SECTION GFCI Personnel Safety Devices Smartlock® GFCI Device Smartlock® GFCI devices comply with 2003 UL requirements. HOSPITAL GRADE 8598-HGR ● Power/Diagnostic Indicator ● 15 & 20Amp Configurations ● Back and Side Wired ● Color Match Test/Reset Buttons (Monochromatic) ● Green LED Indicates Power and Confirms Proper Wiring Status ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements Smartlock® GFCI Device Types COMMERCIAL C-PACK ● 15 Amp Single GFCI Receptacle with Single-Pole Switch ● Switch Rated 8.3 Amps at 120V AC ● Back and Side Wired ● Color Match Test/Reset Buttons (Monochromatic) ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements ● 20 Amp with Switch Rated Test/Reset Buttons ● Back and Side Wired ● Color Match Test/Reset Buttons (Monochromatic) ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements 8299-G PAGE F3 PAGE F3 ● Blank Face ● Contact Rating: 20A 125V ● Control Relay: 80 Amps 240VACMax. ● Side Wired ● Color Match Test/Reset Buttons (Monochromatic) ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements ● Recognized Component 8895-80E ANGLE PLUG Right Angle GFCI Plugs ● 15A 125V; 20A 125V ● Automatic and Manual Reset Types ● Power Staus Indicator ● Available in Gray and Yellow ● Recognized Component 6593 PAGE F4 8599-I COMBO PAGE F3 HIGH CURRENT ●15 & 20 Amp Configurations ● Back and Side Wired ● Color Match Test/Reset Buttons (Monochromatic) ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements ● Available with 41/2” pigtail leads BLANK FACE 8590-W 8599-CPI COMMERCIAL GRADE PAGE F3 ● 15 Amp Configurations ● Back and Side Wired ● Black Reset & Red Test Buttons ● Contractor Pack ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements PAGE F4 1 8598-E ● Power/Diagnostic Indicator ● 15 & 20Amp Configurations ● Back and Side Wired ● Color Match Test/Reset Buttons (Monochromatic) ● Green LED Indicates Power and Confirms Proper Wiring Status ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements PAGE F3 PAGE F3 F COMMERCIAL GRADE PLUS PANEL MOUNT WORK LIGHT Recognized Component 66591-WL 36596 Panel Mount GFCI with16” Leads ● 20A 125V ● Orange LED Indicator Light ● Weather-Resistant Hosing & Test/Reset Buttons ● Resistant to Surge, Noise, and Corrosion Per 2003 UL Requirements PAGE F4 CORD SETS 66591-25C GFCI Cord Sets ● 15A & 20A 125V; 15A & 20A 240V ● Automatic and Manual Reset Types ● Orange Power Staus Indicator ● Yellow Cord 14/3 SJT ● Resistant to Surge, Noise, & Corrosion Per 2003 UL Requirements PAGES F5 & F6 To learn more about Leviton devices or for answers to technical questions call our Techline at Fluorescent Work Light with GFCI Protected Receptacle ● 13 Watt Lamp and Receptacle ● Black Body with 20’ Yellow Cord 16/3 SJTW ● NEMA 5-15R Receptacle; NEMA 5-15P Plug ● Automatic Reset In-Line GFCI with Power Status Indicator PAGE F4 POWER CENTER PB101-SGF “THE BOX”™ ● 6 GFCI Protected 20A 125V Straight Blade or Locking Receptacles ● GFCI Protected 30A 250V Locking Receptacle ● 50A 125/250V Non-NEMA Power Connections ● Meets OSHA Regulation 20, Subpart K Strandards ● UL Listed for Outdoor Use PAGE F7 1-800-824-3005 or visit us at:  www.leviton.com SmartLock® GFCI Features 2 YEAR LIMITED UL Standard 943 Class A (GFCI) & 498 (Receptacles) CSA Certified (File #057) Meets 2003 UL Requirements Thick-walled, impact-resistant