Preview only show first 10 pages with watermark. For full document please download

7316596 6686509 Web

   EMBED


Share

Transcript

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic’s vision of expanding and pursuing a better life for each of our customers. Working with our many partners, we operate in a wide range of fields such as the home, community, business and travel realising a better world globally through its contribution to the environment and other activies, in both its B2C and B2B businesses. 2 3 For Future Generations Panasonic aims to become the No.1 green innovation company in the electronics industry 4 The 2014 Best Global Green Brands 2014 Brand Ranking Top 10 1 FORD 2 TOYOTA 3 HONDA 4 NISSAN 5 6 NOKIA 7 SONY 8 ADIDAS 9 DANONE 10 DELL Interbrand has announced its 2014 ranking of Best Global Green Brands. In this year’s ranking Panasonic was ranked number five, fulfilling our eco pledge “For future generations, Panasonic aims to become the No.1 Green Innovation Company in the Electronics Industry.” At Panasonic, our eco pledge is more than just a tagline; it’s a harmonious way of life that we take very seriously. Panasonic was founded based on the philosophy of contributing to progress in society and to enriching people’s lives through business activities. By offering products that help people lead better, greener lives, we are making good on our strong commitment to continuous environmental sustainability management. Interbrand’s Best Global Green Brands 2014 report is a look at sustainability with performance data powered by Deloitte and consumer perception data. Interbrand evaluates organisations based on market perception; actual environmental performance; and products and services.* S ource: Best Global Green Brands 2014, Interbrand. Go to www.bestglobalgreenbrands.com for more information. Panasonic Eco City Tianjin, China 5 Panasonic Air Conditioning Designed To Care For Your Projects With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic is unquestionably one of the leaders in the air conditioning sector. The company is also a world leader in innovation as it has filed more than 91,539 patents to improve its customers’ lives. Moreover, Panasonic is determined to remain at the forefront of its market. In all, the company has produced more than 200 million compressors and its products, particularly residential air conditioners, now hold the No. 1 market share in Japan and other major countries in Asia. You can be assured of the extremely high quality of Panasonic’s air conditioners. This wish to excel has made Panasonic the international leader in air conditioning solutions. The company’s industrial capacity and firm commitment to the environment has enabled it to open new avenues of research and to develop innovative technologies which enhance its customers’ way of life. Panasonic offers a range of turnkey air conditioning solutions for homes, medium-sized buildings such as offices and restaurants. These offer maximum effectiveness, comply with the strictest environmental standards and meet the most avant-garde construction requirements of our time. At Panasonic we know what a great responsibility it is to install cooling and heating systems. Because offering you the best solutions in cooling and heating matters. EVERY BUILDING MATTERS WHAT’S NEW Exclusive Feature 1 Using sensors and precise control programs, ECONAVI analyses room conditions and adjusts cooling and heating power to reduce wasted electricity. Exclusive Feature 2 Deluxe Wired Remote Controller Features a large LCD and touch keys for easy operation, and multiple energy-saving functions. 6 CONTENTS Introduction 02 - 07 Exclusive Features 08 - 13 Product Range 14 - 15 Outdoor Units 16 - 21 Indoor Units High Static Pressure Ducted type 22 - 27 Mid Static Pressure Ducted type 28 - 31 4-Way Cassette type 32 - 35 Under Ceiling type 36 - 39 Controllers 40 - 47 7 ECONAVI reduces inefficient air conditioning Providing outstanding energy-saving performance, Panasonic's large capacity air conditioners can be connected to ECONAVI to detect when energy is being wasted. ECONAVI senses the presence or absence of people and the level of activity in each area of a room. When unnecessary heating or cooling is detected, indoor units are individually controlled to match room conditions for energy-saving operation. 4-way Cassette Under Ceiling Mid Static Duct ECONAVI Sensor CZ-CENSC1 High Static Duct Applicable to all 4 types of indoor units* *Except 20.0kW Up to 28% verified energy-saving* With the set temperature increased by 2°C during cooling. EXAMPLE 1 In a coffee shop power is reduced to match the number of customers in each area. Gentle cooling in areas of low activity SEATING AREA COUNTER TABLE : : Indoor units (3) Sensors (3) Thorough cooling in areas of high activity ENTRANCE 8 Exclusive Feature 1 Detection of the level of activity enables optimum power saving Sensors are remotely located to maximise the energy-saving effect Presence or absence of people and the level of activity in the room are detected in real time. Set temperature is automatically adjusted to optimise the power consumption. When sensors are built into the indoor unit, pillars, walls, cabinets and other fittings can obstruct the sensors, reducing the area of detection and lowering the energy-saving effect. Panasonic sensors can be located any where in the room which enables the optimum layout for sensors in any location. Case study at coffee shop 1m 3m 5m 7m Wide detection area -60° In the morning Reduced cooling when tthere are fewer people 60° 40° -40° -20° 0° 20° Wide 120˚ 2.5m In the afternoon Detection area Thorough cooling when there is a high level of activity Approx 1m A Automatic Thermo Off depending on conditions at tthe end of the day* *Depending on conditions, the setting can change to Switch Off After 3 Hours, Thermo Off or Temperature Shift. 7m Dead Zone AAt night A sensor is remotely set to maximise the detection area. Installation flexibility ready for indoor unit layout changes. Test method Test conditions *ECONAVI sensor allows energy saving by allowing set temperature to increase by up to 2°C during times when lower levels of human activity or human presence are detected. Tested with a uniform level of human activity and with doors opened and closed a uniform number of times. At each set temperature between 24°C and 28°C, cumulative power consumption over 3 hour period measured and compared. Maximum possible energy saving is 28% based upon the power consumption difference. *Panasonic test room (29m2). Indoor unit: S-100PU1 (Single 4-way Cassette 10kW) Outdoor unit: U-100PE1 (Single DLX 10kW). Cooling operation, set temperature of 24 to 28°C, Hi airflow setting. EXAMPLE 2 In an apartment, power output is adjusted to match the number of people present in each room. WALK-IN CLOSET MASTER A ER BEDROOM BATH BALCONY BEDROOM KITCHEN BALCONY Gentle cooling in areas of low activity ENTRANCE LIVING Thorough cooling in areas of high activity Indoor units (3) : Grilles (3) Sensors (3) : : 9 Deluxe Wired Remote Controller Easy-to-use, with multiple energy saving functions at your fingertips. Actual size 1 Large 3.5" Full-dot LCD with White LED Backlight Characters and icons are clearly displayed for improved visibility. The display is also large enough to provide a wide range of information for easy confirmation of operation conditions. 