1000 Series Advanced Feature Key 6 Gbps throughput per port Based on the LSI SAS2008 6 Gbps RAID on Chip (ROC) controller PCI Express 2.0 x8 host interface Configurable stripe size up to 64 KB For more information, see the ServeRAID M1015 SAS/SATA Controller for System x at-a-glance guide: http://www.redbooks.ibm.com/abstracts/tips0740.html?Open The ServeRAID M5014 SAS/SATA Controller has the following specifications:       Two Mini-SAS internal connectors Supports RAID levels 0, 1, 5, 10, and 50 6 Gbps throughput per port PCI Express 2.0 x8 host interface Based on the LSI SAS2108 6 Gbps RAID on Chip (ROC) controller 256 MB of onboard cache For more information, see the ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x at-a-glance guide: http://www.redbooks.ibm.com/abstracts/tips0738.html?Open IBM System x3250 M4 9 Internal tape drives The server does not support internal tape drive options. Optical drives The server supports the optical drive options listed in Table 8. Table 8. Optical drives Part number Description Maximum quantity supported Standard models where used 46M0901 IBM UltraSlim Enhanced SATA DVD-ROM 1 - 46M0902 UltraSlim Enhanced SATA Multi-Burner 1 - IBM UltraSlim Enhanced SATA DVD-ROM (part number 46M0901) supports the following media and speeds for reading:              CD-ROM 24X CD-DA (DAE) 20X CD-R 24X CD-RW 24X DVD-ROM (single layer) 8X DVD-ROM (dual layer) 8X DVD-R (4.7 GB) 6X DVD-R DL 4X DVD+R 6X DVD+R DL 4X DVD-RW (4.7 GB) 4X DVD+RW 4X DVD-RAM (4.7/9.4 GB) 4X IBM UltraSlim Enhanced SATA Multi-Burner (part number 46M0902) supports the same media and speeds for reading as DVD-ROM (46M0901). In addition, this drive supports the following media and speeds for writing:             CD-R 24X CD-RW 4X High Speed CD-RW 10X Ultra Speed CD-RW 16X Ultra Speed Plus CD-RW 16X DVD-R 8X DVD-R DL 6X DVD+R 8X DVD+R DL 6X DVD-RW 6X DVD+RW 8X DVD-RAM 5X IBM System x3250 M4 10 External disk storage expansion Currently, the server does not support external disk storage expansion (JBOD). External tape backup The server supports the external tape attachment options listed in Table 9. Table 9. External tape options Part number Description External tape expansion enclosures for internal tape drives 87651UX 1U Tape Drive Enclosure 8767HHX Half High Tape Drive Enclosure 87651NX 1U Tape Drive Enclosure (with Nema 5-15P LineCord) 8767HNX Half High Tape Drive Enclosure (with Nema 5-15P LineCord) Tape enclosure adapters (with cables) 40K2599 SAS Enclosure Adapter Kit 44E8869 USB Enclosure Adapter Kit Internal tape drives supported by external tape enclosures 46C5364 IBM RDX Removable Hard Disk Storage System - Internal USB 160 GB Bundle 46C5387 IBM RDX Removable Hard Disk Storage System - Internal USB 320 GB Bundle 46C5388 IBM RDX Removable Hard Disk Storage System - Internal USB 500 GB Bundle 39M5636 IBM DDS Generation 6 USB Tape Drive 46C5399 IBM DDS Generation 5 USB Tape Drive External tape drives 362516X IBM RDX Removable Hard Disk Storage System - External USB 160 GB Bundle 362532X IBM RDX Removable Hard Disk Storage System - External USB 320 GB Bundle 362550X IBM RDX Removable Hard Disk Storage System - External USB 500 GB Bundle 3628L5X IBM External Half High LTO Gen 5 SAS Tape Drive (with US linecord) 3628N5X IBM External Half High LTO Gen 5 SAS Tape Drive (no US linecord) Internal tape drives are installed in a Half High Tape Drive Enclosure (up to one tape drive per enclosure) or in a 1U Tape Drive Enclosure (up to two tape drives). One USB Enclosure Adapter Kit is required per tape drive. (x3250 M4 only supports USB connections for internal USB tape drives in external tape enclosures.) IBM System x3250 M4 11 I/O expansion options Standard models offers two PCI Express 2.0 