Transcript
6004 and 6008 Wave Division Multiplexer Installation Guide
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912373 Rev D
Overview This document provides steps necessary to install and configure Canoga Perkins’ passive CWDM products correctly. The passive CWDMs come in variations of 4, 5, 8 and 9 channels. The 4 and 5 channel versions occupy one slot in the UCS 1000, UCS 1001 and UCS 1050 chassis while the 8 and 9 channel versions occupy two slots in the UCS 1000 chassis only. All connections are made from the front of the units and the optical ports are marked “Tx” for transmit and “Rx” for receive. Installation Ensure that there is no visible damage to the CWDM module. Insert the CWDM module into any slot in the chassis. See figures 1 through 3.
Figure 1 Model 6008 installed in UCS 1000 with 8 active transponders
Figure 2 Model 6004 installed in UCS 1001
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912373 Rev D
Figure 3 Model 6004 installed in UCS 1050
Configuration Be advised that the wavelengths from the active CWDM transponder must coincide with the correct optical port on the 6004 or 6008 Passive CWDM mux/demux. The optical ports are clearly marked “Tx,” (transmit) “Rx,” (receive) “the optical wavelength,” and “Composite.” Using a singlemode optical jumper, connect the Remote Tx of the active CWDM transponder to the Rx of the corresponding 6004 or 6008 optical port. Use another singlemode optical jumper to connect the Remote Rx of the active CWDM transponder to the Tx of the 6004 or 6008 optical port. For the Composite port of the 6004 or 6008 CWDM mux/demux, connect the Tx and Rx ports as shown in figure 4.
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912373 Rev D
Figure 4 Passive CWDM mux/demux configuration
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912373 Rev D
Technical Specifications Wavelengths 1310nm, 1470nm, 1490nm, 1510nm, 1530nm, 1550nm, 1570nm, 1590nm, 1610nm Insertion Loss (End to End) Model 6004 < 2.5dB Model 6004 with 1310nm <3dB for CWDM wavelengths <1.5dB for 1310nm channel Model 6008 <4.5dB Model 6008 + 1310 wavelength <5dB for CWDM wavelengths <1.5dB for 1310nm channel Optical Connectors SC Physical Dimensions Model 6004 7.9"H x 1.0"W x 10.4"D (201 x 25 x 264mm) Model 6008 7.9”H x 2.0W" x 10.4"D (201 x 50 x 264mm) Weight Model 6004 1.2 lbs. (0.54kg) Model 6008 2.4 lbs. (1.08kg) Operating Environment Temperature 0° to 50°C Humidity Up to 95% (Noncondensing) REGULATORY COMPLIANCE UL60950/CSA C22.2 No. 60950 IEC 60950 IEC 60825-1 FCC Part 15 Class A, AS/NZS3548, CS-003 EN55022, EN55024 NEBS Level 3 Tested and Certified Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912373 Rev D
Warranty Information Current Warranty information is available on-line in the Client Login Area of the Canoga Perkins web site (www.canoga.com) or by contacting Technical Support at 800-360-6642 (voice) or
[email protected] (email).
Canoga Perkins Corporation, 20600 Prairie Street, Chatsworth, CA 91311-6008 Phone: (818) 718-6300, FAX (818) 718-6312 www.canoga.com P/N 6912373 Rev D
CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 Web Site: www.canoga.com Email:
[email protected]