Preview only show first 10 pages with watermark. For full document please download

71ff - D. Honoré Construction, Inc.

   EMBED


Share

Transcript

TI 1 I 2 I 3 I 4 I 5 6 pi architects 3500 Jefferson St Austin TX El IE -7F- FF- -7rF- -71FF- GENERAL NOTES 1 CAMERA WEIGHT 5 LBS 2 CAT 5E CABLE W/ MIN 6-0 SERVICE LOOP TERMINATED TO A MALE RJ45 CONNECTOR WITH SERVICE LOOP ATTACHED TO CEILING GRID WIRE -71 Suite 303 78731 P F (512) 231-1910 (512)231-1950 www piarch corn NOTES TO DETAIL Q ATTACH TO WALL PER MANUFACTURERS REQUIREMENTS USING STAINLESS STEEL HARDWARE FOR MASONRY APPLICATIONS architecture .+ master - ecture interior archiElRdscape OGUILOs' SOI OAbLA 2800 North Dallas Parkway Suite 350 Plano TX 75093 Office (469) 568-0300 Website www guidepostsolutions corn INTERIOR CEILING - BRICK WALL MAINTAIN FIRE RATING OF WALL ASSEMBLY p 4SQ 2-1/8 DEEP WITH 2 GANG COVER ELECTRICAL BOX ATTACH TO BUILDING STRUCTURE GRID WIRE WITHJ-HOOK SUPPORT - CADDY CABLE HANGER I CAMERA MOUNT ADAPTER PLATE DI - .CABLE TO SECURITY PANEL LOCATION . - WEIGHT IS 5 2 LBS SERVICE LOOP - 1* 0 SINGLE GANG JUNCTION BOX WITH LABEL MAINTAIN FIRE RATING OF ASSEMBLY -U DOME CAMERA (WEIGHT IS 4 LBS) CEILING .. 8 32 X 375 SCREW .. APPROXIMATE WEIGHT IS 3 LBS MAX 11 AFG 4 SQUARE BOX W/BLANK COVER TOP VIEW SIDE VIEW IC NOT USED K' NTS H NOT USED II NTS ~1 Fi EXTERIOR WALL MOUNT CAMERA - AXIS ill~1 NTS FLUSH CEILING CAMERA MOUNTING DETAIL - AXIS 0 NTS 9dl ~I I~ GENERAL NOTES GENERAL NOTES 1 NETWORK CONNECTION TERMINATED TO RJ45 MALE CONNECTOR AND TERMINATED DIRECTLY TO THE CAMERA 1 CAMERA WEIGHS 2 8 POUNDS 2 SECURE CAMERA TO BACK BOX USING MACHINE SCREWS AND MANUFACTURES ADAPTOR PLATE FOR SURFACE MOUNT INSTALLATIONS 2 NETWORK CONNECTION SHALL TERMINATE DIRECTLY TO CAMERA DO NOT INSTALL PATCH CORD OR DMARC IN THE ACCESSIBLE CEILING CI NOTES TO DETAIL . DECK ABOVE Q Q SECURE GRID WIRE TO CEILING DECK STRUCTURE AND ATTACH TO CAMERA WITH MFGR SUPPLIED SAFETY WIRE CAT-5E CABLE WIMIN 6-0 SERVICE LOOP TERMINATED TO RJ45 ATTACH SERVICE LOOP TO CEILING GRID WIRE III 4S BOX MOUNTED TO DECK ABOVE - PROVIDE A SEISMIC STRAP THAT IS LOOPED THROUGH THE CONDUIT AND SECURE TO ONE OF THE SCREWS ATTACHING THE 4S PLATE TO THE BOX 3/4 CONDUIT TO ACCESSIBLE CEILING CONDUIT TO BOX CONNECTOR CONDUIT TO ACCESS CONTROL PROVIDED BY CABLING CONTRACTOR ISSUE CONDUIT TO BOX CONNECTOR 3/4 CONDUIT I IIS A 4S BOX WITH SINGLE GANG MUD RING 7\1\,-- ':z7 A6 A BI DECK @2016 Pl ARCHITECTS, INC CADDY CABLE HANGER CAMERA .4 I CEILING GRID WIRE CEILING GRID WIRE -0 REVISIONS RATING OF WALL ASSEMBLY 0 , " Ll I b * INTERIOR WALL MAINTAIN FIRE UU- - | ED 4 PM 4 IB QA CONSTRUCTION I E DOCUMENTS AXIS DOME CAMERA 4S BOX MOUNTED TO DECK ABOVE BIM Server S RVOR2015 - BIM Server I17/14017 Concordis Baton Rouge I Ver 18 0011 Monday, Debruary22, 201 SIEGEN LANE BATON ROUGE, LA 70810 -1- WATERSTONE AT BATON ROUGE ASSISTED LIVING & MEMORY CARE ID CONDUIT TO 4 SQUARE BOX ATTACH TO BUILDING STRUCTURE GRID WIRE 4- CAT-5E CABLE SUPPLIED BY CABLING CONTRACTOR 0 MANUFACTURER SUPPLIED SAFETY WIRE -F - OUTER CEILING BRACKET SIDE VIEW - INNER CEILING BRACKET CEILING HOLE 6 1 -6 3 0 - ATTACHING SCREW PER MANUFACTURE INSTRUCTIONS . FLOOR 2 1/2 * PLASTIC DOME COVER CEILING TILE 35 -2 4 THICK MIN 8 2 A F F NOT USED NTS LL- PENDANT MOUNT CAMERA - AXIS EXTERIOR WALL SURFACE MOUNT CAMERA - AXIS NTS NTS @ L11 - PLASTIC DOME SUSPENDED CEILING CAMERA MOUNTING DETAIL - AXIS NTS :II DATE 03/03/2016 IA Al PROJECT NUMBER 14017 SHEET TITLE TELECOM/SECURITY/AV ELECTRONICS DETAILS SHEET I SHEET T4.5 1 I 2 I 3 I 4 I 5 I 6