Preview only show first 10 pages with watermark. For full document please download

6 3 4 1

   EMBED


Share

Transcript

90 60 30 CC C Orange Brown Yellow Red Yellow Purple Brown Pink Red 39 Black Blue Black 3 Blue Yellow 1 L1 L2 L3 58 L3 L3 Red C COM A Red Ground Crankcase Heater G R E Y 40 L2 L3 Y Yo C Phase Monitor Disch. Line Tstat R Low Pressure Bypass Low Pressure Control Black 24VAC 3 NC C Defrost Control R 2 Defrost CC Control LOR-1 L0 Lockout Relay Control LI 1 High Pressure Control #1 L B B W2 W2 Defrost Sensor SENSOR LOR-2 DFC-1 DFC-2 RV Reversing Valve C Y1 L1 L2 L3 Ground Lug 29 G Red 44 35 Capacitor Black (High Spd) High Speed Solenoid NC AC SW High Pressure Control #2 W3 2 Current Sensor 45 Out. Fan Relay C Y AC DELAY ON BREAK 35 40 51 Yellow Compressor Contactor COM Terminal Block 24 18 20 22 16 24 14 26 12 28 10 30 Purple 30 W1 18 25 O1 Low Voltage Term. Block 20 B Red 52 5 Y1 Black 15 L DH L1 Current Sensor 24 VAC W2 W3 A Low Ambient Control NC L Red C Outdoor Fan Motor Capacitor L3 C Transformer Y Transformer 16 Black C TB L1 Compressor Red Blue Red Black Outdoor Fan Motor (see chart) 480V Black Yellow 12 14 10 Blue 12 HPS 7 Black 63 8 C 6 1 4 3 6 Pin Plug for Heater Package 15 10 2 14 9 6 12 3 1 16 Pin Plug for Indoor Blower Motor Ladder Diagram Yellow 62 Fuses Fuse Block 61 Yellow Brown A Black Wire Identification numbers Wires Connect 99 for Bard use only. if Option Not Used Factory Field Optional Red Red Red (Low Spd) Black 62 CURRENT TRIP SETPOINT Black Pink 46 R 53 T2 T3 NO NC COM 41 Pressure Transducer T1 12 Black 12 AWG WIRE 33 Compressor Contactor Aux. Black/White 70 NC 42 6 Yellow Crankcase Heater High Speed Solenoid 20 21 22 33 34 35 Low Ambient Control (Opt.) 1 2 3 4 7 8 9 9 15 Black L1 L2 L3 C 3 20 Blue 22 2 Yellow Red Black/Red Black T2 19 1000 Red T3 Compressor A 10 Blue T1 Low Pressure Control 10 Low Pressure Bypass 13 1 59 60 11 54 500 Black Blue Black Yout Y C 55 Phase Monitor SECONDS 38 57 64 46 Red Transformer L2 Aux. 56 Terminal Block Yellow L2 C A Hi Pressure Control #1 Red Yellow L2 NC 65 30 Yellow Orange Red Hi Pressure Control #2 Discharge Line TStat Fuse L1 L2 L3 Black Out. Fan Relay Red 17 Reversing Coil Sensor Valve 4 5 Pin Plug for Indoor Blower Motor 4 5 3 Outdoor Fan Relay Brown 67 Yellow Black 17 3 Blue Red/White 23 22 1 Low Voltage Term. Block Y 6 Line 3 to power source or optional heater package C 2 Line 2 to power source or optional heater package Black SENSOR W2 L1 4 Line 1 to power source or optional heater package Blue R L RV Black Blue B 5 Fuse Yellow R 3 460-60-3 Power Source 6 Pin Plug for Optional 34 Heater Package 5 Pin Plug 47 9 L1 L1 Compressor Contactor Blue LO 14 Move Red Wire to 208V tap for 208V operation 22 6 Yellow 59 2 15 10 12 Black NC 1 Red NO COM Indoor Blower Motor 16 Pin Plug 48 3 SEN JMP SPEEDUP 43 Note: Factory set on 60 min. cycle. Reconnect on 30 min. for 30 min. cycle or 90 min. for 90 min. cycle. Defrost Control Transformer Black Black Standard Diagram High Voltage Low Voltage ! WARNING USE COPPER CONDUCTORS ONLY SUITABLE FOR AT LEAST 75° C. ! DANGER *ELECTRICAL SHOCK HAZARD *DISCONNECT POWER BEFORE SERVICING. Bard Mfg. Co. Bryan, Ohio 4096-335 E