Tubular Gel Battery 6 OPzV420 (2V420AH) Specification Nomial Voltage 2V Capacity 420.0Ah@10hr to 1.80V/cell Dimension Length Width Container Height Total Height (with Terminal) Approx Weight Approx 34.0 kg (75.0lbs) Container Material ABS 2mm (5.17 inches) 3mm (8.11 inches) 3mm (18.5 inches) 3mm (19.9 inches) 0 0 (10hr,1.80V/cell,20 C/68 F) 420 AH/42.0A Rated Capacity 145 206 471 506 365.5 A H/73.1A (5hr,1.75V/cell,200C/680F) 324 AH/108A (3hr,1.75V/cell,200C/680F) 239 AH/239A (1hr,1.60V/cell,20 C/68 F) 0 Max. Discharge Current 3360A (5s) Internal Resistance Approx 0.8mÙ Operating Temp.Range Discharge : -20 55 C (-4 131 F) 0 0 Charge : 0 40 C (32 104 F ) 0 0 Storage : -20 50 C (-4 122 F) 0 Applications 0 Solar energy, wind energy Electric power, nuclear power Communication Ship, maritime affairs UPS, medical facilities and emergency lighting Situation with high environmental protection and energy-saving Better safety performance and reliability Designed service life of 20 years 0 Initial Charging Current less than 105.0A.Voltage Cycle Use 0 0 0 2.40V~2.50V at 20 C(68 F)Temp. Coefficient -5mV/ C No limit on Initial Charging Current Voltage Standby Use 2.25V~2.30V at 200 C(680 F)Temp. Coefficient -3mV/0C <2% pre month @ 20 0 C(68 0 F) Self-discharge Main Technical Advantages Plate: positive plate adopts tubular plate which can prevent active material falling, and adopts multi-component alloy frame. have fine corrosion-resisting performance and long service life. Negative plate adopts special radiated structure. Separator: adopt special micro-pore PVC-SiO 2 separator from Europe AMER-SIL Company, separator have big porosity and low resistance. Electrolyte: adopts Germany gas silicon dioxide,electrolyte in gel state in the battery without flowing,leakage and lamination can be avoided. Safety valve: adopt Germany technology,constant opening and closing,accumulator case expansion,damage and electrolyte dry up can be avoided. 0 0 Constant Current Discharge (Amperes) at 20 C (68 F ) F.V/Time 10min 15min 30min 1h 2h 3h 5h 8h 10h 1.85V/cell 329 303 248 188 126 97.2 66.5 46.4 39.3 1.80 V/cell 405 367 289 212 139 106 71.8 49.7 42.0 1.75 V/cell 479 411 308 220 142 108 73.1 50.6 42.7 1.70 V/cell 537 449 326 229 146 110 74.3 51.2 43.2 1.65 V/cell 577 474 339 235 149 112 75.4 51.8 43.6 1.60 V/cell 604 490 347 239 151 114 76.2 52.3 43.9 8h 10h 0 0 Constant Power Discharge (Watts) at 20 C (68 F ) F.V/Time 10min 15min 30min 1h 2h 3h 5h 1.85V/cell 612 570 473 363 245 190 131 92 78.2 1.80 V/cell 740 680 546 407 268 206 141 98.4 83.4 1.75 V/cell 860 751 576 420 274 209 143 99.8 84.6 1.70 V/cell 948 808 604 434 280 213 145 101 85.4 1.65 V/cell 1000 840 621 443 284 216 146 102 86.2 1.60 V/cell 1026 857 631 448 286 217 147 102 86.6 Specifications subject to change without notice. 1 Dimensions T11 Terminal Temperature Effects in Relation to Charge Voltage Charging Characteristics 2.50 25 A Charging time in hours Charge voltage (V/cell) 2.45 Equaling charge voltage for max. 16 hours 2.40 2.35 2.30 2.25 Float voltage +/- 1% 2.20 2.15 0.1C 10 B 20 A B 0.2C 10 10 0 2.10 -20 -10 20 10 0 30 0 50 40 50 100 Depth of discharge in % of C10 0 Temperature( C) Charge voltage: For continuous charging we recommend a voltage of 2.25 V. The charging voltage must be compensated to the curve for acontinuously different battery ambient temperature. A 2.25 V/cell B State of charge 100 % 2.40 V/cell State of charge 90 % Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 110 105 22 Life expectancy (year) Available capacity( % ) 100 95 90 85 80 75 70 C 10 C5 C3 C1 65 60 55 50 45 20 18 Charging voltage 2.25V/cell 16 14 12 10 5 40 35 30 -20 -15 -5 -10 0 5 10 15 Ambient temperature( 20 25 20 68 30 ) 30 86 40 104 0 C F O Battery temperature Cycle Life in Relation to Depth of Discharge 0 General Relation of Capacity VS. Storage Time 0 Acc.to IEC 896-2 (25 C / 77 F) Residual average capacity in % of C 10 120 100 90 Available capacity / % Extracted capacity in % 50 122 80 70 60 50 40 30 100 80 10 60 30 40 20 40 20 20 10 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 0 6500 5 10 15 Storage time (months) Number of Cycles Sales Office Website:www.bullspower.net 2 20 25