Transcript
61WG/30WG 020-090 Pro-Dialog+ Control
Operation instructions
Contents 1 - SAFETY CONSIDERATIONS................................................................................................................................................ 3 1.1 - General...................................................................................................................................................................................... .3 1.2 - Avoid electrocution.................................................................................................................................................................. .3 2 - GENERAL DESCRIPTION..................................................................................................................................................... 3 2.1 - General...................................................................................................................................................................................... .3 2.2 - Abbreviations used.................................................................................................................................................................. .3 3 - HARDWARE DESCRIPTION................................................................................................................................................ 3 3.1 - General...................................................................................................................................................................................... .3 3.2 - Electrical supply to boards...................................................................................................................................................... .4 3.3 - Light emitting diodes on boards............................................................................................................................................. .4 3.4 - The sensors................................................................................................................................................................................ .4 3.5 - The controls............................................................................................................................................................................... .4 3.6 - Connections at the user terminal block................................................................................................................................. .4 4. SETTING UP PRO-DIALOG+ CONTROL........................................................................................................................... 6 4.1 - General features....................................................................................................................................................................... .6 4.2 - Default screen characteristics................................................................................................................................................. .6 4.3 - Password screens...................................................................................................................................................................... .6 4.4 - Menu screen characteristics.................................................................................................................................................... .6 4.5 - Data screen or configurable parameter characteristics....................................................................................................... .6 4.6 - Parameter modification........................................................................................................................................................... .7 4.7 - Operating mode screen........................................................................................................................................................... .7 4.8 - Menu tree structure.................................................................................................................................................................. .8 4.9 - Detailed menu description...................................................................................................................................................... .9 5 - PRO-DIALOG+ CONTROL OPERATION....................................................................................................................... 16 5.1 - Start/stop control.................................................................................................................................................................... .16 5.2 - Heating/cooling/standby operation...................................................................................................................................... .16 5.3 - Heat exchanger water pump control................................................................................................................................... .17 5.4 - Control interlock contact...................................................................................................................................................... .17 5.5 - Control point.......................................................................................................................................................................... .17 5.6 - Capacity control..................................................................................................................................................................... .18 5.7 - Demand limit.......................................................................................................................................................................... .18 5.8 - Night mode.............................................................................................................................................................................. .18 5.9 - Control of a boiler.................................................................................................................................................................. .19 5.10 - Master/slave assembly......................................................................................................................................................... .19 5.11 - Heating module (HDC) control......................................................................................................................................... .19 6 - DIAGNOSTICS - TROUBLESHOOTING.......................................................................................................................... 21 6.1 - General.................................................................................................................................................................................... .21 6.2 - Displaying alarms................................................................................................................................................................... .21 6.3 - Resetting alarms..................................................................................................................................................................... .21 6.4 - Alarm codes............................................................................................................................................................................ .22
The cover graphics are solely for illustration and forms no part of any offer for sale or any sale contract. The manufacturer reserves the right to change the design at any time without notice. 2
1 - SAFETY CONSIDERATIONS
2.2 - Abbreviations used
1.1 - General
In this manual, the refrigerant circuits are called circuit A and circuit B. The compressors in circuit A are labelled A1, A2 and A3. Those in circuit B are B1 and B2.
Installation, start-up and servicing of equipment can be hazardous if certain factors particular to the installation are not considered: operating pressures, presence of electrical components and voltages and the installation site (elevated plinths and built-up up structures). Only properly qualified installation engineers and highly qualified installers and technicians, fully trained for the product, are authorised to install and start-up the equipment safely. During all servicing operations all instructions and recommendations which appear in the installation and service instructions for the product, as well as on tags and labels fixed to the equipment and components and accompanying parts supplied separately, must be read, understood and followed. • Apply all standard safety codes and practices. • Wear safety glasses and gloves. • Use the proper tools to move heavy objects. Move units carefully and set them down gently.
The 61WG/30WG units however have only one circuit A with one or two compressors (A1, A2). The following abbreviations are used frequently: Carrier Comfort Network CCN DHW Domestic hot water HDC Heating device control LED Light Emitting Diode LEN Internal communication bus linking the main board to the slave boards SCT Saturated condensing temperature SHC Space heating control SST Saturated suction temperature EXV Electronic expansion valve PD-AUX Auxiliary input/output board
1.2 - Avoid electrocution
3 - HARDWARE DESCRIPTION
Only personnel qualified in accordance with IEC (International Electrotechnical Commission) recommendations may be permitted access to electrical components. It is particularly recommended that all sources of electricity to the unit be shut off before any work is begun. Shut off the main power supply at the main circuit breaker or isolator.
3.1 - General
IMPORTANT: This equipment conforms to all applicable codes regarding electromagnetic compatibility. 2 - GENERAL DESCRIPTION 2.1 - General
The control system consists of an NRCP2-BASE board and a user interface. All boards communicate via an internal LEN bus. The NRCP2-BASE board continuously manages the information received from the various pressure and temperature probes. The NRCP2-BASE master board contains the program that controls the unit. The user interface includes an alphanumeric seven-line display, two LEDs with five navigation keys as well as a contrast control wheel.
The 61WG/30WG units have one refrigerant circuit with one or two compressors. Pro-Dialog is an electronic control system to regulate water-cooled units with or without hydronic module of the following types: • 61WG non-reversible heat pumps • 30WG water-cooled liquid chillers. Pro-Dialog controls: • compressor start-up to control the water loop • fixed or variable-flow pumps to optimise the operation of the refrigerant circuit As standard Pro-Dialog offers three on/off commands: • Local - on/off command using the keyboard • Remote - wired on/off command using volt-free contacts • Network - Carrier Comfort Network (CCN) on/off command. The command type is selected in advance by keyboard.
3
Control board
Green LED
Unit has stopped
Contrast control wheel
Unit starts up Unit in operation
Back to the previous screen
Red LED
No alarm Warning
Circuit or complete unit error
Up/Down key - Navigation - Modification
On/off key
Enter key
- Unit stopped - List of available operating modes (only in local mode)
3.2 - Electrical supply to boards All boards are supplied from a common 24 V a.c. supply referred to earth. CAUTION: Maintain the correct polarity of the power supply connection of the boards, to ensure that they are not damaged. In the event of a power supply interrupt, the unit restarts automatically without the need for an external command. However, any faults active when the supply is interrupted are saved and may in certain cases prevent a circuit or unit from restarting. 3.3 - Light emitting diodes on boards All boards continuously check and indicate the proper operation of their electronic circuits. A light emitting diode (LED) lights on each board when it is operating properly. • The red LED that flashes for a two-second period - one second on, one second off - indicates correct operation. A different rate indicates a board or a software failure. • The green LED flashes continuously on all boards to show that the board is communicating correctly over its internal bus. If the LED is not flashing, this indicates a LEN bus wiring problem. • The orange LED of the master board flashes during any communication via the CCN bus.
- Validation - Selection access
Water system pressure sensors As an option, two electronic sensors are used to measure the suction and the discharge pressure of the water pump. The water flow rate is calculated, the unit is protected against water flow losses and the pump is protected against cavitation (low pump entering pressure). Thermistors The water temperature sensors are installed in the entering and leaving side. Two optional water temperature sensors can be used for master/slave assembly control (in the case of leaving water control). 3.5 - The controls Water circulation pumps The controller can regulate each water heat exchanger pump and takes care of automatic changeover between pumps. Variable-flow pumps can control the heat exchanger temperature difference or the water pressure difference. Boiler If there is a unit fault in the heating mode this output authorises start-up and shutdown of a boiler. Immersion heaters The outputs of the AUX1 board permit control of the electric resistance heaters. They are used as a supplementary heating source in the heating mode.
3.4 - The sensors
3.6 - Connections at the user terminal block
Refrigerant pressure sensors Two types of electronic (high and low-pressure) sensors are used to measure the suction and discharge pressure in each circuit.
3.6.1 - General description The contacts below are available at the user terminal block on the NRCP2-BASE boards. Some contacts can only be used if the unit operates in remote operating type (Remote).
4
NRCP2-BASE control board
Optional PD-AUX board
J2A J12 J2B
J3
J3
J4
The following table summarises the connections at the user terminal block. Description
Connector/ channel
Contact 1: Start/stop
Terminal
Board
Remarks
J4/CH 8
32-33
NRCP2-BASE
Used with the remote operating mode (Remote).