10 2 Stylish, Easy-to-use Touch Key Design The elegant, flat design features large touch keys in a simple layout enabling easy, intuitive operation. Exclusive Feature 2 Energy consumption display and Log function Energy Consumption Monitoring Display Graphs of daily, weekly and annual power consumption are displayed. A visual representation of power consumption lets you confirm the energy-saving effect and quickly detect energy-wasting operation. This helps to further improve energy saving. Day Week Month Multiple control settings to meet a wide range of air conditioning needs Temperature Auto Return Even if you change the temperature setting, after a set time it automatically returns to the original temperature setting. You can set temperature auto return time in 10-minute intervals within a period of 4 hours. Temperature Setting Range Limitation You can set the upper and lower temperature limits. Doing this helps reduce power consumption due to over cooling or heating. Setting is possible in the Cooling, Heating and Dry modes. Auto Shutoff Air conditioning automatically stops after a set time, so you don’t have to worry about forgetting to switch the unit off. Even if you manually switch the unit back on after it has stopped, it automatically switches off again after the set time. 11 Wide range of controls for extra convenience Individual Louver Control (For 4-way cassette U1 type) One of the 4-directional outlets can be selected and locked to provide efficient air distribution that matches the indoor unit layout. Indoor units can be set individually. Weekly Timer This lets you specify 8 Start/Stop times and temperature presets for each day of the week. Service Contact Address Once you have registered service contact details, they are automatically displayed if a problem with the air conditioner occurs. This helps you quickly deal with the situation. Convenient Controls Operation Lock Operation keys can be locked to prevent users accidentally changing the temperature setting, airflow rate, airflow direction and other settings. Maintenance Function Display of outdoor malfunction data, service contact details, filter cleaning remaining time and other data enables at-aglance verification of maintenance information with the remote controller. Filter Information Filter information is indicated for cleaning after a set time of operation has passed. The number of hours can be adjusted. Repeat OFF Timer Quiet Operation Mode Setting Information Lists There’s a Quiet mode that reduces the outdoor unit’s operating noise. The mode can be switched On/Off and the Start/End times can be set with the remote controller. 12 You can set the unit to switch off after a desired period of time. Information concerning current settings is displayed in the remote controller’s LCD for easy confirmation. Exclusive Feature Hi-Spec Remote2Con- Function List 13 Panasonic provides ideal solutions for large-capacity air conditioning needs. CAPACITY (kW) 6.0kW Ducted S-60PE1R5A High Static Pressure Model Indoor Unit Page 22-25 for 6.0kW-14.0kW Page 26-27 for 20.0kW Ducted ECONAVI ready (Except for 20.0kW) NEW S-60PF1R5A Mid Static Pressure Model Page 28-31 ECONAVI ready S-60PU1R5A 4-Way Cassette * Panel is provided as an option (CZ-KPU21) Page 32-35 ECONAVI ready S-60PT2R5A Under Ceiling Page 36-39 ECONAVI ready CAPACITY (kW) Outdoor Unit 14 Page16-21 EVERY BUILDING MATTERS 6.0kW U-60PE1R5A NEW 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW S-71PE1R5A S-100PE1R5A S-125PE1R5A S-140PE1R5A S-200PE2R5 S-71PF1R5A S-71PU1R5A NEW S-100PF1R5A S-100PU1R5A NEW S-125PF1R5A NEW S-140PF1R5A S-125PU1R5A S-140PU1R5A NEW S-71PT2R5A S-100PT2R5A S-125PT2R5A S-140PT2R5A 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW U-125PE1R5A U-125PE1R8A* U-140PE1R5A U-140PE1R8A* U-200PE1R8* U-71PE1R5A U-100PE1R5A U-100PE1R8A* NEW NEW (*3-phase) 15 Outdoor Unit DC Inverter allows better comfort and energy savings • Complies with all necessary Safety Approvals to ensure quality and safety • Top-class EER:4.20 / COP:4.31 (4 Way Cassette type:10.0kW) • Demand Response (DRED) compatible • Cooling operation is possible when outdoor temperature as high as 46°C • DC inverter technology combined with R410A for excellent efficiency 16 • Maximum piping length:180m • Cooling operation is possible when outdoor temperature as low as -15°C*1 • Heating operation is possible when outdoor temperature as low as -25°C*2 • One ampere starting current • Auto restart from outdoor unit *1 Except 20.0kW *2 20.0kW only Outdoor Unit Product Quality and Safety All Panasonic air conditioners undergo strict quality and safety tests before sale. This rigorous process includes obtaining all necessary Safety Approvals, to ensure that all air conditioners we sell are not only built to the highest market standards, but are also completely safe. Energy-saving concept The use of energy saving design for the structure of fans, fan motors, compressors and heat exchangers resulted in high COP value which ranked as one the top class in the industry. In addition, use of highly efficient R410A refrigerant reduces CO2 emission and lowers operating costs. 5 4 3 2 Compressor A large inverter compressor has been adopted. The inverter compressor is superior in performance with improved partial-load capacity. Printed Circuit Board (S-LINK) The number of PCB was reduced from 3 into 2* pieces to improve maintenance work. Compact & 1 High Efficient 2 3 DC Fan Motor Checking load and outside temperature, the DC motor is controlled for optimum air volume. New Large 4 Diagonal (520mm) Air Flow Fan The newly designed fan has been developed to inhibit air turbulence and to increase efficiency. As fan diameter has been increased to 520mm*, the air volume has been increased whilst maintaining a low sound level. High-Efficiency Heat Exchanger The heat exchanger and the size of the copper tube in the heat exchanger has been redesigned to increase efficiency. 1 5 *Except for 20.0kW 17 Outdoor Unit Improved Energy Saving The operation efficiency has been improved using highly efficient R410A refrigerant, new DC inverter compressor, new DC motor and new design of heat exchanger. Cooling (Ducted) Heating (Ducted) Cooling 4.4 4.4 Previous 4.3 PE1 PF1 PE2 4.2 4.10 4.1 4.0 PE1 PF1 3.84 4.02 3.8 3.8 3.7 3.7 3.6 3.6 3.50 3.4 3.5 3.36 3.3 3.24 3.23 3.31 3.26 3.25 3.21 3.2 3.01 3.87 3.9 3.5 3.15 3.60 3.41 3.41 3.42 3.48 3.45 3.52 3.52 3.32 3.3 3.68 3.37 3.34 3.1 3.01 3.01 3.4 3.85 3.2 3.0 2.9 2.9 2.77 2.8 2.8 2.7 2.7 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 20.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW Wide Operating Range • Cooling operation is possible when outdoor temperature as low as -15°C*1 • Cooling operation is possible when outdoor temperature as high as 46°C • Heating operation is possible when outdoor temperature as low as -25°C*2 The remote controller temperature setting offers a range from 16°C to 30°C. *1 Except 20.0kW *2 20.0kW only Cooling: -15°C DB to 46°C DB Heating: -20°C WB to 24°C WB Except 20.0kW Cooling: -10°C DB to 46°C DB Heating: -25°C WB to 15°C WB For 20.0kW Increased Piping Length for Greater Design Flexibility Adaptable to various building types and sizes Max. piping length : 50m (6.0kW, 7.1kW), 75m (10.0kW, 12.5kW, 14.0kW), 180m (20.0kW) 18 PE2 4.0 3.90 3.9 3.0 Previous 4.2 4.1 3.1 4.31 4.3 20.0kW Outdoor Unit Demand Response Compliant Panasonic air conditioners are equipped with a Demand Response Enabling Device (DRED) which complies to both AS 4755 and AS 3823. Panasonic continues to design and develop products that are tailored to local needs and requirements. This ensures that Panasonic products that you are installing today are compliant with the demand response standards that are likely to be implemented shortly. The Equipment Energy Efficiency (E3) program has been supporting the development of Demand Response Enabling Device (DRED) standards for airconditioners which should comply with AS 4755. DRED functionality is not compulsory today, however, this capability will be required for all installations in the very near future DRM1 DRM2 DRM3 C Demand controller Terminal block Outdoor unit Demand control terminal is available to control 0-50-75-100% of capacities. Compact and Lightweight The weight is only 98 kg. (10.0kW, 12.5kW, 14.0kW) Hence it is easy to carry, easy to install. Lightweight 98 kg Compact & Flexible-design The slim and lightweight design can be installed in various places. * 14.0kW or smaller capacity unit Single Split FS Multi Quiet Mode Quiet mode reduces outdoor operating sound by 5dB. External input signal is also available. * 14.0kW or smaller capacity unit 19 Outdoor Unit Dimensions (6.0kW – 7.1kW) Space for piping, wiring and maintenance Unit:mm 150 500 or more 2-U shaped hole 200 or more Air intake 300 380.5 Air discharge 13 61 57.5 Enlarged view A Refrigerant piping end connection 75.5 2-18x13 Anchor hole 5 41 8 7 51 340 47 6 35 1 40 940 31.5 Air intake 18 41 340 A Anchor hole Space for piping,wiring and maintenance 76 620 100 or more 170 2 Air intake Air discharge 996 3 120 16 68.5 Hole (Bottom) 173 62 4 42 5 64 90 6 7 8 4 26 39 1) 2) 3) 4) 5) 6) 7) 8) 8 B 81 48 462 120 81 5 60 35 86 60 84.5 109.5 unit: mm View B 7 48 Handle 120 430 39 6 4 35 Mounting hole, anchor bolt:M10 Refrigerant piping (liquid pipe),flared connection (ø9.52) Refrigerant piping (gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35) Dimensions (10.0kW – 14.0kW) Anchor hole Air discharge 340 5 1416 4 3 8 4 26 7 39 48 120 81 60 84.5 109.5 35 4 42 64 View B unit: mm 7 8 48 60 35 86 522 490 120 39 81 20 7 8 90 Air intake Air discharge 6 6 47 6 51 16 40 68.5 5 5 57.5 Enlarged view A 35 75.5 41 Hole (Bottom) 2 61 Refrigerant piping end connection 2-18x13 Anchor hole Handle 76 31.5 Air intake 62 Space for piping, wiring and maintenance Space for piping,wiring and maintenance 173 13 Air intake 120 1 200 or more 18 41 340 A 940 500 or more 2-U shaped hole 300 150 100 or more 620 380.5 170 B 1) 2) 3) 4) 5) 6) 7) 8) Mounting hole, anchor bolt:M10 Refrigerant piping(liquid pipe),flared connection (ø9.52) Refrigerant piping(gas pipe),flared connection (ø15.88) Refrigerant piping hole Electrical wiring port (ø13) Electrical wiring port (ø22) Electrical wiring port (ø27) Electrical wiring port (ø35) Outdoor Unit Dimensions (20.0kW) Air intake Air intake 3 740 (Installation hole pitch) 770 e hol e out hol t -ou ck knoc 0k ø6 18 15 E A Air intake no 8k ø2 Top view (104) 11 12 unit: mm 5 C 930 B 7 View Z D Electrical component box Air discharge 10 9 1758 1654 8 Z 363 15 930 Enlarged view D 601 71 71 628 Installation fixing bracket Installation side 477 326 191 Side view 5 4 33 23 5 2 63 (part 197 1 2 ) Front view According to the installation site, you may choose the setting position in the depth direction of the anchor bolt from "A", "B" or "C". A : 894 (Installation hole pitch) * The tubing is routed out from the front. B : 730 (Installation hole pitch) * The tubing is routed out from the bottom. C : 730 (Installation hole pitch) 77 1 2 Enlarged view E Position of refrigerant tube connection 6 4 2 1 Space for creation of hole on-site (Max. diameter ø48) 92 74 278 347 152 137 66 56 220 355 458 585 646 222 Types of unit Refrigerant tubing (gas tube) Refrigerant tubing (liquid tube) 20.0kW brazed connection flared connection ø19.05 ø9.52 3 Installation holes(8-15x21 elongated holes), anchor bolts M12 or larger 4 Refrigerant tubing port (front: knock-out hole) 5 Refrigerant tubing port (bottom: slit hole) 6 Electrical wiring port (front: ø60, ø28 knock-out hole - for conduit connection) Electrical wiring port (bottom: ø60, ø28 knock-out hole - for conduit connection) Pressure outlet port (for high pressure: ø7.94 Schrader-type connection) Pressure outlet port (for low pressure: ø7.94 Schrader-type connection) 7 Refrigerant tubing & electrical wiring port (Bottom plate dimension) 18 182 856 835 853 Installation hole 8 - 15 x 21 elongated hole 8 9 10 Knock-out hole for connecting pressure gauge (optional) 11 Terminal plate 12 Terminal plate for inter-unit control wiring 21 Indoor Unit High Static Pressure Ducted High static and large airflow ducted for exceptional installation flexibility. ECONAVI ready S-60PE1R5A S-71PE1R5A S-100PE1R5A S-125PE1R5A S-140PE1R5A Compact Body Size Hidden in the ceiling, ideal when interior decor is an important consideration such as in residences with many rooms and light commercial buildings. 1,100 mm 1,100 700 mm mm 700 mm 430 mm 290 mm (60PE) 360 mm (71PE, 100PE) 60PE, 71PE, 100PE 125PE, 140PE System Example An inspection port (450 mm x 450 mm or more) is required at the control-box side of the indoor unit body. Rectangle duct Inspection port (450 x 450 mm or more) 22 Canvas duct Intake grille High Static Pressure Ducted ECONAVI ready CZ-CENSC1 CZ-RTC3 NEW CZ-RTC4 Cold Drafts Reduced During Heating Operation • Accurate temperature measurement by E1/E2 sensor to reduce cold drafts during heating operation. Air intake sensor E2 sensor E1 sensor 23 Indoor Unit High Static Pressure Ducted Dimensions Dimensions: mm Capacity Model Name model A B C D S-60PE1R5A 130 33.1 290 118 S-71PE1R5A S-100PE1R5A 195 35.7 360 50 S-125PE1R5A S-140PE1R5A 260 38.2 430 121.5 6.0kW 7.1kW Indoor Unit S-60PE1R5A S-71PE1R5A S-100PE1R5A S-100PE1R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A 3 Phase/ 50Hz Power source Cooling capacity : Heating capacity 10.0kW Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V kW 6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0) 7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) BTU/h 20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300) 24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 38,200 (14,000 - 47,800) W/W 3.24 : 3.41 3.23 : 3.48 3.36 : 3.52 3.36 : 3.52 Cooling : Heating kW 1.85 : 2.05 2.20 : 2.30 2.98 : 3.18 2.98 : 3.18 Current Cooling : Heating A 0.85 : 0.85 | 0.86 : 0.86 1.24 : 1.24 | 1.25 : 1.25 1.72 : 1.72 | 1.74 : 1.74 1.72 : 1.72 | 1.74 : 1.74 Dimensions H×W×D mm 290×1,100 (+100)×700 360×1,100 (+100)×700 360×1,100 (+100)×700 360×1,100 (+100)×700 kg 35 42 44 44 L/s 366 : 366 500 : 500 666 : 666 666 : 666 Pa 70 (Max.100) 100 (Max.150) 100 (Max.150) 100 (Max.150) EER : COP Total power input Indoor Unit Net weight Air volume Cooling : Heating External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 43 / 41 / 40 : 43 / 41 / 40 45 / 44 / 43 : 45 / 43 / 44 48 / 46 / 44 : 48 / 46 / 44 48 / 46 / 44 : 48 / 46 / 44 Sound power level (H/M/L) Cooling : Heating dB(A) 60 / 58 / 57 : 60 / 58 / 57 62 / 61 / 60 : 62 / 61 / 60 70 / 68 / 66 : 70 / 68 / 66 70 / 68 / 66 : 70 / 68 / 66 Number of fan speed Drain pipe size 3 3 3 3 mm VP-25 VP-25 VP-25 VP-25 Outdoor Unit Current Cooling : Heating A 7.85 : 8.80 | 7.65 : 8.60 9.10 : 9.30 | 8.80 : 9.00 11.8 : 12.7 | 11.40 : 12.3 3.95 : 4.25 | 3.80 : 4.10 Dimensions H×W×D mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 Net weight 24 kg 68 69 98 Air volume Cooling : Heating L/s 1,000 : 1,000 1,000 : 1,000 1,833 : 1,583 1,833 : 1,583 Sound pressure level (Silent mode) Cooling : Heating dB(A) 48 (46) : 50 (48) 48 (46) : 50 (48) 52 (50) : 52 (50) 52 (50) : 52 (50) Sound power level (Silent mode) Cooling : Heating dB(A) 65 (63) : 67 (65) 65 (63) : 67 (65) 69 (67) : 69 (67) 69 (67) : 69 (67) Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m 5 - 50 5 - 50 5 - 75 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Cooling : Heating High Static Pressure Ducted Optional Controller 2.Gas side (O.D.ø15.88 FLARE) ECONAVI sensor CZ-CENSC1 3.Drain pipe size (O.D.ø32) NEW Deluxe Wired remote controller CZ-RTC3 1.Liquid side (O.D.