Transcript
STANDARD FEATURES • • • • • • • • • • • • • • • • • • • • • •
NEW Factory authorized startup ENERGY STAR® Qualified Dual-pawl cradle drive system One-piece cast stainless steel upper & lower spray arm assemblies Internal removable scrap basket and two-piece scrap screen Standard vertical opening accommodates 18" x 26" sheet pans Wide leakproof swing out insulated hinged doors on wash/rinse Anti-jam conveyor drive system Energy Sentinel (Idle pump shut-off) Convenient top-mounted controls Automatic tank fill Door safety switch Never leak, ball valve drain closure Enclosure panels (front and sides) Stainless steel heavy-gauge construction, including base and feet Electric tank heat Wash/rinse pump 2 Hp motors Stainless steel pump and impeller Two-point electrical connection Vent fan control switch Self-diagnostic controls Stainless steel rear manifolds
CH067
PREWASH MODELS ONLY • External prewash scrap basket • Prewash pump 1 Hp motor • 22" Prewash • 26" Prewash • 36" Prewash
Champion Industries, Inc. 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 Tel: 905/562-4195 Fax: 905/562-4618
64 SERIES
64, 86 PW, 90 FFPW, 100 HDPW High-Temperature Rack Conveyor Dishwashing Machine
Model 64 Shown with Vent Cowl and Damper Option
Photo is for general visual representation only. Please refer to specifications for the latest detailed product information.
SPECIFIER STATEMENT Specified unit will be Champion model 64 Series high temperature rack conveyor dishwashing machine. Features top mounted control cabinet; upper and lower one-piece stainless steel spray arm assemblies, removable internal scrap baskets with two-piece scrap screen. Swing out front insulated access doors. Anti-jam conveyor drive system. 1 year parts and labor warranty.
Champion Industries, Inc. 3765 Champion Blvd., Winston-Salem, NC 27105 Tel: 336/661-1556 Fax: 336/661-1979 www.championindustries.com
(1M) 12/15 Printed in U.S.A. Champion, an Ali Group Company
64 SERIES RACK CONVEYOR
Project Item No. Quantity
17-3/8"
1A
2"
2
4-1/2"
1-1/2"
3-1/4"
3
4A
4A
64 SERIES 16"
26-1/2"
1A
2"
2
4-1/2"
3-1/4"
4B
1A
4-7/8"
46-5/8"
1-1/2"
4B
4-7/8"
16"
1A
26-1/2"
27" Door Opening Clearance
27" Door Opening Clearance
64, 86 PW, 90 FFPW, 100 HDPW High-Temperature Rack Conveyor Dishwashing Machine
-B-A-DTM3-
-A-
-A-
50-1/4" Inside
MODEL 64
50-1/4" Inside
36-3/8"
1200 lbs.
Shipping weight crated:
64"
8" 8A
13" Plumbing Clearance
4"
E22PW
8"
8"
8B
8A
3"
E26FFPW 64"
8" 8B
90-1/4" 4" Vent Stack Distance
4"
2
Dimensions shown in inches [mm]34-1/4"
6"
1A
13" 87-5/8" Plumbing Clearance Vent Stack Distance
4" 3" 2
6"
1A
7-1/4"
7-1/4"
21-7/8" Opening
20" side Track
3-1/4" 58" Machine Height
2-1/2" 3
34" Load Height
9" 11-1/8" 5" 7-1/4" 4-1/4"
5
12-1/2"
6
29-3/4"
6
1B
17"
17"
4B
4B
11-1/8" 9" 7-1/4" 5" 4A 6-1/2"
4A
6
5
12-1/2"
3
1B
86"
22-5/8"
4A
23-7/8"
40-1/8"
7
32"
53-1/2"
5
7
5
2"
4-1/2"
2
2"
1A
2"
3
17-3/8"
1-1/2"
3-1/4"
4A 4B
4A
3-1/4"
E90FFPW
4A 4B
29-1/2"
1A
2"
2
16"
26-1/2"
1-1/2"
2
46-5/8"
1-1/2"
3
17-3/8" 2"
1A
54-1/8" 3
4-1/2"
1A
4-7/8" 3-1/4"
4B
1A
4-7/8"
2"
2"
2
4-1/2"
16"
26-1/2"
68-1/4" 54-1/8" Vent Stack Distance
2
54-1/8"
2
2"
E86PW E64
