Preview only show first 10 pages with watermark. For full document please download

6fm250z-x 12v 250ah(10hr)

   EMBED


Share

Transcript

6FM250Z-X 12V 250Ah(10hr) The rechargeable batteries are lead-lead dioxide systems. The dilute sulfuric acid electrolyte is absorbed by separators and plates and thus immobilized. Should the battery be accidentally overcharged producing hydrogen and oxygen, special oneway valves allow the gases to escape thus avoiding excessive pressure build-up. Otherwise, the battery is completely sealed and is, therefore, maintenance-free, leak proof and usable in any position. Battery Construction Component Positive plate Negative plate Container Cover Safety valve Terminal Separator Electrolyte Raw material Lead dioxide Lead ABS ABS Rubber Copper Fiberglass Sulfuric acid General Features ● ● ● ● ● ● ● ● Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance or water adding. Not restricted for air transport-complies with IATA/ICAO Special Provision A67. UL-recognized component. Can be mounted in any orientation. Computer designed lead, calcium tin alloy grid for high power density. Long service life, float or cyclic applications. Maintenance-free operation. Low self discharge. Dimensions and Weight Length(mm / inch) Width(mm / inch) Height(mm / inch) Total Height(mm / inch) Approx. Weight(Kg / lbs) 520 / 20.5 269 / 10.6 221 / 8.7 227 / 8.9 74.0 / 163.1 Performance Characteristics Nominal Voltage 12V Number of cell 6 Design Life 10 years o o Nominal Capacity 77 F(25 C) 10 hour rate (25.0A, 10.8V) 250Ah 5 hour rate (43.5A, 10.5V) 217.5Ah 3 hour rate (66.3A, 10.5V) 198.9Ah 160Ah 1 hour rate (160A, 9.6V) Internal Resistance Fully Charged battery 77oF(25oC) ≤ 3.0mOhms Self-Discharge 3% of capacity declined per month at 20oC(average) Operating Temperature Range Discharge -20~60oC Charge -10~60oC Storage -20~60oC o o 1250A(5s) Max. Discharge Current 77 F(25 C) Short Circuit Current 4300A Charge Methods: Constant Voltage Charge Cycle use Maximum charging current Temperature compensation Standby use Temperature compensation 77oF(25oC) 2.40-2.45VPC 75A -30mV/oC 2.20-2.27VPC -20mV/oC Discharge Constant Current (Amperes at 77oF25oC) End Point Volts/Cell 15min 30min 45min 1h 3h 5h 10h 1.60V 463 274 195 160 72.3 47.2 25.6 1.65V 430 258 186 153 69.5 45.5 25.4 1.70V 415 252 182 150 68.3 44.8 25.3 1.75V 386 240 178 146 66.3 43.5 25.2 1.80V 357 229 176 142 64.2 42.5 25.0 2h 3h 5h Discharge Constant Power (Watts at 77oF25oC) End Point Volts/Cell 15min 30min 45min 1h 1.60V 810 497 361 300 182 135 91.0 1.65V 770 475 347 291 175 133 88.2 1.70V 747 465 343 285 172 131 87.0 1.75V 705 449 332 278 165 127 85.2 1.80V 660 434 325 268 160 123 83.2 (Note)The above characteristics data are average values obtained within three charge/discharge cycles not the mimimum values. page1 of 2 www.vision-batt.com O Current Charged Volume Discharge characteristic (25 C) Voltage 6FM250Z-X Charge characteristic curve Constant voltage charge characteristic (0.25CA,25 oC) (%) (XCA) (V) 12.0 12V250Ah Battery voltage(V) 140 66.3A 43.5A 9.6 25.0A 120 0.25 100 0.20 80 274A 160A 500A 0.15 1 2 3 20 30 5 10 min 60 2 3 5 10 20 0.10 20 0.05 0 0 h CHARGED VOLUME 14.0 CHARGE VOLTAGE 13.0 60 40 0 15.0 12.0 11.0 0 Discharge time (V/8V) (V/6V) (V/4V) (V/CELL) 7.8 5.2 2.6 15.0 10.0 7.5 5.0 2.5 14.4 9.6 7.2 4.8 2.4 9.2 6.9 4.6 2.3 13.2 8.8 6.6 4.4 2.2 CY CL ND B EU SE Y US 14 16 18 20 12 14 16 18 Storage time: months 20 70 60 E 40 oC 30 oC 20 oC 50 0 10 20 30 40 50 Ambient temperature( oC) 40 60 0 2 4 6 8 10 Cycle service life in relation to depth of discharge 120 100 100 Capacity(%) Capacity(%) 12 80 Life characteristics of standby use 80 60 Testing conditions: floating voltage: 2.20 to 2.27V/Cell ambient temperature: 25 oC(77 oF) 80 60 40 40 20 20 0 4 6 Life(year) 100% D.O.D. 0 8 200 30% Depth of discharge 50% D.O.D. 400 600 800 1000 1200 1400 1600 Number of cycles(cycles) Temperature effects on capacity Temperature effects on float life 120 15 100 2.25V/Cell 10 Capacity (%) Life(years) 10 90 120 5 0.1C 0.2C 0 .3 C 80 60 1 .0 C 40 2 .0 C 20 0 8 100 -10 0 6 110 S TA 13.8 4 Self-discharge characteristic Capacity(%) (V/12V) 10.4 2 Charging time (hours) Relationship between charging voltage and temperature 15.6 CHARGING CURRENT 0 10 20 30 40 50 -20 -10 o Temperature( C) THE INTERNATIONAL CERTIFICATION NETWORK ISO9001:2000 MH25860 0 10 20 Temperature( oC) 30 40 G4M19906-9202-E-16 www.vision-batt.com Shenzhen Center Power Tech. Co., Ltd. Center Power Industrial Park, Tongfu Industrial District Dapeng Town, 518120 Shenzhen, China Tel: (+86-755) 8431 8088 Fax: (+86-755) 8431 8038 E-mail: [email protected] Copy Right Shenzhen Center Power Technology Co., Ltd (Version:A0 Edition:2013-6) Page 2 of 2 50