ø9.52 FLARE) Timer remote controller CZ-RTC4 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSK2 + CZ-RWSC3 12.5kW 14.0kW S-125PE1R5A S-125PE1R5A S-140PE1R5A S-140PE1R5A U-125PE1R5A U-125PE1R8A U-140PE1R5A U-140PE1R8A 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 230V | 240V 400V | 415V 230V | 240V 400V | 415V 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 3.21 : 3.37 3.21 : 3.37 3.15 : 3.52 3.15 : 3.52 3.90 : 4.16 3.90 : 4.16 4.45 : 4.55 4.45 : 4.55 1.82 : 1.82 | 1.84 : 1.84 1.82 : 1.82 | 1.84 : 1.84 2.62 : 2.62 | 2.70 : 2.70 2.62 : 2.62 | 2.70 : 2.70 430×1,100 (+100)×700 430×1,100 (+100)×700 430×1,100 (+100)×700 430×1,100 (+100)×700 48 48 53 53 833 : 833 833 : 833 1,000 : 1,000 1,000 : 1,000 100 (Max.150) 100 (Max.150) 100 (Max.150) 100 (Max.150) 49 / 47 / 45 : 49 / 47 / 45 49 / 47 / 45 : 49 / 47 / 45 51 / 49 / 47 : 51 / 49 / 47 51 / 49 / 47 : 51 / 49 / 47 71 / 69 / 67 : 71 / 69 / 67 71 / 69 / 67 : 71 / 69 / 67 73 / 71 / 69 : 73 / 71 / 69 73 / 71 / 69 : 73 / 71 / 69 3 3 3 3 VP-25 VP-25 VP-25 VP-25 16.0 : 17.2 | 15.4 : 16.6 5.30 : 5.70 | 5.10 : 5.50 17.8 : 18.1 | 17.2 : 17.5 5.80 : 5.95 | 5.55 : 5.70 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 98 98 98 2,166 : 1,833 2,166 : 1,833 2,250 : 2,000 2,250 : 2,000 53 (51) : 53 (51) 53 (51) : 53 (51) 54 (52) : 55 (53) 54 (52) : 55 (53) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 5 - 75 5 - 75 5 - 75 5 - 75 15, 30 15, 30 15, 30 15, 30 30 30 30 30 R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 25 Indoor Unit High Static Pressure Ducted NEW High static and large airflow ducted for exceptional installation flexibility. DC motor Self-diagnosing Function Automatic Fan Operation Mild dry Automatic Restart Function Technical focus • Discharge air temperature control to reduce cold drafts during heating operation • Configurable air temperature control • Design flexibility thanks to high static pressure and large air volume • DC motor equipped • Low power input 3-step static pressure set up 72Pa You can select between the three Static Pressure modes of 270 Pa / 140 Pa / 72 Pa for extra installation flexibility. Factory Setting 140Pa 270Pa Max. 270 Pa static pressure setting A maximum static pressure setting of a high 270 Pa enables the use of long ducts for installation in a wide range of spaces. Ideal for large-scale offices, restaurants and other facilities. Capacity Model Name 20.0kW U-200PE1R8 Outdoor Unit Phase/Hz Power source V kW Cooling capacity : Heating capacity BTU/h EER : COP Total power input S-200PE2R5 Indoor Unit Cooling : Heating 1 Phase/ 50Hz 230V | 240V 20.0 (7.0 - 21.5) 22.4 (6.0 - 25.0) 68,200 (23,900 - 73,400) 76,400 (20,500 - 85,300) W/W 3.31 : 3.68 kW 6.05 : 6.09 Indoor Unit Current Cooling : Heating A 3.20 : 3.20 | 3.10 : 3.10 Dimensions H×W×D mm 479×1,453×1,205 kg 106 Cooling : Heating L/s 1,200 / 1,050 / 883.33 : 1,200 / 1,050 / 883.33 Pa 72 (Max.270) Net weight Air volume External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 47 / 45 / 42 : 47 / 45 / 42 Sound power level (H/M/L) Cooling : Heating dB(A) 79 / 77 / 74 : 79 / 77 / 74 Phase/Hz 3 Phase/ 50Hz V 400V | 415V Outdoor Unit Power source Current Cooling : Heating A 8.60 : 8.80 | 8.30 : 8.50 Dimensions H×W×D mm 1,758 × 770 × 930 kg 234 Air volume Cooling : Heating L/s 2,450 Piping connections Liquid / Gas mm (inch) Ø9.52 (3/8) / Ø19.05 (3/4)* Pipe length min. - max. m 7.5 - 180 Elevation difference (OU located lower, OU located higher) m 40, 50 Operation ranges ˚C -10 to 46: -25 to 15 Net weight 26 Cooling : Heating * Tubing size is Ø12.70 (1/2) / Ø22.22 (7/8) when the length is over 90m. Please refer to technical documents for more details. High Static Pressure Ducted NEW CZ-RTC4 CZ-RTC3 S-200PE2R5 Sensible cooling 5-10% improved New heat exchanger with φ7mm pipe that increases the heat transfer surface to improve sensible cooling (5-10% improvement) Discharge air temperature control Air intake sensor E3 sensor • Equipped with 4 sensors (Intake/ Discharge) • Able to control discharge air temperature for accurate room temperature control. • Possible to reduce cold drafts during heating operation. E1 sensor Air discharge sensor HIGH STATIC DUCTED Dimensions 4 1 Refrigerant piping (liquid pipes) Ø9.52 2 Refrigerant piping (gas pipes) 76 type: Ø19.05, 96 type: Ø22.22 3 Power supply outlet (Ø25 grommet, rubber) 4 Power supply outlet (spare) (Ø30 knock-out) 5 Optional outlet for piping 6 Drain port 25 A, male thread 7 Duct connection for suction 8 Duct connection for discharge 27 264 467 479 65 5 3 800 or more (service space) 40 50 77 132 45 600 or more (service space) 1310 1070 10×10 pitch=1000 7 60 479 300 100 100 156 467 6 45 207 43 23 131 1 28- 3.2 holes 600 67 9×100 pitch=900 964 1200 (suspension bolt pitch) 67 Inspection port 1138 (suspension bolt pitch) 1100 1170 Inspection port 60 Approx.200 41 8 422 600 26- 3.2 holes (entire circumference) 1310 610 or more (service space) 100 100 60 320 434 4-37×12 holes (for suspension bolts) 1100 or more (service space) 1220 1205 2 Ceiling Surface 1334 1453 27 Indoor Unit Mid Static Pressure Ducted NEW Provides exceptional performance, super quiet operation and the ultimate in control. A perfect solution when ceiling heights are restricted. ECONAVI ready DC motor Self-diagnosing Function Automatic Fan Operation Mild dry Automatic Restart Function Built-in Drain Pump Technical focus • Space saving 290mm height • DC fan motor for variable external static pressure control • Easy to install and maintain • Air off sensor avoids cold air drafts during heating operation • Configurable air temperature control Variable external static pressure control Optimal airflow set-up is possible for different ducting design and conditions. Optimal Control by DC Motor For short ducting such as hotels 10Pa 150Pa For long ducting or for usage with high density filter * Please refer to technical databook for detail. System example Canvas duct Rectangle duct An inspection port (450 mm x 450 mm or larger) is required at the lower side of the indoor unit body. Intake grille Inspection port (450 x 450 mm or more) More powerful drain pump Using a high-lift built-in drain pump, drain piping can be elevated up to 702 mm from the base of the unit. Up to 300 mm Up to 500 mm 202 mm 28 Mid Static Pressure Ducted ECONAVI ready NEW S-60PF1R5A S-71PF1R5A CZ-CENSC1 CZ-RTC3 CZ-RTC4 S-100PF1R5A S-125PF1R5A S-140PF1R5A Built-in Drain pump (DC motor pump) External electrical equipment box makes maintenance easy Space saving height of 290mm for all models 290mm standardised height provides easy and uniform installation for models with different capacities, especially when ceiling heights are restricted. • Built-in filter • Side removable filter Discharge air temperature control • Possible to control discharge air temperature for accurate room temperature control. • Possible to reduce cold drafts during heating operation. *Before spec-in, please consult with an authorised Panasonic dealer. Air intake sensor E2 sensor E1 sensor V-shaped heat exchanger To improve heat exchange efficiency, an original V-shaped heat exchanger was developed incorporating a conventional high-efficiency fan and high-efficiency grooved heat transfer tubes. This increases the heat exchange surface area by about 80%. Increases surface area by about 30 to 80% 29 Indoor Unit Mid Static Pressure Ducted MID STATIC DUCTED Dimensions SIZE 60, 71 PF1R5A Filter 6 32 28 35 9 280 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 flexible hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug (4-12 × 30 mm) 172 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for flexible air outlet duct 9 Electrical component box 26 4 700 636 700 758 3 7 150 x 5 = 750 21 54 792(Flange O.D.) 154 300 113 65 27 186 23 2 290 Dimensions: mm 186 77 Refrigerant tubing Min.650 6.0KW 7.1KW 10.0KW Indoor Unit S-60PF1R5A S-71PF1R5A S-100PF1R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz V 230V | 240V 230V | 240V 230V | 240V kW 6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0) 7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) BTU/h 20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300) 24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) W/W 3.90 : 3.87 3.84 : 3.85 4.10 : 4.31 kW 1.54 : 1.81 1.85 : 2.08 2.44 : 2.60 Power source Cooling capacity : Heating capacity EER : COP Total power input 140 (75) Electrical component box Capacity Model Name 70 23 27 Min.250 33 (150) Inspection access 450 × 450 Indoor unit Min.400 636 min.250 21 1000 1067(Suspension bolt pitch) 5 130 150 30 20 16-ø3holes 