J4/CH 10
73-74
NRCP2-BASE
Contact 2: Heating/cooling selection J4/CH 9 Contact 3: Demand limit selection 1 Customer safety loop input
J4/CH 11A
Contact 3 bis: Demand limit selection 2
J5/CH 14
Setpoint selection
J5/CH 13
Control, evaporator water pump
J2B/CH 18
Alarm relay output
J3/CH 24
CCN network connection
J12
Control, condenser water pump Unit operation relay output
J2B/CH 22
J3/CH 25
Triac output for boiler command
63-64
34-35
NRCP2-BASE
NRCP2-BASE NRCP2-BASE
Used with the remote operating mode (Remote), unit without NRCP2-SLAVE board.
NRCP2-BASE
-
NRCP2-BASE
-
NRCP2-BASE
RS-485 series connection - Pin 1: signal + - Pin 2: ground - Pin 3: signal -
NRCP2-BASE
30A-31A 37-38
J2B/CH 29
NRCP2-BASE
NRCP2-BASE
NRCP2-BASE
3.6.2 - Volt-free contact on/off/cooling/heating If the unit works in the remote operating mode (Remote) and the automatic heating/cooling changeover function is not selected and if the user configuration allows this (61WG or 30WG and Pro-Dialog interface selection) the operation of the on/off and the heating/cooling contacts is as follows: Without multiplexing On/off contact Heaing/cooling contact
Off Open -
On cooling Closed Open
Used with the remote operating mode (Remote).
On heating Closed Closed
Unit without NRCP2-SLAVE board. -
This output can be used to use a well pump
-
3.6.3 - Volt-free setpoint selection contact
Setpoint selection contact
Cooling csp 1 Open
csp 2 Closed
Heating hsp 1 Open
hsp 2 Closed
3.6.4 - Volt-free demand limit selection contact 100% Demand limit 1 Open Demand limit 2 Open
Limit 1 Closed Open
Limit 2 Open Closed
Limit 3 Closed Closed
With multiplexing On/off contact Heaing/cooling contact
Off Open Open
On cooling On heating Closed Closed Open Closed
On auto Open Closed
NOTE: The automatic changeover function (on auto) selects the cooling or heating mode based on the outside temperature (unit with outside temperature) - see chapter 5.2).
5
4. SETTING UP PRO-DIALOG+ CONTROL
Enter password
4.1 - General features
1_**
The interface includes different screens that are listed below: • Default screens with direct display of the main parameters, • Menu screens for navigation, • Data/configuration screens listing the parameters by type, • Operating mode selection screen, • Password entry screen, • Parameter modification screen.
The first digit is 1, the cursor is positioned on the second digit
(0 = basic access)
Enter password 11_** (0 = basic access)
NOTE: If the interface is not used for a long period, it will go black. The control is always active, the operating mode remains unchanged. The interface screen is re-animated, when the user presses a key. Pressing the key once illuminates the screen, pressing the key a second time leads to a screen that is related to the context and the key symbol.
Pressing the Enter key at a digit without value validates the overall selection of the password. The screen is refreshed by the menu list, and the items displayed depend on the level of the activated password.
4.2 - Default screen characteristics
The entry of an incorrect password keeps the password entry screen.
There are four default screens. Each screen shows: • The unit status, its screen number, • Three displayed parameters.
Password selection 0 (zero) can simply be made by pressing the Enter key twice in succession.
LOCAL OFF
1
On the left the unit status, on the right the screen number
Entering water temp
Description of the first parameter
term_ewt
Abbreviation and value with unit of measurement of the first parameter
17.2 °C
Leaving water temp
Description of the second parameter
term_lwt
Abbreviation and value with unit of measurement of the second parameter
17.2 °C
Control point CTRL_PNT
12 °C
(0 = basic access)
GENUNIT
PUMPSTAT
TEMP
RUNTIME
PRESSURE
MODES
SETPOINT
LOGOUT
General Parameters Menu
Description of the password entry screen Password value Description
Selection cursor to the left of the first column Menu list
INPUTS
Abbreviation and value with unit of measurement of the third parameter
The password is entered digit by digit. The cursor is shown at the current digit that flashes. The arrow keys modify the digit value. The digit modification is validated with the Enter key and the cursor is moved to the next digit.
6
Current path in the menu structure
OUTPUTS
4.3 - Password screens
0_**
\\MAINMENU
Description of the third parameter
Pressing the Up or Down key changes one default screen to another default screen. The screen number is updated.
Enter password
4.4 - Menu screen characteristics
Description of the menu framed by the selection cursor
Each menu item defines the access to categorised data. The Up and Down arrows position the cursor at the current item. The Enter key activates the display of the selected sub-menu. The item LOGOUT permits exiting from the menu screen and protects access by a user password. The “Previous” key permits exiting from the current screen without deactivating the password-protected access. 4.5 - Data screen or configurable parameter characteristics The data screens display information parameters such as temperatures or pressures. The configuration screens display unit control parameters such as the water temperature setpoints.
\\MAINMENU\TEMP
Current path in the menu structure
EWT
12.0°C
LWT
7.0°C
OAT
35.0°C
CHWSTEMP
-17.8°C
HTWSTEMP
-17.8°C
Leaving Water Temperature
List of items Cursor position
Description of the item framed by the selection cursor
The Up and Down arrow keys position the cursor on the current menu item. The Enter key activates the parameter modification (if possible). Any non-pertinent modification attempt is blocked by a refusal screen.
ATTENTION: If the user exits from the current data screen, the value is saved. A saving confirmation is displayed. The Enter key validates the parameter modification(s). The Return to the Previous Screen key cancels the current modification(s). \\MAINMENUSETPOINT
Current path in the menu structure
Save changes?
Confirmation that the modification is saved
4.6 - Parameter modification
4.7 - Operating mode screen
A configuration parameter can be modified by positioning the cursor and then pressing the Enter key.
The unit is in Local Off mode, pressing the on/off (0/1) key once activates the display of the operating mode screen.
\\MAINMENU\SETPOINT
Current path in the menu structure
cps1
12.0°C
List of items
cps2
12.0°C
Cursor position
ice_sp
12.0°C
hps1
50.0°C
hps2
50.0°C
Cooling Setpoint 2
The following screen allows modification of a parameter. Screen description csp 2 12.0
°C
Current value
_
°C
Cursor position
Cooling Setpoint 2
Local On
List of the machine operating modes
Local Schedule
Cursor
CCN
The Up and Down keys position the cursor on the selected operating mode. Four modes are immediately displayed on the screen. To access operating modes that are not visible, please use the Up and Down keys. When the operating mode has been selected, the new operating mode can be validated with the Enter key. Command accepted
Operating mode validation screen
Item description
The Up and Down arrow keys permit the selection of the first digit. Pressing the Up key successively scrolls up to the following symbols: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, ., -. The Down key follows the reverse order of the Up key in scrolling down the digit list above. Each digit is validated with the Enter key. The - sign is only accessible for the first selected character. Modify value
Description of the screen csp 2
12.0
°C
Current value
11.5_
°C
New value before validation
Cooling Setpoint 2
Description of the screen
Remote Description of the item framed by the selection cursor
Modify value
Select Machine Mode
When the unit is in an operating mode and the On/off key is pressed, the unit will stop. A confirmation screen protects the unit against inadvertent shutdowns.
PRESS ENTER TO CONFIRM STOP
Machine shutdown confirmation screen
Item description
The value is validated with the Enter key. At any time the return key cancels the current modification.