slots (one x4 and one x8). The slot form-factors are:   Slot 1: PCI-E x4 Gen 2 (for use only by the optional BR10il v2 controller) Slot 2: PCI-E x8 Gen 2, full-height, half-length Network adapters The x3250 M4 offers two integrated Gigabit Ethernet ports. One port is shared with Integrated Management Module (IMM). The Integrated NICs have the following features:        Intel 82574L chip TCP/UDP, IPv4, and IPv6 checksum offloads TCP Segmentation/Transmit Segmentation Offloading (TSO) Wake on LAN support 802.1Q VLAN tagging support Support for jumbo frames up to 9 KBytes NIC Teaming (Load Balancing and Failover) with Intel PROSet software Table 10 lists additional supported network adapters. Table 10. Network adapters Part number Description Maximum quantity supported Emulex 10GbE Virtual Fabric Adapter for IBM System x 1 42C1780 NetXtreme II 1000 Express Dual Port Ethernet Adapter 1 49Y4220 NetXtreme II 1000 Express Quad Port Ethernet Adapter 1 49Y4230 Intel Ethernet Dual Port Server Adapter I340-T2 for IBM System x 1 49Y4240 Intel Ethernet Quad Port Server Adapter I340-T4 for IBM System x 1 10 Gb Ethernet 49Y4250 Gigabit Ethernet IBM System x3250 M4 12 Storage host bus adapters Table 11 lists the storage host bus adapters (HBAs) supported by x3250 M4 server. Table 11. Storage adapters Part number Description Maximum quantity supported 46M6049 Brocade 8 Gb FC Single-port HBA for IBM System x 1 46M6050 Brocade 8 Gb FC Dual-port HBA for IBM System x 1 42D0485 Emulex 8 Gb FC Single-port HBA for IBM System x 1 42D0494 Emulex 8 Gb FC Dual-port HBA for IBM System x 1 42D0501 QLogic 8 Gb FC Single-port HBA for IBM System x 1 42D0510 QLogic 8 Gb FC Dual-port HBA for IBM System x 1 Fibre Channel Converged Network Adapters (CNA)* 42C1820 Brocade 10 Gb Dual-port CNA for IBM System x 1 42C1800 QLogic 10 Gb Dual Port CNA for IBM System x 1 IBM 6 Gb SAS HBA Controller 1 SAS 46M0907 * Note: Converged Network Adapters require SFP+ optical transceivers or DAC cables that must be purchased separately. PCIe SSD adapters The server does not support the High IOPS SSD adapters. Power supplies The server supports one fixed 300 W AC power supply. Standard models ship with one 2.8-m C13 - C14 power cord. IBM System x3250 M4 13 Remote management The server contains IBM IMM, which provides advanced service-processor control, monitoring, and alerting functions. If an environmental condition exceeds a threshold or if a system component fails, the IMM lights LEDs to help you diagnose the problem, records the error in the event log, and alerts you to the problem. Optionally, the IMM also provides a virtual presence capability for remote server management capabilities. The IMM provides remote server management through industry-standard interfaces:     Intelligent Platform Management Interface (IPMI) Version 2.0 Simple Network Management Protocol (SNMP) Version 3 Common Information Model (CIM) Web browser Integrated virtualization The x3250 M4 currently does not support VMware ESXi embedded virtualization. IBM System x3250 M4 14 Uninterruptible power supply units The server supports the attachments to the uninterruptible power supply (UPS) units listed in Table 12. Table 12. Uninterruptible power supply units Part number Description Rack-mounted UPS 53951AX IBM 1500VA LCD 2U Rack UPS (100 V/120 V) 53951KX IBM 1500VA LCD 2U Rack UPS (230 V) 53952AX IBM 2200VA LCD 2U Rack UPS (100 V/120 V) 53952KX IBM 2200VA LCD 2U Rack UPS (230 V) 53953AX IBM 3000VA LCD 3U Rack UPS (100 V/120 V) 53953JX IBM 3000VA LCD 3U Rack UPS (200 V/208 V) 53953KX IBM 3000VA LCD 3U Rack UPS (230 V) 53956AX IBM 6000VA LCD 4U Rack UPS (200 V/208 V) 53956KX IBM 6000VA LCD 4U Rack UPS (230 V) 53959KX IBM 11000VA LCD 5U Rack UPS (200 V/208 V/230 