8 1 32 30 256 89 Cooling : Heating Indoor Unit Current Cooling : Heating A 0.89 : 0.89 | 0.87 : 0.87 0.89 : 0.89 | 0.87 : 0.87 1.30 : 1.34 | 1.27 : 1.29 Dimensions H×W×D mm 290×1,000×700 290×1,000×700 290×1,400×700 kg 33 33 45 Cooling : Heating L/s 350 : 350 350 : 350 533 : 533 Pa 70 (10 - 150) 70 (10 - 150) 100 (10 - 150) Net weight Air volume External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 35 / 32 / 26 : 35 / 32 / 26 35 / 32 / 26 : 35 / 32 / 26 38 / 34 / 31 : 38 / 34 / 31 Sound power level (H/M/L) Cooling : Heating dB(A) 58 / 55 / 49 : 58 / 55 / 49 58 / 55 / 49 : 58 / 55 / 49 61 / 57 / 54 : 61 / 57 / 54 mm VP-25 VP-25 VP-25 Drain piping Outdoor Unit Current Cooling : Heating A 7.40 : 7.10 | 8.40 : 8.10 8.60 : 9.50 | 8.30 : 9.20 10.60 : 11.20 | 10.30 : 10.70 Dimensions H×W×D mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 kg 68 69 98 Net weight 30 Air volume Cooling : Heating L/s 1,000 : 1,000 1,000 : 1,000 1,833 : 1,583 Sound pressure level Cooling : Heating dB(A) 48 : 50 48 : 50 52 : 52 Sound power level Cooling : Heating dB(A) 65 : 67 65 : 67 69 : 69 Piping connections Liquid / Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m 5 - 50 5 - 50 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Cooling : Heating Mid Static Pressure Ducted SIZE 100,125,140 PF1R5A Filter 6 28 172 35 32 1 Refrigerant piping joint (liquid tube) Ø9.52 Flare 2 Refrigerant piping joint (gas tube) Ø15.88 Flare 3 Upper drain port VP25 (O.D. Ø32 mm) 200 flexible hose supplied 4 Bottom drain port VP25 (O.D. Ø32 mm) 5 Suspension lug (4-12 × 30 mm) 6 Power supply outlet 7 Fresh air intake port (Ø150 mm) 8 Flange for flexible air outlet duct 9 Electrical component box 280 9 26 4 700 636 700 758 7 3 8 20-ø3holes 150 x 7 = 1050 1192(Flange O.D.) (75) 140 186 290 23 300 2 Dimensions: mm 154 27 Electrical component box 113 65 130 70 23 27 186 Min.250 54 33 (150) 77 Inspection access 450 × 450 Indoor unit Min.400 636 71 1400 1467(Suspension bolt pitch) 5 min.250 150 30 20 71 1 32 30 256 89 Refrigerant tubing Min.650 12.5KW 14.0KW S-100PF1R5A S-125PF1R5A S-125PF1R5A S-140PF1R5A S-140PF1R5A U-100PE1R8A U-125PE1R5A U-125PE1R5A U-140PE1R5A U-140PE1R8A 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 1 Phase/ 50Hz 3 Phase/ 50Hz 400V | 415V 230V | 240V 400V | 415V 230V | 240V 400V | 415V 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 4.10 : 4.31 3.50 : 4.02 3.50 : 4.02 3.25 : 3.60 3.25 : 3.60 2.44 : 2.60 3.57 : 3.48 3.57 : 3.48 4.31 : 4.44 4.31 : 4.44 1.30 : 1.34 | 1.27 : 1.29 1.44 : 1.42 | 1.39 : 1.38 1.44 : 1.42 | 1.39 : 1.38 1.50 :1.50 | 1.47 : 1.46 1.50 :1.50 | 1.47 : 1.46 290×1,400×700 290×1,400×700 290×1,400×700 290×1,400×700 290×1,400×700 45 45 45 45 45 533 : 533 566 : 566 566 : 566 600 : 600 600 : 600 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 100 (10 - 150) 38 / 34 / 31 : 38 / 34 / 31 39 / 35 / 32 : 39 / 35 / 32 39 / 35 / 32 : 39 / 35 / 32 40 / 36 / 33 : 40 / 36 / 33 40 / 36 / 33 : 40 / 36 / 33 61 / 57 / 54 : 61 / 57 / 54 62 / 58 / 55 : 62 / 58 / 55 62 / 58 / 55 : 62 / 58 / 55 63 / 59 / 56 : 63 / 59 / 56 63 / 59 / 56 : 63 / 59 / 56 VP-25 VP-25 VP-25 VP-25 VP-25 3.53 : 3.70 | 3.43 : 3.58 15.90 : 15.80 | 15.30 : 15.10 5.29 : 5.26 | 5.12 : 5.05 19.30 : 19.10 | 18.60 : 18.40 6.42 : 6.35 | 8.18 : 6.15 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 98 98 98 98 1,833 : 1,583 2,166 : 1,833 2,166 : 1,833 2,250 : 2,000 2,250 : 2,000 52 : 52 53 : 53 53 : 53 54 : 55 54 : 55 69 : 69 70 : 70 70 : 70 71 : 71 71 : 71 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 5 - 75 5 - 75 5 - 75 5 - 75 5 - 75 15, 30 15, 30 15, 30 15, 30 15, 30 30 30 30 30 30 R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 31 Indoor Unit 4-WAY Cassette Provides a neat fit in the ceiling to match modern decor, and uniform cooling throughout the room, plus easy installation. Self-diagnosing Function Automatic Fan Operation Mild dry Intelligent Auto Swing Automatic Restart Function Auto Swing (Auto Flap Control) ECONAVI ready Built-in Drain Pump Technical focus • Compact design • Low sound levels • DC fan motor for increased efficiency • Powerful drain pump gives 850 mm lift • Lightweight design • Fresh air knockout • Branch duct connection • Optional air-intake plenum CZ-FDU2 Wide & Comfortable Airflow A proprietary design features wide-angle discharge outlets and flaps that are larger in the middle, featuring a shape that was selected based on numerical mechanics and testing of actual prototype units. Air coming out of the centre of the discharge outlets travels farther. From the sides of each outlet, where the openings are larger, airflow spreads out to reach the corners of the room. Air is discharged across a wide area from the four sides of the unit. The curves on the room temperature distribution graph expand gently out through 360° in a circle centred on the indoor unit. Temperature distribution by thermograph (cooling operation) Comfort/Quiet Ample airflow: 36 m3/min Industry’s leading in the 140PU class. 360° Wide 1m Simulation conditions: P140 4-way ceiling-mounted cassette type in cooling mode / Floor area of 225 m2 / Ceiling height of 3 m 32 Indoor Unit / 4-Way Cassette AIR INTAKE CHAMBER PANEL (CZ-KPU21) 1 2 1 Air intake box CZ-BCU2 for main unit. 2 Air intake box CZ-ATU2* for Air intake plenum. ECONAVI ready NEW * When using Air intake box (CZ-ATU2), Air intake plenum (CZ-FDU2) required. CZ-CENSC1 CZ-RTC3 CZ-RTC4 High-Ceiling Installation (Up to 5 m for 10.0kW+ models) The units can be installed in rooms with high ceilings, where they provide ample floor-level heating in the winter. (See ceiling height guidelines below.) High Ceiling (Factory settings) 3.6m 3.0m New model Capacity 60PU, 71PU 100PU, 125PU, 140PU Industry’s top-class Capacity 5m 4.7m 4.5m 100PU-140PU 4-way discharge high ceiling settings2 3-way discharge 2-way discharge with the optional air-blocking materials with the optional air-blocking materials Ceiling height guidelines *1 settings 4-way discharge 3-way discharge (optional 2-way discharge (optional Factory settings 1 High ceiling setting 1 High ceiling setting 2 60PU-71PU 3.0 3.3 3.6 3.8 4.2 100PU, 125PU, 140PU 3.6 3.9 4.5 4.7 5.0 Indoor unit air-blocking materials) air-blocking materials) *2 *1 When using the unit in a configuration other than the factory settings, it is necessary to make settings on site to increase airflow. *2 Use air-blocking materials (CZ-CFU2) to completely block two discharge outlets for 2-way airflow. 33 Indoor Unit 4-way Cassette Easy Maintenance and Cleaning It is easy to remove the washable flaps by hand. The flap can be removed easily for cleaning. Low-Profile 33.5 mm Panel Suction grill able to make 90 degree turns. One of the industry’s thinnest panels The square panel integrates seamlessly with the ceiling. Discharge outlets close when the unit is stopped. Protrusion of 33.5 mm Lighter and Slimmer, Easier Installation A lightweight unit at 24 kg, the unit is also very slim with a height of only 256 mm, making installation possible even in narrow ceilings. * For 6.0kW/7.1kW A Drain Height of Approx. 