7
8
NAVIGATION
DEFAULT SCREENS
Password = "0"
ALL
USER
ACCESS
PASSWORD
ALMHIST1 ALMHIST1
SETPOINT* SETPOINT
Disconnection
LOGOUT LOGOUT
Configuration menu
CONFIG CONFIG
Alarms menu
ALARMS* ALARMS
Unit status
MODES MODES
Operating time
RUNTIME RUNTIME
Heating module status
HDC_STAT PUMPSTAT
Pump status
PUMPSTAT PUMPSTAT
Outputs
* Configurable from the GENCONF menu
Identification control
CTRL_ID DISPLAY
Date and time
DATETIME DATETIME
Broadcast
BRODCAST BRODCAST
User configuration
USERCONF USERCONF
Setpoint reset
RESETCFG RESETCFG
Heating module configuration
HDC_CONF HCCONFIG
configuration
HCCONFIG HCCONFIG Heating/cooling
Inputs
OUTPUTS OUTPUTS
Time schedule
HOLIDAY HOLIDAY Holidays
Alarm history
SCHEDULE SCHEDULE
Pump configuration
PUMPCONF PUMPCONF
General configuration
GENCONF GENCONF
INPUTS INPUTS
Setpoint
Pressures
CUR_ALRM CUR_ALRM
PRESSURE PRESSURE Current alarm
Reset of the alarms
ALARMRST ALARMRST
Temperatures
TEMP TEMP
General parameters
GENUNIT GENUNIT
(for local interface only)
LIST OF OPERATING MODES
SHUTDOWN CONFIRMATION SCREEN
Holidays 16
HOLIDY16S HOLIDY16S
… …
Holidays 2
HOLIDY02S HOLIDY02S
Holidays 1
HOLIDY01S
Schedule 3
OCC3P03S HOLIDY01S
Schedule 2
OCC2P02S OCC1P02S
Schedule 1
OCC1P01S OCC1P01S
4.8 - Menu tree structure
4.9 - Detailed menu description ATTENTION: Depending on the unit characteristics, certain menu items are not used. 4.9.1 - GENUNIT menu NAME ctrl_typ STATUS
UNIT -
DESCRIPTION Local = 0. CCN = 1. Remote = 2 Operating status
ALM min_left HEATCOOL LOCAL_HC HC_SEL
FORMAT 0/1/2 Running/Off/Stopping/ Delay Normal/Partial/Shutdown 0-15 Heat/Cool/Standby/Both 0/1/2 0/1/2
min -
LSP_SEL SP_SEL
0/1/2 0/1/2
-
SP_OCC CHIL_S_S CHIL_OCC CAP_T CAPA_T CAPB_T DEM_LIM SP CTRL_PNT EMSTOP
Yes/No Enable/Disable Yes/No nnn nnn nnn nnn ±nnn.n ±nnn.n Enable/Emstop
% % % % °C °C -
Alarm status Start-up delay Heating/cooling status Heating/cooling selection via the main interface Heating/cooling selection via the CCN network 0 = cooling, 1 = heating, 2 = auto Setpoint selection via the main interface Setpoint selection via the CCN network 0 = Auto 1 = Spt1 2 = Spt2 Occupied setpoint active Unit start/stop via the CCN network Unit time schedule via the CCN network Total unit capacity Capacity circuit A Capacity circuit B Demand limit value Current setpoint Control point CCN emergency stop
FORMAT ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n ±nnn.n
UNIT °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C °C
DESCRIPTION Evaporator entering water temperature Evaporator leaving water temperature Outside air temperature Common master/slave temperature, evaporator Common master/slave temperature, condenser Discharge gas temperature A Saturated condensing temperature A Saturated suction temperature A Suction gas temperature A Discharge gas temperature B Saturated condensing temperature B Saturated suction temperature B Suction gas temperature B Condenser entering water temperature Condenser leaving water temperature Drycooler leaving water temperature
UNIT kPa kPa kPa kPa
DESCRIPTION Discharge pressure A Suction pressure A Discharge pressure B Suction pressure B
VALUE 12.0 12.0 12.0 50.0 50.0 50.0 0.60 24.0 18.0 100 100 100 38
UNIT °C °C °C °C °C °C ^C °C °C % % % °C
4.9.2 - TEMP menu NAME CL_EWT CL_LWT OAT CHWSTEMP HTWSTEMP DGT A SCT_A SST_A SUCT_A DGT_B SCT_B SST_B SUCT_B COND_EWT COND_LWT DRY_LWT
4.9.3 - PRESSURE menu NAME DP_A SP_A DP_B SP_B
FORMAT ±nnn.n ±nnn.n ±nnn.n ±nnn.n
4.9.4 - SETPOINT menu NAME csp1 csp2 ice_sp hsp1 hsp2 hsp3 hramp_sp cauto_sp hauto_sp lim_sp1 lim_sp2 lim_sp3 cond_sp
FORMAT - 29.7 to 20 - 29.7 to 20 - 29.7 to 20 20 to 50 20 to 50 20 to 55 0.1 to 1.1 3.9 to 50 0 to 46.1 0 to 100 0 to 100 0 to 100 0 to 60
DESCRIPTION Cooling setpoint 1 Cooling setpoint 2 Ice storage cooling setpoint Heating setpoint 1 Heating setpoint 2 Heating setpoint 3 Ramp loading Cooling changeover setpoint Heating changeover setpoint Limit setpoint 1 Limit setpoint 2 Limit setpoint 3 Condensing setpoint, condenser
* 50, if the unit includes a variable-speed fan
9
4.9.5 - INPUTS menu NAME ONOFF_SW HC_SW on_ctrl SETP_SW1 SETP_SW2 LIM_SW1 LIM_SW2 FLOW_SW DIFF_SW
FORMAT Open/Close Open/Close Off, On Cool, On Heat, On Auto Open/Close Open/Close Open/Close Open/Close Open/Close Open/Close
UNIT -
DESCRIPTION Remote start/stop contact Remote heating/cooling contact Current control Remote setpoint contact 1 Remote setpoint contact 2 Remote demand limit contact 1 Remote demand limit contact 2 Water flow rate/customer safety loop contact Water flow rate contact 2 (30WG)
4.9.6 - OUTPUTS menu NAME CP_A1 CP_A2 CP_A3 FAN_A exv_a HD_POS_A RV_A LLS_A CP_B1 CP_B2 FAN_B exv_b HD_POS_B RV_B LLS_B FAN_DRY VFAN_DRY 3wv EHS_STEP ALARM RUNNING
FORMAT On/Off On/Off On/Off 0-8 0-100 0-100 On/Off On/Off On/Off On/Off 0-8 0-100 0-100 On/Off On/Off 0-8 0-100 0-100 0-4 On/Off On/Off
UNIT % % % % % % -
DESCRIPTION Compressor output A1 Compressor output A2 Compressor output A3 Fan outputs, condenser A EXV position circuit A Position variable speed controller fan A Four-way refrigerant valve Liquid line solenoid valve A Compressor output B1 Compressor output B2 Fan outputs, condenser B EXV position circuit B Position variable fan speed controller B Four-way refrigerant valve Liquid line solenoid valve B Drycooler fan outputs Position drycooler variable speed fan Three-way valve position Electric heater stages Alarm relay Unit on relay
4.9.7 - PUMPSTAT menu NAME CL_PUMP CL_WPIN CL_WPOUT CL_WPCAL
FORMAT On/Off ±nnn.n ±nnn.n Yes/No
UNIT kPa kPa -
CL_OFFST CL_FILTR CL_WPMIN CL_WFLOW CL_wdtsp CL_wdpsp CL_DvPos CL_drvpwr CL_drvpI CL_drvvs CL_dvTyp CD_PUMP CD_WPIN CD_WPOUT CD_WPCAL
±nnn.n nnn.n nnn.n ±nnn.n nn.n nn.n Nnn ±nnn.n ±nnn.n xxxxxxxx Xxxxxxxx On/Off ±nnn.n ±nnn.n Yes/No
kPa kPa kPa G/s ^C kPa % kW A kPa kPa -
CD_OFFST CD_FILTR CD_WPMIN CD_WFLOW CD_wdtspt CD_wdpspt CD_DvPos CD_drvpwr CD_drvpl CD_drvvs CD_dvTyp
±nnn.n nnn.n nnn.n ±nnn.n nn.n nn.n Nnn +nnn.n +nnn.n xxxxxxxx Xxxxxxxx
kPa kPa kPa g/s ^C kPa % kW A -
10
DESCRIPTION Evaporator pump control Evaporator entering water pressure sensor Evaporator leaving water pressure sensor Evaporator water pressure sensor calibration?.Following a water pressure sensor error, CL_OFFST is deconfigured (-99 kPa) to inform of the need to calibrate the water loop. This calibration must be made while there is no water flow in the machine Water pressure sensor calibration value Evaporator filter pressure drop Minimum evaporator water pressure Evaporator water flow rate Evaporator temperature difference setpoint Evaporator pressure difference setpoint Evaporator pump speed setpoint Evaporator pump power Evaporator pump current Evaporator pump speed variable speed controller version Evaporator pump variable speed controller type Control condenser pump Condenser entering water pressure sensor Condenser leaving water pressure sensor Condenser water pressure sensor calibration? Following a water pressure sensor error, CD_OFFST is deconfigured (-99 kPa) to inform of the need to calibrate the water loop. This calibration must be made while there is no water flow in the machine Condenser water pressure sensor calibration value Condenser filter pressure drop Minimum condenser water pressure Condenser water flow rate Condenser temperature difference setpoint Condenser pressure difference setpoint Condenser pump speed setpoint Condenser pump power Condenser pump current Condenser pump speed variable speed controller version Condenser pump variable speed controller type