68-1/4" Vent Stack Distance
29-3/4"
Front View Right to Left
16" Door
4B Clearance
68-1/4" Vent Stack 53-1/2" Distance
8-3/4"
5
90"
2"
E64
8-5/8" 5
4-1/4"
6
22-5/8"
4A
32"
4B
Front View Left to Right
3
8-1/4"
3 2-1/2"
20" Inside Track
3-1/4" 58" Machine Height
8-1/4"
8-1/4" 34" Load Height
"
21-7/8" Opening
20" Clearance
20" Clearance
4-7/8"
16"
1A
26-1/2"
27" Door Opening Clearance 27" Door Opening Clearance
Plan View Left to Right
Plan View Right to Left
27" Door Opening Clearance
50-1/4" Inside
-B-A-DTM3-
-A-
-A-
50-1/4" Inside
50-1/4" Inside 36-3/8"
8"
64"
8" 13" Plumbing Clearance
8A
4" 2
4" 3"
1A
6"
21-7/8" Opening 20" Inside Track
/4"
58" Machine Height
End View
58" Machine Height
64" 1A
3"
8A 1-1/2" 90-1/4"4" Can be up Vent Stack Distance to 10"
8"
4-1/4"
6
29-3/4"
4A
12-1/2" 22-5/8"
1B
6"
1A
5
6
4A
17"
17"
4B
4B
1-3/4"
4-1/4" 11-1/8" 9" 7-1/4" 5" 4A
6-1/2"
13" Plumbing Clearance
6
5
1B
21-7/8" Opening
2-1/2" 3
5/8" 8-1/4"
3
34" 9" 11-1/8" 5" 7-1/4" Load Height
2-1/4"
21"
12-1/2"
6
4A 86"
6 4B
22-5/8" 7
1B
6
4A
53-1/2"
4-1/4"
32"
53-1/2"
4B
5
6-1/2"
8-5/8" 5
5
90"
40-1/8"
E64
17"
22-5/8"
4A
12-1/2"
3
20" Inside Track
3-1/4" 58" Machine Height
23-7/8" Due to an ongoing value4Banalysis32"program at Champion, specifications contained in this catalog are subject 5 753-1/2"to change without notice. Champion Industries, Inc.,7 3765 Champion Blvd., Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 •4Bwww.championindustries.com 32" 40-1/8" 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618 5
87-5/8"
Vent Stack Distance
3" 2
3 2-1/2"
9" 11-1/8" 5" 7-1/4" 29-3/4" 3
8B
4"
Suggested Table Construction 20"
2-1/2" 3 8-3/4"
6"
Clearance 8-1/4"
8-1/4"
6" Nominal Wall Clearance
8"
7-1/4"
34" 8-1/4" Load Height
34" Load Height
5
2
4"
20" Clearance
3-1/4"
20" Clearance
3-1/4"
8"
E26FFPW
8B
4"
7-1/4"
2-1/2"
20" nside Track
8A
8B
7-1/4" 21-7/8" Opening
E22PW
13" Plumbing Clearance
E
34-1/4" 8"
64"
8"
5
8-3/4"
29-3/4"
E8
3-1/4"
4A 4B
16"
1A
26-1/2"
64 SERIES
27" Door Opening Clearance
64, 86 PW, 90 FFPW, 100 HDPW High-Temperature Rack50-1/4" Conveyor Dishwashing Machine Inside
-B-A-DTM3-
-A-
-A-
26" Door Clearance
36-3/8"
16" oor arance
MODEL 86 PW WITH 22" PREWASH E22PW
8"
64"
36-3/8"
Dimensions shown in inches [mm]
E22PW
E26FFPW
1375 lbs.
Shipping weight crated:
34-1/4"
36-3/8"
34-1/4"
E36HDPWE26FFPW
8"
8A
8B
4"
4" 90-1/4"
6"
1A
16" Vent Stack Distance Door 3" 2 Clearance 29-1/2"
13" Plumbing Clearance
21-7/8" Opening
2-1/2"
87-5/8" 26" Door Vent Stack Distance Clearance
Front View
20" Inside Track
3-1/4" 58" Machine Height
1/4"
104-1/4"
Vent Stack Distance
29-1/2"
7-1/4"
20" Clearance
1/2"
90-1/4"
Vent Stack Distance
87-5/8"
Vent Stack Distance
2-1/2"
8-1/4"
8-1/4"
8-1/4"
8-1/4"
34" Load Height
27" Opening earance
9" 11-1/8" " 5"
Left to Right
17" -B-A-DTM3-
Right to Left
-A-
-A-
26" Door Clearance
4B
36
4A
12-1/2"
6
5
4-1/4"
6-1/2"
86"
22-5/8"
4A
36-3/8"
34-1/4"
23-7/8"
8-3/4"8-5/8" 5
5
5 2-1/2"
6" Nominal Wall Clearance
29-3/4"
90"
8-1/2"
5
100"
86" 34-1/4"
36-3/8"
90"
36-3/8
7
MODEL 90 FFPW WITH PREWASH E22PW26" FRONT FEED E26FFPW E26FFPW E36HDPW
32"
E36HD
4B
53-1/2" 5 Shipping weight crated:
1400 lbs.