V) Power distribution units The server supports attachments to the power distribution units (PDUs) listed in Table 13. Table 13. Power distribution units (part 1) Part number Description Switched and monitored PDUs 46M4002 IBM 1U 9 C19/3 C13 Active Energy Manager DPI® PDU 46M4003 IBM 1U 9 C19/3 C13 Active Energy Manager 60A 3-Phase PDU 46M4004 IBM 1U 12 C13 Active Energy Manager DPI PDU 46M4005 IBM 1U 12 C13 Active Energy Manager 60A 3-Phase PDU 46M4167 IBM 1U 9 C19/3 C13 Switched and Monitored 30A 3-Phase PDU 46M4116 IBM 0U 24 C13 Switched and Monitored 30A PDU 46M4119 IBM 0U 24 C13 Switched and Monitored 32A PDU 46M4134 IBM 0U 12 C19/12 C13 Switched and Monitored 50A 3-Phase PDU 46M4137 IBM 0U 12 C19/12 C13 Switched and Monitored 32A 3-Phase PDU Enterprise PDUs 71762MX IBM Ultra Density Enterprise PDU C19 PDU+ (WW) 71762NX IBM Ultra Density Enterprise PDU C19 PDU (WW) IBM System x3250 M4 15 Table 13. Power distribution units (part 2) Part number Description 71763MU IBM Ultra Density Enterprise PDU C19 3-Phase 60A PDU+ (NA) 71763NU IBM Ultra Density Enterprise PDU C19 3-Phase 60A PDU (NA) 39M2816 IBM DPI C13 Enterprise PDU without linecord 39Y8923 DPI 60A Three Phase C19 Enterprise PDU with IEC309 3P+G (208 V) fixed line cord 39Y8941 DPI Single Phase C13 Enterprise PDU without line cord 39Y8948 DPI Single Phase C19 Enterprise PDU without line cord Front-end PDUs 39Y8934 DPI 32 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector 39Y8935 DPI 63 amp/250 V Front-end PDU with IEC 309 2P+Gnd connector 39Y8938 30 amp/125 V Front-end PDU with NEMA L5-30P connector 39Y8939 30 amp/250 V Front-end PDU with NEMA L6-30P connector 39Y8940 60 amp/250 V Front-end PDU with IEC 309 60A 2P+N+Gnd connector Universal PDUs 39Y8951 DPI Universal Rack PDU with US LV and HV line cords 39Y8952 DPI Universal Rack PDU with CEE7-VII Europe LC 39Y8953 DPI Universal Rack PDU with Denmark LC 39Y8954 DPI Universal Rack PDU with Israel LC 39Y8955 DPI Universal Rack PDU with Italy LC 39Y8956 DPI Universal Rack PDU with South Africa LC 39Y8957 DPI Universal Rack PDU with UK LC 39Y8958 DPI Universal Rack PDU with AS/NZ LC 39Y8959 DPI Universal Rack PDU with China LC 39Y8962 DPI Universal Rack PDU (Argentina) 39Y8960 DPI Universal Rack PDU (Brazil) 39Y8961 DPI Universal Rack PDU (India) 0U basic PDUs 46M4122 IBM 0U 24 C13 16A 3-Phase PDU 46M4125 IBM 0U 24 C13 30A 3-Phase PDU 46M4128 IBM 0U 24 C13 30A PDU 46M4131 IBM 0U 24 C13 32A PDU 46M4140 IBM 0U 12 C19/12 C13 60A 3 Phase PDU 46M4143 IBM 0U 12 C19/12 C13 32A 3 Phase PDU IBM System x3250 M4 16 Racks cabinets The server supports the rack cabinets listed in Table 14. Table 14. Rack cabinets Part number Description 201886X IBM 11U Office Enablement Kit 93072PX IBM 25U Static S2 Standard Rack 93072RX IBM 25U Standard Rack 93074RX IBM 42U Standard Rack 93074XX IBM 42U Standard Rack Extension 93084EX IBM 42U Enterprise Expansion Rack 93084PX IBM 42U Enterprise Rack 93604EX IBM 42U 1200 mm Deep Dynamic Expansion Rack 93604PX IBM 42U 1200 mm Deep Dynamic Rack 93614EX IBM 42U 1200 mm Deep Static Expansion Rack 93614PX IBM 42U 1200 mm Deep Static Rack 93624EX IBM 47U 1200 mm Deep Static Expansion Rack 93624PX IBM 47U 1200 mm Deep Static Rack 99564RX IBM S2 42U Dynamic Standard Rack 99564XX IBM S2 42U Dynamic Standard Expansion Rack IBM System x3250 M4 17 Rack options The server supports the rack console switches and monitor kits listed in Table 15. Table 15. Rack options Part number Description Monitor kits and keyboard trays 17231RX IBM 1U 17" Flat Panel Console Kit with Optical Drive Bay 17233RX IBM 1U 15" Flat Panel Console Kit 17235RX IBM Rack Keyboard Tray Console switches 1754D2X IBM Global 4x2x32 Console Manager (GCM32) 1754D1X IBM Global 2x2x16 Console Manager (GCM16) 1754A2X IBM Local 2x16 Console Manager (LCM16) 1754A1X IBM Local 1x8 Console Manager (LCM8) Console cables 43V6147 IBM Single Cable USB Conversion Option (UCO) 39M2895 IBM USB Conversion Option (UCO) - 4 Pack 39M2897 IBM Long KVM Conversion Option (KCO) - 4 Pack 46M5383 IBM Virtual Media Conversion Option Gen2 (VCO2) For more information, see the following IBM Redbooks® publication at-a-glance guides:  IBM 1754 LCM8 and LCM16 Local Console Managers http://www.redbooks.ibm.com/abstracts/tips0788.html  IBM GCM16 and GCM32 Global Console Managers http://www.redbooks.ibm.com/abstracts/tips0772.html IBM System x3250 M4 18 Warranty options The IBM System x3250 M4 has a 3-year onsite warranty with 9x5/next-business-day terms. IBM offers warranty service upgrades through IBM ServicePacs. The IBM ServicePac is a series of prepackaged warranty maintenance upgrades and post-warranty maintenance agreements with a well-defined scope of services, including service hours, response time, term of service, and service agreement terms and conditions. IBM ServicePac offerings are country-specific. That is, each country might have its own service types, service levels, response times, and terms and conditions. Not all covered types of ServicePacs might be available in a particular country. For more information about IBM ServicePac offerings available in your country, see the IBM ServicePac Product Selector at the following web page: https://www-304.ibm.com/sales/gss/download/spst/servicepac Warranty service definitions are explained in more detail in Table 16. Table 16. Warranty service definitions Term Description IBM onsite repair (IOR) A service technician will come to the server's location for equipment repair. 24x7x2 hour A service technician is scheduled to arrive at your customer’s location within two hours after remote problem determination is completed. We provide service around the clock, every day, including IBM holidays. 24x7x4 hour A service technician is scheduled to arrive at your customer’s location within four hours after remote problem determination is completed. We provide service around the clock, every day, including IBM holidays. 9x5x4 hour A service technician is scheduled to arrive at your customer’s location within four business hours after remote problem determination is completed. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays. If after 1:00 p.m. it is determined that onsite service is required, the customer can expect the service technician to arrive the morning of the following business day. For noncritical service requests, a service technician will arrive by the end of the following business day. 9x5 next business day A service technician is scheduled to arrive at your customer’s location on the business day after we receive your call, following remote problem determination. We provide service from 8:00 a.m. to 5:00 p.m. in the customer's local time zone, Monday through Friday, excluding IBM holidays. In general, the types of IBM ServicePacs are:  Warranty and maintenance service upgrades     One, 2, 3, 4, or 5 years of 9x5 or 24x7 service coverage Onsite repair from next business day to 4 or 2 hours (selected areas) One or two years of warranty extension Remote technical support services     One or three years with 24x7 coverage (severity 1) or 9x5/next business day for all severities Installation and startup support for System x servers Remote technical support for System x servers Software support - Support Line  Microsoft or Linux software  VMWare  IBM Director IBM System x3250 M4 19 Physical and electrical specifications Dimensions:     Height: 43 mm (1.7 in) Width: 439 mm (17.3 in) Depth: 576 mm (22.7 in) Weight:  Minimum configuration: 9.3 kg (20.4 lb)  Maximum configuration: 10.7 kg (23.5 lb) Supported environment::  Air temperature:  Server powered on 10.0 to 35.0 °C (50 to 95 degrees F); altitude: 0 to 914.4 m (3,000 ft) 10.0 to 32.0 °C (50 to 89.6 degrees F); altitude: 914.4 m (3,000 ft) to 2,133.6 m (7,000 ft) Server powered off  10.0 to 43.0 °C (50 to 109.4 degrees F); maximum altitude: 2,133.6 m (7,000 ft) Shipping  -40 to 60 °C (-40 to 140 degrees F)  Relative humidity: 8 to 80%      Electrical  300-watt power supply 100 to 127 (nominal) V ac; 50 to 60 Hz; 6.0 A (maximum) 200 to 240 (nominal) V ac; 50 to 60 Hz; 3.0 A (maximum) Redundant 460-watt power supplies  100 to 127 (nominal) V ac; 50 to 60 Hz; 5.3 A (maximum)  200 to 240 (nominal) V ac; 50 to 60 Hz; 2.6 A (maximum)     Input kilovolt-amperes (kVA) (approximately) Minimum configuration: 0.085 kVA Maximum configuration: 0.326 kVA Btu output  Ship configuration: 267 Btu/hr (78 watts)  Full configuration: 1058 Btu/hr (310 watts) Acoustical noise emission level: Sound power levels  6.5 bels (idling)  6.5 bels (operating)     Regulatory compliance The server conforms to the following international standards:        FCC - Verified to comply with Part 15 of the FCC Rules, Class A Canada ICES-003, issue 4, Class A UL/IEC 60950-1 CSA C22.2 No. 69950-1-03 NOM-019 Argentina IEC60950-1 Japan VCCI, Class A IBM System x3250 M4 20           Australia/New Zealand AS/NZS CISPR 22:2009, Class A IEC-60950-1:2001 (CB Certificate and CB Test Report) Taiwan BSMI CNS 13438, Class A; CNS 14336 China CCC (4943-2001), GB 9254-2008 Class A, GB 17625.1:2003 Korea KN22, Class A; KN24 Russia/GOST ME01, IEC-60950-1, GOST R 51318.22-99, GOST R 51318.24-99, GOST R 51317.3.2-2006, GOST R 51317.3.3-99 IEC 60950-1 (CB Certificate and CB Test Report) CE Mark (EN55022 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3) CISPR 22, Class A TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000) Supported operating systems Operating systems supported by the product are: Microsoft          Microsoft Windows Server 2008 R2 Microsoft Windows Server 2008, Web x86 Edition Microsoft Windows Server 2008, Web x64 Edition Microsoft Windows Server 2008, Enterprise x86 Edition Microsoft Windows Server 2008, Enterprise x64 Edition Microsoft Windows Server 2008, Standard x86 Edition Microsoft Windows Server 2008, Standard x64 Edition Windows Small Business Server 2008 Premium Edition Windows Small Business Server 2008 Standard Edition Novell SUSE    SUSE LINUX Enterprise Server 11 with Xen for AMD64/EM64T SUSE LINUX Enterprise Server 11 for AMD64/EM64T SUSE LINUX Enterprise Server 11 for x86 Red Hat    Red Hat Enterprise Linux 5 Server Edition Red Hat Enterprise Linux 5 Server x64 Edition Red Hat Enterprise Linux 5 Server with Xen x64 Edition VMware  VMware ESX 4.1 IBM System x3250 M4 21 Related publications For more information see the following documents:  IBM System x3250 M4 product page http://www.ibm.com/systems/x/hardware/rack/x3250m4/index.html  IBM System x3250 M4 Installation and User's Guide http://ibm.com/support  IBM System x3250 M4 Problem Determination and Service Guide http://ibm.com/support  ServerProven® hardware compatibility page for the x3250 M4 http://www.ibm.com/systems/info/x86servers/serverproven/compat/us/xseries/2583.html  At-a-glance guides for IBM System x servers and options http://www.redbooks.ibm.com/portals/systemx?Open&page=ataglance  IBM System x DDR3 Memory Configurator http://www.ibm.com/systems/x/hardware/ddr3config/  Configuration and Option Guide http://www.ibm.com/systems/xbc/cog/  xRef - IBM System x Reference Sheets http://www.redbooks.ibm.com/xref  IBM System x Support Portal http://ibm.com/support/entry/portal/ http://ibm.com/support/entry/portal/Downloads/Hardware/Systems/System_x/System_x3250_M4 