4.9.8 – HDC_STAT menu NAME dhw_mode dhw_dem dhw_time shc_time sum_mode ctrl_pnt oat DHW_REQ DHW_SW SUMM_SW add_pump dhw_vlv ehs
FORMAT n No/Yes nnn nnn No/Yes +-nnn.n +-nnn.n Open/Close Open/Close Open/Close Off/On Off/On n
UNIT mn mn °C °C -
DESCRIPTION Mode (0 = heating, 1 = DHW, 2 = valve moving) DHW demand DHW mode operating time Heating mode operating time Summer mode Current setpoint Outside air temperature DHW demand volt-free contact (from the tank) DHW priority volt-free contact Summer mode volt-free contact Additional pump output DHW three-way valve output Electric heater stages
UNIT hours hours hours hours hours hours hours hours hours hours hours
DESCRIPTION Unit operating hours Unit operating hours in cooling mode Unit operating hours in heating mode Number of start-ups, unit Operating hours compressor A1 Number of start-ups compressor A1 Operating hours compressor A2 Number of start-ups compressor A2 Operating hours compressor A3 Number of start-ups compressor A3 Operating hours compressor B1 Number of start-ups compressor B1 Operating hours compressor B2 Number of start-ups compressor B2 Operating hours evaporator pump Operating hours condenser pump Operating hours open-loop pump Operating hours electric heater stages Operating hours HDC module pump
UNIT -
DESCRIPTION Demand limit active Ramp loading active Low-noise level night mode Aquasmart active Master/slave active Changeover active Electric heater stages active Lock heating mode and entering water too cold Boiler active Low suction temperature circuit A Low suction temperature circuit B High discharge gas temperature circuit A High discharge gas temperature circuit B High pressure circuit A High pressure circuit B Low superheat circuit A Low superheat circuit B Domestic hot water mode Summer mode
4.9.9 - RUNTIME menu NAME hr_mach chr_mach hhr_mach st_mach HR_CP_A1 st_cp_a1 HR_CP_A2 st_cp_a2 HR_CP_A3 st_cp_a3 HR_CP_B1 st_cp_b1 HR_CP_B2 st_cp_b2 hr_clpmp hr_cdpmp Hr_olpmp hr_ehs hr_hdpmp
FORMAT nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn
4.9.10 - MODES menu NAME m_limit m_ramp m_night m_SM m_leadla m_auto m_heater m_lo_ewt m_boiler m_sst_a m_sst_b m_dgt_a m_dgt_b m_hp_a m_hp_b m_sh_a m_sh_b m_dhw m_summer
FORMAT Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No Yes/No
4.9.11 - ALARMS menu NAME ALARMRST CUR_ALRM ALMHIST1
DESCRIPTION Alarm reset Current alarms Alarm history
11
4.9.12 - CONFIG menu NAME GEN_CONF PUMPCONF HC_CONFIG HDC_CONF RESETCFG USERCONFIG SCHEDULE HOLIDAY BRODCAST DATETIME DISPLAY CTRL_ID
DESCRIPTION General configuration menu Water pump configuration menu Heating/cooling configuration menu Heating module configuration menu Reset configuration menu User configuration menu Time schedule Holiday calendar Broadcast menu Date and time menu Display configuration menu Identification control
4.9.13 - ALARMRST menu NAME RESET_AL ALM alarm_1c alarm_2c alarm_3c alarm_4c alarm_5c alarm_1 alarm_2 alarm_3 alarm_4 alarm_5
FORMAT Normal Normal nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn nnnnn
UNIT -
4.9.14 - CUR_ALRM menu This menu lists up to ten a active alarms. For each alarm the display shows the time and date the alarm was generated as well as the alarm description. Each screen shows one alarm.
DESCRIPTION Alarm reset Alarm status Current alarm 1 Current alarm 2 Current alarm 3 Current alarm 4 Current alarm 5 Current JBus alarm 1 Current JBus alarm 2 Current JBus alarm 3 Current JBus alarm 4 Current JBus alarm 5
4.9.15 - ALMHIST1 menu This menu lists up to twenty alarms that have occurred at the unit. For each alarm the display shows the time and date the alarm was generated as well as the alarm description. Each screen shows one alarm.
…\ALARMS\CUR_ALM
…\ALARMS\ALMHIST1
HH:MM DD-MM-YY: alarm text
HH:MM DD-MM-YY: alarm text
Alarm #1
Alarm #1
4.9.16 - SCHEDULE menu NAME OCC1P01S OCC1P02S OCC3P03S
DESCRIPTION Unit on/off time schedule Unit setpoint selection time schedule Domestic hot water time schedule
4.9.17 - HOLIDAY menu NAME HOLDY_01 HOLDY_02 HOLDY_03 HOLDY_04 HOLDY_05 HOLDY_06 HOLDY_07 HOLDY_08 HOLDY_09 HOLDY_10 HOLDY_11 HOLDY_12 HOLDY_13 HOLDY_14 HOLDY_15 HOLDY_16
12
DESCRIPTION Holiday period 1 Holiday period 2 Holiday period 3 Holiday period 4 Holiday period 5 Holiday period 6 Holiday period 7 Holiday period 8 Holiday period 9 Holiday period 10 Holiday period 11 Holiday period 12 Holiday period 13 Holiday period 14 Holiday period 15 Holiday period 16
4.9.18 - BRODCAST menu NAME ccnbroad
FORMAT 0/1/2
DEFAULT 2
UNIT -
oatbusnm
0 to 239
0
-
oatlocad dayl_sel Summer time startmon startdow startwom Winter time stopmon stoptdow stopwom
0 to 239 Disable/Enable
0 Disable
-
DESCRIPTION Activates the broadcast 0 = deactivated, 1= broadast during holidays at the network, 2 = broadcast during holidays, machine only Broadcast of the outside temperature Bus number of the machine with the outside temperature Element number of the machine with the outside temperature Activation summer time, winter time
1 to 12 1 to 7 1 to 5
3 7 5
-
Month Day of the week (1 = Monday) Week of the month
1 to 12 1 to 7 1 to 5
10 7 5
-
Month Day of the week (1 = Monday) Week of the month
DESCRIPTION Circuit loading sequence 0 = auto, 1 = A first, 2 = B first Loading sequence by circuit Ramp loading sequence Start-up delay Capacity limitation in night mode Night mode start hour Night mode stop hour Basic menu configuration 0 = total access 1 = access to the alarm menu by password 2 = access to the setpoint menu by password 3 = combination of 1 and 2 Synoptic diagram displayed
4.9.19 - GENCONF menu NAME lead_cir
FORMAT 0/1/2
DEFAULT 0
UNIT -
seq_typ ramp_sel off_on_d nh_limit nh_start nh_end bas_menu
No/Yes No/Yes 1 to 15 0 to 100 00:00 to 24:00 00:00 to 24:00 0 to 3
No No 1 100 00:00 00:00 0
min % -
synoptic
No/Yes
No
-
DEFAULT No No No Yes No No No Yes No
UNIT -
4.9.20 - PUMPCONF menu NAME clpmpseq clpmpper clpmpsby clpmploc cdpmpseq cdpmpper cdpmpsby cdpmploc ol_pump
FORMAT No/Yes No/Yes No/Yes No/Yes No/Yes No/Yes No/Yes No/Yes No/Yes
DESCRIPTION Evaporator pump selection Evaporator pump seizure protection Pump shutdown when the unit is in standby Flow rate verification when the pump has shut down Condenser pump selection Condenser pump seizure protection Pump shutdown when the unit is in standby Flow rate verification when the pump has shut down Open-loop pump control selection
4.9.21 - HCCONFIG menu NAME auto_sel cr_sel hr_sel
FORMAT No/Yes 0 to 2 0 to 2
DEFAULT No 0 0
UNIT -
heat_th boil_sel boil_th ehs_sel ehs_th both_sel ehs_back ehs_pull ehs_defr
-20 to 0 No/Yes -15 to 15 0 to 4 -5 to 21.2 No/Yes No/Yes 0 to 60 No/Yes
-15 No -10 0 5 No No 0 No
°C °C °C minutes -
DESCRIPTION Automatic changeover selection Cooling reset selection Heating reset selection 1 = outside temp., 0 = none, 2 = delta T Outside temperature threshold cooling mode Boiler control selection Outside temperature threshold for the boiler Selection, number of electric heater stages Outside temperature threshold for electric heater stages Heating or cooling command selection for HSM 1 backup electric heater stage Delay before start-up of the first electric heater stage Quick electric heat stages for defrost
DEFAULT Yes 20.0
UNIT °C