850 mm from the Ceiling Surface Only 256 mm Up to 300 mm Drain Pump of about 850 mm from the ceiling surface The drain height can be increased by approximately 350 mm over the conventional value by using a high-lift drain pump, and long horizontal piping is possible. Capacity Model Name Up to 850 mm 6.0kW 7.1kW Indoor Unit S-60PU1R5A S-71PU1R5A S-100PU1R5A S-100PU1R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 Phase/Hz 1 phase, 50Hz 1 phase, 50Hz 1 phase, 50Hz 3 phase, 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V kW 6.0 (2.5 - 8.0) 7.0 (2.0 - 8.5) 7.1 (2.5 - 8.2) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) BTU/h 20,500 (8,500 - 27,300) 23,900 (6,800 - 29,000) 24,200 (8,500 - 28,000) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) Panel Power source Cooling capacity Heating capacity 10.0kW EER : COP Cooling : Heating W/W 4.05 : 3.87 3.94 : 4.00 4.20 : 4.31 4.20 : 4.31 Total power input Cooling : Heating kW 1.48 : 1.81 1.80 : 2.00 2.38 : 2.60 2.38 : 2.60 Cooling : Heating A 0.31 : 0.30 | 0.30 : 0.29 0.33 : 0.32 | 0.32 : 0.31 0.71 : 0.65 | 0.71 : 0.64 0.71 : 0.65 | 0.71 : 0.64 Indoor mm 256 × 840 × 840 256 × 840 × 840 319 × 840 × 840 319 × 840 × 840 Panel mm 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 Indoor kg 24 24 27 27 Panel kg 4 4 4 4 Air volume Cooling : Heating L/s 350 : 350 366 : 366 550 : 550 550 : 550 Sound pressure level (H/M/L) Cooling : Heating dB(A) 36 / 31 / 28 : 36 / 31 / 28 37 / 31 / 28 : 37 / 31 / 28 44 / 38 / 32 : 44 / 38 / 32 44 / 38 / 32 : 44 / 38 / 32 Sound power level (H/M/L) Cooling : Heating dB(A) Indoor Unit Current Dimensions H×W×D Net weight Number of fan speed Drain pipe size 53 / 48 / 45 : 53 / 48 / 45 54 / 48 / 45 : 54 / 48 / 45 62 / 55 / 49 : 62 / 55 / 49 62 / 55 / 49 : 62 / 55 / 49 3 3 3 3 mm VP-25 VP-25 VP-25 VP-25 A 6.90 : 8.20 | 6.70 : 7.95 8.10 : 9.00 | 7.90 : 8.70 10.3 : 11.4 | 9.90 : 11.0 3.50 : 3.85 | 3.40 : 3.75 mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 kg 68 69 98 98 Outdoor Unit Current Dimensions Cooling : Heating H×W×D Net weight Air volume Cooling : Heating L/s 1,000 : 1,000 1,000 : 1,000 1,833 : 1,583 1,833 : 1,583 Sound pressure level (Silent mode) Cooling : Heating dB(A) 48 (46) : 50 (48) 48 (46) : 50 (48) 52 (50) : 52 (50) 52 (50) : 52 (50) Sound power level (Silent mode) Cooling : Heating dB(A) 65 (63) : 67 (65) 65 (63) : 67 (65) 69 (67) : 69 (67) 69 (67) : 69 (67) m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 m 5 - 50 5 - 50 5 - 75 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 Piping connections Pipe length 34 min. - max. Cooling : Heating Indoor Unit / 4-Way Cassette 345 5 3 50 160 160 9 7 2 18 118 2 950 30 2 515 le 4 -ø3 Burring ho 82 42 121 33.5 6 950 514 Less than 670 115 Air discharge duct connection hole (ø150) 1 80 13 ø1 X view A 271 160 95 7 Less than 300 Less than 850 ø3 hole 4 Burring 115 62 ø1 480 7 4 50 145 180 B 2 Less than 35 7 100PU-140PU 319 187 840 167 Less than 35 60PU-71PU 256 124 B (411) 8 745 (Suspension bolt pitch) 860~910 (Ceiling opening dimension) 786 (Suspension bolt pitch) *1: Air inlet kit is necessary. Filter size: 520 x 520 x 16 840 480 A B 167 130 95 X 860~910 (Ceiling opening dimension) Air intake grill Air discharge outlet Refrigerant piping (liquid pipes) : ø9.52 (flared) Refrigerant piping (gas pipes) : ø15.88 (flared) Drain outlet VP25(outer ø32) Power supply port Discharge duct (ø150) Suspension bolt hole (4-12x30 slot) Fresh air intake duct connection port (ø100)*1 421 1 2 3 4 5 6 7 8 9 130 Dimensions Dimensions: mm 80 Drain up Air intake duct connection hole (ø100) 2 * Adjust the suspension bolt length so that the gap from the lower ceiling surface becomes 30 mm or more (18 mm or more from the lower surface of the body) as shown in the figure. When the suspension bolt length is long, it hits the ceiling panel and installation is not possible. 12.5kW 14.0kW S-125PU1R5A S-125PU1R5 A S-140PU1R5A S-140PU1R5A U-125PE1R5A U-125PE1R8A U-140PE1R5A U-140PE1R8A CZ-KPU21 CZ-KPU21 CZ-KPU21 CZ-KPU21 1 phase, 50Hz 3 phase, 50Hz 1 phase, 50Hz 3 phase, 50Hz 230V | 240V 400V | 415V 230V | 240V 400V | 415V 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.5) 16.0 (4.1 - 18.0) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 47,800 (11,300 - 52,900) 54,600 (14,000 - 61,400) 3.60 : 4.00 3.60 : 4.00 3.25 : 3.70 3.25 : 3.70 3.47 : 3.50 3.47 : 3.50 4.31 : 4.33 4.31 : 4.33 0.76 : 0.73 | 0.73 : 0.73 0.76 : 0.73 | 0.73 : 0.73 0.89 : 0.80 | 0.87 : 0.79 0.89 : 0.80 | 0.87 : 0.79 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840 319 × 840 × 840 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 33.5 x 950 x 950 27 27 27 27 4 4 4 4 583 : 583 583 : 583 600 : 600 600 : 600 45 / 39 / 33 : 45 / 39 / 33 45 / 39 / 33 : 45 / 39 / 33 46 / 40 / 34 : 46 / 40 / 34 46 / 40 / 34 : 46 / 40 / 34 63 / 56 / 50 : 63 / 56 / 50 63 / 56 / 50 : 63 / 56 / 50 64 / 57 / 51 : 64 / 57 / 51 64 / 57 / 51 : 64 / 57 / 51 3 3 3 3 VP-25 VP-25 VP-25 VP-25 15.3 : 15.4 | 14.8 : 14.9 5.15 : 5.20 | 5.00 : 5.05 19.0 : 19.2 | 18.4 : 18.6 6.45 : 6.50 | 6.20 : 6.25 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 98 98 98 2,166 : 1,833 2,166 : 1,833 2,250 : 2,000 2,250 : 2,000 53 (51) : 53 (51) 53 (51) : 53 (51) 54 (52) : 55 (53) 54 (52) : 55 (53) 70 (68) : 70 (68) 70 (68) : 70 (68) 71 (69) : 71 (69) 71 (69) : 71 (69) Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 5 - 75 5 - 75 5 - 75 5 - 75 15, 30 15, 30 15, 30 15, 30 30 30 30 30 R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 -15 - 46 : -20 - 24 Optional Controller ECONAVI sensor CZ-CENSC1 NEW Timer remote controller CZ-RTC4 Deluxe Wired remote controller CZ-RTC3 Wireless remote controller CZ-RWSU2N Simplified remote controller CZ-RE2C2 35 Indoor Unit Under Ceiling Providing outstanding energy-saving performance, comfort and long-distance air flow distribution, these units are perfect for retail stores and schools. ECONAVI ready Compact Looking, Stylish, One-Motion Design With its streamlined, one-motion form, the unit looks thin and compact when installed for a neat appearance in any room. When not operating, the louver closes to provide an elegant look while also keeping the unit clean. Energy-Saving Technology Delivering Top-Class Efficiency Top Class Energy Saving Optimisation of the shape of the casing and fan assures bigger air flow and higher efficiency. Energy-saving performance is top class in the industry. New DC fan motor DC motor 36 Large Diagonal Air Flow Fan Fan diameter f 147.5 Indoor Unit / Under Ceiling S-60PT2R5A S-71PT2R5A S-100PT2R5A S-125PT2R5A S-140PT2R5A ECONAVI ready CZ-CENSC1 CZ-RTC3 NEW CZ-RTC4 Comfortable, Long-Distance Air Flow Distribution The shape of the outlet has been optimised to provide long-distance air flow distribution. Even in long rooms, air flow reaches every corner for exceptionally comfortable air conditioning. Ceiling height 4.3m* Air flow distance 13m* * Results are based on specific testing conditions High Ceiling Setting Air flow distance *Setting by remote control 100 125 140 4.3m 12m 13m 13m 37 Indoor Unit Under Ceiling Dimensions 123 61 73 7 Indoor Units: S-60PT2R5A S-71PT2R5A 114 Drain port VP20 (inside diameter ø26mm, drain hose supplied) Left drain position Refrigerant liquid tubing (ø9.52mm, flare connection) Refrigerant gas tubing (ø15.88mm, flare connection) Left side drain hose outlet port (cutout) Tubing hole on wall surface (ø100mm) Upper side tubing port Right side drain hose outlet port (cutout) Wireless remote controller receiver installation location 265 190 (Suspension bolt pitch) 1 2 3 4 5 6 7 8 9 1226 (Suspension bolt pitch) 690 131 193 235 Air discharge Over 250 Over 250 1275 Service space 80 186 Service space Tubing hole position on wall surface (Figure shows view from front) 176 Air intake 216 9 2 90 (Left drain position) (Closed with rubber stopper at time of shipment.) Capacity Model Name 1 8 216 4 5 Minimum 50cm Approx. 2° 15 1269 6 96 86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) 3 4 6.0kW 7.1kW Indoor Unit S-60PT2R5A S-71PT2R5A S-100PT2R5A S-100PT2R5A Outdoor Unit U-60PE1R5A U-71PE1R5A U-100PE1R5A U-100PE1R8A Phase/Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 1 Phase/ 50Hz 3-Phase/ 50Hz V 230V | 240V 230V | 240V 230V | 240V 400V | 415V kW 6.0 (2.5 - 7.1) 7.0 (2.0 - 8.0) 7.1 (2.5 - 8.0) 8.0 (2.0 - 9.