E64E86PW
" umbing earance
E90FFPW
90-1/4"
87-5/8"
Vent Stack Distance
104-1/4" 26"
Vent Stack Distance
E100HDPW E90FFPW
E86PW
Door Vent Stack Distance
29-1/2"
Clearance
104-1/4
87-5/8"
Vent Stack D
Vent Stack Distance
-1/4"
21-7/8" Opening 20" Inside Track
3-1/4"
ne ht
Front View 2-1/2"
8-1/4"
8-1/4"
8-1/4"
8-1/4"
8-1/4"
Left to Right 8-3/4" 8-5/8" 5 6"
5
36-3/8"
22PW
29-3/4"
5 2-1/2"
Nominal Wall Clearance
90" 36-3/8"
34-1/4"
8-1/4"
Right to Left 8-1/2"
5
5 4-5/8"
100"
86"
100"
90" 36-3/8"
MODEL 100 FFPW WITH 36" HEAVY DUTY PREWASH E26FFPW E36HDPW E36HDPW 1550 lbs.
Shipping weight crated:
E90FFPW
90-1/4"
104-1/4"
t Stack Distance
Vent Stack Distance
E100HDPW E90FFPW
E86PW
E100H
104-1/4"
87-5/8"
Vent Stack Distance
Vent Stack Distance
Front View
8-1/4"
8-1/4"
8-1/4"
8-1/4"
Left to Right 5 2-1/2"
86"
8-1/2"
5
Right to Left 5
5 4-5/8"
100"
90"
14-1/2"
100"
NOTE: For complete machine dimensions, plan view, end view, specifications and table construction see 64 drawing page.
64 SERIES 64, 86 PW, 90 FFPW, 100 HDPW High-Temperature Rack Conveyor Dishwashing Machine
Dimensions shown in inches
Utilities 1 Electrical Connection
A Machine electrical connection B Booster electrical connection
2 Hot Water
Main connection 3/4" NPT
3 Cold Water
Contact Factory
4 Hot Water Tank
A Heat inlet connection 1" NPT B Heat return connection 1" NPT
5 Drain
Connection 1 1/2" NPT
6 Steam
64 ONLY TABLE A - Machine Connection Machine only Elec. Specs.
Rated Amps
Minimum Supply Ckt. Conductor Ampacity
Minimum Overcurrent Protective Device
Elec. Specs.
208/60/3
90
110
110
208/60/3
95
125
125
240/60/3
80
100
100
240/60/3
83
100
100
480/60/3
40
50
50
480/60/3
41
50
50
575/60/3
31
40
40
575/60/3
32
40
40
64 ONLY TABLE B - Booster Connection 40°F/22°C Rise – 15 kW Electric built-in booster (booster only)
Inlet connection 1 1/4" NPT
7 Condensate
Connection 1" NPT return to boiler
8 Vents A B
Stack connection - Load end 200 CFM @ 1/4" static pressure Stack connection - Unload end 400 CFM @ 1/4" static pressure
Warning: Plumbing and electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary, safety codes and the National Electrical Code. Note: Water Hammer Arrestor (meeting ASSE-1010 standard or equivalent) to be supplied (by others) in common water supply line at service connection.
Plumbing Notes: Because of the variation in house-supplied steam and water pressures, steam and water pressure regulating valves (PRVs) may be needed. (Water PRV is standard on machines with booster.) The PRVs can either be purchased from Champion or obtained locally. Venting Notes: Fabricated duct size: 3-7/8" x 15-7/8" (Outside dimensions)
86 PW, 90 FFPW, 100 HDPW TABLE A - Machine Connection Machine only
Elec. Specs.
Rated Amps
Minimum Supply Ckt. Conductor Ampacity
Minimum Minimum Supply Ckt. Overcurrent Rated Conductor Protective Device Amps Ampacity
86 PW, 90 FFPW, 100 HDPW TABLE B - Booster Connection 40°F/22°C Rise – 15 kW Electric built-in booster (booster only)
Minimum Overcurrent Protective Device
Elec. Specs.
Minimum Minimum Supply Ckt. Overcurrent Rated Conductor Protective Device Amps Ampacity
208/60/3
42
50
50
208/60/3
42
50
50
240/60/3
36
45
45
240/60/3
36
45
45
480/60/3
18
25
25
480/60/3
18
25
25
575/60/3
15
20
20
575/60/3
15
20
20
70°F/39°C Rise – 24 kW Electric built-in booster (booster only) Elec. Specs.