thermoplastic nylon cover and body withstands abuse Heavy duty double wipe for 15 Amp contacts and triple wipe for 20 Amp contacts Silver alloy contacts for reliable make/break switching. Triple combination terminal screws. “Surge hardened” electronics offer superior resistance to surges and overvoltages. LED power indicator light helps diagnose improper wiring and, when illuminated, offers visual confirmation that power is available. Eight back-wired holes (Four on each side) provide maximum wiring capability. Provisions for backor side-wiring. Leviton® SmartLock® icon ensures improved GFCI product design. Lockout action blocks the “RESET” button if GFCI protection has been compromised. COMPONENT DESCRIPTION Face Nylon Back Nylon Line Contacts Brass Terminal Screws Brass #10-32 Grounding Screw Brass #8-32 Yoke Zinc Steel Clamp Nuts Internal Contacts Steel Silver Alloy NEMA ANSI WD1&WD6 C-73   Advanced electronics design provides superior resistance to electrical surges and over-voltages. Leviton SmartLock® Meets or Exceeds These Tougher Requirements Effective January 2003 • Diagnostic Indication for Miswiring • Surge Immunity • Corrosion Resistance • False Tripping STANDARDS & CERTIFICATIONS UL UL 943 CSA Listed Class A & 498 NOM #E48380 #057  LED indicator offers visual confirmation of power availability. SmartLock® GFCI Features Patented lockout feature prevents “RESET” if GFCI is not functioning properly or miswired due to reversal of line and load leads. #LR-57811 For additional details on these new requirements, see page F9. To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:  www.leviton.com F 2 15A 125V & 20A 125V Hospital & Commercial Grade, GFCI's ELECTRICAL DIELECTRIC VOLTAGE CURRENT INTERR. Withstands 1500V per UL 498 10kA 5±1 mA STANDARDS & CERTIFICATIONS MECHANICAL TEMP. RISE TERMINAL TERMINAL I.D. ACCOMMODATION Brass, hot TRIP LEVEL 2 YEAR LIMITED 30C max at full rated current after 50 cycles overload at 150% rated current for both AC and DC appl. per UL 498 #14 - #12 AWG solid or stranded copper wire Grounding Silver, neutral NEMA ANSI WD-6 C-73 PRODUCT I.D. Ratings permanently marked on device UL UL 943 Fed Spec Class A Listed & 498 WC-596    ENVIRONMENTAL – CSA NOM C22.2 #LR-57811 #057 AC HORSEPOWER RATINGS FLAMMABILITY OPERATING TEMP. Rated V-2 per UL 94 -35C to 65C 1.5 Hospital & Commercial Grade GFCI Devices Back & Side Wired FACE COLOR GFCI HOSPITALGRADE SMARTLOCK® DUPLEX w/ LED Meets 2003 UL Requirements GFCI GFCI GFCI GFCI GFCI COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE COMMERCIAL GRADE SMARTLOCK® SMARTLOCK® SMARTLOCK® DUPLEX w/ RED & BLANK FACE BLACK BUTTONS S-P SWITCH DUPLEX w/ LED DUPLEX w/ 41/2” LEADS Contractor Pack 1.5HP@120V AC Meets 2003 UL Requirements Meets 2003 UL Requirements Meets 2003 UL Requirements Meets 2003 UL Requirements Meets 2003 UL Requirements 8598-HG 8598-HGI 8598-HGW 8598-HGG 8598-HGR 8598-HGE 8598-HGA 8598 8598-I 8598-W 8598-G 8598-R 8598-E 8598-A 8599 8599-I 8599-W 8599-G 8599-R 8599-E 8599-A – 8599-LI 8599-LW – – – – – 8599-CPI 8599-CPW – – – 8599-CPA – 8590-I 8590-W – – 8590-E – 20A 125V, NEMA 5-20R at Receptacle & Feed-Through Brown Ivory White Gray Red Black Almond 8898-HG 8898-HGI 8898-HGW 8898-HGG 8898-HGR – 8898-HGA FACE COLOR 8898 8898-I 8898-W 8898-G 8898-R – 8898-A 8899 8899-I 8899-W 8899-G – 