DESCRIPTION Additional pump anti-stick function Outside air temperature threshold for the mode
5 5 30 180 30 180
hours hours minutes minutes minutes minutes
Time before changeover to summer mode Time before changeover to winter mode Minimum duration in heating mode Maximum duration in heating mode Minimum duration in DHW mode Maximum duration in DHW mode
4.9.22 - HDC_CONF menu NAME FORMAT adpmpper Yes/No summ_oat 15.0 to 30.0 Summer summ_on 0 to 12 summ_off 0 to 12 shc_min 0 to 720 shc_max -1 to 720 * dhw_min 0 to 720 dhw_max -1 to 720 * * -1 means that the maximum value is ignored
13
4.9.23 - RESETCFG menu NAME COOLING RESET oatcr_no oatcr_fu dt_cr_no dt_cr_fu cr_deg HEATING RESET oathr_no oathr_fu dt_hr_no dt_hr_fu hr_deg
FORMAT
DEFAULT
UNIT
DESCRIPTION
-10 to 51.7 -10 to 51.7 0 to 13.9 0 to 13.9 -16.7 to 16.7
-10 -10 0 0 0
°C °C ^C ^C ^C
Outside temperature for no reset Outside temperature for maximum reset Delta T for no reset Delta T for maximum reset Cooling reset value
-10 to 51.7 -10 to 51.7 0 to 13.9 0 to 13.9 -16.7 to 16.7
-10 -10 0 0 0
°C °C ^C ^C ^C
Outside temperature for no reset Outside temperature for maximum reset Delta T for no reset Delta T for maximum reset Heating reset value
DESCRIPTION Language selection English = 0, Spanish = 1, French = 2, Portuguese = 3, Italian = 4, Translation = 5 User password
4.9.24 - USERCONF menu NAME language
FORMAT 0 to 4
DEFAULT 0
UNIT -
use_pass
1 to 9999
11
-
DEFAULT
UNIT hours minutes
No No
-
DEFAULT 1 0 9600 PRO-DIALOG + 30WG CSA-SR-20H450NN -
UNIT -
4.9.25 - DATETIME menu NAME hour minutes dow tom_hol tod_hol dlig_off dlig_on d_of_m month year
FORMAT 0 to 24 0 to 59 1 to 7 No/Yes No/Yes No/Yes No/Yes 1 to 31 1 to 12 0 to 99
DESCRIPTION Hour Minutes Day of the week Holiday tomorrow? Holiday today Winter time changeover active? Summer time changeover active? Day of the month Month Year
4.9.26 - Menu CTRL_ID NAME elemt_nb bus_nb baudrate
FORMAT 1 to 239 0 to 239 9600 to 38400
4.9.27 - OCCx P0xS menu The control provides three timer programs: schedule 1, schedule 2 and schedule 3, that can be activated. The first timer program (schedule 1) provides a means to automatically switch the unit from an occupied mode to an unoccupied mode: the unit is started during occupied periods. The second timer program (schedule 2) provides a means to automatically switch the active setpoint from an occupied setpoint to an unoccupied setpoint: cooling setpoint 1 is used during occupied periods, cooling or heating setpoint 2 during unoccupied periods. The third timer program (schedule 3) allows the unit to switch to the domestic hot water production mode. The DHW mode is allowed during occupied periods. Each schedule consists of eight time periods set by the operator. These time periods can be flagged to be in effect or not in effect on each day of the week plus a holiday period. The day begins at 00.00 hours and ends at 23.59 hours. Program is in unoccupied mode unless a schedule time period is in effect. If two periods overlap and are both active on the same day, the occupied mode takes priority over the unoccupied period. 14
DESCRIPTION Element number Bus number Communication speed Description Software version Serial number
Each of the eight periods can be displayed and changed with the aid of a sub-sub-menu. The table on page 15 shows how to access the period configuration. Method is the same for the time schedule 1 or the time schedule 2.
Time schedule type: Time
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
MON TUE WES THU
FRI
SAT SUN HOL
P1 P1 P1
P2
P2
P3
P4
P4
P5
P2
P2
P3
P4
P4
P5
P2 P2 P2 P2 P2 P2 P2 P2 P2
P2 P2 P2 P2 P2 P2 P2 P2 P2
P3 P3 P3 P3 P3 P3 P3 P3 P3
P4 P4 P4 P4 P4 P4 P4 P4
P4 P4 P4 P4
P5
MON:
Monday
TUE:
Tuesday
WED:
Wednesday
THU:
Thursday
FRI:
Friday
SAT:
Saturday
SUN:
Sunday
HOL:
Holiday
Starts at Stops at 0h00, 3h00, 7h00, 18h00, 7h00, 21h00, 7h00, 17h00, 7h00, 12h00, 20h00, 21h00, Not used in this example Not used in this example
Active on Monday Monday + Tuesday Wednesday Thursday + Friday Saturday Holidays
P5 P5
P4 P4 P4 P4
P3 P3 P3
P6
Occupied Unoccupied
NAME OVR_EXT DOW1
FORMAT 0-4 0/1
DEFAULT 0 11111111
UNIT hours -
OCCTOD1 UNOCTOD1 DOW2
0:00-24:00 0:00-24:00 0/1
00:00 24:00:00 0
-
OCCTOD2 UNOCTOD2 DOW3
0:00-24:00 0:00-24:00 0/1
00:00 00:00 0
-
OCCTOD3 UNOCTOD3 DOW4
0:00-24:00 0:00-24:00 0/1
00:00 00:00 0
-
OCCTOD4 UNOCTOD4 DOW5
0:00-24:00 0:00-24:00 0/1
00:00 00:00 0
-
OCCTOD5 UNOCTOD5 DOW6
0:00-24:00 0:00-24:00 0/1
00:00 00:00 0
-
OCCTOD6 UNOCTOD6 DOW7
0:00-24:00 0:00-24:00 0/1
00:00 00:00 0
-
OCCTOD7 UNOCTOD7 DOW8
0:00-24:00 0:00-24:00 0/1
00:00 00:00 0
-
OCCTOD8 UNOCTOD8
0:00-24:00 0:00-24:00
00:00 00:00
-
4.9.28 - HOLIDY0XS menu This function is used to define 16 public holiday periods. Each period is defined with the aid of three parameters: the month, starting day and duration of the public holiday period. During these public holidays the controller will be in occupied or unoccupied mode, depending on the programmed periods validated for public holidays. NAME HOL_MON HOL_DAY HOL_LEN
P1: period 1, P2: period 2, P3: period 3, P4: period 4, P5: period 5, P6: period 6, P7: period 7, P8: period 8,
FORMAT 0-12 0-31 0-99
DEFAULT 0 0 0
DESCRIPTION Occupied schedule override Period 1 day of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 2 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 3 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 4 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 5 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 6 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 7 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until Period 8 days of the week MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday Occupied from Occupied until
Each of these public holiday periods can be displayed and changed with the aid of a sub-menu. ATTENTION: The broadcast function must be activated to utilise the holiday schedule, even if the unit is running in stand-alone mode (not connected to CCN). UNIT -
DESCRIPTION Holiday month Holiday day Holiday duration
15
5 - PRO-DIALOG+ CONTROL OPERATION
• •
5.1 - Start/stop control The table below summarises the unit control type and stop or go status with regard to the following parameters. • Operating type: this is selected using the start/stop button on the front of the user interface. LOFF: local off, L-C: local on, L-SC: local schedule, REM: remote, CCN: network, MAST: Master • Remote start/stop contacts: these contacts are used when the unit is in remote operating type (Remote). See sections 3.6.2 and 3.6.3. • CHIL_S_S: this network command relates to the unit start/stop when the unit is in network mode (CCN). ACTIVE OPERATING TYPE
• •
• •
Command set to Stop: the unit is halted. Command set to Start: the unit runs in accordance with schedule 1. Start/Stop schedule: occupied or unoccupied status of the unit as determined by the chiller start/stop program (Schedule 1). Master control type. This parameter is used when the unit is the master unit in a two chiller lead/lag arrangement. The master control type determines whether the unit is to be controlled locally, remotely or through CCN (this parameter is a Service configuration). CCN emergency shutdown: if this CCN command is activated, it shuts the unit down whatever the active operating type. General alarm: the unit is totally stopped due to failure.