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) 10.0 (3.3 - 12.5) 11.2 (4.1 - 14.0) BTU/h 20,500 (8,500 - 24,200) 23,900 (6,800 - 27,300) 24,200 (8,500 - 27,300) 27,300 (6,800 - 30,700) 34,100 (11,300 - 42,700) 34,100 (11,300 - 42,700) 38,200 (14,000 - 47,800) 38,200 (14,000 - 47,800) Power source Cooling capacity : Heating capacity 10.0kW W/W 4.03 : 4.02 3.68 : 4.15 3.95 : 4.31 3.95 : 4.31 Cooling : Heating kW 1.49 : 1.74 1.93 : 1.93 2.53 : 2.60 2.53 : 2.60 Current Cooling : Heating A 0.41 : 0.41 | 0.40 : 0.40 0.44 : 0.44 | 0.43 : 0.43 0.67 : 0.67 | 0.65 : 0.65 0.67 : 0.67 | 0.65 : 0.65 Dimensions H×W×D mm 235×1,275×690 235×1,275×690 235×1,590×690 235×1,590×690 kg 33 33 40 40 L/s 333 : 333 350 : 350 500 : 500 500 : 500 Pa - - - - EER : COP Total power input Indoor Unit Net weight Air volume Cooling : Heating External static pressure Sound pressure level (H/M/L) Cooling : Heating dB(A) 38 / 34 / 30 : 38 / 34 / 30 39 / 35 / 31 : 39 / 35 / 31 42 / 37 / 35 : 42 / 37 / 35 42 / 37 / 35 : 42 / 37 / 35 Sound power level (H/M/L) Cooling : Heating dB(A) 56 / 52 / 48 : 56 / 52 / 48 57 / 53 / 49 : 57 / 53 / 49 60 / 55 / 53 : 60 / 55 / 53 60 / 55 / 53 : 60 / 55 / 53 Number of fan speed Drain pipe size 3 3 3 3 mm VP-20 VP-20 VP-20 VP-20 Outdoor Unit Current Cooling : Heating A 6.90 : 7.80 | 6.70 : 7.60 8.70 : 8.60 | 8.40 : 8.30 11.1 : 11.4 | 10.6 : 11.0 3.75 : 3.85 | 3.65 : 3.75 Dimensions H×W×D mm 996 × 940 × 340 996 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 Net weight 38 kg 68 69 98 Air volume Cooling : Heating L/s 1,000: 1,000 1,000: 1,000 1,833: 1,583 1,833: 1,583 Sound pressure level Cooling : Heating dB(A) 48 : 50 48 : 50 52 : 52 52 : 52 Sound power level Cooling : Heating dB(A) 65 : 67 65 : 67 69 : 69 69 : 69 Piping connections Liquid/Gas m Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Pipe length min. - max. m 5 - 50 5 - 50 5 - 75 5 - 75 Elevation difference (OU located lower, OU located higher) m 15, 30 15, 30 15, 30 15, 30 Maximum chargeless length m 30 30 30 30 Refrigerant at shipping, Additional gas amount g R410A 2,000, 50 (g/m) R410A 2,350, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) Operation ranges ˚C -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Cooling : Heating Indoor Unit / Under Ceiling Indoor Units: S-100PT2R5A S-125PT2R5A S-140PT2R5A 114 265 190 (Suspension bolt pitch) 61 73 123 7 1541 (Suspension bolt pitch) 690 216 1 8 131 193 235 4 Air intake Air discharge Over 250 Over 250 1590 Service space 80 186 Service space Tubing hole position on wall surface (Figure shows view from front) 176 5 Minimum 50cm Approx. 2° 15 1584 216 9 2 90 (Left drain position) (Closed with rubber stopper at time of shipment.) 12.0kW 3 4 14.0kW S-125PT2R5A S-125PT2R5A S-140PT2R5A S-140PT2R5A U-125PE1R5A U-125PE1R8A U-140PE1R5A U-140PE1R8A 1 Phase/ 50Hz 3-Phase/ 50Hz 1 Phase/ 50Hz 3-Phase/ 50Hz 230V | 240V 400V | 415V 230V | 240V 400V | 415V 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 12.5 (3.3 - 14.0) 14.0 (4.1 - 16.0) 14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0) 14.0 (3.3 - 15.0) 16.0 (4.1 - 18.0) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 42,700 (11,300 - 47,800) 47,800 (14,000 - 54,600) 47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400) 47,800 (11,300 - 51,200) 54,600 (14,000 - 61,400) 3.35 : 3.99 3.35 : 3.99 3.01 : 3.67 3.01 : 3.67 3.73 : 3.51 3.73 : 3.51 4.65 : 4.36 4.65 : 4.36 0.86 : 0.86 | 0.83 : 0.83 0.86 : 0.86 | 0.83 : 0.83 0.91 : 0.91 | 0.88 : 0.88 0.91 : 0.91 | 0.88 : 0.88 235×1,590×690 235×1,590×690 235×1,590×690 235×1,590×690 40 40 40 40 566 : 566 566 : 566 583 : 583 583 : 583 - - - - 6 96 86 (Gas tubing) 70 (Liquid tubing) 90 (Right drain position) Optional Controller ECONAVI sensor CZ-CENSC1 NEW Deluxe Wired remote controller CZ-RTC3 46 / 40 / 36 : 46 / 40 / 36 46 / 40 / 36 : 46 / 40 / 36 47 / 41 / 37 : 47 / 41 / 37 47 / 41 / 37 : 47 / 41 / 37 64 / 58 / 54 : 64 / 58 / 54 64 / 58 / 54 : 64 / 58 / 54 65 / 59 / 55 : 65 / 59 / 55 65 / 59 / 55 : 65 / 59 / 55 3 3 3 3 VP-20 VP-20 VP-20 VP-20 16.4 : 15.4 | 15.8 : 14.9 5.55 : 5.20 | 5.35 : 5.05 20.5 : 19.2 | 19.8 : 18.5 6.95 : 6.50 | 6.70 : 6.25 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 1,416 × 940 × 340 98 98 98 98 2,166: 1,833 2,166: 1,833 2,250: 2,000 2,250: 2,000 53 : 53 53 : 53 54 : 55 54 : 55 70 : 70 70 : 70 71 : 71 71 : 71 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 Ø9.52 / Ø15.88 5 - 75 5 - 75 5 - 75 5 - 75 15, 30 15, 30 15, 30 15, 30 30 30 30 30 R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) R410A 3,400, 50 (g/m) -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 -15 to 46 : -20 to 24 Timer remote controller CZ-RTC4 Wireless remote controller CZ-RWST3N Simplified remote controller CZ-RE2C2 39 Controllers A wide variety of control options to meet the requirements of different applications. OPERATION SYSTEM Requirements INDIVIDUAL CONTROL SYSTEMS High-spec operation Normal operation TIMER OPERATION Operation from anywhere Quick and easy operation in the room Daily and weekly program NEW External appearance Deluxe Wired Remote Controller Timer Remote Controller (Wired) Wireless Remote Controller Simplified Remote Controller Schedule Timer CZ-RTC3 CZ-RTC4 CZ-RWSU2N C-RWSK2 + CZ-RWST3N CZ-RWSC3 CZ-RE2C2 CZ-ESWC2 ECONAVI on/off control l l l l l — l — — — Number of indoor units which can be controlled 1 group, 8 units 1 group, 8 units 1 group, 8 units 1 group, 8 units 64 groups, max. 64 units Type, model name Built-in thermostat Use limitations Function ON/OFF Mode setting Fan speed setting Temperature setting Air flow direction Permit/Prohibit switching Weekly program ·U  p to 2 controllers can · Up to 2 controllers can · Up to 2 controllers can be connected per be connected per be connected per group (When using group. (When using group. ECONAVI sensor, only ECONAVI sensor, only one remote controller one remote controller is is possible to connect possible to connect at at indoor unit) indoor unit) l l l l l l l l l l l l — l 1. Setting is not possible when a remote control unit is present. (Use the remote controller for setting.) All specifications subject to change without notice. 40 l l l l l — — · Up to 2 controllers can be connected per group. l l l l l — — · Required power supply from the system controller · When there is no system controller, connection is possible to the T10 terminal of an indoor unit. — — — — — — l Controllers ECONAVI Sensor [CZ-CENSC1] Utilises ECONAVI Sensor and Control Program technologies to detect where energy is normally wasted and selfadjusts cooling power to reduce energy waste. • Activity detection • Absence detection CENTRALISED CONTROL SYSTEMS Operation with various function Only ON/OFF operation from from centre station centre station Simplified load distribution ratio (LDR) for each tenant Touch screen panel BMS System PC Base P-AIMS Basic Software Connection with 3rd Party Controller Seri-Para I/O unit for outdoor unit CZ-CAPDC2 CZ-CSWKC2 System Controller ON/OFF Controller Intelligent Controller CZ-64ESMC2 CZ-ANC2 CZ-256ESMC2 (CZ-CFUNC2) — — — — — — 64 groups, max. 64 units 16 groups, max. 64 units 64 units x 4 links, max. 256 units ·U  p to 10 controllers, can be · Up to 8 controllers (4 main · A communication adaptor connected to one system. units + 4 sub units) (CZ-CFUNC2) must be · Main unit/sub unit (1 main can be connected to one installed for three or more unit + 1 sub unit) connection system. links. is possible. · Use without remote controller · Use without remote controller is impossible. is possible. l l l l l¹ l — l — — — — l — l l l l l¹ l l Interface adaptor Optional software CZ-CAPC2 CZ-CSWAC2 for Load distribution CZ-CSWWC2 for Web application CZ-CSWGC2 for Object layout display CZ-CSWBC2 for BACnet software interface *PC required (field supply) Web Interface Systems Seri-Para I/O unit for each indoor unit CZ-CAPBC2 Communication Adaptor CZ-CFUNC2 LonWorks Interface CZ-CWEBC2 *PC required (field supply) CZ-CLNC2 41 Individual Control Systems Control contents Part name, model No. Quantity Standard Control • Control of the various operations of the indoor unit by wired or wireless remote controller. • Cooling or heating mode of the outdoor unit is decided by the first priority of the remote controller. • Switching between remote controller sensor and body sensor is possible. Timer