8899-E 8899-A – – – – – – – – – – – – – – GFCI COMBO DEVICE RECEPTACLE & SINGLE-POLE SWITCH – – – – – – – COLOR SHALLOW WALLBOX EXTENDER FOR GFCI's Meets 2003 UL Ruquirements 15A 125V, NEMA 5-15R; 20A 125V Feed-Through 1.53 (38.9 mm) 8598-HG & 8898-HG SERIES Brown Ivory White 1.53 (38.9 mm) 8598,8898, 8599-L & 8599-CP SERIES To learn more about Leviton devices or for answers to technical questions call our Techline at 6197 6197-I 6179-W ) 4.21 (106.93 mm) ) ) 4.21 (106.93 mm) 8299-I 8299-W 8299-G 8299-A 4.21 (106.93 mm) Ivory White Gray Almond ) 4.21 (106.93 mm) 3 8590-W 8599-CPI 15A 125V, NEMA 5-15R; 20A 125V Feed-Through Brown Ivory White Gray Red Black Almond 8299-G F 8599-LW 8599-I 8598-E 8598-HGR 1.53 (38.9 mm) 8590 SERIES 1-800-824-3005 or visit us at: 1.53 (38.9 mm)  8299 SERIES www.leviton.com 15A 125V & 20A 125V Commercial Grade, GFCI's 2 YEAR LIMITED ELECTRICAL DIELECTRIC VOLTAGE CURRENT INTERR. Withstands 1500V per UL 498 10kA STANDARDS & CERTIFICATIONS MECHANICAL TEMP. RISE TERMINAL I.D. TERMINAL ACCOMMODATION Brass, hot 30C max at full rated current after 50 cycles overload at 150% rated current for both AC and DC per UL 498 TRIP LEVEL 5±1 mA #18- #12 AWG Grounding Silver, neutral OPERATING TEMP. Rated V-2 per UL 94 -35C to 66C Gray Yellow 86593 Right Angle Plugs Accessory ANGLE PLUG ANGLE PLUG AUTOMATIC RESET COLOR WATERPROOF COVER WITH GROUND PIN UP ORIENTATION MANUAL RESET 15A 125V, NEMA 5-15P 20A 125V, NEMA 5-20P 6593 – 6893 – – 6594 #LR-57811 #057 1.5 6894 MANUAL RESET NOM C22.2 AC HORSEPOWER RATINGS FLAMMABILITY Recognized Component AUTOMATIC RESET – CSA Clear – 6894 86593 High Current GFCI Contact Rating: 20A 125V AC Load Capability with 125V Control Relay 80@240V AC Max. 20A 125V PANEL MOUNT GFCI w/ 16" LEADS & LED LIGHT YELLOW LEXAN TOGGLE COLOR 36596 Ivory PANEL MOUNT FOR TEMPORARY POWER DISTRIBUTION BOXES Front View 36597 Recognized Component BLANK FACE RESET BUTTONS Side View 8895-80I White 8895-80W Black 8895-80E Recognized Component Commercial Grade GFCI’s PLUG COLOR UL UL 943 Fed Spec Class A Listed & 498 WC-596    ENVIRONMENTAL 6593 Right Angle GFCI Plugs NEMA ANSI WD-6 C-73 PRODUCT I.D. Ratings permanently marked on device GFCI-Protected Fluorescent Work Light w/Receptacle 13A 125V, 2-P 3-W Grounding GFCI CORD SET, YELLOW CORD, 16/3 SJTW BLACK BODY, ON/OFF POWER SWITCH, 13 WATT LAMP & RECEPTACLE W 5-15R ) 2.40 (64 mm) .023 REF. 5.12 (130 mm) 4.75 (121 mm) G 5-15P 2.58 (65.5 mm) 1.83 DIA. (49 mm) 1.60 DIA. (41 mm) 2.7 (68.6 mm) W NEMA CONNECTOR CLASS 3.8 (96.5 mm) G 66591-WL 1.74 (44.2 mm) ~~~~~~~ ~~~~~~ ~~~~~~~ NEMA PLUG .810 (20.6 mm) 20’ 4.21 (106.93 mm) LENGTH 1.29 DIA. (33 mm) 1.26 (32 mm) 36596 RIGHT ANGLE GFCI PLUGS To learn more about Leviton devices or for answers to technical questions call our Techline at 8895 1-800-824-3005 or visit us at:  www.leviton.com F 4 15A 125V&250V;20A125V&250V Automatic Reset GFCI Cord Sets & Power Supply Cords ELECTRICAL DIELECTRIC VOLTAGE CURRENT INTERR. Withstands 1500V per UL 498 10kA TERMINAL I.D. TERMINAL ACCOMMODATION Brass, hot 30C max at full rated current after 50 cycles overload at 150% rated current for both AC and DC per UL 498 Automatic Reset GFCI Cord Sets & Power Supply Cords TRIP LEVEL 5±1 mA STANDARDS & CERTIFICATIONS MECHANICAL TEMP. RISE Not Applicable Grounding Silver, neutral 1 YEAR LIMITED PRODUCT I.D. Ratings permanently marked on device ENVIRONMENTAL NEMA ANSI WD-6 C-73 UL UL 943 Fed Spec Class A Listed & 498 WC-596    – CSA #LR-57811 #057 AC HORSEPOWER RATINGS FLAMMABILITY OPERATING TEMP. Rated V-2 per UL 94 -35C to 66C 1.5 Automatic reset GFCI cord sets (black body) automatically reset ON when power is restored. 