STATUS OF PARAMETERS
LOFF
L-ON
L-SC
rEM
CCN
MASt
CHIL_S_S
Active -
Active -
Active Active -
Active Active Active Active Active -
Active Active Active -
Active Active Active Active Active Active Active Active Active Active
Disable Disable Enable Enable
REMOTE START/STOP CONTACT Off Off On cooling On heating On auto On cooling On heating On auto -
MASTER CONTROL TYPE Local Remote Remote CCN CCN Local Remote Remote Remote CCN
START/STOP SCHEDULE MODE Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Unoccupied Occupied Occupied Occupied Occupied Occupied Occupied Occupied Occupied Occupied Occupied
CCN EMERGENCY SHUTDOWN Enable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable Disable
GENERAL ALARM Yes No No No No No No No No No No No
CONTROL UNIT TYPE MODE
Local Local Remote Remote CCN CCN Local Remote Remote CCN CCN Local Local Remote Remote Remote CCN Local Remote Remote Remote CCN
Off Off Off Off Off Off Off Off Off Off Off Off Off On On On On On On On On On On On
5.2 - Heating/cooling/standby operation 5.2.1 - General The heating/cooling/standby selection applies to all units. It can be done manually (or automatically on a unit with outside air temperature sensor). In automatic mode the outdoor temperature determines the heating/cooling/standby changeover based on the two threshold values configured by the user (see RESETCFG menu). If the unit is in standby it does not cool or heat, and no compressor can be activated. The diagram below summarises the operating principle in automatic mode.
16
HEATING
*
STANDBY
Heating threshold*
COOLING
Cooling threshold
Outdoor temperature
This threshold does not apply to cooling only units that do not control a boiler.
5.2.2 - Heating/cooling/auto selection The table below summarises the unit heating/cooling operation, based on the following parameters: • Control type: indicates whether the unit operates in local, remote or CCN mode. See section 5.1. • Unit on/off status: indicates whether the unit is shut down (not authorised to start) or in operation (or authorised to start). • Heating/cooling/auto selection in local mode: operating mode selected via the user interface. See GENUNIT menu. PARAMETER STATUS ON/OFF STATUS CONTROL TYPE Off On On On On On On On On On On On On On On On *
HEATING/COOLING REMOTE HEATING/ SELECTION IN COOLING LOCAL MODE CONTACTS Local Cooling Local Heating Local Auto Local Auto Local Auto Remote Cooling mode Remote Heating mode Remote Auto mode Remote Auto mode Remote Auto mode CCN CCN CCN CCN CCN Does not apply to cooling only units that do not control a boiler.
• • •
Remote heating/cooling contacts: these contacts are only active if the unit is under remote control. HC_SEL: this network command permits heating/ cooling/auto control, if the unit is in CCN operating mode. Outside temperature: determines the operation, if the unit is in automatic heating/cooling/standby changeover mode.
HC_SEL
OUTDOOR TEMPERATURE
OPERATING MODE
Cooling Heating Auto Auto Auto
> Cooling threshold < Heating threshold Between cooling and heating thresholds > Cooling threshold < Heating threshold Between cooling and heating thresholds > Cooling threshold < Heating threshold Between cooling and heating thresholds
Cooling Cooling Heating Cooling Heating* Standby Cooling Heating Cooling Heating* Standby Cooling Heating Cooling Heating* Standby
5.3 - Heat exchanger water pump control
5.4 - Control interlock contact
The unit can control one water pump per heat exchanger. The pump is turned on when this option is configured (see PUMPCONFIG) and when the unit is in one of the on modes described above or in delay mode. Since the minimum value for the delay at start-up is 1 minute (configurable between 1 and 15 minutes), the pump will run for at least one minute before the first compressor starts.
This contact checks the status of a loop (water flow switch and customer safety loop, see chapter 3.6). It prevents the unit from starting if it is open when the delay at start-up has expired. This open contact leads to an alarm shut-down, if the unit is running.
The pump is kept running for 2 minutes after the unit goes to stop mode. The pump keeps working when the unit switches from heating to cooling mode or vice-versa. It is turned off if the unit is shut down due to an alarm unless the fault is a frost protection error. The pump can be started in particular operating conditions when frost protection of the heat exchanger is active (see chapter “Control point”). See chapter “Master/slave assembly” for the particular heat exchanger pump control for the slave unit (master/slave assembly).
The control point represents the water temperature that the unit must produce. The heat exchanger entering water temperature is controlled by default, but the heat exchanger leaving water temperature can also be controlled (requires a Service configuration modification).
If the pump with variable flow option has been selected (factory-installed option), it is possible to control the water flow in three ways (service parameters): • adjusted fixed flow rate, • constant temperature difference, • constant pressure difference. In this way it is possible to adjust the water loops and to optimise pump operation.
5.5 - Control point
Control point = active setpoint + reset 5.5.1 - Active setpoint Three setpoints can be selected as active in cooling mode and two in heating mode. Usually, the second setpoint is used for unoccupied periods. Depending on the current operating type, the active setpoint can be selected: • by choosing the item in the GENUNIT menu, • via the user’s volt-free contacts, • via network commands • via the setpoint timer program (schedule 2).
The control provides a means to automatically start the pump each day at 14.00 hours for 2 seconds when the unit is off (pump anti-stick function). Starting the pump periodically for few seconds increases the life-time of the pump bearings and the tightness of the pump seal. 17
LOCAL OPERATING MODE
PARAMETER STATUS Heating/cooling Local setpoint operating mode selection Cooling sp 1 Cooling sp 2 Cooling Ice_sp
Time schedule 2 status -
Cooling Cooling Heating Heating Heating Heating Heating
occupied unoccupied occupied unoccupied
auto auto sp1 sp 2 sp 3 auto auto
Active setpoint Cooling setpoint 1 Cooling setpoint 2 Ice storage cooling setpoint Cooling setpoint 1 Cooling setpoint 2 Heating setpoint 1 Heating setpoint 2 Heating setpoint 3 Heating setpoint 1 Heating setpoint 2
REMOTE OPERATING MODE
PARAMETER STATUS Heating/cooling operating mode Cooling Cooling Heating Heating
Setpoint selection contact sp 1 (open) sp 2 (closed) sp 1 (open) sp 2 (closed)
Active setpoint Cooling setpoint 1 Cooling setpoint 2 Heating setpoint 1 Heating setpoint 2
5.5.2 - Reset Reset means that the active setpoint is modified so that the machine capacity required is adjusted to be as close as possible to the demand. This modification is in general a reaction to a drop in the load. For the Pro-Dialog control system, the source of the reset can be configured in the HCCONFIG configuration: it can be provided either by the outdoor temperature (that gives a measure of the load trends for the building) or by the return water temperature (heat exchanger delta T, gives an average building load). In response to a drop in the outdoor temperature or to a drop in delta T, the cooling setpoint is normally reset upwards in order to optimise unit performance: In both cases the reset parameters, i.e. slope, source and maximum value, are configurable in the RESETCFG menu (see section 4.3.8). Reset is a linear function based on three parameters. • A reference at which reset is zero (outdoor temperature or delta T - no reset value). • A reference at which reset is maximum (outdoor temperature or delta T - full reset value). • The maximum reset value.
18
% Building load
Reset example in cooling mode based on the outside temperature
Reset value
The following tables summarise the possible selections depending on the control types (local, remote or network) and the following parameters: • Setpoint select in local control: item LSP_SEL in the GENUNIT menu permits selection of the active setpoint, if the unit is in local operating type. • Heating/cooling operating mode. • Setpoint selection contacts: setpoint selection contact status. • Schedule 2 status: schedule for setpoint selection.
Outdoor temperature (OAT) Heat exchanger delta T Legend A Maximum reset value B OAT or delta T for no reset C OAT or delta T for full reset D Building Load
5.6 - Capacity control This function adjusts the number of active compressors to keep the heat exchanger water temperature at its setpoint. The precision with which this is achieved depends on the capacity of the water loop, the flow rate, the load, and the number of stages available on the unit. The control system continuously takes account of the temperature error with respect to the setpoint, as well as the rate of change in this error and the difference between entering and leaving water temperatures, in order to determine the optimum moment at which to add or withdraw a capacity stage. If the same compressor undergoes too many starts (per hour) or runs below one minute each time it is started this automatically brings about reduction of compressor starts, which makes leaving water temperature control less precise. The high pressure, low pressure or defrost unloading functions can also affect temperature control accuracy. Compressors are started and stopped in a sequence designed to equalise the number of start-ups (value weighted by their operating time). 5.7 - Demand limit The demand limit is used to restrict the unit power consumption. The Pro-Dialog control system allows limitation of the unit capacity, using user-controlled volt-free contacts. The unit capacity can never exceed the limit setpoint activated by these contacts. The limit setpoints can be modified in the SETPOINT menu. 5.8 - Night mode The night period is defined (see GENUNIT configuration) by a start time and an end time that are the same for each day of the week. During the night period the unit capacity may be limited.