IBM System x3250 M4 22 Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead. However, it is the user's responsibility to evaluate and verify the operation of any non-IBM product, program, or service. IBM may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to: IBM Director of Licensing, IBM Corporation, North Castle Drive, Armonk, NY 10504-1785 U.S.A. The following paragraph does not apply to the United Kingdom or any other country where such provisions are inconsistent with local law: INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice. Any references in this information to non-IBM Web sites are provided for convenience only and do not in any manner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this IBM product and use of those Web sites is at your own risk.IBM may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or other publicly available sources. IBM has not tested those products and cannot confirm the accuracy of performance, compatibility or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be addressed to the suppliers of those products. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products. All of these names are fictitious and any similarity to the names and addresses used by an actual business enterprise is entirely coincidental. Any performance data contained herein was determined in a controlled environment. Therefore, the results obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurement may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment. COPYRIGHT LICENSE: This information contains sample application programs in source language, which illustrate programming techniques on various operating platforms. You may copy, modify, and distribute these sample programs in any form without payment to IBM, for the purposes of developing, using, marketing or distributing application programs conforming to the application programming interface for the operating platform for which the sample programs are written. These examples have not been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. © Copyright International Business Machines Corporation 2011. All rights reserved. Note to U.S. Government Users Restricted Rights -- Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. IBM System x3250 M4 23 This document was created or updated on October 13, 2011. Send us your comments in one of the following ways: Use the online Contact us review form found at: ibm.com/redbooks  Send your comments in an e-mail to: [email protected]  Mail your comments to: IBM Corporation, International Technical Support Organization Dept. HYTD Mail Station P099 2455 South Road Poughkeepsie, NY 12601-5400 U.S.A.  This document is available online at http://www.ibm.com/redbooks/abstracts/tips0812.html . Trademarks IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. These and other IBM trademarked terms are US registered or common law trademarks owned by IBM at the time this information was published. Such trademarks may also be registered or common law trademarks in other countries. A current list of IBM trademarks is available on the Web at http://www.ibm.com/legal/copytrade.shtml The following terms are trademarks of the International Business Machines Corporation in the United States, other countries, or both: DPI® IBM Systems Director Active Energy Manager™ IBM® Redbooks® Redpaper™ Redbooks (logo)® ServerProven® ServicePac® System x® The following terms are trademarks of other companies: Microsoft, Windows, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both. Intel Xeon, Intel, Intel logo, Intel Inside logo, and Intel Centrino logo are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. IBM System x3250 M4 24