Preview only show first 10 pages with watermark. For full document please download

60ssr Gnr

   EMBED


Share

Transcript

GNR 22.5MM Series • Current ratings 10, 20 and 30 amps • Output voltage 24-280 and 48-600 VAC • Direct Bond Copper (DBC) Substrate • LED input status indicator • 100K cycle UL508 Endurance Rating • UL / CSA / TUV Approved, CE Compliant • EMC Compliant Level 3 • DIN-RAIL or Panel Mount • Zero-Crossing or Random Turn-on PRODUCT SELECTION Control Voltage 4-32 VDC 90-140 VAC 1800-280 VAC 10A 20A 30A GNR10DHZ GNR10BHZ GNR10AHZ GNR20DHZ GNR20BHZ GNR20AHZ GNR30DHZ GNR30BHZ GNR30AHZ AVAILABLE OPTIONS OUTPUT SPECIFICATIONS (Voltage) (1) Description Operating Voltage (47-63Hz) [Vrms] Transient Overvoltage [Vpk, t = 1 min.] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Static off-state dv/dt (Vµs, Ta =25°C) (2) GNR10 GNR20/30 24-280 600 0.1 500 48-600 1100 0.1 500 OUTPUT SPECIFICATIONS (Current) (1) Description GNR10x GNR20x GNR30x Maximum Load Current [Arms] Minimum Load Current [mArms] 1 cycle surge current (50Hz) 1 cycle surge current (60Hz) 1 second surge current (Apk. Ta = 25°C) 50/60 Hz Forward Voltage Drop (Vpk @ Imax, Ta = 25°C) I²T (50Hz, 1/2 cycle) I²T (60Hz, 1/2 cycle) HP Ratings at 120V / FLC HP Ratings at 240V / FLC Min/Max stranded wire Min/Max solid wire 10A 100 190 200 65 1.5 180 160 NA NA 16/8 AWG 16/10 AWG 20A 100 275 300 85 1.35 380 370 1/2 / 9.8A 1 / 8A 16/8 AWG 16/10 AWG 30A 100 710 750 150 1.35 2520 2320 3/4 / 13.8A 1 / 8A 16/8 AWG 16/10 AWG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com INPUT SPECIFICATIONS (1) Description Input Voltage Range (3) Minimum Turn-On Voltage Drop out Voltage Maximum Input Current Minimum input current (for on-state) Input Resistance Turn-on time (4) Turn-off time Min/Max stranded/solid wire GNRxxDx GNRxxBx GNRxxAx 4-32 VDC 4.0 VDC 1.0 VDC 19mA 16mA Current Regulated 8.33ms 8.33ms 24/16AWG 90-140VAC 90 Vrms 10 Vrms 23mArms 6mArms Current Regulated 20ms 30ms 24/16AWG 180-280VAC 180Vrms 10 Vrms 23mArms 8mArms Current Regulated 20ms 30ms 24/16AWG GENERAL SPECIFICATIONS Description Parameters Ambient Operating Temperature Range (3) Ambient Storage Temperature Range Input to output isolation Input/output to ground isolation Input to output capacitance Housing Material Status Indicating Display Weight (typical) -20 to 80 °C -40 to 100 °C 4000 Vrms 2500 Vrms 8 pF UL 94V0 (self extinguishing) Green LED 0.5lbs (225 g) GENERAL NOTES 1) 2) 3) 4) All parameters at 25°C unless otherwise specified. Off-State dv/dt test method per EIA/NARM standard RS-433, paragraph 13.11.1 For 180-280VAC control, maximum Ambient operating temperature is 60°C Random turn-on time R suffix is 100µs (for DC control only). Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com MECHANICAL SPECIFICATIONS WIRING DIAGRAM Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com THERMAL DERATE INFORMATION AGENCY APPROVALS IEC 62314 IEC 60068-2-6 : 35mm/10-55Hz IEC 60068-2-27 : 15G/11ms IEC 61000-4-2 : Electrostatic Discharge – Level 3 IEC 61000-4-3 : Radiated Electromagnetic Noise – Level 3 IEC 61000-4-4 : Electrically Fast Transients – Level 3 IEC 61000-4-5 : Electrical Surges – Level 3 IEC 61000-4-6 : Conducted Electromagnetic Noise – Level 3 CISPIR 11 – Class A: Allowable Levels of Conducted and Radiated Noise for Industrial Environments E79183, LR38595 Rev. 061310 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ANNEX - ENVIROMENTAL INFORMATION Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com