Rated Amps
Minimum Supply Ckt. Conductor Ampacity
70°F/39°C Rise – 24 kW Electric built-in booster (booster only)
Minimum Overcurrent Protective Device
Elec. Specs.
Minimum Minimum Supply Ckt. Overcurrent Rated Conductor Protective Device Amps Ampacity
208/60/3
67
80
80
208/60/3
67
80
80
240/60/3
58
70
70
240/60/3
58
70
70
480/60/3
29
35
35
480/60/3
29
35
35
575/60/3
24
30
30
575/60/3
24
30
30
Machine and steam built-in booster Elec. Specs.
Rated Amps
Minimum Supply Ckt. Conductor Ampacity
Machine and steam built-in booster
Minimum Overcurrent Protective Device
Elec. Specs.
Minimum Minimum Supply Ckt. Overcurrent Rated Conductor Protective Device Amps Ampacity
208/60/3
15
20
20
208/60/3
20
25
25
240/60/3
14
20
20
240/60/3
17
25
25
480/60/3
7
15
15
480/60/3
9
15
15
575/60/3
6
15
15
Contact factory for single phase information.
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Blvd., Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618
64 SERIES 64, 86 PW, 90 FFPW, 100 HDPW High-Temperature Rack Conveyor Dishwashing Machine
SPECIFICATIONS Capacity
Racks per hr. (NSF rated) Wash tank (US gal.) Conveyor speed (ft/min.)
Motor Horsepower Drive Wash Rinse
Water Consumption
US Gal. per hr. (max. use) US Gal. per rack
Heating
Tank Heat, electric (kW) Tank heat, steam (lbs/hr. required at 15 PSI flow pressure) Electric booster (built-in) (kW supplied for 40°F rise) Electric booster (built-in) (kW supplied for 70°F rise) Steam booster (lbs./hr. required for 40°F rise) Steam booster (lbs./hr. required for 70°F rise)
277 21 7.7 1/6 2 2 124 .45
Load end (minimum CFM) Unload end (minimum CFM)
Standard 20" x 20" rack complement Peg Flat
www.championindustries.com
NEW Durable Stainless Steel Start/Stop Switches
One-Piece Cast Stainless Steel Spray Assembly
Stainless Steel Built-in Nested Booster
Two-Piece Scrap Screen
Built-in Scrap Basket for ease of cleaning
25 125 15 24 75 120
Booster heaters completely inter plumbed, Controls are interwired
Venting
NEW Exclusive Digital Gauges
200 400
2 1
MODEL 64 RACK CONVEYOR
64 SERIES 64, 86 PW, 90 FFPW, 100 HDPW High-Temperature Rack Conveyor Dishwashing Machine
OPTIONS & ACCESSORIES :: Tank heat: choice of steam coil, steam injector, hot water coil :: 2 Hp prewash motor :: 48" Blower-dryer - steam or electric :: Booster Heaters (completely interplumbed, controls are interwired) :: Steam: 40°F or 70°F rise :: Electric: 15 kW (40°F rise) (built-in only) :: Electric: 24 kW (70°F rise) (built-in only) :: Heat Recovery Cantilever sideloader (with or without hood) for 90° load operation :: 24" Sideload
NEW CCT 90
90° Corner Conveyor Table (shown)
NEW CCT 180
180° Corner Conveyor Table also available
:: 30" Sideload (accepts sheet pans) :: Extended pawl bar (extended drive unit) for use with load tabling
Cantilever Sideloader
:: Racks: peg or flat racks (specify type) :: Steam pressure regulating valve (unmounted)
(No hood)
:: Table limit switch, unmounted (recommended on all rack conveyor installations) :: Vent cowl, stainless steel with 7" stack and locking damper :: Extended vent hood, stainless steel with 7" stack and locking damper :: Water pressure regulating valve (unmounted) (standard with booster) :: Water hammer kit :: Drain tempering kit :: Vertical clearance through machine: 24" (instead of standard 20") for larger ware :: Model CCT 180 (180° Corner Conveyor Table) :: Model CCT 90 (90° Corner Conveyor Table) :: Model RCT 64 or RCT 84 Roller Conveyor Table (See factory for custom length)
Model RCT 64 or RCT 84 Roller Conveyor Table
:: Splash Shields ::NEW Champion ION scale prevention system
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. ‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. Champion Industries, Inc., 3765 Champion Blvd., Winston-Salem, NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 905/562-4195 • Fax: 905/562-4618