Transcript
DynaLock For Life
TM
SM
6420 Series
Passive Infrared Request-To-Exit Sensor • • • •
Selectable Input Voltage Single or Double Door Coverage Two Relay Output Contacts Adjustable Relay Hold Time
Description
Standard Features
The DynaLock Series 6420 passive infrared Request-To-Exit sensor detects the differential between a human body and the floor. Featuring a dual-pyroelectric design, for increased stability against external light, the 6420’s pyramid-shaped detection field is positionable from straight-down vertical to 35° in front of the door and special circuitry provides high immunity to RFI and other electrical noise. Two, built-in SPDT dry relay output contacts are rated for 1 Amp @ 30VDC and an adjustable timer may be set for from 0.25 to 60 seconds of relay hold time. Additionally, the output relay’s mode may be set for fail-safe or fail-secure operation and an on-board LED indicator may be set to illuminate during relay hold time.
• Adjustable Coverage Area: Angle adjustment from straight-down vertical to 35° in front of door. • Single or Double Door Coverage: Adjustable, two-position mirror. • Two SPDT Relay Output Contacts: Rated 1 Amp @30VDC. • Adjustable Relay Timer: Adjusts for 0.25 to 60 seconds of relay hold time. • Fail-Safe or Fail-Secure Relay Mode: DIP switch-selectable. • Paintable, Snap-on Housing Cover: Easy to install and service, with built-in wire trough. • Selectable Input Voltage: Accepts 12 to 24 VAC/VDC. • 5 Year Limited Warranty
The 6420 accepts 12 to 24 VAC/VDC input power and is designed for wall, ceiling or door frame mounting. It is ideally suited for access control, lock release, alarm shunting and automatic door operation.
LIFE SAFETY PRODUCTS
F U L LY I N T E G R AT E D S E C U R I T Y S Y S T E M S Electromagnetic Locks Controls Power Supplies
6 4 2 0 S e r i e s P a s s i v e I n f r a r e d R e q u e s t - To - E x i t S e n s o r
Specifications
Detection Area WALL OR FRAME MOUNT
6420 REQUEST TO EXIT SENSOR DETECTION SYSTEM
PASSIVE INFARED
DETECTION AREA
13’ (4m) MAX MOUNTING HEIGHT SINGLE DOOR OR DOUBLE DOOR, SELECTABLE PATTERN ADJUSTABLE RANGE: WALL MOUNT VERTICALLY 35° ADJUSTABLE RANGE: OVERHEAD MOUNT VERTICALLY 20° ADJUSTABLE SENSITIVITY
POWER SUPPLY
12 TO 24VDC (NON PALARITY) OR 12 TO 24VAC (5OHz/60Hz) (WHEN OPERATED AT AC20 TO 24V CONNECT ATTACHED RESISTOR)
POWER CONSUMPTION
40mA OR LESS/DC 70mA OR LESS/AC
OUTPUT
DRY CONTACT RELAY (2) SPDT OPERATION HOLD TIME: ADJUSTABLE 0.25 SEC TO 60 SEC CONTACT CAPACITY: 30V (DC) 1A OR LESS 125V (AC) 0.6A OR LESS SELECTABLE RELAY OPERATION: FAIL SAFE OR FAIL SECURE
LED
GREEN OPERATION: SYNCHRONOUS DRY CONTACT RELAY (LED DISABLED)
WIRING CONNECTION
TERMINALS
TEMP. RANGE
+14°F TO +122°F (-10°C TO +50°C) WITHOUT CONDENSATION
MOUNTING POSITION
WALL, CEILING ON OR UNDER FRAME (INDOOR)
WEIGHT
5.95 oz (170g)
APPEARANCE
WHITE BODY (ABS RESIN) WHITE WINDOW (PE RESIN)
ACCESSORIES
TAPPING SCREW: (2PCS) COVER LOCK SCREW (1PC) RESISTOR: (1PC) CONNECT WHEN OPERATED AT AC20 TO 24V (82 OHMS, 3W)
ADJUSTABLE
DOUBLE DOOR
1.5m 5’
WALL MOUNT
MOUNTING HEIGHT 2.5m 8’
0.8m 2 2/3”
0.5m
1.2m 4’
2.4m 8’
SIDE
HEIGHT
1
35°
2 3 4m
FRONT CEILING MOUNT
ADJUSTABLE
DOUBLE DOOR
1.5m 5’
SINGLE DOOR
MOUNTING HEIGHT 2.5m 8’
0.8m 2 2/3” 1.2m 4’
2.4m 8’
SIDE
HEIGHT
1
20° 0.5m
Installation
SINGLE DOOR
2 3 4m
FRONT
External Dimensions OVERHEAD MOUNT
6.30” (160mm)
2.36” (60mm)
MOUNT THE UNIT IN THE CENTER OF DOOR
1.57” (40mm)
DYNALOCK CORPORATION 705 EMMETT STREET / PO BOX 2728 BRISTOL, CT 06011-2728 PHONE: 877-DYNALOCK / FAX: 860-585-0338 E-MAIL:
[email protected] WEBSITE: WWW.DYNALOCK.COM
Featuring
DynaLife
®
Lifetime Warranty
3/11