Preview only show first 10 pages with watermark. For full document please download

6” Cob Led Cylinder Wide Beam Reflector

   EMBED


Share

Transcript

6” COB LED Cylinder Wide Beam Reflector CYLINDERS Specular Open Reflector CYL6 DESCRIPTION 6” aperture cylinder light includes high efficacy LED with integral driver. The optical diffusion produces high lumen transmission and even illumination. Designed for long life operation. LED Quantity 1EA (COB) Input Voltage 120V-277V AC Light Engine 13 20 29 Wattage 14W 26W 34W Lumen 1321 2052 2934 95 90 90 48˚ 52˚ 52˚ Efficacy (LPW) Beam Angle° Color 2000K-4000K CRI 80 (standard) Dimming 0-10V Lamp Life Rated for 50,000 hrs at 70% lumen maintenance 10-15/16” (278.4mm) 4-1/4” (107.7mm) 7-7/8” (199.4mm) Ceiling Mount Wall Mount Ordering Information Luminaire Prefix CYL6 - 6" Cylinder Light Accessories Mounting Lumens Source Color Temp Beam Angle (nom.) 13 13 S - Surface LED 27 - 2700K 30 - 3000K 22 - 22º Spot 20 P - Pendant 35 - 3500K 26 - 26º Narrow 29 W - Wall Flood 40 - 4000K 48 - 48º Flood 74 - 74º Wide Flood SELECTION: CYL6 Voltage 20, 29 23 - 23º Spot 35 - 35º Narrow Flood 52 - 52º Flood 75 - 75º Wide Flood LED Reflector Finish HAZ - Haze clear SPC - Specular HAZ BB - Haze black baffle collar HAZ WB - Haze white baffle collar Pendant Stem Length 12 - 12 inches 18 - 18 inches 24 - 24 inches 36 - 36 inches 48 - 48 inches Canopy C - Canopy Note: Not available in silver & for pendant mount only UE Example: CYL6 - S - 29 - LED - 40 - 22 - UE - BK - HAZ Project Name Housing Finish UE - Universal WH - White Input Voltage BK - Black BZ - Bronze (120-277V) SLV - Silver Fixture Type w w w. l s i - i n d u s t r i e s . c o m Cat# 8/3/17 © LSI INDUSTRIES INC. 6” COB LED Cylinder Wide Beam Reflector IP65 CYLINDERS CYL6 Features & Benefits LED Module • Durable aluminium extrusion heat sink integrated with COB (chip on board). • Inner reflector provides more light and beam distribution. • Uniform color temperature to 3SDCM. Housing • Round seamless .060 thick spun aluminum, housing available in semi-matte white, black or silver finish. Heat Sink • Aluminum extruded heat sink facilitates heat dissipation for maintaining constant light output, color and life of solid state components. LED Power Supply Driver • 120-277V input high efficacy driver with dimming • Compatible with Triac (forward-phase or leading edge) / ELV (reverse-phase or trailing edge) and 0-10V dimmers • TRIAC dimming only at 120 Vac. • Deep dimming from 100% down to 1% • Power factor >.90, THD <20% has integral thermal protection. • Driver mounts externally to the module, allowing future replacement, if needed. Wall Bracket • Aluminum casted bracket secured to housing cross-bar by set screws. Warranty • LSI LED Fixtures carry a limited 5-year warranty. Listing • cETLus Approved Dimmers • Lutron: NovaT(Ntelv300&600) Diva(Dvelv-300P&303P) • Leviton: Acenti (Ate06-1Lw) Trimatron #705W Consult factory for additional dimmers Lutron, Nova and Diva are trademarks of Lutron Electronics Co., Inc. Leviton, Acenti and Trimatron are trademarks of Leviton Manufacturing Co., Inc. Photometrics (Contact factory for IES file) Polar Candela Distribution 180˚170˚160˚150˚140˚ 570 130˚ 475 380 120˚ 285 110˚ 190 100˚ 95 CD: 0 90˚ 95 80˚ 190 70˚ 285 60˚ 380 475 50˚ 570 VA: 0˚ 10˚ 20˚ 30˚ 40˚ Illuminance at a Distance Center Beam FC 2.0ft 4.0ft 6.0ft 8.0ft 10.0ft 12.0ft Beam Width 138.2 fc 3.0 ft 34.6 fc 6.0 ft 15.4 fc 9.0 ft 8.6 fc 12.0 ft 5.5 fc 15.0 ft 3.8 fc 18.0 ft Beam Spread: 73.6˚ CYL6 -14 - LED Polar Candela Distribution 180˚170˚160˚150˚140˚ 570 130˚ 475 380 120˚ 285 110˚ 190 100˚ 95 CD: 0 90˚ 95 80˚ 190 70˚ 285 60˚ 380 475 50˚ 570 VA: 0˚ 10˚ 20˚ 30˚ 40˚ Polar Candela Distribution 180˚170˚160˚150˚140˚ 570 130˚ 475 380 120˚ 285 110˚ 190 100˚ 95 CD: 0 90˚ 95 80˚ 190 70˚ 285 60˚ 380 475 50˚ 570 VA: 0˚ 10˚ 20˚ 30˚ 40˚ Illuminance at a Distance Center Beam FC 2.0ft 4.0ft 6.0ft 8.0ft 10.0ft 12.0ft Beam Width 244.2 fc 3.0 ft 61.0 fc 6.1 ft 27.1 fc 9.1 ft 15.3 fc 12.2 ft 9.8 fc 15.2 ft 6.8 fc 18.2 ft Beam Spread: 74.5˚ CYL6 - 26 - LED Illuminance at a Distance Center Beam FC 2.0ft 4.0ft 6.0ft 8.0ft 10.0ft 12.0ft Beam Width 316.1 fc 2.4 ft 79.0 fc 4.9 ft 35.1 fc 7.3 ft 19.8 fc 9.8 ft 12.6 fc 12.2 ft 8.8 fc 14.7 ft Beam Spread: 63˚ CYL6 - 34 - LED Project Name Fixture Type w w w. l s i - i n d u s t r i e s . c o m Cat# 8/3/17 © LSI INDUSTRIES INC.