66891-3 66591-25C 66593 FACTORY-ASSEMBLED CORD SETS - Consult Techline for changes in length and/or configurations. LENGTH GFCI CORD SET AUTOMATIC RESET (15 AMP) 14/3 SJTW (20 AMP) 12/3 SJTW YELLOW CORD, BLACK BODY BLACK PLUG & CONNECTOR NEMA PLUG NEMA CONNECTOR 15A 125V, Cord Sets 2' 6' 25' 66591-2C 66591-6C 66591-25C 5-15P 5-15R 15A 125V, Cord Set Triple Outlet 3' 66593-3 5-15P 5-15R 15A 125V, Locking Cord Set 3' 66597-3 L5-15P L5-15R 15A 125V, Power Supply Cord 37' 26591-37C – 5-15P 15A 240V, Power Supply Cord 35' 26592-E – 6-15P 20A 125V, Cord Sets 3' 66891-3 5-20P 5-20R 20A 125V, Locking Cord Set 3' 66897-3 L5-20P L5-20R 20A 125V, Power Supply Cord 37' 36591-37C – 5-20P 20A 240V, Power Supply Cord F 5 35' 36592-E – 6-20P To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:  NOM C22.2 www.leviton.com 15A 125V;20A125V Manual Reset GFCI Cord Sets 1 YEAR LIMITED ELECTRICAL DIELECTRIC VOLTAGE CURRENT INTERR. Withstands 1500V per UL 498 10kA TERMINAL I.D. TERMINAL ACCOMMODATION Brass, hot TRIP LEVEL 5±1 mA STANDARDS & CERTIFICATIONS MECHANICAL TEMP. RISE 30C max at full rated current after 50 cycles overload at 150% rated current for both AC and DC per UL 498 Not Applicable Grounding Silver, neutral PRODUCT I.D. Ratings permanently marked on device NEMA ANSI WD-6 C-73 UL UL 943 Fed Spec Class A Listed & 498 WC-596    ENVIRONMENTAL – CSA NOM C22.2 #LR-57811 #057 AC HORSEPOWER RATINGS FLAMMABILITY OPERATING TEMP. Rated V-2 per UL 94 -35C to 66C 1.5 Manual reset units (yellow body) will not automatically reset after power interruption; the reset button must be pushed in. 69591 Manual Reset GFCI Cord Sets 69891 FACTORY-ASSEMBLED CORD SETS - Consult Techline for changes in length and/or configurations. LENGTH GFCI CORD SET AUTOMATIC RESET (15 AMP) 14/3 SJTW (20 AMP) 12/3 SJTW YELLOW CORD, BLACK BODY BLACK PLUG & CONNECTOR NEMA PLUG NEMA CONNECTOR 15A 125V, Cord Sets 3' 25' 69591-3 69591-25 5-15P 5-15R 15A 125V, Cord Set Triple Outlet 3' 69593-3 5-15P 5-15R 15A 125V, W/ Wetguard Plug & Connector Cord Set 3' 25' 69591-W3 69591-W25 5-15P 5-15R 5-20P 5-20R 20A 125V, Cord Set 3' 69891-3 20A 125V, Locking Cord Set 3' 69897-3 (Available as Special Order Only) L5-20P 20A 125V, w/ Wetguard Plug & Connector Cord Set 3' – L5-20R 69891-W3 5-20R 1.78 (45.2 mm) 5-20P 6.70 (170.2 mm) 36.0 (914.4 mm) 6.70 (170.2 mm) (9.32 ± 2 mm) 0.63 (15.6 mm) 2.50 (63.5 mm) 15A AUTO GFCI CORD 66591-2C - on page F4 To learn more about Leviton devices or for answers to technical questions call our Techline at 2.50 (63.5 mm) TEST RESET RESET 1.63 (41.1 mm) TEST BEFORE EACH USE TEST FOLLOW DIRECTIONS 0.367± 0.07 MANUAL RESET GFCI CORD 69897-3 1-800-824-3005 or visit us at:  www.leviton.com F 6 50A 125/250V Power Center "THE BOX" & Power Cords Temporary Portable Power Distribution Center/GFCI & Power Cords ELECTRICAL DIELECTRIC VOLTAGE CURRENT INTERR. Withstands 1500V per UL 498 10kA 1 YEAR LIMITED STANDARDS & CERTIFICATIONS MECHANICAL TEMP. RISE TERMINAL TERMINAL I.D. ACCOMMODATION