6250fm Series Installation Instructions

   EMBED


Share

Transcript

Sentrol 6250FM Series Flush Mount SureShot TM PIR Installation Instructions Models 6255FM, 6257FM Lens PET ALLEY Sliding LED cover ® Tamper switch (6257FM only) Mounting screws Terminal block LED Flush mount cover plate WID ANGLE E V E R T I C A L B A R R I E R PET SPO T ALLE Y Masking kit 1 Single gang box (not included) Installing the Flush Mount Sureshot Note: The masks have two notches to prevent incorrect installation. One notch matches a rib in the front cover. The second notch matches a dimple in the lens. Avoid False Alarm Sources Sunlight or reflected sunlight Hot or cold air directed onto sensor Align notch with dimple Align notch with rib WIDE ANGLE Pets Intermittent heat sources Inside of front cover For false-alarm-free operation, a PIR should not “see" sources of heat or cold. Masking 1. Choose the mask you need, if any. Note: To correctly mount the Pet Alley Mask, the lens must be removed from the front cover and rotated 180o. 2. Press in on side latches of unit and pull the back cover off. SIDE VIEW Strain Relief Hanger Rotate lens 180° PET ALLEY Side Latches ROTATE LENS 180o Terminal Block Align notch with dimple Inside of front cover 3. Insert the mask behind lens on front cover by pressing over four mounting pins. Once back cover is snapped back on, the mask will be held tight against the lens. Note: 4. Replace back cover and proceed with mounting. Mounting The unit can be mounted into a standard single gang electrical box, a remodel single gang box, or a rough-in plate. It can be mounted in the wall or on the ceiling. The following directions apply to any of the above. 1. Feed wire through the single gang box or rough-in plate and hook up to the terminals on the back of the unit. 2. Connect wires per “wiring” diagrams on following pages. 3. Tie the wire to the strain relief hanger on the back of the unit using the tie wrap provided in the box. 4. Place the cover plate over the unit and set into the single gang box or rough-in plate. 5. Tighten screws on the cover plate. 6. After walk testing, the LED cover can be slid up to cover the LED. When mounting on the ceiling, align the unit to maximize the oblong detection pattern for the room. Always use “center spot” mask when mounting on ceiling. Capture zone at 8' mounting height 20' 2 15' ZONE PATTERNS Wall Mount–No Mask With "Vertical Barrier" Mask 29 Zones 58 Beams 7 Zones 14 Beams Top View 54° Side View 38.4° 20° Side View +54° 0' Top View +38.4° 0° +18° 0' 10° 20° 54° 7' 2.13m 38.4° 0' 40' 12.19m 5.9° 0' 30' 9.14m 7' 2.13m 10' 20' 30' 40' 3.04m 6.09m 9.14m 12.19m 10' 20' 30' 40' 3.04m 6.09m 9.14m 12.19m 40' 12.19m With "Wide Angle" Mask Top View With "Pet Alley" Mask 18 Zones 36 Beams 7 Zones 14 Beams Top View Note: Lens must be inverted for pet alley 0' 90° 0' 90° Side View Side View 7' 2.13m 30' (9.14m) 3' .91m 0' 40' (12.19m) 40' 10' 20' 30' 3.04m 6.09m 9.14m 12.19m Ceiling Mount–Center Spot Mask Capture Zone 29 Zones 58 Beams 0' 40' 12.19m 30' 9.14m 40' 10' 20' 30' 3.04m 6.09m 9.14m 12.19m Wiring Strip back the outer jacket on your wiring cable. This will allow wires to flex in the case. Use cable strain relief built into back cover to prevent stressing wires at their connection. 8' (2.4m) 15' (4.59m) X 20' (6.12m) capture zone 6255FM Model – NC COM – + Power-In 7 to 16 VDC + 25' diameter (7.5m) coverage pattern NO COM T/NO Tamp Note: Intruder must enter capture zone in order to be detected. False alarm sources, such as heaters, should be kept out of the coverage pattern. Be sure to insert center spot mask to reduce potential for false alarms. 6257FM Model With "Single Spot" Mask Top View 1 Zone 2 Beams Note: The unit should be connected to a UL listed power supply, capable of providing four hours of standby power. Side View 10° 0' Power-In 7 to 16 VDC 40' 12.19m 7' 2.13m 0' 7° 10' 20' 30' 40' 3.04m 6.09m 9.14m 12.19m 3 SPECIFICATIONS FEATURES Pulse Count ......................... Bi-directional, 1 zone (2 pulses) with Motion Verification Capture Zone (at 70½ F) Wide Angle (90½) ................... 30' (9.14m) x 30' (9.14m) Single Spot ...................................... 40' (12.19m) range Vertical Barrier ................................. 40' (12.19m) range Pet Alley (90½) ................................... 30' (9.14m) range 360°Ceiling ...... 15' x 20' (4.57m x 6.10m) at 8' (2.44cm) mounting height ....... 16' x 30' (4.88m x 9.14m) at 12' (3.65m) mounting height .... Ceiling mounting height up to 12' (3.65m) Mounting ............................................ Wall, corner, or ceiling LED indicator ............................................................ Walktest Size ...................................................... 2.75" (6.99cm) Width 4.50" (11.43cm) Height 1.63" (4.13cm) Total Depth 1.37" (3.49cm) Depth behind wall 0.25" (0.64cm) Depth in front of wall Color .................................................................. White/White ELECTRICAL Voltage ............................................................... 7 to 16 VDC Current ............................................ 8 mA typical, 10mA max. Maximum relay rating ..................................... 16VDC, 50 mA Alarm output ............. Fail safe contacts w/ 10 ohms in series, 6255FM - Form A, Normally Closed (NC) 6257FM - Form C, Normally Closed and Open (SPDT) Alarm duration ................................................ 2 to 5 seconds Cover tamper contacts ................................ Normally Closed, rating: 50 mA, 12VDC (6257FM only) ENVIRONMENTAL Operating Temperature ........... 0°F to 120°F (-17°C to +50°C) Humidity ................................... 10% to 90% noncondensing RFI immunity ...... greater than 10V/meter from 0 to 1000MHz Static/lightning immunity ............. 2.5KV, 2 joules max energy impulse, 1 msec rise / 50 msec decay NOTE: This unit will fit in most standard single gang electrical boxes or rough-in plates, available at any electrical supply store. Front View Side View 1.63" 4.13 cm 2.75" 6.99 cm 4.50" 11.43 cm 4.5" 11.43 cm ® .25" 0.64 cm 1.37" 3.49 cm ORDERING INFORMATION PART NUMBER 6255FM 6257FM LOOP TYPE Normally Closed Normally Closed or Open ELECTRICAL CONFIGURATION N.C. – Form A SPDT (N.C. and N.O.) – Form C CORPORATE HEADQUARTERS 12345 SW Leveton Dr. Tualatin, OR 97062 Tel.: 503.692.4052 Fax: 503.691.7566 SENTROL U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 FaxBack: 800.483.2495 COMMENTS LISTING No Tamper Incl. Tamper UL UL Sentrol reserves the right to change specifications without notice. © 2000 Sentrol 13048 Rev. B 06/00