5.9 - Control of a boiler NOTE: The control of the electric heating stages or of a boiler is not authorised for slave units. The unit can control the start-up of a boiler, if it is in heating mode. When the boiler is operating, the unit water pump is stopped. The unit and a boiler cannot operate together. In this case the boiler output is activated in the following conditions: • The unit is in heating mode, but a fault prevents the use of the heat pump capacity. • The unit is in heating mode, but works at a very low outdoor temperature, making the heat pump capacity insufficient. It is possible to adjust the boiler start-up based on the outside temperature (HCCONFIG menu).
One of the functions of the master unit (depending on its configuration) may be the designation, whether the master or slave is to be the lead machine or the follower. The roles of lead machine and follower will be reversed when the difference in running hours between the two units exceeds a configurable value, ensuring that the running times of the two units are automatically equalised. The changeover between lead machine and follower may take place when the assembly is started up, or even whilst running. The running time balancing function is not active if it has not been configured: in this case the lead machine is always the master unit.
Two Pro-Dialog+ units can be linked to produce a master/ slave assembly. The two machines are interconnected over the CCN bus. All parameters required for the master/slave function must be configured through the Service configuration menu.
The lead machine will always be started first. When the lead machine is at its full available capacity, start-up delay (configurable) is initialised on the follower. When this delay has expired, and if the error on the control point is greater than 1.7°C, the follower unit is authorised to start and the pump is activated. The follower will automatically use the master unit active setpoint. The lead machine will be held at its full available capacity for as long as the active capacity on the follower is not zero. When the follower unit receives a command to stop, its evaporator water pump is turned off with 20 seconds delay.
Master/slave operation requires the connection of a temperature probe at the common manifold on each machine, if the heat exchanger leaving water temperature is controlled. It is not required, if the entering water temperature is controlled.
In the event of a communication fault between the two units, each shall return to an autonomous operating mode until the fault is cleared. If the master unit is halted due to an alarm, the slave unit is authorised to start without prior conditions.
The master/slave assembly can operate with constant or variable flow. In the case of variable flow each machine must control its own water pump and automatically shut down the pump, if the cooling capacity is zero.
ATTENTION: For heat pumps operating in master/slave mode and using an NRCP2 board or equipped with electric heater stages control must be on the entering water temperature.
For constant flow operation the pumps for each unit are continuously operating, if the system is operating. The master unit can control a common pump that will be activated, when the system is started. In this case the slave unit pump is not used.
5.11 - Heating module (HDC) control
5.10 - Master/slave assembly
All control commands to the master/slave assembly (start/ stop, setpoint, heating/cooling operation, load shedding, etc.) are handled by the unit which is configured as the master, and must therefore only be applied to the master unit. They will be transmitted automatically to the slave unit. The master unit can be controlled locally, remotely or by CCN com-mands. Therefore to start up the assembly, simply validate the Master operating type (Master) on the master unit. If the Master has been configured for remote control then use the remote volt-free contacts for unit start/stop. The slave unit must stay in CCN operating type continuously. To stop the master/slave assembly, select Local Off on the master unit or use the remote volt-free contacts if the unit has been configured for remote control.
61WG units are specially designed to optimise the operation of heating installations that require hot-water production for traditional heating and domestic hot water (DHW) requirements. In this case an AUX board is included in the unit control box. The Pro-Dialog+ control of the 61WG includes algorithms that permit constant and automatic optimisation: • control of a three-way directional on/off valve based on the heating or domestic hot water requirements • control of the electric heater stages can complement the heating loop • hot water setpoint reset (heating application) based on the outside air temperature • priority control between heating and domestic hot water applications. 5.11.1 – Sensor An optional outside air temperatrure sensor can be used to reset the setpoint or determine the summer/winter mode.
19
5.11.2 – Controls The heating module controls the following elements: • A three-way valve to switch over to domestic hot water production • An additional water pump in the heating circuit • Up to four electric heating stages (for supplementary safety stage heating) 5.11.3 – User connection terminals Three volt-free contacts are available at a user connection terminal board: • A contact for DHW demand from the tank • A volt-free contact for DHW priority • A volt-free contact for the summer mode 5.11.4 – Control of additional electric heater stages The heat pump units can control up to four electric heater stages as supplementary heating. Electric heater stages are activated to supplement the heating capacity if the following conditions are satisfied: • The unit uses 100% of its available heating capacity or the unit is limited in its operation by a protection mode (e.g. low suction temperature protection) and in all cases cannot satisfy the heating demand. • The outside temperature is below a configurable threshold (see HCCONFIG menu) • Unit demand limitation is not active. If required the user can configure the last electric heater stage available as a safety stage. That safety stage is only activated in addition to the other stages, if there is a unit fault that prevents the use of the heating capacity. The other electric heater stages continue to operate a described above. The electric heater stages only operate in the heating mode, but not during domestic hot water production. 5.11.5 – Heating or domestic hot water A three-way valve permits switching the heating capacity to a heating circuit (fan coil units, radiators or floor heating), or to a domestic hot water tank. The unit requests changeover to the domestic hot water mode if all the following conditions have been met: • The volt-free tank request contact is closed AND • Time schedule 3 is in an occupied period OR the volt-free priority contact is closed. Based on the operating mode the water setpoint is adjusted: • In heating mode, setpoints hsp1 and hsp2 are used. They can be modified by user reset or based on the outside temperature. • In domestic hot water production mode setpoint hsp3 is used. No setpoint reset is used. The unit requests changeover to the heating mode, if at least one of the following conditions applies: • The volt-free tank request contact is open OR • The maximum operating duration in the DHW mode has finished OR • Time schedule 3 is in an unoccupied period.
20
If a mode change is requested while a compressor is operating, it is stopped before the three-way valve changes to the new mode, and then the unit is re-started. If the unit is in domestic hot water production mode, a “DHW” message is displayed on the user interface next to the current operating mode. Example: “Local Running DHW”. 5.11.6 – Summer mode The summer mode is activated when the outside temperature exceeds the parameter threshold summ_oat during the summ_on time. It is deactivated if the outside temperature returns to a lower value than the parameter threshold summ_oat during the summ_off time. The summer mode can also be activated if the volt-free contact SUMM_SW is closed. 5.11.7 – Additonal water pump An additional water pump, installed in the heating water circuit starts if the summer mode is deactivated. If the anti-stick function is configured, the additional water pump starts periodically. 5.12 - Condensing pressure control - 30WG unit in cooling mode The control can regulate the following configurations: • Drycooler and variable-speed condenser pump. The fixed fan stages and the pump speed are controlled to maintain a fixed condensing setpoint (value adjustable). • Variable-speed condenser pump (without drycooler control). The condenser pump integrated into the unit is controlled to maintain a fixed condensing setpoint (value adjustable). • Drycooler and three-way valves. The fixed fan stages and the three-way valve position are controlled to permit start-ups at low outside temperatures and maintaining a fixed condensing setpoint (value adjustable). • Three-way valve only (without drycooler control). The position of the three-way valve is controlled to maintain a fixed condensing setpoint (value adjustable). • Drycooler only (fixed or variable speed). Only the drycooler fan stages are controlled by reference to a fixed drycooler water outlet (value adjustable). The condensing setpoint is adjustable with item cond_sp in the SETPOINT table (SETPOINT menu, chapter 4.9.4). The condensing setpoint can be reset by reference to the outside temperature to optimise the operation of the condensing system. To set the condensing setpoint reset, the following adjustments are necessary: • item hr_sel = 2 (HCCONFIG menu, chapter 4.9.21), • items oathr_no, oathr_fu et hr_deg (RESETCFG menu, chapter 4.9.23).
6 - DIAGNOSTICS - TROUBLESHOOTING 6.1 - General The Pro-Dialog+ control system has many fault tracing aid functions. The local interface and its various menus give access to all unit operating conditions. If an operating fault is detected, an alarm is activated and an alarm code is stored in the Alarms menu, sub-menus CUR_ALRM and ALARMRST. 6.2 - Displaying alarms The alarm LED on the interface (see chapter 4.1) allows the quick display of the unit status. • A flashing LED shows that the circuit is operating but there is an alert. • A steady LED shows that the circuit has been shut down due to a fault. The ALARMRST menu on the main interface displays up to five fault codes that are active on the unit. 6.3 - Resetting alarms When the cause of the alarm has been corrected the alarm can be reset, depending on the type, either automatically on return to normal, or manually when action has been taken on the unit. Alarms can be reset even if the unit is running. This means that an alarm can be reset without stopping the machine. In the event of a power supply interrupt, the unit restarts automatically without the need for an external command. However, any faults active when the supply is interrupted are saved and may in certain cases prevent a circuit or a unit from restarting. A manual reset must be run from the main interface via the ALARMRST menu, item RST_ALM. Depending on the configuration in the GENCONF menu, access to the item may be protected by a password.
