Preview only show first 10 pages with watermark. For full document please download

5opzv350 - Ultracell

   EMBED


Share

Transcript

5OPzV350 2V 350AH OPzV - UzV 5OPzV350 Physical Specification Part Number: 5OPzV350 Length: 124 ± 3 mm ( 4.88 inches ) Width: 206 ± 3 mm ( 8.11 inches ) Container Height: 471 ± 3 mm ( 18.5 inches ) Total Height (with terminal): 506 ± 3 mm ( 19.9 inches ) Approx 29.0 kg (63.9lbs) Approx Weight: Specifications Terminal Type Container Material Rated Capacity Nominal Voltage 2V Nominal Capacity (20HR) 350.0Ah@10hr to 1.80V/cell Standard Terminal F11 Optional Terminal - Standard Option ABS Flame Retardant Option (FR) ABS (UL94:VO) 430.5 AH/430.5A (100 hr, 1.80V/cell, 20°C/68°F) 350 AH/35.0A (10hr,1.80V/cell, 20°C / 68°F) 305 A H/61.0A (5hr,1.75V/cell, 20°C / 68°F) 270.4 AH/90.1A (3hr,1.75V/cell, 20°C / 68°F) 199 AH/199A (1hr,1.60V/cell, 20°C / 68°F) Max Discharge Current 2800A (5s) Internal Resistance Approx 0.9mΩ Discharge Characteristics Operating Temp. Range Discharge: -20 ~ 55°C (-4 ~ 131°F) Charge: 0 ~ 40°C (32 ~ 104°F) Storage: -20 ~ 50°C (-4 ~ 122°F) Nominal Operating Temp. Range - Cycle Use Inital Charging Current less than 70.0A.Voltage 2.40V ~ 2.50V at 20°C (68°F) Temp. Coefficient -5mV/°C Standby Use No limit on Initial Charging Current Voltage 2.25V ~ 2.30V at 20°C (68°F) Temp. Coefficient -3mV/°C Capacity affected by Temperature Design Floating Life at 20°C 20 Years Self Discharge <2% pre month @ 20°C (68°F) 40°C (104°F) 103% 25°C (77°F) 100% 0°C (32°F) 86% Dimensions F11 Terminal 1 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE ISO9001 Constant Current Discharge (Amperes) at 20 0C (68 0F ) F.V/Time 10min 15min 30min 1h 2h 3h 5h 8h 10h 1.85V/cell 274 253 206 157 105 81.0 55.5 38.7 32.8 1.80V/cell 337 306 240 176 115 88.1 59.8 41.4 35.0 1.75V/cell 399 343 256 183 119 90.1 61.0 42.1 35.6 1.70V/cell 448 374 271 191 122 91.9 61.9 42.7 36.0 1.65V/cell 481 395 282 196 124 93.6 62.9 43.2 36.3 1.60V/cell 503 409 289 199 126 94.7 63.5 43.5 36.6 Constant Power Discharge (Watts) at 20 0C (68 0F ) F.V/Time 10min 15min 30min 1h 2h 3h 5h 8h 10h 1.85V/cell 510 475 394 303 204 158 109 76.7 65.2 1.80V/cell 616 567 455 339 223 171 117 82.0 69.5 1.75V/cell 717 626 480 350 228 174 119 83.2 70.5 1.70V/cell 790 673 503 362 233 177 121 84.1 71.2 1.65V/cell 833 700 518 369 237 180 122 84.9 71.8 1.60V/cell 855 715 526 373 239 181 123 85.3 72.2 Charging Characteristics Discharge Characteristics 2.50 25 Equ alin g cha rge v oltage for m ax. 1 6 hou rs 2.40 C harging time in hours C harge voltage (V /cell) 2.45 2.35 2.30 2.25 Floa t voltage + /- 1% 2.20 2.15 2.10 -20 -10 30 20 10 0 A 10 B A 0.2C 10 0 50 40 0 0.1C 20 B 10 0 50 Tempera ture ( C ) 100 Depth of discharge in % of C For continuous charging we recommend a voltage of 2.25 V. The charging voltage must be compensated to the curve for acontinuously different battery ambient temperature. 10 Charge voltage: A 2.25 V/cell B State of charge 2.40 V/cell 100 % State of charge 90 % Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 22 100 20 Life expectancy (year) Available capacity( % ) 110 105 95 90 85 80 75 70 C 10 C5 C3 C1 65 60 55 50 45 18 Charging voltage 2.25V/cell 16 14 12 10 5 40 35 30 -20 -15 -5 -10 5 0 10 15 20 Ambient temperatu re( 25 20 68 30 ) 40 104 30 86 0 Ac c.t o IE C 8 96 -2 ( 20 C / 68 F) 80 70 60 50 40 30 20 3000 3500 4000 4500 5000 5500 6000 6500 Nu mb er of Cy cle s 2 Residu al averag e capacit y in % of C 120 90 Available capacity / % E xtrac ted c apac ity in % 100 2500 Ultracell (UK) Ltd | Vesty Business Park | Vesty Road | Liverpool | L30 1NY | United Kingdom Tel: +44 (0) 151 523 2777 Fax: +44 (0) 151 523 0855 Email: [email protected] www.ultracell.co.uk C F O General Relation of Capacity VS. Storage Time 0 2000 0 Battery temperature Cycle Life in Relation to Depth of Discharge 10 1500 50 122 10 100 80 10 60 30 40 40 20 20 0 5 10 15 20 25 St or ag e t im e ( mo nths ) ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE ISO9001