remote controller CZ-RTC4 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2N / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 1 unit each (1) Group control • Batch remote control on all indoor units. • Operation of all indoor cells in the same mode. • Up to 8 units can be connected. • The sensor is the body sensor, and thermostat ON/OFF setting in regard to the temperature set by the remote controller is possible for each indoor unit. Timer remote controller CZ-RTC4 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2N / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 As required (2) Main/sub remote control • Max 2 remote controllers per indoor unit. (Main remote controller can be connected) • The button pressed last has priority. • Timer setting is possible even with the sub remote controller. When using ECONAVI sensor, only one remote controller is possible to connect at indoor unit. Main or sub Timer remote controller CZ-RTC4 / CZ-RTC3 Simplified remote controller CZ-RE2C2 Wireless remote controller CZ-RWSU2N / CZ-RWST3N / CZ-RWSK2 + CZ-RWSC3 As required SYSTEM EXAMPLE Remote controller Standard control 42 Main Sub (2) Main/sub remote control Main (1) Group control Sub Controllers Deluxe wired remote controller (CZ-RTC3) Basic Operation Dimensions H 120 x W 120 x D 16 mm Energy Saving • ECONAVI on/ off* • Temperature Auto Return • Temperature Setting Range • Auto Shutoff • Schedule peak cut • Repeat off timer • Individual Louver Control (Lock individual flap for 4-way cassette) • ON/ OFF timer • Weekly Timer • Filter information* • Outing function • Quiet operation mode* • Power consumption monitor* • Energy saving* • Initial settings • Ventilation Maintenance Function • Outdoor unit error data • Service Contact address • RC setting mode • Test Run • Sensor Information* • Service check • Simple/ Detailed Settings • Auto address * Subject to the connected model Timer remote controller (CZ-RTC4) NEW Weekly Programme Function • A maximum of 6 settings/day and 42 settings/week can be programmed. Outing Function • This function can prevent the room temperature from dropping or rising when the occupants are out for a long time. Sleeping Function Dimensions H 120 x W 120 x D 20 mm Basic remote controller ON/OFF • Operation mode changeover (Cooling, Heating, Dry, Auto, Fan). • Temperature setting (Cooling/Dry: 18-30 deg Heating: 16-30 deg). • Fan speed setting H/ M/ L and Auto. • Air flow direction adjustment. • ECONAVI on/ off* • This function controls the room temperature for comfortable sleeping. Max. 8 indoor units can be controlled from one remote controller Remote control by main remote controller and sub controller is possible Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. * Depending on the model, some menus cannot be used. Time Function 24 hours real time clock • Day of the week indicator. 43 Wireless remote controller Remote control by main remote controller and sub controller is possible • Max. 2 remote controllers (main remote controller and sub controller) can be installed for one indoor unit. For 4-Way cassette type CZ-RWSU2N When CZ-RWSC3 is used, wireless control becomes possible for all indoor units • When a separate receiver is set up in a different room, control from that room also becomes possible. • Automatic operation by means of the emergency operation button is possible even when the remote controller has been lost or the batteries have been exhausted. In addition, there are other functions such as temperature setting, operation switching, wind direction/fan speed setting, etc For all Ducted types CZ-RWSK2 + CZ-RWSC3 Ventilation independent operation is possible When commercial ventilation fans or heat-exchange ventilation fans have been installed, they can be operated with this remote control (interlocked operation with the indoor unit or independent ventilation ON/OFF). For under ceiling type CZ-RWST3N Simplified remote controller (CZ-RE2C2) A remote controller with simple functions and basic operation • Suitable for open rooms or hotels where detailed functions are not required. • ON/OFF, operation mode switching, temperature setting, wind velocity switching, wind direction setting, alarm display, and remote controller self-diagnosis can be performed. • Batch group control for up to 8 indoor units. • Remote control by main remote controller and sub controller is possible with a simplified remote controller or a wired remote controller (up to two units). Dimensions H 120 x W 70 x D 17 mm 44 Controllers T10 Terminal for External Control (Digital Connection) Connecting an indoor unit to an external device is easy. The T10 Terminal featured in the electronic circuit board of all indoor units enables digital connection to external devices. 1. T10 Terminal Specification (T10:CN061 at indoor unit PCB) 1 • ControlCOM items: 1. Start/stop input 2 3 2. Remote controller prohibit input 4 3. Start signal output +12V COM 5 T10 4. Alarm signal output (yellow) 1 COM 2 3 6 4 300msec. or more T10 (yellow) 1-2 (pulse input) ON OFF COM 5 Condition +12 4-5 (output) Unit condition • Example of wiring ON NOTE: The wire length from indoor unit to the Relay must be within 2.0m. Pulse signal changeable to static with JP cutting. (Refer to JP001) +12V 6 300msec. or more 1. 1-2 (Pulse input): Unit ON/OFF condition switching with a pulse signal. (1 1-2pulse (pulse input) signal: shortage status more than 300msec.or more) 2. 2-3 (Static input): Open/ Operation with Remote is permitted.(Normal condition) Close/ Remote controller is prohibited. +12 the unit ON. / No output at OFF. 3. 4-5 (Static output): 12V output during 4-5 (output) 4. 5-6 (Static output): 12V output when some errors occur / No output at normal. Unit condition ON OFF ON 2. Usage Example Forced OFF control Operation ON/OFF signal output • Condition • Condition 1-2 (Static input): Close/ Operation with Remote is permitted. (Normal condition) Open/ Unit is forcibly OFF and Remote controller operation is prohibited. 4-5 (Static output): 12V output during the unit ON / No output at OFF • Example of wiring • Example of wiring Relay (Field supply) T10 (YEL) Relay (Field supply) T10 (YEL) Indoor unit control PCB Central control The contact in the figure is a state where the card is pulled out. POWER External contact (Card switch box, etc.: field supply) NOTE: The wire length from indoor unit to the Relay must be within 2.0m Indoor unit control PCB 2m NOTE: The wire length from indoor unit to the Relay must be within 2.0m Pulse signal changeable to static with JP cutting. (Refer to JP001) 45 Remote Controller External Dimensions TIMER REMOTE CONTROLLER (CZ-RTC4) DELUXE WIRED REMOTE CONTROLLER (CZ-RTC3) 120 120 167 120 16 24.75 20 120 SEPARATE RECEIVER FOR WIRELESS REMOTE CONTROLLER (CZ-RWSC3) 20 WIRELESS REMOTE CONTROLLER 120 70 Unit: mm SYSTEM CONTROLLER (CZ-64ESMC2) 66.8 17 70 116 10 4.4 16.7 SIMPLIFIED REMOTE CONTROLLER (CZ-RE2C2) 9.4 160 148 (6) 21 69 (6) ECONAVI SENSOR (CZ-CENSC1) 121 REMOTE SENSOR (CZ-CSRC3) 17 70 120 46 115 121 33.4 160 148 5.4 13 4.4 8 33.5 16.6 6 6 116.8 83.5 120 9.4 Controllers COMMUNICATION ADAPTOR (CZ-CFUNC2) 38 80 38 180 256 290 270 INTELLIGENT CONTROLLER (CZ-256ESMC2) 79 R 2.5 8 R5 ø22.2 (mm) (6) (6) 14 69 115 160 148 121 6 SERI-PARA I/O UNIT FOR EACH INDOOR UNIT (CZ-CAPBC2) 116 160 148 6 ON/OFF CONTROLLER (CZ-ANC2) 122 LONWORKS INTERFACE (CZ-CLNC2) SERI-PARA I /O UNIT FOR OUTDOOR UNIT (CZ-CAPDC2) 4 - Ø 5 hole Potbellied hole (4 locations) 3 - Ø 30 hole Magnified view Detail of the potbellied hole 47 EVERY BUILDING MATTERS www.panasonicair.com.au • Specifications are subject to change without prior notice for further improvement • The contents of this catalogue are effective as of June 2015. April, 2012 • Due to printing considerations, the actual colours may vary slightly from those shown • All graphics are provided merely for the purpose of illustrating a point.