Brass, hot 30C max at full rated current after 50 cycles overload at 150% rated current for both AC and DC per UL 498 TRIP LEVEL 5±1 mA Not Applicable Grounding NEMA ANSI WD-6 C-73 PRODUCT I.D. Ratings & NEMA I.D. permanently marked on device White,neutral  UL UL 943 Fed Spec Class A Listed & 498 WC-596   – ENVIRONMENTAL FLAMMABILITY Rated V-2 per UL 94 CSA #LR-57811 #057 OSHA OPERATING TEMP. "The Box" Meets Regulation 20, Part 1926, Subpart K Standards -35C to 66C Power Distribution Box - All Locking Receptacles 6 GFCI Protected 20A 125V Locking Receptacles; 1 GFCI Protected Locking Receptacle 30A 250V BOX COLOR POWER DISTRIBUTION BOX POWER INLET NON-NEMA POWER OUTLET NON-NEMA 6 NEMAGFCI PROTECTED 1 NEMAGFCI PROTECTED RECEPTACLES RECEPTACLE 50A 125/250V, NON-NEMA, NEMA L5-20R AND L6-30R Y Y Yellow PB101-SGF X X EQ GR EQ GR W W Non-NEMA Non-NEMA L5-20R L6-30R Power Distribution Box - Straight Blade Receptacles & 1 Locking Receptacle 6 GFCI Protected 20A/125V Straight Blade Receptacles; 1 GFCI Protected Locking Receptacle 30A 250V BOX COLOR POWER DISTRIBUTION BOX POWER INLET NON-NEMA POWER OUTLET NON-NEMA 6 NEMAGFCI PROTECTED 1 NEMAGFCI PROTECTED RECEPTACLES RECEPTACLE 50A 125/250V, NON-NEMA, NEMA 5-20R AND L6-30R Y Y Yellow PB103-SGF X X EQ GR EQ GR W W Non-NEMA Non-NEMA 5-20R L6-30R Power Cords Features Flexible, Abrasion-Resistant Construction Offering Reliable Performance to -31F LENGTH FACTORY-ASSEMBLED CORD SETS BLACK FLEXIBLE CORD w/ YELLOW & WHITE (3) #6 AWG and (1) #8 WEATHER-RESISTANT PLUG AWG CONDUCTORS NON-NEMA YELLOW & WHITE WEATHER-RESISTANT CONNECTOR NON-NEMA 50A 125/250V, NON-NEMA Y 50' 100' †Consult 22 16.00 in. IST DIS KRS-A9519 KUS-A9519 Y X EQ GR X W EQ GR W NON-NEMA† NON-NEMA† Factory for Other Configurations. 125V/20A GFCI for 30A-250V RECEPTACLE 125V/20A in. 125V/20A 125V/20A UTION RIB P T ET 12 in. 125V/20 END VIEW 1 SIDE VIEW 1 A 250V/30A F 7 NOM C22.2 .50 12 in in. Weather Resistant Cover For 30A Locking Recept. Circuit Breaker Cover 19 . TOP VIEW END VIEW 2 To learn more about Leviton devices or for answers to technical questions call our Techline at SIDE VIEW 2 1-800-824-3005 or visit us at:  www.leviton.com GFCI Accessories 2 YEAR LIMITED 5977-CL 4998-GY 4992 5977-GY 5997-CL 5997-GY Single-Gang Flush Cover Wallplates TYPE MOUNTING POSITION Vertical Horizontal Vertical Horizontal Horizontal Vertical Horizontal Horizontal Vertical Vertical FITS TYPE OF BOX 6196-V 6196 6196-VFS 6196-FS 4990 4992 4996-GY 4996-W 4998-GY 4998-W Standard Standard FS (4 Screws) FS (4 Screws) Standard Standard Standard Standard Standard Standard Raintight While-In-Use Covers TYPE MOUNTING POSITION Gray Plastic Gray Plastic SINGLE-GANG FLUSH COVER Vertical Vertical Mount w/ Extra Deep Cover Vertical Clear Plastic Clear Plastic 5977-GY 5977-DGY Clear Plastic Clear Plastic Surface-Mounted 5977-CL Vertical Mount w/ Extra Deep Cover Horizontal Horizontal Mount w/ Extra Deep Cover Horizontal Horizontal Mount w/ Extra Deep Cover Gray Plastic Gray Plastic FITS TYPE OF BOX 5977-DCL Outdoor-Type Boxes 5997-GY 5997-DGY or Flush-Mounted Wall Boxes 5997-CL 5997-DCL GFCI Accessories Gray Die-Cast Zinc Gray Die-Cast Zinc Gray Die-Cast Zinc Gray Die-Cast Zinc Gray Die-Cast Zinc Gray Die-Cast Zinc Gray Plastic White Plastic Gray Plastic White Plastic SINGLE-GANG FLUSH COVER Combination Receptacle Circuit Tester/GFCI Tester CATALOG NUMBER Compact tester checks for correct wiring, reversed polarity, open ground, open neutral, open hot, hot and ground reversed, and hot unwired. Device also evaluates status of GFCI protection. Selector switch applies 1, 2, 3, and 5 milliamp tests enabling user to check for leakage current in the GFCI circuit. 