Transcript
GNR 22.5MM Series • Current ratings 10, 20 and 30 amps • Output voltage 24-280 and 48-600 VAC • Direct Bond Copper (DBC) Substrate • LED input status indicator • 100K cycle UL508 Endurance Rating • UL / CSA / TUV Approved, CE Compliant • EMC Compliant Level 3 • DIN-RAIL or Panel Mount • Zero-Crossing or Random Turn-on
PRODUCT SELECTION Control Voltage 4-32 VDC 90-140 VAC 1800-280 VAC
10A
20A
30A
GNR10DHZ GNR10BHZ GNR10AHZ
GNR20DHZ GNR20BHZ GNR20AHZ
GNR30DHZ GNR30BHZ GNR30AHZ
AVAILABLE OPTIONS
OUTPUT SPECIFICATIONS (Voltage) (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk, t = 1 min.] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Static off-state dv/dt (Vµs, Ta =25°C) (2)
GNR10
GNR20/30
24-280 600 0.1 500
48-600 1100 0.1 500
OUTPUT SPECIFICATIONS (Current) (1) Description
GNR10x
GNR20x
GNR30x
Maximum Load Current [Arms] Minimum Load Current [mArms] 1 cycle surge current (50Hz) 1 cycle surge current (60Hz) 1 second surge current (Apk. Ta = 25°C) 50/60 Hz Forward Voltage Drop (Vpk @ Imax, Ta = 25°C) I²T (50Hz, 1/2 cycle) I²T (60Hz, 1/2 cycle) HP Ratings at 120V / FLC HP Ratings at 240V / FLC Min/Max stranded wire Min/Max solid wire
10A 100 190 200 65 1.5 180 160 NA NA 16/8 AWG 16/10 AWG
20A 100 275 300 85 1.35 380 370 1/2 / 9.8A 1 / 8A 16/8 AWG 16/10 AWG
30A 100 710 750 150 1.35 2520 2320 3/4 / 13.8A 1 / 8A 16/8 AWG 16/10 AWG
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
INPUT SPECIFICATIONS (1) Description Input Voltage Range (3) Minimum Turn-On Voltage Drop out Voltage Maximum Input Current Minimum input current (for on-state) Input Resistance Turn-on time (4) Turn-off time Min/Max stranded/solid wire
GNRxxDx
GNRxxBx
GNRxxAx
4-32 VDC 4.0 VDC 1.0 VDC 19mA 16mA Current Regulated 8.33ms 8.33ms 24/16AWG
90-140VAC 90 Vrms 10 Vrms 23mArms 6mArms Current Regulated 20ms 30ms 24/16AWG
180-280VAC 180Vrms 10 Vrms 23mArms 8mArms Current Regulated 20ms 30ms 24/16AWG
GENERAL SPECIFICATIONS Description
Parameters
Ambient Operating Temperature Range (3) Ambient Storage Temperature Range Input to output isolation Input/output to ground isolation Input to output capacitance Housing Material Status Indicating Display Weight (typical)
-20 to 80 °C -40 to 100 °C 4000 Vrms 2500 Vrms 8 pF UL 94V0 (self extinguishing) Green LED 0.5lbs (225 g)
GENERAL NOTES 1) 2) 3) 4)
All parameters at 25°C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-433, paragraph 13.11.1 For 180-280VAC control, maximum Ambient operating temperature is 60°C Random turn-on time R suffix is 100µs (for DC control only).
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
THERMAL DERATE INFORMATION
AGENCY APPROVALS IEC 62314 IEC 60068-2-6 : 35mm/10-55Hz IEC 60068-2-27 : 15G/11ms IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3 CISPIR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments E79183,
LR38595
Rev. 061310
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
ANNEX - ENVIROMENTAL INFORMATION
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com