21
6.4 - Alarm codes Alarm Alarm Alarm description No. code Thermistor faults 1 th-01 Fluid sensor fault, evaporator water outlet 2 th-02 Fluid sensor fault, evaporator water inlet 3 th-06 Fluid sensor fault, condenser water outlet 4 th-07 Fluid sensor fault, condenser water inlet 5 th-10 Outside temperature sensor fault 6 th-11 HTWSTEMP fluid sensor fault (master/slave) 7 th-12 Suction sensor fault, circuit A 8 th-13 Suction sensor fault, circuit B 9 th-32 CHWSTEMP fluid sensor fault (master/slave) 10 th-36 Fluid sensor fault DRY_LWT 11 th-44 Sensor fault, discharge circuit A 12 th-45 Sensor fault, discharge circuit B Pressure transducer faults 13 Pr-01 Discharge pressure transducer fault, circuit A 14 Pr-02 Discharge pressure transducer fault, circuit B 15 Pr-04 Suction pressure transducer fault, circuit A 16 Pr-05 Suction pressure transducer fault, circuit B 17 Pr-24 Entering evaporator water pressure sensor fault 18 Pr-25 Leaving evaporator water pressure sensor fault 19 Pr-26 Entering condenser water pressure sensor fault 20 Pr-27 Leaving condenser water pressure sensor fault Communication with the slave boards 21 CO-BB Communication loss with the NRCP2 board
Reset type
Probable cause
Action taken by the control
Automatic when the temperature measured Defective thermistor by the sensor returns to normal As above As above
Unit is shut down
Automatic when the temperature measured Defective thermistor by the sensor returns to normal As above As above
Unit is shut down
As above As above
As above As above
As above As above As above
As above As above As above
As above As above As above
As above As above As above
Unit is shut down The master/slave mode is stopped Circuit is shut down As above The master/slave mode is stopped Unit is shut down Circuit is shut down Circuit is shut down
Automatic when the voltage transmitted by the sensor returns to normal As above
Defective transducer or installation fault As above
Circuit is shut down
As above
As above
As above
As above
As above
As above
Automatic when the voltage transmitted by the sensor returns to normal Automatic when the voltage transmitted by the sensor returns to normal As above
Defective transducer or installation fault Defective transducer or installation fault As above
Circuit is shut down
As above
As above
As above
Automatic when communication is re-established
Installation bus fault or defective slave board
Communication loss with the EXV board Communication loss with the PD-AUX 1 board
As above
As above
Depending on the configuration, compressor A3 is shut down or circuit B is shut down. Unit is shut down
As above
As above
As above
As above
As above
Circuit is shut down As above
22
Co-e1
23
Co-o1
24
Co-o2
Communication loss with the PD-AUX 2 board
As above
As above
25
Co-o3
As above
As above
26
Co-o4
Communication loss with the PD-AUX 3 board Communication loss with the PD-AUX 4 board
As above
As above
Water heat exchanger frost protection Low suction temperature, circuit A
Automatic if the same alarm has not tripped during the last 24 hours, otherwise manual. Automatic when the temperature returns to normal, and if this alarm has not appeared during the last 24 hours, otherwise manual. As above As above As above As above As above Automatic if the unit is in manual shut-down status, otherwise manual. Automatic if the unit is in manual shut-down status, otherwise manual. Manual
Water flow rate too low or defective Unit is shut down thermistor Pressure sensor defective, EXV Circuit is shut down blocked or low refrigerant charge As above As above As above As above As above Heat exchanger pump defect or water flow switch fault Heat exchanger pump defect or water flow switch fault Connection problem
As above As above As above As above As above Unit is shut down
As above
As above
As above
As above
As above
As above
As above
As above
As above
As above
As above
As above
Automatic when communication is re-established
CCN installation bus defective
Unit goes into autonomous mode
Process faults 27 P-01 28
P-05
29 30 31 32 33 34
P-06 P-08 P-09 P-11 P-12 P-14
35
P-15
36
P-16
37
P-17
38
P-18
39
P-20
40
P-21
41
P-29
22
Low suction temperature, circuit B High superheat, circuit A High superheat, circuit B Low superheat, circuit A Low superheat, circuit B Water flow control and customer interlock fault Condenser water flow control fault Compressor A1 not started or no pressure increase registered Compressor A2 not started or no pressure increase registered Compressor A3 not started or no pressure increase registered Compressor B1 not started or no pressure increase registered Compressor B2 not started or no pressure increase registered Communication loss with the System Manager
Unit with optional water pressure sensors, unit is shut down Unit with optional water pressure sensors, unit is shut down Unit with drycooler, unit is shut down Unit with optional electric heater stages, unit is shut down
Unit is shut down Compressor is shut down
6.4 - Alarm codes (cont.) Alarm No. Alarm Alarm description code Process faults (cont.) 42 P-30 Communicaiton loss between master and slave 43 P-31 CCN emergency stop 44 P-37 Repeated high-pressure unloading, circuit A 45 P-38 Repeated high-pressure unloading, circuit B 46 P-40 Repeated low suction temperature unloading 47 P-41 Repeated low suction temperature unloading 48 P-43 Temperature at heat exchanger too low, less than 10°C prevents unit start-up 49 MC-nn Master chiller configuration error
Reset type
Probable cause
Action taken by the control
Automatic when communication is re-established Manual Automatic
CCN installation bus defective
Unit goes into autonomous mode
Network command Transducer defective or fan circuit fault As above
Circuit is shut down None
Pressure sensor defective or refrigerant charge too low As above
Circuit is shut down
Operating compressor protection out of range or pressure sensor fault Master/slave configuration error
The unit cannot start
Unit is shut down
As above
The unit size has not been configured The unit size has been configured with the wrong value The preventive maintenance date has passed Fault in the variable speed controller As above
Automatic if the calibration is valid
No calibration
As above
As above Manual As above
50
FC-n0
51
FC-01
Automatic if the temperature detected returns to normal or when the mode returns to cooling Automatic when the master configuration returns to normal or when the unit is no longer in master/slave mode No factory configuration Automatic when the configuration is entered Illegal factory configuration number Manual
52
Sr-00
Maintenance service alert
Manual
53
V3-xx
Automatic
54
V4-xx
55
P62-2
Fault, variable evaporator water pump controller Fault, variable condenser water pump controller Evaporator water loop control fault, missing sensor calibration Water loop control fault, suction pressure too low
P62-3
P62-4 P62-5 P62-6 P62-7 P62-8 56
P61-2 P61-3
P61-4 P61-5 P61-6 P61-7 P61-8 57 58 59
P-63 P-64 P-97
60
P-99
Water loop control fault, water pump has not started Reserved Water loop control fault, water pump overload Water loop control fault, water flow rate fault Water loop control fault, water pressure sensors mixed up Evaporator water loop control fault, missing sensor calibration Water loop control fault, suction pressure too low Water loop control fault, water pump has not started Reserved Water loop control fault, water pump overload Water loop control fault, water flow rate fault Water loop control fault, water pressure sensors mixed up High pressure fault in circuit A High pressure fault in circuit B Reversed evaporator entering/ leaving water sensors Reversed condenser entering/ leaving water sensors
Automatic the first time, if the water Too little water in the system system is supplied with water, the second time manual if it is the same day Manual Pump fault Automatic
As above
As above
Master/slave mode is stopped
As above
Unit is shut down As above
Unit is shut down
As above
Manual
Missing pressure head at the water Unit is shut down pump Serious water leak, pump faulty Unit is shut down
Automatic
Sensors mixed up
Unit is shut down
Automatic if the calibration is valid
No calibration
As above
Automatic the first time, if the water Too little water in the system system is supplied with water, the second time manual if it is the same day Manual Pump fault Automatic
Unit is shut down
As above
Manual
Missing pressure head at the water Unit is shut down pump Serious water leak, pump faulty Unit is shut down
Automatic
Sensors mixed up
Manual As above Manual
Fan fault Circuit is shut down As above As above Sensor defective, sensors reversed Unit is shut down
Manual
Sensor defective, sensors reversed Unit is shut down
Unit is shut down
23
Order No. 16123-76, 02.2012. Supersedes order No.: New. Manufacturer reserves the right to change any product specification without notice.
Manufactured by: Carrier SCS, Montluel, France. Printed in the European Union.