6185 6182 Carrying case for receptacle circuit tester and GFCI tester. 6185 3.30 (83.8 mm) DESCRIPTION 3.75 (95.6 mm) 6.59 (167.4 mm) 5.46 (138.7 mm) 2.88 (73.2 mm) Ø0 0.63 63 ((16 (16.0 0 mm)) cord opening F Ø 0.25 ((6.4 mm)) padlock opening 5.05 (128.3 mm) Ø0 0.25 25 ((16 (16.0 0 mm)) cord opening 5977 To learn more about Leviton devices or for answers to technical questions call our Techline at 5997 1-800-824-3005 or visit us at:  www.leviton.com 8 SmartLock® Information Background on GFCI Safety Issues: Important safety considerations for any GFCI installation have always included: • Is it wired properly (line/load reversal)? • Has it been damaged by voltage surges or corrosion so that it will not trip in the event of a ground fault? • Is it tested regularly? SmartLock® Information Industry-wide efforts to prevent line/load wiring reversals have never been 100% effective. More importantly, endusers still do not regularly test their GFCI’s. As a result, GFCI’s damaged by voltage surges or corrosion that may not operate properly are often reset without any further testing. Consumers are at risk by continuing to use a GFCI receptacle that cannot respond to a hazardous ground fault. This has been a particular concern for public safety agencies including the U. S. Consumer Product Safety Commission (CPSC). Meeting the New 1/1/03 UL Requirements: Manufacturers must implement changes to address the major GFCI concern: Be Smart...Look for the Lock 1) Diagnostic Indication for Miswiring- In brief, if GFCI’s are miswired with a line/load reversal, there must be a diagnostic indication. Leviton’s SmartLock® already conforms to this because it cannot be reset if there is a line/load reversal. 2) Surge Immunity - Since surges are a leading cause of GFCI failures, increased surge immunity is required. Corrosion Resistance - New criteria for corrosion resistance help to eliminate another cause of GFCI failures. 3) False Tripping - New requirements will also help ensure that GFCI’s are more resistant to false tripping caused by electrical noise. Leviton’s SmartLock will meet or exceed all the new corrosion resistance and noise immunity requirements. Leviton’s Unique Position: UL wants GFCI manufacturers to provide more protection for the internal GFCI circuitry and Leviton fully supports this effort. However, what will happen when a GFCI is damaged despite its improved resistance to surges and corrosion? Under the new requirements, the GFCI can still be reset after it’s damaged. Leviton developed the product that goes further: SmartLock. If for any reason SmartLock is damaged and can no longer provide F 9 ground fault protection, it cannot be reset. Leviton invented this patented lockout action and is currently the only GFCI manufacturer offering this feature and the first to manufacture a GFCI that is fully compliant with the new UL requirements for 2003. To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at:  www.leviton.com