Preview only show first 10 pages with watermark. For full document please download

6-gfm Series

   EMBED


Share

Transcript

6-GFM Series 6-GFM-80 Main Applications Dimensions: Backup power for telecom and signal system Military field, railway system, power system UPS & emergency lighting system Fire alarm and security system Benefits 10 years design life Safely and reliably sealed High energy density, low internal resistance and low discharge rate Excellent charging acceptability and high sealed reaction effciency Technical Parameters Attain Certificate: Normal Voltage 12V Capacity 80Ah @ 10hr to 1.80V per cell @ 25℃(77℉) Weight Approx. 23.5kg (51.7lbs) ISO14001 Dimensions Length:258mm Width:168mm Height:208mm Total Height:214mm ISO18001 Internal Resistance (full charged) Approx. 5.1mΩ@ 25℃(77℉) Maximum Discharge Current 496A (5sec) Self Discharge @ 25℃ (77℉) Less than 8 % after 90 days storage Operating Temperature Range Discharge: -40℃~50℃(-40℉~122℉) Charge: -20℃~45℃(-4℉~113℉) Storage: -20℃~40℃(4℉~104℉) Recommended Operating Temperature 15℃~25℃(59℉~77℉) Maximum Charging Current Limited 16A Charging Voltage @25˚C(77˚F) Float: 2.25 V/cell, Temps coefficient -3 mV/℃ Cycle: 2.35 V/cell Terminal M6 Container Materials ABS/ABS V0 (Optional) Capacity Affected by Temperature 105 % @ 40℃ 85 % @ 0℃ 60 % @ -20℃ Design Life @25°C(77˚F) 10 years ISO9001 UL CE Technical Features Adopt high strength ABS plastic, compact structure for battery container and valve, good impact resistance, and shock resistant performance Adopt multi-element alloy grids, low internal resistance, good corrosion resistance ability and charging acceptability. New production process for plate, improve the utilization of active material High-purity electrolyte and special additives(ZL02112896.0),low self-discharge Multi-layer seal technology and special seal glue, no leakage and no acid mist escape, safe and reliable 6-GFM Series 6-GFM-80 Constant Current Discharge Characteristics Unit: A (25ºC, 77ºF) F.V/Time 15min 30min 1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 1.90V/cell 76.6 59.5 37.9 26.9 19.5 15.6 13.3 11.7 9.2 7.8 1.85V/cell 92.6 67.5 40.2 28.5 19.8 15.8 13.4 12.2 9.4 7.9 1.80V/cell 107.8 73.2 43.2 29.1 20.0 16.0 13.6 12.4 9.7 8.0 1.75V/cell 116.2 77.4 44.1 29.4 20.3 16.2 13.8 12.5 9.9 8.1 1.70V/cell 122.6 81.8 45.6 29.8 20.8 16.6 14.1 12.6 10.0 8.3 1.65V/cell 128.1 84.8 47.0 30.6 21.0 16.8 14.3 12.7 10.1 8.4 Constant Power Discharge Characteristics Unit: W/cell (25ºC, 77ºF) F.V/Time 15min 30min 1hr 2hr 3hr 4hr 5hr 6hr 8hr 10hr 1.90V/cell 147.1 115.1 74.5 53.4 42.1 33.1 28.5 23.7 18.6 15.9 1.85V/cell 174.2 128.7 77.6 55.8 43.0 33.3 28.7 24.6 18.8 15.9 1.80V/cell 199.6 136.0 82.3 56.5 43.4 33.8 28.8 24.8 19.4 16.0 1.75V/cell 211.7 142.2 83.2 56.8 43.7 34.1 29.0 25.0 19.8 16.2 1.70V/cell 217.7 148.4 84.7 57.1 44.1 34.3 29.3 25.2 20.0 16.6 1.65V/cell 220.8 151.8 86.2 58.2 44.9 34.4 29.8 25.4 20.2 16.8 Performance Curve: Current Voltage ( I10A ) (V) Constant Voltage Charge Characteristics@25 ℃ (%) 2.2 2.1 2.0 1.9 1.80 2.40 1.50 2.30 1.20 2.20 0.90 2.10 0.60 2.00 0.30 1.90 Charge Voltage 100 Battery Capacity 75 50 50% DOD 100% DOD 25 20HR 1.8 0.5HR 1.7 0.01 0.1 0.5 2HR 1HR 5HR 8HR 10HR 0 Charge Current 1.80 1 2 5 10 4 0 20 8 12 16 20 24 Time( h ) Discharge time (h) Capacity at Different Temperature @25℃ Curve of Self-discharge at Different Temperature 140 120 Capacity(%) Capacity(%) Capacity 10HR 8HR 100 4HR 80 2HR 60 100 10℃ 80 20℃ 60 40℃ 30℃ 40 40 20 20 0 -20 -10 0 10 20 30 40 50 0 3 6 9 12 Temperature℃ Declaration: This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact CHINASHOTO for the latest information. 15 18 21 24 Storage Time (months) Welcome to Visit: www.chinashoto.com V2.0 20170310EN Voltage(V) Discharge Performance at Different Discharge Rate